Loading...
13-96 (2)-105__■ P7 P6 D -P-a S7 P5 P4 P3 P2 P1 n DP _ �P 'r^�••'r P SD1 S6 S5 S4 S3 S2 S1 PW 2P 2P �CO 2P 2E �E CONTROL MODULE SE3 Z SE1 2 E SE4 '. �2 E SE2 2 E, RPS 110CD 11 A59 A60 A61 A62 15CD 75CD 75CD 7500 A54 A55 A56 A57 A58 75CD 75CD 75CD 75CD 75CD 75CD 75CD 75CD 75CD 75CD 11000 A63 A64 A65 A66 A67 A66 A69 A70 A71 A72 A73 75CD A45 A46 A47 A48 A49 75CD 75CD 75CD 75CD A50 A51 A52 A53 75CD A36 A37 A38 A39 A40 75CD 75CD 75CD 75CD A41 A42 A43 A44 75CD 75CD Al A2 A3 A4 A5 AS A7 AS A9 75CD 75CD 75CD 75CD 75CD 75CD 75CD 75CD 75CD 75CD 75CD 75CD 75CD A10 All Al2 A13 A14 A15 A16 A17 A18 A19 A20 A21 A22 75CD 75CD 75CD 75CD 75CD 75CD 75CD 75CD 75CD 75CD 75CD 75CD 75CD A23 A24 A25 A26 A27 A28 A29 A30 A31 A32 A33 A34 A35 FIRE ALARM SYSTEM WIRE SCHEDULE: MAIN FIRE ALARM RPS FIRE ALARM SYSTEM SHALL BE POWER LIMITED CONTROL PANEL FAANS (FACP) 50W • INITIATING CIRCUITS: 4 CONDUCTOR, X18 AWG SOLID, SHIELDED TWISTED PAIR 2 • INDICATING CIRCUITS: 2 CONDUCTOR, #14 AWG 4 SOLID, SHIELDED CABLE NOTES: 1. PROVIDE PLENUM RATED FIRE ALARM CABLE WHERE REQUIRED. 3 2. VERIFY IF EXISTING FA SYSTEM CAN INTERFACE -_ WITH THIS NEW BUILDING'S FA SYSTEM. 3. ALL CONTROLS FOR ALARM SYSTEM SHALL BE AT MAIN PANEL KEY NOTES: 4 PROVIDE 2" EMPTY CONDUIT FROM FIRE ALARM O 1 FLOW AND TAMPER DEVICES AS INDICATED ON 2 EXTEND 3/4 " EMPTY CONDUIT FROM FIRE ALARM 3 #6 TO MAIN BUILDING GROUND. CONTROL PANEL TO EXISTING SYSTEMS HANDHOLE. O THE FIRE SPRINKLER SYSTEM DRAWINGS. O COMMUNICATOR TRANSMITTER TO MAIN TELEPHONE O BACKBOARD. O WITH EXISTING NOTIFIER FIRE ALARMSYSTEM. F ORE ALAF7IM R I S NOT 70 SCALE DIaG�HM (SORE ALARM SYSTEM NOTES 1. THE MAIN FIRE ALARM' CONTROL PANEL SHALL BE A MICROPROCESSOR BASE SYSTEM WITH ADDRESSABLE, INTELLIGENT DETECTORS. ADDRESSABLE CONTROL RELAY AND MONITOR MODULES, VISIBLE AND AUDIBLE SYSTEM ANNUCIATORS AND OTHER SYSTEM CONTROLLED DEVICES AS REQUIRED. 2. PROVIDE REMOTE POWER SUPPLY AS INDICATED FOR EACH FLOOR FOR FUTURE TENANT BUILDOUT. THE FIRE THE FIRE ALARM SHALL BE CAPABLE OF FUTURE EXPANSION AS REQUIRED IN THE TENANT TENANT SPACES. 3. ALL WIRING AND CONDUIT TO CONFORM TO N.F.P.A. 72 AND N.E.C. ARTICLE 760. WIRING SHALL BE SOLID COPPER OR STRANDED COPPER WITH A MAX. OF 7 STRANDS FOR 16 GA AND 18 GA, STRANDED COPPER WITH A MAX. OF 19 STRANDS FOR SIZES 14 AND LARGER AS RQUIRED BY N.E.C. 760 AND N.F.P.A. 70. 4. ALL FIRE STOP PENETRATIONS SHALL BE MADE WITH APPROVED (NEC) METALLIC CONDUIT AND SHALL BE SEALED WITH A U.L. APPROVED FIRE STOP MATERIAL. (SEE FIRE STOP DETAIL) 5. ROUTING OF THE FIRE ALARM SYSTEM CONDUIT IS DIAGRAMMATIC ONLY, VERIFY EXACT LOCATIONS PRIOR TO STARTING WORK. 6. ALL FIRE ALARM VISUAL SIGNAL (STROBES) SHALL ACTIVATE UPON INITIATION OF THE GENERAL ALARM. 7. ALL FIRE ALARM VISUAL SIGNALS IN OPEN AREA SHALL HAVE A THREE PLUS TEMPORAL PATTERN. B. ALL FIRE ALARM AUDIBLE SIGNALS SHALL HAVE A SOUND LEVEL OF AT LEAST 15 dba ABOVE THE AVERAGE ABMBIENT SOUND LEVEL. 9. MANUAL STATIONS SHALL BE INSTALLED AT 48" INCHES A.F.F. 10. MOUNT FIRE ALARM SYSTEM HORN /STROBES SUCH THAT THE ENTIRE LENS IS 80" A.F.F. OR 6" BELOW CEILING, WHICH EVER IS LOWER. 11. MOUNT FIRE ALARM SYSTEM STROBES SUCH THAT THE ENTIRE LENS IS 80" A.F.F. OR 6" BELOW CEILING, WHICH EVER IS LOWER. 12. SMOKE DETECTORS TO BE INSTALLED AS REQUIRED BY N.F.P.A. 72. 13. THE FIRE ALARM PANEL SHALL HAVE AN EARTH GROUND CONNECTION AS REQUIRED BY THE SYSTEM MANUFACTURER, AND N.E.C. ARTICLE 760. MINIMUM WIRE SIZE IS 8 AWG FOR GROUND CONNECTION. (NOTE PANEL NEUTRAL OR CONDUIT GROUND IS NOT ACCEPTABLE 14. A GENERAL ALARM SHALL BE ANNUNCIATED UPON ACTIVATION OF ANY PULL STATION, FLOW SWITCH OR DETECTION DEVICE. 15. A TROUBLE SIGNAL SHALL BE ANNUNCIATED UPON FAILURE OR REMOVAL OF ANY DETECTION OR MANUAL DEVICE. 16. A SUPERVISORY SIGNAL SHALL BE ANNUNCIATED UPON ACTIVATION OF ANY FIRE SPRINKLER SYSTEM TAMPER SWITCH. 17. HVAC DUCT SMOKE DETECTORS SHALL BE CONNECTED TO THE FIRE ALARM CONTROL PANEL AND SHALL INITIATE A SUPERVISORY SIGNAL ONLY. 18. FIRE ALARM SYSTEM SHALL BE U.L CERTIFIED. 19. ALL FIRE ALARM INITIATING DEVICES SHALL BE ADDRESSABLE AND ALL FIRE ALARM CIRCUITS SHALL BE CLASS "B ", STYLE "4" SLC AND CLASS "B" STYLE "Y" NAC CIRCUITS. 20. PROVIDE CERTIFICATE OF COMPLETION AT THE FINAL INSPECTION OF THE FIRE ALARM SYSTEM. 21. PROVIDE THE OWNER WITH A COMPLETE FIRE ALARM SYSTEM AND INSTALLATION MANUAL COVERING MANUAL COVERING ALL SYSTEM EQUIPMENT INSTALLED FOR THIS PROJECT. KEEP AT THE MAIN FIRE ALARM CONTROL PANEL 22. ALL PULL STATIONS TO HAVE UL LISTED COVERS. 23. ALL STROBE LIGHTS SHALL COMPLY WITH NFPA 72 24. MINIMUM RADIO SIGNAL' STRENGTH AS REQ'D BY AHJ SHALL BE MAINTAINED PER FFPC NFPA 1 11.3.1.3. RADIO SIGNAL STRENGTH MUST BE THE SAME FOR INSIDE AND OUTSIDE OF THE BUILDING. PROVIDE AN AMPLIFIED ''I SYSTEM TO MEET MINIMUM RADIO STRENGTH AS REQUIRED BY AHJ. DO 1^i ,a FIRE ALARM RISER DIAGRAM, BATTERY CALCULATIONS, AND NOTES SCALE: N.T.S. Design Services For The Built Environment ■ Atlanta Birmingham Cincinnati Columbus Dallas Fort Lauderdale Knoxville Jackson Jacksonville Louisville Memphis Nashville Richmond Tampa 0 G R E S H A M S M I T H A N D P A R T N E R S 6030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 954.981.9100 FIRM'S FLORIDA CERT. NO. AAP000034 /CA3806 IB26000797/LC26000381 707 N.B. 3rd AVE., SUrrZ 200 FORT LAUDF.RDMZ, FL 39304 , 954) 527 -1112 CA #00009181 PJT. NOR: iaCHAEL H00 PRGn= #: 120717 •- W M LLJ 4 oo, 0 gr 32 � Fz a n L_ <t Lo r \\ i(3 cr) Lc) I- LL.I O Sam W v 46 0 `• N0 Cr p I T F •wr 100 1 2 •yefl. REVISION No. - Date - Revision .......... ................................................ ................. ... ..�''"�: .�•. N ----------- --------;.. ----- ..........! . - - -.. _`:___ - - - - -- j C t a I • E i FIRE ALARM RISER DIAGRAM AND BATTERY CALCULATIONS FA3nl FILE: PROJECT: 29080.00 DATE: 11/29/2012 F RE ALARM CEATTERY CALCULATMN - - - ----------------------- ITEM - --- _ ....... -- ---------- - - - - -- ----------------------------------- - - - - -- - - - - -- - -- --------------- DESCRIPTION - - - - -- STANDBY - QTY TOTAL ALARM QTY TOTAL CURRENT STANDBY CURRENT I ALARM i PER UNIT CURRENT PER UNIT CURRENT (AMPS) PER ITEM (AMPS) (AMPS) (AMPS) -------- -------- - - - - -- --------------- ❑- P - - - - -- ------- - - - - -- ----------------- - - - - -- -------------- - - -_ -• •--------------------------------- - - - - -- ---------------- MANUAL PULL STATION - - - - -- - - ! .0 - - - -- ---- - - - - -- ---- - - - -- -- ------- - - - - -- - - - -t X 11 _ .0 .000230 X 11 = .00253 i I-- ; - i O P - -- -- - - - - - - -- - - - PHOTOELECTRIC SMOKE DETECTOR ; 000230 � - - - - -- - -- - - - - -- - - - - - -- - - - -- -------------------- X _ _ 8 .00184 .0065 X 8 .052 - - 2 E - - -- - - -- - -- - -- - - - - - - ELEVATOR PHOTOELECTRIC SMOKE DETECTOR ; ; - - , -- - -- - , _ .000230 ±-------- - - - - -- - = - - - - - -- - - - - -- ------------ - - - - -+ i ; X 13 = .00299 .0065 X 13 = .0845 E E - ! 2 00 --------- - - - - -- --------------------- - - - - -- ------ - - - - -- ----- - - - - -- - -- -- DUCT DETECTOR - - - - ; .015 - - - X ! 2 _ .03 .012 X 2 = .024 i i O HEAT DETECTOR i .00015 i -.___ ' _ _ X i 3 .00045 .005 X 3 .015 FRCP .............. -° - •-- -------- ---- - ------------------ - - -- - FIRE ALARM CONTROL PANEL ----- - - ---- - •-- ---- - ----- ----- - - - _ - - .15 X 1 1 15 X 1 ----------- ------------------ ® i - ----- - --- - --- ---------- - -_ - -- - - --- ----------- - ------------ - --------- - - - - -- ----------------------- FIRE ALARM SYSTEM POINT ANNUNCIATOR ------- !------ - - - - -- --------- - - - - -- - ' .04 ----- - - - - -- -------------- - ------------------------------ - ---------- - - - - -- - - - - -- -- - - - - -- X 1 = .04 X 1 = --------------------- - - ! FAANS -- ----- - -- --- - ---- --- ---- ---- -- - -- - -- --------------------- ---- ---- •- •- __ ------- -------- ---------- ----- -- --- -- --- ---- --- -- -- -- ALARM COMMUNICATIONS ANNUNCIATOR - -- - -- - - - -- - - I .056 - - - - - • = _ 1 .1 X 1 .056 - ............ - - -° - - - - - - -- -- - -- - - --------- _1 - - - ----- -____- --- -------- _X .17 - -------- --- ---•-- -------------•-•-- ----- ----------- ------------ - - - --- ---------- i .17 ------------- --- + ; ; STROBE (75 CANDELA) .0 X 44 = 0 .123 X 44 = 5.412 �Q`75 E -� -- - -- -- -- - - -----------•••---- -- --- --- -- --- --- -- ------ -- -•-- - ----------------- ----- -- --- --- ---- ------ -- STROBE (110 CANDELA) - - - -_• ----- --- --1--- ----- --- - -- --- -- --- -- ------- - - -- .0 :___ -- - -- - - - - --- -- ---•----- •- - - - --- - - -- - X 1 = 0 .140 X 1 = - - �Q�m ; - - - -------------- - - --------------- - - - - -- - ---------------- - - - - -- ------------------------ - - - - -- -- - - - - - - ------- i - - - - -- - -- = - - .140 - - i------- - - - - - -- ------------- - - - - -- ---- - - - - -- -------------- - - - - -- ------------------------ - - - - -- - -- - - - - - - - - ------------------------------------------------ --------------------- - - - - -- --------------------------------- - - - - -- ---------------- - - - - -- - ------------------ TOTAL SYSTEM 03 TOTAL SYSTEM . 6.1 -....................................... -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- STANDBY CURRENT (AMPS) ALARM CURRENT (AMPS) !--------------------------- -------------------------------------------------------------------- REQUIRED OPERATING TIME 'OF SECONDARY POWER SOURCE FROM NFPA 72 1- 5.2.5: - - - - - ------------------------- STANDBY: 24 HOURS ALARM: 5 MINUTES X 1/60 = 0.0833 HOURS ------------ - ...... - ---------------------------------- - ----------------------------- •---------------------------- REQUIRED TOTAL SYSTEM ------------------------------------- -------------- ............... REQUIRED REQUIRED - ------------------------------------- • ---.-.._..- ........................................ ;TOTAL SYSTEM REQUIRED STANDBY STANDBY STANDBY I ALARM I ALARM ALARM TIME CURRENT CAPACITY i 1 TIME 1 CURRENT CAPACITY (HOURS) (AMPS) (AMP - HOURS) (HOURS) (AMPS) (AMP - HOURS) ---- - - - - -- -- - - - - -- - - - - - - -- - ------- ---------- - - - -_. --------- I------ - - - - -- -- - - - - -- - - - - - -- ------ - - - - -- - ------- -_ - - -- - - -- - - - -- - - - -- --- - - - - -- - - -- - - - -- --------------------------- -- 24 X 0.3 I = 7.2 0.0833 X 6.1 = 0.5081 ----------------------------------- T-----------,------------------------------------- REQUIRED REQUIRED T-------- -• - - -- __ ----- ----------------- -- -- - - - - i REQUIRED -- ------------ - - - - -- -- - - - - -- ------------ DERATING I MINIMUM STANDBY ALARM AMPERE HOUR FACTOR O AMP -HOUR CAPACITY CAPACITY BATTERY 1 1.2 BATTERY (AMP - HOURS) (AMP - HOURS) REQUIRED ------- -- ------------------------ - ------------ _i_ ----- --------- - - - - + - - 7.2 + 0.5081 _ 7.7081 X __1.2______ -_ - 9.2497 FIRE ALARM RISER DIAGRAM, BATTERY CALCULATIONS, AND NOTES SCALE: N.T.S. Design Services For The Built Environment ■ Atlanta Birmingham Cincinnati Columbus Dallas Fort Lauderdale Knoxville Jackson Jacksonville Louisville Memphis Nashville Richmond Tampa 0 G R E S H A M S M I T H A N D P A R T N E R S 6030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 954.981.9100 FIRM'S FLORIDA CERT. NO. AAP000034 /CA3806 IB26000797/LC26000381 707 N.B. 3rd AVE., SUrrZ 200 FORT LAUDF.RDMZ, FL 39304 , 954) 527 -1112 CA #00009181 PJT. NOR: iaCHAEL H00 PRGn= #: 120717 •- W M LLJ 4 oo, 0 gr 32 � Fz a n L_ <t Lo r \\ i(3 cr) Lc) I- LL.I O Sam W v 46 0 `• N0 Cr p I T F •wr 100 1 2 •yefl. REVISION No. - Date - Revision .......... ................................................ ................. ... ..�''"�: .�•. N ----------- --------;.. ----- ..........! . - - -.. _`:___ - - - - -- j C t a I • E i FIRE ALARM RISER DIAGRAM AND BATTERY CALCULATIONS FA3nl FILE: PROJECT: 29080.00 DATE: 11/29/2012