13-96 (2)-174
TYPICAL CONDUIT CONCEALED ABOVE SUSPENDED CEILING TO CtIWNG SLAB * • • ' �' %�� CEILING SLAB • i NEXT JUNCTION BOX OR HOMERUN. ; �;Op . 0�5J vp •�• • 4. " ' COIL CLEARING �e '� • f �•.. �' JUNCTION BOX INSTALLED ABOVE ( 2 CONTACTS •. ` / f 1 I CEILING i'��; •j ; . CEILING. — AVOID CABLE HOLES, 1 HANGER �. S A/C DUCT, ETC. WIRE �. ' • ; ' j •. ; I I e NC SL -2 NO c h • GFI DEDICATED RECEPTACLE I I LIGHTING ' FIXTURE .'�' WP NEMA 3R . • � ��� ' i i SL-2 I ' LANDSCAPE LIGHTS I I I Z 1� 2 400�0 PITCH PAN I I I SL -4 3 LANDSCAPE LIGHTS I W/ PITCH I I °° SL -6 LANDSCAPE LIGHTS SUSPENDED FLEXIBLE CONDUIT 4 I CEILING GRID ALLOW SUFFICIENT SLACK I SL -6 LANDSCAPE LIGHTS BY OTHERS SO THAT FIXTURE CAN BE ROOF DECK 5 • TILE DIRECTION SHIFTED COMPLETE ` ;,.. ,; • : •. • I: . •r� r : •: I SL -10 Q ENTRY LIGHTS I IN ANY ± , I SPACE I I SPACE I CONDUIT e 0 0 ( SPACE I 0 0 O 8 POLE. 30 AMP I LIGHTING CONTACTOR NOTES: MECHANICALLY HELD I Q 0 PROVIDE #12 GREEN GROUND WIRE IN FLEXIBLE CONDUIT WITH BRANCH CIRCUIT WIRING AND BOND TO SQUARED "LX" SERIES. TIMECLOCK. J OUTLET BOX AND FIXTURE HOUSING. 2O SECURELY FASTEN FIXTURE TO CEILING FRAMING MEMBERS NTH FOUR (4) T —BAR CUPS PER FIXTURE. SUPPORT FROM SUSPENDED CEILING ONLY AS APPROVED BY ARCHITECT. LIGHTING FIXTURE MOUNTING DETAIL ROOF RECEPTACLE DETAIL LIGHTING CONTACTOR DETAIL SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. TWIST ALL LEADS TOGETHER 2 and 4 Hour Fire Rated Through f; (AS MANY TURNS AS ti 0 1 and 2 Hour Fire Rated Through Gras S' f, a Penetration Firestop for Single o G a Penetration Firestop for Single Q� PRACTICAL) AND TIE WRAP jj jj Metal Pipe through 3735 Green Rd. O Metal Pipe through 3735 Green Rd. 0 0 o BREAKER FEEDING +i ®Y Concrete Floors or Walls Beachwood, OH, 44122 ®� Beachwood OH 44122 S' S, Gypsum Wall Assemblies � � SURGE SUPPRESSOR (TYP) 1 s t eO using FYRE -SIL. 1's t e'er using TREMstop IA. raving not to scale CAJ 1064 F- Rating = 2 and 4 Hr. d WL 1158 Drawing not to scale ® ® Q T- Rating = o Hr. .� F- Rating = 1 and 2 Hr. 1 OPTIONAL, TVSS �� m ® 000 4 ® 0 r_-4 � � � LOCATIONS (CAT B3 OR C1 AS T- Rating = 1 /4 Hr. INDICATED ON DRAWINGS) m :.::�... Q m m .... P Q ...� m m --AT- ...................... © s ,' ' .:;� ..:: : ......::.�..::. ® OPTIONAL TVSS m ® DEVICE LOCATIONS m ® (CAT 83 OR C1 AS .... ...... ..... ...... m ® DRAWINGS) m 3 m ® m 0 Pro—Rated Concrete Floors or Block Wails: See Table below for min. thickness. 1 Pro —Rated Gypsum Wallboard /Stud Wall Assembly. m (D Metallic Fps: A) Steel Pipe — 4" diam. (or smaller) Sch. 10 (or heavier) steel pipe. 22 Metallic Pipe: A) Steel Pipe — 12" diam. (or smaller) Sch. 10 (or heavier) steel pipe. 0 0 0 B) Iron Pipe — 4" diam. (or smaller) cast or ductile iron pipe. B) Iron Pipe — 12" (Ram. (or smaller) cast or ductile iron pipe. C) Conduit — 4" diam. (or smaller) EMT or steel conduit. D) Capper Tubing — 4" diam. (or smaller) Type L (or heavler) copper tubing. C) Cooper Tubing — 4" diem. (or smaller) Type L (or heavier) cooper tubing. E) Copper Pipe — 4' diam. (or smaller) Regular (or heavier) copper pipe, 0 Packing Material — See Table below for the mineral wool insulation requirements. D) Copper Pipe — 4" diam. (or smaller) Regular (or heavier) copper pipe. Q4 FYRE —SFL — M'm. 1/2" thickness of sealant applied within annulus, flush with top NEUTRAL BUS CONNECTION of floor surface or with both sides of the wall assembly. E) Conduit - 4" diam. (or smaller) EMT or 6" diam. (or smaller) steel conduit. Min. Thickness Annular Min. Packing Material Min. Packing Material F- FRating The annular space shall be min. 0" to max. 1" within the flrestop system. of Concrete. in. Thickness, in, Density. Dcf 3O TREMstop U - Min. 1/2" thickness of sealant applied within opening. 4-1/2 1/2 to 7/8 35 6.0 2 Min. 3/8" cant bead of sealant to be applied at areas of point contact. NOTE MOUNT TVSS DEVICE IN A LOCATION TO MAINTAIN 5 -1/2 0 to 1 -7/8 5 4.0 4 ALL LEADS AS SHORT AS POSSIBLE (18" MAX.) 2 AND 4 HOUR FIRE RATED THROUGH 1 AND 2 HOUR FIRE RATED THROUGH TVSS EXTERIOR MOUNT INSTALLATION SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. R00 FUTURE TENANT 3 FUTURE TENANT 2 L ,.. (2)4" CONDUITS FUTURE TENANT 1 38" �•• •'i' i'' ROUTED UP TO 4TH FLOOR. NO CONCRETE COVER 90 DEGREES BENDS PULL SLOT FOR FIBER. TYPICAL 4TH FLR INSERT FOR 3RD FLR CABLE RACKS BODY SECTION 400 3 "C. FOR CATV 2 0C. FOR TELE /DATA 40 36 #6 GROUND TO BACKBOARD 3/4" TO FACP ADEQUATE RACKS o �� SHALL BE PROVIDED FOR ALL CABLES. (2) 4 "C SLEEVES TELECOM TV TYPICAL PLYWOOD Hid TC PULL EYE MOUNTING BOARDS FOR I- w A. . PLAN. 60 �. 11 (2) 4" SCHEDULE 40 PVC 4 3/8 FUTURE TENANT 3 FUTURE TENANT 2 STORAG E (2)4" CONDUITS FUTURE TENANT 1 ROUTED UP TO 4TH FLOOR. NO 90 DEGREES BENDS FOR FIBER. 4TH FLR 3RD FLR 3 "C. FOR CATV 2 0C. FOR TELE /DATA 2ND FLR #6 GROUND TO BACKBOARD 3/4" TO FACP R RQOM 4'x8'x3/4" 4'x8'x3/4" 4'x8'x3/4" (2) 4 "C SLEEVES TELECOM TV TYPICAL PLYWOOD Hid TC MOUNTING BOARDS FOR TELEPHONE EQUIPMENT AS SHOWN ON FLOOR PLAN. 1ST FLR G 11 (2) 4" SCHEDULE 40 PVC 2 INSULATING BUSHING 1-C. W/ PULLSTRING IDENTIFICATION STRIPS STUB -UP ABOVE W/ PLASTIC COVER ACCESSIBLE CEILING (TYP. TOP AND BOTTOM) 15 > RJ 46 JACK TERM. DETAIL 68813 ci4TE: \\-PLASTIC FACE PLATES 1. CONTRACTOR SHALL INCLUDE IN HIS BID THE EXACT WITH SNAP -IN INSERTS CONFIGURATION REQUIRED BY THE OWNER FOR THIS PROJECT. WIRE TO MAIN ELECTRICAL FOR TELEPHONE TO 1" HOLE FOR 2. INDIVIDUAL JACK OUTLETS TO BE IDENTIFIED BY COLOR GROUND ROD SIDE WALL SERVICE GROUND BUS. PROPERTY LINE. (BLUE. GREEN, PURPLE, YELLOW). KNOCKOUT 3/4 "C. WITH #6 GROUND (1) 4" SCHEDULE 40 PVC - - FOR CAN TO THE END WALL 1* pU�LL IRONS INSERTS ��` PROPERTY LINE. KNOCKOUT 1. PROVIDE NYLON PULLSTRING IN ALL EMPTY CONDUITS. 2. PROVIDE FIRE CAULKING AT ALL FLOOR PENETRATIONS. QUAZITE: PG3636DA36 3. LOW VOLTAGE WIRES ENTERING THE BUILDING AND WITH PG3636HAOO COVER TERMINATING ON THE OUTSIDE OF THE BUILDING SHALL COMPLY WITH NEC 725.141. HANDHOLE DETAIL LOW VOLTAGE SYSTEM RISER DIAGRAM G58cP Design Services® For The Built Environment N Atlanta Birmingham Cincinnati Columbus Dallas Fort Lauderdale Knoxville Jackson Jacksonville Louisville Memphis Nashville Richmond Tampa 0 G R E S H A M S M I T A N D P A R T N E R S 6030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 954.981.9100 FIRM'S FLORIDA CERT. NO. AAP000034/CA3806 IB26000797/LC26000381 707 N.B. 3rd AVE., 3UME 200 FORT LAUDERDALE, FL 33304 , 961) 527 -1112 CAJ00009181 PJT. MGR: miam . H00 PROJECT /: 120717 e Vftm It w m w Q e '-a r\ LL. - to r \\\ iCS 0_ L0 W o t4 0 6 00 • :jr ' to - E OF ::(11 ' • T 'rrJrrrii� � REVISION No. - Date - Revision 1 ; 02/01/13 1 Addendum #1 t........................ :........................ ............................... : 03/15/13 = City Comments 2 - A-----------------------------------•--------------------....----------------..........----- ............................................................................................................... ELECTRICAL DETAILS AND LIGHTING FIXTURE SCHEDULES E5.1 PROJECT: 29080.00 13