13-96 (2)-110GENERAL LIGHTING NOTES: 1. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF LIGHT FIXTURES. 2. COORDINATE TYPE OF CEILING FOR EACH FIXTURE WITH ARCHITECTURAL REFLECTED CEILING PLANS AND PROVIDE FIXTURE TRIM AS REQUIRED. 3. ALL COMPACT FLUORESCENT DOWNUGHTS SHALL USE LAMPS WITH 3500K TEMPERATURE. MINIMUM 10,000 HOUR LIFE, ELECTRONIC BALLAST, UNLESS OTHERWISE NOTED. 4. PROVIDE APPROVED FIRE RATED ENCLOSURES FOR ALL LIGHT FIXTURES LOCATED IN FIRE RATED CEILINGS. 5. FIXTURES IN AREAS WITHOUT CEILINGS, OR IN MECHANICAL AND ELECTRICAL ROOMS SHALL BE MOUNTED WITH 1 7¢"X1 WKINDORF CHANNEL SUPPORT SUSPENDED FROM ROOF STRUCTURE WITH THREAD RODS. FIXTURES SHALL BE MOUNTED 10' -0" A.F.F. 6. ALL ACRYLIC LENSED FIXTURES SHALL HAVE A LENS THICKNESS OF .125 INCHES MINIMUM. 7. HALF SHADED FIXTURES DENOTE EMERGENCY FIXTURES EITHER WITH 1100 LUMEN EMERGENCY BATTERY PACK OR ON LIFE SAFETY CIRCUIT. 8. LIGHTING FIXTURE SCHEDULE IS PREDICTED ON PERFORMANCE AND IS DESIGNED TO MEET CERTAIN AESTHETIC CRITERIA. ALL ALTERNATIVE SELECTIONS MUST BE SUBMITTED FOR PRIOR APPROVAL TEN (10) DAYS PRIOR TO BID DATE 9. ALL BALLASTS SHALL HAVE MINIMUM POWER FACTOR OF 0.90. ALL BALLASTS FOR METAL HALIDE AND HIGH PRESSURE SODIUM FIXTURES SHALL BE CONSTANT WATTAGE TYPE WITH + / -5X LAMP WATTS FOR + / -10X NOMINAL LINE VOLTAGE VARIATION. 10. PROVIDE LAMPS WITH FIXTURES, VERIFY LAMP TYPE WITH MANUFACTURER. 11. FLUORESCENT LUMINAIRES THAT UTILIZE DOUBLE -ENDED LAMPS AND CONTAIN BALLAST(S) OR MULTMIIRE BALLASTED LUMINAIRES SHALL CONTAIN AN INTEGRATED INTERNAL DISCONNECT AND TO BE COMPLIED WITH NEC 410.130(G). 12. ALL OPENINGS FOR LIGHT FIXTURES IN CEILINGS SHALL BE PROTECTED IN A MANNER (PER ALL GOVERNING CODES) THAT WILL PROVIDE THE SAME RATING AS THE CEILING. (THIS APPLIES TO ALL FIRE RATED CEILINGS). 13. FOR EMERGENCY EXIT SIGNS AND EMERGENCY BATTERY PACKS MAKE CONNECTION AHEAD OF ALL SWITCHES AND CONTROLS. 14, PROVIDE A FUSE HOLDER AND FUSE (BUSSMAN HEB AND FNQ OR EQUAL), IN THE PRIMARY SIDE OF EACH UNGROUNDED CONDUCTOR FOR ALL BALLASTS AT THE HAND HOLE OF EACH EXTERIOR POLE MOUNTED LIGHTING FIXTURE OR J -BOX FOR WALL OR GROUND MOUNTED FIXTURE 15. PROVIDE WIND LOAD RATED LIGHT POLES WITH 145 MPH MINIMUM WIND SPEED (ASCE 7). EXPOSURE C WITH IMPORTANCE FACTOR OF 1.0, AND PROVIDE PHOTOMETRICS WITH ALL FIXTURE SUBMITTALS. CONTRACTOR TO VERIFY VOLTAGES OF ALL LIGHT FIXTURES PRIOR TO BIDDING. 16, PHOTOMETRICS ARE BASED ON MANUFACTURER'S INFORMATION AND CATALOG NUMBERS. ALTERNATIVE MANUFACTURERS MUST PROVIDE THE IESNA FORMAT ELECTRONIC FILES OF THE INDEPENDENT TEST LAB REPORTS FOR THE PROPOSED FIXTURES ON CD OR FLOPPY DISKETTE 10 WORKING DAYS PRIOR TO BID. (SPECIFIER) WILL CONFIRM THAT THE PHOTOMETRIC CRITERIA HAS BEEN MET, AND IF ALTERNATE IS APPROVED WILL ISSUE AN ADDENDUM. MANUFACTURERS NOT LISTED ON THE PLANS OR IN AN ADDENDUM WILL NOT BE ACCEPTED. 17. TO CONFIRM THAT THE SPECIFIED PHOTOMETRIC CRITERIA HAS BEEN MET, A COMPUTER DISK CONTAINING AN IES FILE FOR THE PROPOSED ALTERNATE MUST BE SUBMITTED TO (SPECIFIER) FOR EVALUATION NO LESS THAT 10 DAYS PRIOR TO BID. ANY ACCEPTABLE ALTERNATE MUST BE APPROVED IN WRITING PRIOR TO BID DATE 18. CONTRACTOR MUST BID PROJECT USING SPECIFIED LIGHTING FIXTURES AS BASE BID (NO EXCEPTIONS). IF ALTERNATE FIXTURES ARE PROPOSED. THEY MUST BE BID AS AN ALTERNATE BID MUST INCLUDE: A) TOTAL DOLLAR CREDIT TO OWNER IF ALTERNATE IS ACCEPTED. B) LINE ITEM CREDIT FOR EACH ALTERNATE FIXTURE PROPOSED. C) CATALOG SUBMITTAL DATA FOR EACH ALTERNATE FIXTURE PROPOSED. 19. IF THERE IS A DISCREPANCY BETWEEN A FIXTURE DESCRIPTION AND GENERAL NOTES, AND THE CATALOG NUMBER LISTED, THE FIXTURE DESCRIPTION AND GENERAL NOTES SHALL GOVERN. 20. COORDINATE FIXTURE TYPES WITH ARCHITECTURAL DRAWINGS. ELECTRICAL SYMBOL LEGEND SYMBOL GENERAL ELECTRICAL NOTES ' DESCRIPTION (GENERAL NOTES ARE PROVIDED AS A BASIC DESCRIPTION OF THE EXTENT AND QUALITY EXPECTED IN THIS PROJECT. IF A CONFLICT EXISTS LIGHT FIXTURE DESIGNATION. BETWEEN THESE GENERAL NOTES AND THE REMAINDER OF THE CONTRACT DOCUMENTS THE SPECIFICATIONS, PLANS AND DETAILS WILL GOVERN.) 1. THE ENTIRE INSTALLATION SHALL BE IN ACCORDANCE WITH THE FOUOWING CODES OF THE BATTERY BACK -UP FOR A MINIMUM OF 90 MINUTES. CLOCK LIGHTING FIXTURE, SURFACE MOUNTED NATIONAL FIRE PROTECTION ASSOCIATION: 28. ALL CIRCUIT BREAKERS SHALL BE INVERSE TIME TYPE (THERMAL MAGNETIC OR SOLID LIGHTING FIXTURE, WALL MOUNTED A. NFPA 70: NATIONAL ELECTRICAL CODE (2008 EDITION) DOT LIGHT FIXTURE. DIRECTION ARROWS AS SHOWN STATE AS REQUIRED BY SPECIFICATION). TWO AND THREE POLE CIRCUIT BREAKERS WALL MOUNTED EXIT LIGHT FIXTURE B. NFPA 72: NATIONAL FIRE ALARM CODE (2007 EDITION) SHALL BE COMMON TRIP. NO TIE HANDLES PERMITTED. O2 IN ADDITION, THE INSTALLATION SERI. ALSO BE IN ACCORDANCE WITH THE FOLLOWING: 29• ALL FUSES SHALL BE CURRENT LIMITING, PER U.L. RATED 600V., LION. 2 X 4 FLUORESCENT LIGHT FIXTURE C. 2010 FLORIDA BUILDING CODE SHADED FIXTURE INDICATES FIXTURE TO BE PROVIDED WITH 90 MINUTE 1100 A. NON -TIME DELAY FUSES IN MAIN SWITCHES AND SWITCHES FEEDING PANELS. LUMEN BATTERY BACK -UP FOR LINEAR FLUORESCENT FIXTURES AND 700 LUMEN D. FLORIDA FIRE PREVENTION CODE (2007 EDITION) BATTERY BACK -UP FOR COMPACT FLUORESCENT FIXTURES. S. TIME DELAY FUSES FOR MOTOR AND A/C CIRCUITS. 1 X 4 FLUORESCENT LIGHT FIXTURE NEW EQUIPMENT OR WORK OF THIS PROJECT 30. ALL DISCONNECT SWITCHES SHALL BE SIZED BY NEC REQUIREMENTS TO ACCOMMODATE 2. AS A MINIMUM, ALL EQUIPMENT SHALL MEET APPLICABLE STANDARDS, FOR THE TYPE OF DIAGONAL SHADING DENOTES LIGHT FIXTURE CONNECTED TO EMERGENCY EQUIPMENT SERVED, INCLUDING REQUIRED FUSES U.O.N. SWITCHES SHALL BE BRANCH CIRCUIT OR. W /EMERG. BATTERY PACK. EQUIPMENT AND INTENDED USE, OF THE FOLLOWING: EXTERIOR LIGHT FIXTURE WITH ARMS AS SHOWN ON DRAWINGS HORSEPOWER RATED FOR MAX. HORSEPOWER, HEAVY DUTY TYPE. TOGGLE SWITCH 120/277V. 20 AMP.,(M.H. - 48" A.F.F.) A. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) B. ILLUMINATING ENGINEERS SOCIETY (IES) 31. CONTRACTOR SHALL VERIFY CIRCUIT PROTECTIVE DEVICE RATING FOR EQUIPMENT PRIOR TOGGLE SWITCH 120/277V. 20 AMP.. (M.H. - 48' A.F.F.). 4 -WAY C. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ABTA) TOGGLE SWITCH 120/277V. 20 AMP. KEYSWITCH. (M.H. = 48" A.F.F.) TO INSTALLATION. FAN SWITCH 120/277V. 20 AMP, HORSEPOWER RATED D. NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATES.(NEMA) 32. FURNISH AND INSTALL DISCONNECT SWITCHES AND WIRING FOR AIR CONDITIONING TOGGLE SWITCH 120/277V. 20 AMP., WITH PILOT LIGHT. E. NOTE. THESE STANDARDS ARE SUBORDINATE TO CODES AND STANDARDS SET BY U.L. ALL ELECTRICAL EQUIPMENT, DEVICES, WIRE, ETC., SHALL (M.H.-48-A.F.F.) SYSTEM PER MANUFACTURER RECOMMENDATIONS. CONTROLS ARE TO BE SUPPLIED AIR CO NDITIONING CONTRACTOR AND CONNECTED. PROVIDE ALL CONTROL WIRING FOR TOGGLE SWITCH 120/277V. 20 AMP. EXPLOSION- PROOF. BE LISTED, FOR INTENDED USE, WITH UNDERWRITER'S LABORATORIES INC. (U.L). WHERE STANDARDS HAVE BEEN (M.H.- 480A.F.F.) SN NG AND COMROL UNITS, COORDINATE WITH A/C CONTRACTOR FOR WIRING SPEED SWITCH 120/277V. 20 AMP. U.O.N. ,(M.H. - 48" A.F.F.) ESTABLISHED BY U.L SINGLE PHASE MANUAL MOTOR STARTER. (M.H. -48" A.F.F.) DIA IAGRAMMS S AND DD EXACT MOUNTING LOCATIONS. 3. CONTRACTOR TO PROVIDE ALL LABOR, MATERIALS AND SUPERVISION NECESSARY TO 33. ALL ELECTRICAL EQUIPMENT SHALL BE RAINTIGHT WHERE EXPOSED TO THE WEATHER. THREE -WAY DIMMER SWITCH (48' A.F.F.) ACCOMPLI SH THE WORK AS SHOWN AND /OR NOTED ON THE DRAWINGS. SINGLE POLE SWITCH (48" A.F.F.) (SUBSCRIPT INDICATES ITEM ALL FLEX CONDUITS CONNECTED TO SUCH EQUIPMENT SHALL BE LIQUID TIGHT. CONTROLLED) © 34. EQUIPMENT SHALL BE OF MATERIALS SUITABLE FOR AND NEMA RATED FOR THE 4. THE CONTRACTOR SHALL VISIT THE JOB SITE AND VERIFY ALL CONDITIONS, LOCATIONS, SENSOR SWITCH /#WSD -PDT ENVIRONMENT IN WHICH THEY ARE TO BE INSTALLED. (a, b) OR (2) INDICATES TWO POLE SWITCH - WSD- PDT -2P DIMENSIONS AND COUNTS AS SHOWN OR NOTED ON THE DRAWINGS, PRIOR TO SUBMITTING BID. 35. ALL CONNECTIONS TO GROUND RODS SHALL BE MADE WIT H U.L APPROVED WELDED CEILING MOUNTED OCCUPANCY SENSOR - LIGHTING CIRCUIT CONTROLLER. FUSE SIZE ( * DENOTES AS PER MANUFACTURER) MFGR. /MODEL# (SENSOR SWITCH /JCM -PDT) CONNECTIONS, UNLESS NOTED OTHERWISE. THE CONTRACTOR SHALL FORM A 5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL LABOR, SENSOR - LIGHTING CIRCUIT CONTROLLER. SENSOR SWITCH / #CM- PDT -10. GROUNDING ELECTRODE SYSTEM AS PER NEC 250 -50. WALL MOUNTED - OCCUPANCY SENSOR (M.H.= 967A.F.F.) MATERIALS AND SUPERVISION NECESSARY TO ACCOMPLISH THE WORK AS SHOWN MFGR. /MODEL #WV -PDT Ea POWER PACK AND /OR NOTED ON THE PLANS. 36, OUTLET IN DRY LOCATIONS BOXES SHALL BE PRESSED STEEL. IN WET OR DAMP -0 CONDUIT TURNING DOWN ] LOCATIONS SHALL BE CAST ALLOY WEATHER- RESISTANT OUTLET WITH THREADED HUBS 6. ELECTRICAL CONTRACTOR SHALL NOT SCALE DRAWINGS. CONTRACTOR SHALL REFER TO A.F.F. AND IN OTHER CLASSIFIED AREAS IT SHALL BE IN A SPECIAL. ENCLOSURE. PROPER G.F.I. ARCHITECTURAL PLANS AND ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPMENT A.S.W. PLASTER RINGS SHALL BE USED WITH OUTLET BOXES. PROPER COORDINATION BETWEEN L.C. UNLESS NOTED OTHERWISE. B.F.C. ELECTRICAL SUBCONTRACTOR AND GENERAL CONTRACTOR FOR PLASTER RING INITIATION M.H. MOUNTING HEIGHT B.F.G WILL BE REQUIRED. NO "GOOF' RINGS SHALL BE ALLOWED. ALL OUTLET BOXES SHALL 7. IT SHALL BE UNDERSTOOD THAT ALL WORK PERFORMED SHALL BE DONE BY A LICENSED C.B. BE SECURELY FASTENED. N.F. CONTRACTOR AND IN A FIRST -CLASS WORKMANLIKE MANNER. SAID CONTRACTOR SHALL MEET ALL REQUIREMENTS SET FORTH BY ANY LOCAL ORDINANCE A,�D GOVERNING 37. WHEN ELECTRICAL BOXES ARE LOCATED IN VERTICAL FIRE RESISTIVE ASSEMBLIES, NL AUTHORITIES. D (CLASSIFIED AS FIRE /SMOKE AND SMOKE PARTITIONS), THEY SHALL BE INSTALLED 8. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED INSURANCE FOR PROTECTION AGAINST WITHOUT AFFECTING THE FIRE CLASSIFICATION. ALL OF THE FOLLOWING CONDITIONS SHALL BE MET: PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. A. ALL ELECTRICAL BOXES SHALL BE METALLIC. 9. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS IG B. BOX OPENING SHALL OCCUR ONLY ON ONE SIDE OF FRAMING SPACE T.S. FOR A PERIOD OF NOT LESS THAN ONE YEAR FROM DATE OF ACCEPTANCE, UNLESS C. BOX OPENING SHALL NOT EXCEED 10322.56 SQUARE MM (16SQUARE INCHES). INDICATED OR SPECIFIED OTHERWISE. D. ALL CLEARANCES BETWEEN OUTLET BOX AND GYPSUM BOARD SHAW. BE 10. I IT SHALL NOT BE THE INTENT OF THESE PLANS AND/OR SPECIFICATIONS TO SHOW S AN EM COMPLETELY FILLED WITH JOINT COMPOUND (OR OTHER APPROVED MATERIAL). EVERY MINOR DETAIL CONSTRUCTION. THE OR SHALL BE EXPECTED TO E PROVIDE A WALL AROUND OUTLETS LARGER THAT 10322.56 SQUARE MM (16 WR. FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE SQUARE INCHES). THE INTEGRITY OF THE WALL RATING SHALL BE MAINTAINED. XFMR. FOR ALL REQUIREMENTS NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER F. THE TOTAL AGGREGATE SURFACE AREA OF THE BOXES SHALL NOT EXCEED 64516 WP. WORKING ORDER. RR SQUARE MM (100 SQUARE INCHES) PER 9.29 SQUARE METERS (100 SQUARE FEET). 11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING TO ORIGINAL CONDITIONS, ANY AND ALL DAMAGES TO BUILDING SURFACES, EQUIPMENT, ETC. CAUSED DURING THE G. OUTLET BOXES LOCATED ON OPPOSITE SIDES OF FIRE RESISTIVE ASSEMBUES SHALL BE SEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 609.6MM (24 INCHES). H. OUTLET BOXES - , PERFORMANCE OF WORK. NOTE SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJE SHALL BE SECURELY FASTENED TO WALL FRAMINGG MEMBERS. I. THE OPENING IN THE GYPSUM BOARD FACING SHALL BE CUT NOT TO EXCEED 12. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE OR 3.175MM (1 /8 INCH) BETWEEN THE EDGES OF THE OUTLET BOX AND THE EDGES OF DELAYS AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE THE OPENING. INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. 38. SMOKE DETECTORS SHALL BE PROVIDED NO CLOSER THAN 36" FROM SUPPLY AIR 13. FOR ELECTRIC POWER SYSTEM, COORDINATE POWER SERVICE WITH POWER COMPANY; DIFFUSERS. A. VERIFY LOCATION OF POWER SERVICE TERMINATION WITH POWER COMPANY. PRIOR TO SUBMITTING BID. CONTRACTOR TO VERIFY AVAILABLE SERVICE VOLTAGE AND PHASES 39. CONTRACTOR SHALL PROVIDE A TYPE WRITTEN DIRECTORY OF EACH PANELBOARD. HAND WRITTEN DIRECTORY IS NOT ACCEPTABLE, EXCEPT SPARE AND SPACES SHALL BE WITH POWER COMPANY PRIOR TO BID AND PROVIDE BID ALLOWANCE FOR ALTERNATES. HANDWRITTEN IN PENCIL B. PROVIDE TEMPORARY ELECTRICAL SERVICE FOR USE BY ALL TRADES DURING CONSTRUCTION AND REMOVE SAME AT COMPLETION OF PROJECT, 40. PROVIDE A 4" STEEL REINFORCED CONCRETE HOUSEKEEPING PAD UNDER ALL FLOOR MOUNTED ELECTRICAL EQUIPMENT. 14. CONTRACTOR SHALL KEEP ALL AREAS IN WHICH WORK IS BEING PERFORMED, FREE 41. A. WORKING CLEARANCES FOR ELECTRICAL EQUIPMENT SHIALL. BE IN COMPLIANCE WITH FROM DEBRIS AT ALL TIMES AND SAID AREAS SHALL BE LEFT BROOM CLEAN AT THE NEC 110.26 END OF EACH WORKING DAY. 15. CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS, AND TESTING COSTS. B. THE EXCLUSIVELY DEDICATED SPACE EXTENDING FROM FLOOR TO STRUCTURAL CEILING WITH A WIDTH AND DEPTH OF THE PANELBOARDOR SWITCHBOARD MUST BE 16. COORDINATE ALL ELECTRICAL SITE WORK WITH ALL OTHER TRADES CONTRACTORS. CLEAR OF ALL PIPING, DUCTS. EQUIPMENT FOREIGN TO THE ELECTRICAL EQUIPMENT OR ARCHITECTURAL APPURTENANCES IN ACCORDANCE WITH NEC 408. 17. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR FOR THE ADVANCE ORDERING OF LONG LEAD ITEMS. AS TO NOT INTERFERE WITH THE PRODUCTION OF 42, METER CANS, HUBS. & LUGS FOR SAME ARE TO BE FURNISHED & INSTALLED BY OTHER TRADES RESULTING IN ANY DOWN OR LAG TIME THE CONTRACTOR SHALL NOT CONTRACTOR. CONTRACTOR TO VERIFY SPECIFIC TYPE OF METER CAN TO BE USED WITH F.P.L. PRIOR TO BID. ORDER ANY ITEMS UNTIL APPROVED SHOP DRAWINGS ARE RETURNED TO HIM. 18. ELECTRICAL CONTRACTOR SHALL SUBMIT 6 COPIES EQUIPMENT LAYOUT OF ALL ( ) 43• A. PROVIDE A PERMANENT SIGN ON THE MAIN ELECTRICAL ROOM DOOR TO THE BLDG. STATING THAT THE SERVICE DISCONNECTS ARE LOCATED INSIDE ELECTRICAL SPACES, ROOMS, ETC., TO ENGINEER FOR APPROVAL PRIOR TO ORDERING CONSIST OF PLAN EQUIPMENT OR INSTALLING CONDUITS, ETC. LAYOUT SHALL. MEWS B. SIGNS SHALL BE PLACED AT THE MAIN DISCONNECT EQUIPMENT INDICATING TYPE AND (SCALED AS REQUIRED) AND ELEVATIONS (DIMENSIONED) FOR EACH SUCH SPACE. LOCATION OF ON -SITE EMERGENCY POWER SOURCES. ROOM, ETC. 44. THE EQUIPMENT GROUNDING TERMINAL BARS OF THE NORMAL AND EMERGENCY 19. CONTRACTOR SHALL SUBMIT AT ONE TIME, SIX (6) SETS OF LOOSE -LEAF BOUND ELECTRICAL SYSTEM PANELBOARDS SERVING THE SAME BUILDING SHALL BE BONDED BOOKS, INDEXED WITH ALL PRODUCTS, MATERIALS, LIGHTING FIXTURES, LAMPS, WIRING TOGETHER WITH AN INSULATED, CONTINUOUS, COPPER CONDUCTOR NOT SMALLER THAN DEVICES, SWITCHGEAR, ETC. CLEARLY HIGHLIGHTING ALL EQUIPMENT QUANTITIES AND NUMBER 6. DETAILS. ALL EQUIPMENT SHALL BE AS SPECIFIED ON PLANS: THE RESPONSIBILITY TO 45. THE ELECTRICAL CONTRACTOR SHALL FURNISH A COMPLETE SET OF AS -BUILT ACCEPT OR REJECT ANY PROPOSED SUBSTITUTION REMAINS WITH THE PROJECT ENGINEER. THE CONTRACTOR MAY AT HIS JUDGMENT USE ANY ARTICLE, DEVICE, DRAWINGS, SHOWING ALL CHANGES AND DEVIATIONS TO THE ARCHITECT /ENGINEER PRIOR PRODUCT, OR MATERIAL WHICH IN THE JUDGMENT OF THE ENGINEER EXPRESSED IN TO COMPLETION OF THE PROJECT. WRITING ARE EQUAL TO THAT SPECIFIED. 46. ARCHITECTURAL AND /OR ENGINEERING EXPENSES THAT ARE INCURRED DUE TO 20. ALL CONDUCTORS SHALL BE COPPER, TYPE THHN/THWN EXCEPT WHERE OTHERWISE REVISIONS OR SUBSTITUTIONS REQUESTED BY THE CONTRACTOR SHALL BE PAID FOR BY THAT CONTRACTOR. REQUIRED BY U.L OR CODES. MINIMUM WIRE SIZE SHALL BE #12 AWG. EXCLUDING CONTROL WIRING. ALUMINUM CONDUCTORS ARE NOT PERMITTED. 47. FOR TELEPHONE SYSTEMS: 21. ALL CONDUCTORS SHALL BE IN CONDUITS. ALL CONDUITS SHALL BE GALVANIZED RIGID A. PROVIDE GROUNDING FOR ALL TELEPHONE OUTLETS AND EQUIPMENT PER REQUIREMENTS OF THE TELEPHONE COMPANY. STEEL (GRS) EXCEPT THAT: (a) PVC CONDUITS MAY BE USED UNDERGROUND PROVIDED ELBOWS AND RISERS ARE GALVANIZED RIGID STEEL OR SCHEDULE 80 PVC, WHERE B. COORDINATE INSTALLATION OF ALL TELEPHONE OUTLETS, RACEWAYS. ENCLOSURES SUBJECT TO PHYSICAL DAMAGE (b) ELECTRICAL METALLIC TUBING (EMT) MAY BE USED AND BACKBOARDS WITH TELE CO. C. VERIFY LOCATION OF TELEPHONE SERVICE WITH TELEPHONE COMPANY. PROVIDE IN OR ON WALLS OR CEILINGS WHERE NOT SUBJECT TO MECHANICAL DAMAGE, DAMP OR SERVICE CONDUIT TO BLDG. FROM SERVICE POINT PER TELCO. INSTRUCTIONS, INCLUDE CORROSIVE CONDITIONS, (c) LIQUID TIGHT FLEXIBLE CONDUIT WHERE REQUIRED, (d) ALL ASSOCIATED COSTS IN BID. FLEXIBLE METALLIC CONDUIT WHERE REQUIRED IN DRY LOCATIONS ONLY, (e) MC CABLE D. MARK TERMINATIONS OF TELEPHONE CONDUIT AS DIRECTED BY THE TELEPHONE WITH DEDICATED GREEN GROUNDING CONDUCTOR WHERE PERMITTED. ALL CONDUITS IN COMPANY. HAZARDOUS AREAS (PEER NEC) SHALL MEET THE REQUIREMENTS OF NEC CHAPTER 5. E VERIFY LOCATION OF TELEPHONE SERVICE WITH TELEPHONE COMPANY PRIOR TO 22. FOR UNDERGROUND ELECTRICAL CONDUITS. PROVIDE PULL BOXES, SUCH THAT NO SUBMITTING BID, INCLUDE ALL ASSOCIATED COSTS IN BID. SINGLE CONDUIT RUN HAS BENDS IN EXCESS OF 360. PULL BOXES SHALL BE F. USE EXTERIOR GRADE 3/4" PLYWOOD BACKBOARDS FOR MOUNTING TELEPHONE SUITABLE AND APPROVED FOR THE INTENDED USE WARNING TAPE WHICH SAYS EQUIPMENT AND TERMINAL STRIPS. PAINT BOARD ON ALL SIDES AND EDGES WITH TWO "WARNING BURIED ELECTRIC" SHALL BE PLACED IN TRENCHES ABOVE ALL UNDERGROUND COATS OF FLAT BLACK FIRE RETARDANT PAINT. ELECTRIC CONDUITS. WHERE CONDUITS PASS UNDERNEATH PAVED AREAS, THEY SHALL 48. INDUSTRIAL CONTROL TYPE TRANSFORMERS SHALL BE PROVIDED WITH FlNGERSAFE BE PVC. WHERE UNDERGROUND CONDUITS ARE NOT EXPOSED TO MECHANICAL DAMAGE COVERS AND PRIMARY FUSE PROTECTION AS REQUIRED PER NEC 450 -3. MOUNT OR ARE NOT UNDER PAVED AREAS, THEY SHALL BE SCHEDULE 40 PVC. TRANSFORMERS ON 4"X4" JUNCTION BOX ABOVE ACCESSIBLE CEILINGS OR ELECTRICAL 23. ALL CONDUIT RUNS ARE SHOWN DIAGRAMMATIC. EXACT ROUTING SHALL BE DETERMINED ROOMS. IN THE FIELD, UNLESS OTHERWISE NOTED. 49. FOR RESIDENTIAL WORK PROVIDE COMBINATION TYPE ARC -FAULT CIRCUIT INTERRUPTER 24. WIREWAYS SHALL BE SIZED AS REQUIRED, PER NEC. UNLESS OTHERWISE NOTED (LION). PROTECTION THROUGHOUT THE DWELLING UNIT, EXCEPT IN KITCHEN BATHROOM, GARAGES AND OUTDOORS. ALL DWELLING UNIT RECEPTACLE OUTLETS MUST BE LISTED 25. WHERE CORE DRILLING OF FLOOR/WALLS IS REQUIRED, CONTRACTOR SHALL_ SEAL TAMPER-RESISTANT. OPENINGS WATERTIGHT AFTER UTILITIES HAVE BEEN INSTALLED. LOCATION OF CORED HOLES SHALL COORDINATE WITH LOCATION OF EQUIPMENT IN A MANNER TO BE CLEAN 5 0. PROVIDE U.L LISTED COMPOUND APPLIED TO BACK OF "BACK TO BACK" BOXES IN AND FUNCTIONAL THE CONTRACTOR SHALL INSTALL ONLY ONE CONDUIT PER HOLE AND RATED WALLS WHERE THE BOXES ARE LESS THAN 609.6MM (24 INCHES) APART SEAL THE OPENING AROUND THE CONDUIT AS SPECIFIED. MEASURED HORIZONTALLY. 26. PROVIDE FIRE RETARDANT U.L APPROVED SEALANT ON ALL PENETRATIONS OF FIRE 51. CONTRACTOR SHALL PROVIDE TYPED- WRITTEN. UPDATED PANEL DIRECTORIES ON ALL RATED PARTITIONS, WALLS AND STRUCTURAL SLABS. CONTRACTOR TO VERIFY, PRIOR TO PANELS THAT ARE AFFECTED AT THE COMPLETION OF THE JOB. SUBMITTING BID. LOCATIONS OF ALL SUCH FIRE RATED PARTITIONS, WALL AND STRUCTURAL SLABS. 52. FOR RECEPTACLES IN DAMP AND WET LOCATIONS THE CONTRACTOR SHALL_ PROVIDE ALL 27. UNLESS NOTED AS EXISTING, ALL EQUIPMENT, WIRING, DEVICES, ETC. SHALL BE NEW. 125V. AND 25OV., 15A. AND 20A. RECEPTACLES THAT ARE LISTED AS WEATHER RESISTANT TYPE TO COMPLY WITH NEC ARTICLE 406.8. GENERAL LIGHTING NOTES: 1. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF LIGHT FIXTURES. 2. COORDINATE TYPE OF CEILING FOR EACH FIXTURE WITH ARCHITECTURAL REFLECTED CEILING PLANS AND PROVIDE FIXTURE TRIM AS REQUIRED. 3. ALL COMPACT FLUORESCENT DOWNUGHTS SHALL USE LAMPS WITH 3500K TEMPERATURE. MINIMUM 10,000 HOUR LIFE, ELECTRONIC BALLAST, UNLESS OTHERWISE NOTED. 4. PROVIDE APPROVED FIRE RATED ENCLOSURES FOR ALL LIGHT FIXTURES LOCATED IN FIRE RATED CEILINGS. 5. FIXTURES IN AREAS WITHOUT CEILINGS, OR IN MECHANICAL AND ELECTRICAL ROOMS SHALL BE MOUNTED WITH 1 7¢"X1 WKINDORF CHANNEL SUPPORT SUSPENDED FROM ROOF STRUCTURE WITH THREAD RODS. FIXTURES SHALL BE MOUNTED 10' -0" A.F.F. 6. ALL ACRYLIC LENSED FIXTURES SHALL HAVE A LENS THICKNESS OF .125 INCHES MINIMUM. 7. HALF SHADED FIXTURES DENOTE EMERGENCY FIXTURES EITHER WITH 1100 LUMEN EMERGENCY BATTERY PACK OR ON LIFE SAFETY CIRCUIT. 8. LIGHTING FIXTURE SCHEDULE IS PREDICTED ON PERFORMANCE AND IS DESIGNED TO MEET CERTAIN AESTHETIC CRITERIA. ALL ALTERNATIVE SELECTIONS MUST BE SUBMITTED FOR PRIOR APPROVAL TEN (10) DAYS PRIOR TO BID DATE 9. ALL BALLASTS SHALL HAVE MINIMUM POWER FACTOR OF 0.90. ALL BALLASTS FOR METAL HALIDE AND HIGH PRESSURE SODIUM FIXTURES SHALL BE CONSTANT WATTAGE TYPE WITH + / -5X LAMP WATTS FOR + / -10X NOMINAL LINE VOLTAGE VARIATION. 10. PROVIDE LAMPS WITH FIXTURES, VERIFY LAMP TYPE WITH MANUFACTURER. 11. FLUORESCENT LUMINAIRES THAT UTILIZE DOUBLE -ENDED LAMPS AND CONTAIN BALLAST(S) OR MULTMIIRE BALLASTED LUMINAIRES SHALL CONTAIN AN INTEGRATED INTERNAL DISCONNECT AND TO BE COMPLIED WITH NEC 410.130(G). 12. ALL OPENINGS FOR LIGHT FIXTURES IN CEILINGS SHALL BE PROTECTED IN A MANNER (PER ALL GOVERNING CODES) THAT WILL PROVIDE THE SAME RATING AS THE CEILING. (THIS APPLIES TO ALL FIRE RATED CEILINGS). 13. FOR EMERGENCY EXIT SIGNS AND EMERGENCY BATTERY PACKS MAKE CONNECTION AHEAD OF ALL SWITCHES AND CONTROLS. 14, PROVIDE A FUSE HOLDER AND FUSE (BUSSMAN HEB AND FNQ OR EQUAL), IN THE PRIMARY SIDE OF EACH UNGROUNDED CONDUCTOR FOR ALL BALLASTS AT THE HAND HOLE OF EACH EXTERIOR POLE MOUNTED LIGHTING FIXTURE OR J -BOX FOR WALL OR GROUND MOUNTED FIXTURE 15. PROVIDE WIND LOAD RATED LIGHT POLES WITH 145 MPH MINIMUM WIND SPEED (ASCE 7). EXPOSURE C WITH IMPORTANCE FACTOR OF 1.0, AND PROVIDE PHOTOMETRICS WITH ALL FIXTURE SUBMITTALS. CONTRACTOR TO VERIFY VOLTAGES OF ALL LIGHT FIXTURES PRIOR TO BIDDING. 16, PHOTOMETRICS ARE BASED ON MANUFACTURER'S INFORMATION AND CATALOG NUMBERS. ALTERNATIVE MANUFACTURERS MUST PROVIDE THE IESNA FORMAT ELECTRONIC FILES OF THE INDEPENDENT TEST LAB REPORTS FOR THE PROPOSED FIXTURES ON CD OR FLOPPY DISKETTE 10 WORKING DAYS PRIOR TO BID. (SPECIFIER) WILL CONFIRM THAT THE PHOTOMETRIC CRITERIA HAS BEEN MET, AND IF ALTERNATE IS APPROVED WILL ISSUE AN ADDENDUM. MANUFACTURERS NOT LISTED ON THE PLANS OR IN AN ADDENDUM WILL NOT BE ACCEPTED. 17. TO CONFIRM THAT THE SPECIFIED PHOTOMETRIC CRITERIA HAS BEEN MET, A COMPUTER DISK CONTAINING AN IES FILE FOR THE PROPOSED ALTERNATE MUST BE SUBMITTED TO (SPECIFIER) FOR EVALUATION NO LESS THAT 10 DAYS PRIOR TO BID. ANY ACCEPTABLE ALTERNATE MUST BE APPROVED IN WRITING PRIOR TO BID DATE 18. CONTRACTOR MUST BID PROJECT USING SPECIFIED LIGHTING FIXTURES AS BASE BID (NO EXCEPTIONS). IF ALTERNATE FIXTURES ARE PROPOSED. THEY MUST BE BID AS AN ALTERNATE BID MUST INCLUDE: A) TOTAL DOLLAR CREDIT TO OWNER IF ALTERNATE IS ACCEPTED. B) LINE ITEM CREDIT FOR EACH ALTERNATE FIXTURE PROPOSED. C) CATALOG SUBMITTAL DATA FOR EACH ALTERNATE FIXTURE PROPOSED. 19. IF THERE IS A DISCREPANCY BETWEEN A FIXTURE DESCRIPTION AND GENERAL NOTES, AND THE CATALOG NUMBER LISTED, THE FIXTURE DESCRIPTION AND GENERAL NOTES SHALL GOVERN. 20. COORDINATE FIXTURE TYPES WITH ARCHITECTURAL DRAWINGS. ELECTRICAL SYMBOL LEGEND SYMBOL DESCRIPTION ' DESCRIPTION LIGHTING (REFER TO LIGHTING FIXTURE SCHEDULE) A LIGHT FIXTURE DESIGNATION. AE LIGHT FIXTURE WITH "E" SUFFIX DESIGNATION INDICATES EMERGENCY SECURITY SYSTEM KEYPAD BATTERY BACK -UP FOR A MINIMUM OF 90 MINUTES. CLOCK LIGHTING FIXTURE, SURFACE MOUNTED O LIGHTING FIXTURE (HID, FLUORESCENT OR INCANDESCENT), RECESSED MTD. 1T LIGHTING FIXTURE, WALL MOUNTED ® DOT LIGHT FIXTURE. DIRECTION ARROWS AS SHOWN I ® WALL MOUNTED EXIT LIGHT FIXTURE FLOOR OUTLET BOX AND DUPLEX RECEPTACLE 20 AMP.. 125V., WITH (SHADED QUADRANT INDICATES FACE(S) OF FIXTURE) O2 OUTLET BOX AND DUPLEX RECEPTACLE 20A, 125V. X 2 FLUORESCENT LIGHT FIXTURE DUPLEX RECEPTACLE, 20 AMP., 125V.. TOP HALF SWITCHED, M.H. - 2 X 4 FLUORESCENT LIGHT FIXTURE ® K]1/2 SHADED FIXTURE INDICATES FIXTURE TO BE PROVIDED WITH 90 MINUTE 1100 DUPLEX RECEPTACLE, 20 AMP.. 125V., ISOLATED GROUND AND SURGE LUMEN BATTERY BACK -UP FOR LINEAR FLUORESCENT FIXTURES AND 700 LUMEN PROTECTED, (M.H. =18" A.F.F.) BATTERY BACK -UP FOR COMPACT FLUORESCENT FIXTURES. EXISTING EQUIPMENT TO REMAIN 1 X 4 FLUORESCENT LIGHT FIXTURE NEW EQUIPMENT OR WORK OF THIS PROJECT FLUORESCENT WALL MOUNTED FIXTURE WITH WALL OUTLET BOX F-0­1 FLUORESCENT STRIP FIXTURE I--®--q DIAGONAL SHADING DENOTES LIGHT FIXTURE CONNECTED TO EMERGENCY SECURITY CAMERA J -BOX PROVIDE CONNECTION TO BRANCH CIRCUIT OR. W /EMERG. BATTERY PACK. ❑-0-0 EXTERIOR LIGHT FIXTURE WITH ARMS AS SHOWN ON DRAWINGS SYSTEM SPEAKER TOGGLE SWITCH 120/277V. 20 AMP.,(M.H. - 48" A.F.F.) $3 TOGGLE SWITCH 120/277V. 20 AMP. ,(M.H. = 48" A.F.F.) , 3 -WAY $4 TOGGLE SWITCH 120/277V. 20 AMP.. (M.H. - 48' A.F.F.). 4 -WAY $K TOGGLE SWITCH 120/277V. 20 AMP. KEYSWITCH. (M.H. = 48" A.F.F.) $F $T FAN SWITCH 120/277V. 20 AMP, HORSEPOWER RATED C - ABOVE THE COUNTER (VERIFY WITH ARCH DRAWINGS) 30- MINUTE ROTATABLE TIMER SWITCH (M.H. - 48" A.F.F.) $P TOGGLE SWITCH 120/277V. 20 AMP., WITH PILOT LIGHT. N - COMBINATION RECESSED POWER AND DATA RECEPTACLE (M.H.-48-A.F.F.) WALL BOX FOR CONNECTION TO N USING CLOSED CIRCUIT TOGGLE SWITCH 120/277V. 20 AMP. EXPLOSION- PROOF. DATA CABLE. MOUNTING HEIGHT IS +72" A.F.F UNLESS (M.H.- 480A.F.F.) $S SPEED SWITCH 120/277V. 20 AMP. U.O.N. ,(M.H. - 48" A.F.F.) $M SINGLE PHASE MANUAL MOTOR STARTER. (M.H. -48" A.F.F.) $O DIMMER SWITCH 120/277V. 20 AMP., (M.H. -48" A.F.F.) (1500 WATTS $30 UNLESS OTHERWISE INDICATED) � , A THREE -WAY DIMMER SWITCH (48' A.F.F.) ° SINGLE POLE SWITCH (48" A.F.F.) (SUBSCRIPT INDICATES ITEM to CONTROLLED) © PANIC SWITCH, MUSHROOM TYPE. (M.H. -48" A.F.F.) 9 a,b WALL MOUNTED - OCCUPANCY SENSOR SWITCH,(M.H.- 487A.F.F.) MFGR. /MODI CONNECTION, SEE SPECS. SENSOR SWITCH /#WSD -PDT SECURITY SYSTEM MONITORS AND RECORDERS, SEE SPECS. (a, b) OR (2) INDICATES TWO POLE SWITCH - WSD- PDT -2P I"lJ [DJ D INDICATES DIMMABLE ® CEILING MOUNTED OCCUPANCY SENSOR - LIGHTING CIRCUIT CONTROLLER. FUSE SIZE ( * DENOTES AS PER MANUFACTURER) MFGR. /MODEL# (SENSOR SWITCH /JCM -PDT) I CONTROL TIME CLOCK CEILING MOUNTED DUAL TECHNOLOGY EXTENDED RANGE OCCUPANCY E SENSOR - LIGHTING CIRCUIT CONTROLLER. SENSOR SWITCH / #CM- PDT -10. SHUNT -TRIP BUTTON - FLUSH MOUNTED UNLESS OTHERWISE NOTED WALL MOUNTED - OCCUPANCY SENSOR (M.H.= 967A.F.F.) PLUG -IN STRIP WITH RECEPTACLES, 18" O.C. UNLESS OTHERWISE INDICATED MFGR. /MODEL #WV -PDT Ea POWER PACK OCCUPANCY SENSOR N CONTRACTOR SHALL PROVIDE ALL SWITCHPACKS AND CONDUCTORS AS REQUIRED FOR LAYOUTS AND CONTROLS SHOWN ON PLANS. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE AND INSTALL A COMPLETE AND FULLY FUNCTIONAL LIGHTING CONTROL SYSTEM IN ACCORDANCE WITH THE PLANS. DETAILS, INTENT OF THE DESIGN AND SPECIFICATIONS SHOWN ON THESE PLANS. NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. SYSTEMS SYMBOL LEGEND BASIC MATERIALS ' DESCRIPTION ALL RECEPTACLES TO BE COMMERCIAL GRADE EXCEPT FOR THOSE CONNECTED CALL BACK PUSH BUTTON TO OR DESIGNATED AS EMERGENCY BY THE LETTER "F'. INCASE OF EMERGENCY CIRCUIT BREAKER, TYPE AND SIZE AS PER DRAWINGS. POWER, THE RECEPTACLES SHALL BE HOSPITAL GRADE AND HAVE THE COLOR SECURITY SYSTEM KEYPAD RED. THE COVERPLATE SHALL BE RED AND ENGRAVED WITH 1/4" HIGH LETTERS CLOCK AND SHOWN IN WHITE ON RED. (NO EVGRAVING REQUIRED FOR NORMAL POWER). E COMMERCIAL GRADE DUPLEX RECEPTACLE. 20 AMP., 125V., (M.H.- 187A.F.F.) 1T OAIR E - DENOTES EMERGENCY POWER CONNECTION, HOSPITAL GRADE RED WITH O RED COVERPLATE ENGRAVED WITH WHITE CIRCUIT NUMBER. ® FLOOR OUTLET BOX AND DUPLEX RECEPTACLE 20 AMP.. 125V., WITH APPROPRIATE FLANGE. OCEILING OUTLET BOX AND DUPLEX RECEPTACLE 20A, 125V. 19 DUPLEX RECEPTACLE, 20 AMP., 125V.. TOP HALF SWITCHED, M.H. - -------- -__ _ ---- _----------- 18" A.F.F. UNLESS OTHERWISE NOTED I[i] DUPLEX RECEPTACLE, 20 AMP.. 125V., ISOLATED GROUND AND SURGE ® PROTECTED, (M.H. =18" A.F.F.) (� EXISTING EQUIPMENT TO REMAIN SINGLE RECEPTACLE, 20 AMP., 125V.. COORDINATE M.H. WITH NEW EQUIPMENT OR WORK OF THIS PROJECT T EQUIPMENT. `j)EWC TELEPHONE /COMPUTER TERMINAL BOARD 'ITB" SIMPLEX RECEPTACLE (16" A.F.F.) (EWC DENOTES ELECTRIC WATER SECURITY CAMERA J -BOX PROVIDE CONNECTION TO COOLER. COORDINATE WITH EWC INSTALLER FOR MOUNTING HEIGHT) fTWO DUPLEX RECEPTACLES WITH COMMON COVER 20A., 125V.,(18- SYSTEM SPEAKER A.F.F.) ® T SPECIAL PURPOSE OUTLET e.g. RANGE OUTLET. COORD. W/ EQUIPT. JACKS IN A� GANG BOX WITH 2X42 RING MOUNTED AT DUPLEX RECEPTACLE, 20 AMP., 125V.. MOUNT ABOVE COUNTER 044 "OFF. V OR +42" AFF FOR EXAM ROOMS (REFER TO ARCHITECURAL DRAWINGS AND ACCESSIBLE CEILING SPACE. ELEVATIONS FOR EXACT MOUNTING HEIGHT, ORIENTATION AND LOCATIONS. GFCI DUPLEX RECEPTACLE, 20 AMP., 125V.. (M.H.- 18- A.F.F.) C - ABOVE THE COUNTER (VERIFY WITH ARCH DRAWINGS) } GFCI DUPLEX RECEPTACLE, 20 AMP., 125V., MTD. ABOVE COUNTER OR `T1'' N - COMBINATION RECESSED POWER AND DATA RECEPTACLE MOUNTED HIGH. VERIFY HEIGHT BEFORE ROUGH IN. WALL BOX FOR CONNECTION TO N USING CLOSED CIRCUIT TWO DUPLEX GFCI RECEPTACLES WITH COMMON COVER 20A., 125V., DATA CABLE. MOUNTING HEIGHT IS +72" A.F.F UNLESS MTD. ABOVE COUNTER OR MOUNTED HIGH. VERIFY HEIGHT BEFORE OTHERWISE NOTED. ROUGH IN. 0 30 AMP.. 125V., TWIST LOCK RECEPTACLE FOR FLOOR POLISHING MACHINE Q JUNCTION BOX, MOUNTING AS SHOWN I0 POWER POLE � , A M4 EMERGENCY SOUNDER /STROBE LIGHT. ELECTRIC MOTOR, NUMBER INDICATES HORSEPOWER to MAGNETIC MOTOR STARTER OR CONTACTOR, lVU COMBINATION MAGNETIC MOTOR STARTER, SIZE AS NOTED SECURITY SYSTEM CAMERA. PROVIDE POWER AND SIGNAL DISCONNECT SWITCH, SIZE AS NOTED CONNECTION, SEE SPECS. III OF POLES ENCLOSURE TYPE- SECURITY SYSTEM MONITORS AND RECORDERS, SEE SPECS. AMP RATING /FRAME NEMA 3R- FOR EXTERIOR I"lJ [DJ 310;fUGM NEMA 1- FOR INTERIOR vS FUSE SIZE ( * DENOTES AS PER MANUFACTURER) I CONTROL TIME CLOCK ® PHOTOCELL. MOUNTED ON ROOF FACING NORTH ® SHUNT -TRIP BUTTON - FLUSH MOUNTED UNLESS OTHERWISE NOTED ® PLUG -IN STRIP WITH RECEPTACLES, 18" O.C. UNLESS OTHERWISE INDICATED ® CABLE TRAY (ROUTING TO BE COORDINATED WITH ALL TRADES) III- GROUND OR GROUND ROD AS NOTED -O CONDUIT TURNING UP -0 CONDUIT TURNING DOWN ] CONDUIT STUB "Z CONDUIT CONTINUED NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. SYSTEMS SYMBOL LEGEND SYMBOL ' DESCRIPTION Ei CALL BACK PUSH BUTTON CIRCUIT BREAKER, TYPE AND SIZE AS PER DRAWINGS. 2 SECURITY SYSTEM KEYPAD Ec CLOCK ❑ BELL FEA$ID 48100 - OAIR HANDLING UNIT SHUT -DOWN RELAY O POWER ON INDICATOR WITH KEYED RESET .(. SERVICE AND DISTRIBUTION ELECTRICAL BRANCH CIRCUIT PANELBOARD. RECESS MOUNTED. ............................ (SEE PANEL SCHEDULE FOR DETAILS) ........ lIlll1lllllllll....... ELECTRICAL BRANCH CIRCUIT PANELBOARD, SURFACE MOUNTED. -------- -__ _ ---- _----------- (SEE PANEL SCHEDULE FOR DETAILS) I[i] I TRANSFORMER. SIZE AS NOTED ® AUTOMATIC TRANSFER SWITCH •. ............. °• •. EXISTING EQUIPMENT TO REMAIN NEW EQUIPMENT OR WORK OF THIS PROJECT TELEPHONE /COMPUTER RACEWAY SYSTEM ® TELEPHONE /COMPUTER TERMINAL BOARD 'ITB" © SECURITY CAMERA J -BOX PROVIDE CONNECTION TO SECURITY POWER SUPPLY AND VIDEO SUPPLY. OINTERCOM SYSTEM SPEAKER COMPUTER - - HONE OUTLET WITH MUD JACKS IN A� GANG BOX WITH 2X42 RING MOUNTED AT 18" A.F.F. PROVIDE 1" CONDUIT STUBBED 6" ABOVE ACCESSIBLE CEILING SPACE. C - ABOVE THE COUNTER (VERIFY WITH ARCH DRAWINGS) W = WALL MOUNTED (48" A.F.F./VERIFY WITH ARCH DWG) N - COMBINATION RECESSED POWER AND DATA RECEPTACLE WALL BOX FOR CONNECTION TO N USING CLOSED CIRCUIT DATA CABLE. MOUNTING HEIGHT IS +72" A.F.F UNLESS OTHERWISE NOTED. ® DATA/TELEPHONE PORT - CEILING MOUNTED is DATA/TELEPHONE PORT - FLOOR MOUNTED SPECIALTY DEVICES - SYSTEMS EMERGENCY PULLSTRING BOX M4 EMERGENCY SOUNDER /STROBE LIGHT. <C>--j NURSE CALL DOME LIGHT SECURITY SYSTEM SECURITY SYSTEM CAMERA. PROVIDE POWER AND SIGNAL CONNECTION, SEE SPECS. SECURITY SYSTEM MONITORS AND RECORDERS, SEE SPECS. ® SECURITY SYSTEM CARD READER, SEE SPECS. -' • j' SECURITY SYSTEM CABLES IN CONDUIT. SEE SPECS. vS SECURITY SYSTEM JUNCTION BOX AT ACCESSIBLE LOCATION. SECURITY SYSTEM HIDDEN PUSH BUTTON FOR DOOR STRIKE • RELEASE, COORDINATE INSTALLATION WITH FURNITURE OR EQUIPMENT. ® SECURITY SYSTEM SPEAKER WITH INTEGRAL MICROPHONE ❑� SECURITY SYSTEM KNOX BOX NOTE SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJE ABBREVIATIONS A.C. ABOVE COUNTER IX EXISTING A.F. ARC FAULT ER EXISTING RELOCATED A.F.F. ABOVE FINISHED FLOOR G.F.I. GROUND FAULT INTERRUPTER A.S.W. ABOVE SHOW WINDOW RCPT. L.C. LOCKABLE COVER B.F.C. BELOW FINISHED CEILING M.H. MOUNTING HEIGHT B.F.G BELOW FINISHED GRADE N NEW DEVICE C.B. CIRCUIT BREAKER N.F. NON FUSED CL CENTER LINE NL NIGHT LIGHT D DEDICATED FOR COMPUTER, R EXISTING TO BE REMOVED PROVIDE DEDICATED GROUND AND NEUTRAL T.C. TERMINAL CABINET IG ISOLATED GROUND (ORANGE T.S. TIME SWITCH DEVICE) U.O.N. UNLESS OTHERWISE NOTED EM PROVIDE EMERGENCY BATTERY PACK W /FIXTURE, WR. WATER RESISTANCE RECEPTACLE CONNECT AHEAD OF ALL SWITCHES. XFMR. TRANSFORMER. WP. WEATHER PROOF ENCLOUSURE RR REMOVE AND RELOCATE X DETAIL - , SHEET NUMBER NOTE SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJE NQg; MULTIWIRE BRANCH CIRCUITS REQUIRE DISCONNECTING MEANS AS PER NEC 219.4d OM RECEPTS. IN ALL EXAM ROOMS AND TREATMENT ROOMS ARE TO BE HOSPITAL QUALITY WITH REDUNDANT GROUND SYSTEM AS MANDATED BY N.E.C. 517. ELECTRICAL INDEX : - - - _ - - : _ _ - - ; z ---------- - _ ----------------------------•-----------------_--.-------------------..-•------------------ •- •- •---------- - - - - -- - - - DBA1[hNLG _ _ _ ........................ ....... ....... ........ .... • -. ,.. 1 E1.1 ELECTRICAL INDEX, SYMBOL LEGEND AND NOTES. ; - - ' `•. - - - --- •--- - - - - -- ••...... -- L - - -- - - - -- 2 E2.0 ELECTRICAL SITE PLAN - - _ - - - - - - -- ----------•------------------....--------------------...---------------•---•-•------------------.........------------------.-. ....------------------- •- - - - - -- ...A ----------- ....-- •-- •-- •----- •- - - - - -- -------- --- -� -- - - 3 E2.1 FIRST FLOOR OVERALL ELECTRICAL PLAN -••---------±------•--------------------••---------------- •-- •------------ - - - - -- - -s--- - E2.2 SECOND FLOOR OVERALL ELECTRICAL PLAN - ' 5 I E2.3 THIRD FLOOR OVERALL ELECTRICAL PLAN i ----•-+---------------------•-•----------------------•- •---•--------------------•-•---------------------------•--------------------- •- ;----- •------ •------- - - - - -- •••--- - - - - -- 6 E2.4 FOURTH FLOOR OVERALL ELECTRICAL PLAN --------------4i ------------------------------------------------------------------------------------------------- 7 E3.1 a PARTIAL FIRST FLOOR POWER PLAN ------ I---••-------------------------------------•---------------------------------------------------------------- - - - - -- • -.. 8 E3.1 b PARTIAL FIRST FLOOR POWER PLAN ----.-------------------------------------------•-------------------..---•-----------------------•-- •---------------------- -•• - -- -• -• - - -- ¢-- - - - - -- - - - - -- 9 E3.1 c PARTIAL FIRST FLOOR POWER PLAN - •---- - - - - -- -----••---•----------------•--••---•-----------------••------------------------- •----------------- - - - - -- - ...... -i ------ •----- - - - - -, ----- - - - -•- 10 + E3.1 d PARTIAL FIRST FLOOR LIGHTING PLAN ............................................................................ ............................... ..................;.........._. �.._._._.._.._h......._. 11 '; E3.1a PARTIAL FIRST FLOOR LIGHTING PLAN ; ; • ` ` - ----------------- I- ------- --- ----- -- ------ -- ------ - ----------------------- - -------------------------- --- ---- ------- .--. ---- -------- -- --- - --- 14 E3.4a FOURTH FLOOR POWER PLAN -- - - - - -- ----------------------------•----•------------------•--•----------------------------------------- ---- --•- - - - - -- ••---------------- 15 i E3.4b FOURTH FLOOR POWER PLAN • . -- .............. :............................................................................................................................................ ............................... ............ • ...___ ................ 16 E3.4c FOURTH FLOOR LIGHTING PLAN --------- I-•-----------------•-•----------------------••--•------------------•------------------------- ••- •------------------- - - - - -- --------------------------------------------------- •-------------------- - - - - -- 1. ----------------------------------- 17 E3.4d FOURTH FLOOR LIGHTING PLAN - - -- -----------------------------------------------------•-----------------•-••-•--------------------------- ....--------- - - - - -- •- ...... - ............... --------•-----------------------••---------------.....-•-•----------r-------- I.. 18 ; E3.5 ROOF ELECTRICAL PLAN - t ..... .. ...... ------------------------------------------------------------------------------------------------ - - - - -- -------------------------------------------------------------------- - - - - -- - -- ' ----------+----•--- 19 E4.1 ELECTRICAL RISER DIAGRAM ..............:............................................................................................ ............................... . .......................................................................... ............................... 20 :: E4.2 ELECTRICAL PANEL SCHEDULES ------- - - - - -- ---------------------------------------------------••---------------•--•---•----•---------------......----•------------•--...-•------------------•----•------------------------- •- •--------- - - - --- ...... r.....- - - - -•. 21 E4.3 LIGHT FIXTURE SCHEDULE -___•-------{--------------------------------•----------------••_•---------------------------------------------------- - - - - -- - - - - -- E5.1 ELECTRICAL DETAILS i • • SHOP DRAINING REQUIREMENTS 1. CONTRACTOR SHALL SUBMIT 6 COPIES OF COMPLETED S� OP DRAWINGS, TOGETHER AT ONE TIME AND MUST COME THROUGH THE ARCHITECT. ALL SUBMITTALS SHALL BE MADE WITHIN 30 DAYS OF NOTICE TO PROCEED. 2. ALL SUBMITTALS MUST CLEARLY INDICATE EXACTLY WHIC ITEMS ARE BEING PROPOSED FOR USE. IF NOT. THE SUBMITTAL SHALL BE REJECTED. 3• SUBSTITUTIONS SHALL BE LIMITED TO ONE OF THE ALTERNATES LISTED IN THE CONSTRUCTION DOCUMENTS. PRODUCTS CONSIDERED TO BE EQUAL SHALL BE REVIEWED AND ACCEPTED BY THE ENGINEER, ARCHITECT AND OWNER (10) DAYS PRIOR TO BID DATE. 4. THE CONTRACTOR ASSUMES ALL DESIGN RESPONSIBILITY AND ALL FINANCIAL RISKS FOR PROCEEDING PRIOR TO SHOP DRAWINGS PROCESSING, AND ON ANY ITEM OR WORK THAT IS AT VARIANCE TO THE CONSTRUCTION DOCUMENTS. 5• SHOP DRAWINGS AND SUBMITTALS FOR EACH ITEM SHALL BE REVIEWED NO MORE THAN TWICE A THIRD SUBMITTAL ON AN ITEM MUST BE ACCOMPANIED BY A PURCHASE ORDER FROM THE CONTRACTOR OR IT SHALL BE REJECTED. 6. CIRCUMSTANCES NECESSITATING A REVISION TO THE PERMITTED DOCUMENTS NOT PROCESSED PRIOR TO INSTALLATION MAY NOT BE ACCEPTED. IF ACCEPTED IT MUST BE LEGIBLE, ACCURATE AND ACCOMPANIED BY A PURCHASE ORDER ORDER FROM THE CONTRACTOR. THE REVISION SHALL BE CHARGED TO THE CONTRACTOR AND DELIVERED TO HIM ON A C.O.D. BASIS. 7. SUBSTITUTIONS FROM THE BASE DESIGN OR VARIATIONS TO THE PERMITTED CONTRACT DOCUMENTS, WHETHER RESULTING FROM PROCESSED SHOP DRAWINGS OR NOT, THAT RESULT IN REQUIREMENTS IN LETTERS OF AUTHORIZATION AND /OR PERMIT CONTRACT DOCUMENT CHANGES MANDATED BY THE AUTHORITY HAVING JURISDICTION WILL NOT BE MADE BY THIS OFFICE UNLESS ACCOMPANIED BY A PURCHASE ORDER FROM THE CONTRACTOR. AND RELEASED ON A C.O.D. BASIS. 8. CONTRACTOR SHALL SUBMIT 5 COPIES OF EQUIPMENT LAYOUTS OF ALL ELECTRICAL SPACES, ROOMS, ETC. TO THE ENGINEER FOR APPROVAL PRIOR TO ORDERING EQUIPMENT OR INSTALLING CONDUITS. ETC. THE LAYOUTS SHALL CONSIST OF PLAN VIEWS AT A SCALE OF 1/2" - 1'0" AND ELEVATIONS FOR EACH SUCH SPACE OR ROOM, ETC. NOTE: ALL MATERIALS USED IN CEILING SPACE SHALL BE PLENUM APPROVED TYPE (IF REQUIRED). ALL ELECTRICAL RECEPTACLES AND SWITCHES ARE TO BE LABELED MECHANICALLY WITH PANEL CIRCUIT NUMBER. ALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING CODES AND STANDARDS: FLORIDA STATE FIRE MARSHALL'S RULE 69A -3.012 FAC AND RULE CHAPTER 69A -60 FLORIDA ADMINISTRATIVE CODE (FAC) AND FLORIDA STATUTE SECTION 633.022. THE 2010 FLORIDA BUILDING CODE THE GUIDELINES FOR DESIGN AND CONSTRUCTION OF HEALTH CARE FACILITIES (AA1 GUIDELINES, FGI GUIDEUNES, 2006 EDITIONS) THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) CODE 99 (2005 EDITION) THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) CODE 70 (2008 EDITION) THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) CODE 110 (2005 EDITION) THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) CODE 72 (2007 EDITION) THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) CODE 780 (2011 EDITION) THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) CODE 101 (2009 EDITION) �E�LECTRICAL SYMBOLS SHOWN ARE DIAGRAMATIC. • DO NOT SCALE PLANS. • COORDINATE EXACT LOCATIONS OF OUTLETS WITH FURNITURE COMPANY SHOP DRAWINGS. • COORDINATE EXACT HEIGHT OF OUTLETS WITH ARCHITECTURAL INTERIOR ELEVATIONS AND CABINET SHOP DRAWINGS. DEMOLITION NOTES 1. It shall be the responsibility of the contractor 'to remove existing equipment as required to accomplish the new work. 2. When removing electrical equipment and systems, all precautions shall be taken. 3. The contractor shall exercise care so that only that construction Indicated or reasonably Imptled to be removed shall be demolished. 4. The contractor shall be responsible for the removal of all demolition and construction debris generated from work. 5• The contractor shall coordinate all power Interruptions with owner. 6. Remove all miscellaneous fixtures and equipment retaining Items to be Identified for salvage and storage at the direction of the owner. 7. The contractor shall be res o slble f r the rem v t fall fluores nt and HID type lumps and proper dlspoga� of sal c� lamps nno� s�`inl4 provide verl�cntlon of lamp disposal to the owner upon request. .` �r I_, - I I—- 71: - _'- ___ 0 Design Services For The Built Environment E Atlanta Birmingham Cincinnati Columbus Dallas Fort Lauderdale Knoxville Jackson Jacksonville Louisville Memphis Nashville Richmond Tampa 0 G R E S H A M S M I T H A N D P A R T N E R S 6030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 9 54.9 81.9100 FIRM'S FLORIDA CERT. NO, AAP000034 /CA3806 IB26000797/LC26000381 707 N.E. 3rd AVE., SUITE 200 FORT TAUDERDATE, FL 93304 , 954) 527 -1112 CA/00009181 PJT. YGR: llaCBAEL BOO PROJECT & 120717 I No. - Date - Revision I ELECTRICAL INDEX, SYMBOL LEGEND AND NOTES E1.1 FILE: PROJECT: 29080.00 DATE: 11/29/2012 6100 ! • s `' • , '; ; GEORG AI4j pX. FEA$ID 48100 - 'DATE: . C k9,{E�3 :. .�� � .(. t0. ea ...... REVI I SON I No. - Date - Revision I ELECTRICAL INDEX, SYMBOL LEGEND AND NOTES E1.1 FILE: PROJECT: 29080.00 DATE: 11/29/2012