Loading...
13-96 (2)-103P11 P10 IJp--Cp S11 S10 S9 2p 0, 2E P9 P8 Dp D-p S8 P7 P8 D'p p S7 Vp P5 P4 P3 P2 P1 S01 S8 S5 S4 S3 S2 S1 2pp 2p 2p 2CO 2p 2E 2E CONTROL MODULE SE7 ZE- SE5 E SE3 a SE1 20-E ELEVATOR SHAFT SE9 SE10 2 E J E SES OE SE8 OE ' SE4 \WE € SE2 OE : A59 A80 A81 A62 A54 AN AN A87 AM 75M 75M 7300 73CD 75CD 750 75M 75CD 73M 7800 11OCD A63 A54 A65 ASO A67 ASS A89 A70 A71 A72 A73 A43 A48 A47 AM A49 75CD 73CD 75CD 75M A50 A51 A52 A53 AM A37 AM A39 A40 75CD 75CD 75CD 75CD A41 A42 A43 A44 M21Si o Al A2 A3 A4 AS AS A7 AS A9 75M 7500 75CD 75M 75M 75M 75M 75CO 75M 75CD 75CD 75CD 75CD A10 All Al2 A13 A14 A15 A18 A17 A18 A19 A20 A21 A22 75M 75CD 75CD 75M 75CD 75CD 75CD 75CD 75CD 75CD 75CO 75CD 75CD A23 A24 AM A28 A27 AM M AM A31 A32 AM AM AM FIRE ALARM SYSTEM WIRE SCHEDULEo MAIN FIRE ALARM RIPS FIRE ALARM SYSTEM SHALL BE POWER LIMITED CONTROL PANEL • INITIATING CIRCUITS: 4 CONDUCTOR, #18 AWG (FRCP) SOLID, SHIELDED TWISTED PAIR 2 • INDICATING CIRCUITS: 2 CONDUCTOR, #14 AWG SOLID, SHIELDED CABLE NOTES: 1. PROVIDE PLENUM RATED FIRE ALARM CABLE WHERE REQUIRED. 3 2. VERIFY IF EXISTING FA SYSTEM CAN INTERFACE WITH THIS NEW BUILDING'S FA SYSTEM. - 3. ALL CONTROLS FOR ALARM SYSTEM SHALL BE AT MAIN PANEL KEY NOTES: FLOW O D AS INDICAT THE FIRESPR NKLER SYSTEMDRAWIN S. ON O CO MM CA R TO MAIN BUILDING GROU TOR TRAN MITTER TO MAIN TELE HONE O BACKBOARD. 2 FIRE ALArm"M SYSTEM NOTES 1. THE MAIN FIRE ALARM CONTROL PANEL SHALL BE A MICROPROCESSOR BASE SYSTEM WITH ADDRESSABLE, INTELLIGENT DETECTORS. ADDRESSABLE CONTROL RELAY AND MONITOR MODULES, VISIBLE AND AUDIBLE SYSTEM ANNUCIATORS AND OTHER SYSTEM CONTROLLED DEVICES AS REQUIRED. 2. PROVIDE REMOTE POWER SUPPLY AS INDICATED FOR EACH FLOOR FOR FUTURE TENANT BUILDOUT. THE FIRE THE FIRE ALARM SHALL BE CAPABLE OF FUTURE EXPANSION AS REQUIRED IN THE TENANT TENANT SPACES. 3. ALL WIRING AND CONDUIT TO CONFORM TO N.F.P.A. 72 AND N.E.C. ARTICLE 760. WIRING SHALL BE SOLID COPPER OR STRANDED COPPER WITH A MAX. OF 7 STRANDS FOR 16 GA AND 18 GA, STRANDED COPPER WITH A MAX. OF 19 STRANDS FOR SIZES 14 AND LARGER AS RQUIRED BY N.E.C. 760 AND N.F.P.A. 70. 4, ALL FIRE STOP PENETRATIONS SHALL BE MADE WITH APPROVED (NEC) METALLIC CONDUIT AND SHALL BE SEALED WITH A U.L APPROVED FIRE STOP MATERIAL (SEE FIRE STOP DETAIL) 5. ROUTING OF THE FIRE ALARM SYSTEM CONDUIT IS DIAGRAMMATIC ONLY, VERIFY EXACT LOCATIONS PRIOR TO STARTING WORK. 6. ALL FIRE ALARM VISUAL SIGNAL (STROBES) SHALL ACTIVATE UPON INITIATION OF THE GENERAL ALARM. 7. ALL FIRE ALARM VISUAL SIGNALS IN OPEN AREA SHALL HAVE A THREE PLUS TEMPORAL PATTERN. 8. ALL FIRE ALARM AUDIBLE SIGNALS SHALL HAVE A SOUND LEVEL OF AT LEAST 15 dba ABOVE THE AVERAGE ABMBIENT SOUND LEVEL. 9. MANUAL STATIONS SHALL BE INSTALLED AT 48' INCHES A.F.F. 10. MOUNT FIRE ALARM SYSTEM HORN /STROBES SUCH THAT THE ENTIRE LENS IS 80" A.F.F. OR 6- BELOW CEILING, WHICH EVER IS LOWER. 11. MOUNT FIRE ALARM SYSTEM STROBES SUCH THAT THE ENTIRE LENS IS 80' A.F.F. CAR 6" BELOW CEILING, WHICH EVER IS LOWER. 12. SMOKE DETECTORS TO BE INSTALLED AS REQUIRED BY N.F.P.A. 72. 13. THE FIRE ALARM PANEL SHALL HAVE AN EARTH GROUND CONNECTION AS REQUIRED BY THE SYSTEM MANUFACTURER, AND N.E.C. ARTICLE 760. MINIMUM WIRE SIZE IS AWG FOR GROUND CONNECTION. (NOTE PANEL NEUTRAL OR CONDUIT GROUND IS NOT ACCEPTABLE 14. A GENERAL ALARM SHALL BE ANNUNCIATED UPON ACTIVATION OF ANY PULL STATION, FLOW SWITCH OR DETECTION DEVICE. 15. A TROUBLE SIGNAL SHALL BE ANNUNCIATED UPON FAILURE OR REMOVAL OF ANY DETECTION OR MANUAL DEVICE. 16. A SUPERVISORY SIGNAL SHALL BE ANNUNCIATED UPON ACTIVATION OF ANY FIRE SPRINKLER SYSTEM TAMPER SWITCH. 17. HVAC DUCT SMOKE DETECTORS SHALL BE CONNECTED TO THE FIRE ALARM CONTROL PANEL AND SHALL INITIATE A SUPERVISORY SIGNAL ONLY. 18. FIRE ALARM SYSTEM SHALL BE U.L CERTIFIED. 19. ALL FIRE ALARM INITIATING DEVICES SHALL BE ADDRESSABLE AND ALL FIRE ALARM CIRCUITS SHALL BE CLASS "B', STYLE W SLC AND CLASS "B" STYLE "Y" NAC CIRCUITS. 20. PROVIDE CERTIFICATE OF COMPLETION AT THE FINAL INSPECTION OF THE FIRE ALARM SYSTEM. 21. PROVIDE THE OWNER WITH A COMPLETE FIRE ALARM SYSTEM AND INSTALLATION MANUAL COVERING MANUAL COVERING ALL SYSTEM EQUIPMENT INSTALLED FOR THIS PROJECT. KEEP AT THE MAIN FIRE ALARM CONTROL PANEL 22. ALL PULL STATIONS TO HAVE UL LISTED COVERS. 23. ALL STROBE LIGHTS SHALL COMPLY WITH NFPA 72 24. MINIMUM RADIO SIGNAL STRENGTH AS REQ'D BY AHJ SHALL BE MAINTAINED PER FFPC NFPA 1 11.3.1.3. RADIO SIGNAL STRENGTH MUST BE THE SAME FOR INSIDE AND OUTSIDE OF THE BUILDING. PROVIDE AN AMPLIFIED SYSTEM TO MEET MINIMUM RADIO STRENGTH AS REQUIRED BY AHJ. DO NOT INSTALL EIRE ALARM PER 7MS Di,F,W.1T TG! FEEQ- E TNiFjTA r T ATTON FireAlarrr: contra CiQt`a 'W:Ci'iF:- pl Ii i S'? ?1I be subin'ted forrRrmit 2uyr�val to hli.mi- Dade County Piro D::parlm. jjt. Approved for Buildh -,,r Permit oriy! Date gy ITEM FRE ALARM BATTERY CALCULATION QTY REQUIRED TOTAL STANDBY CURRENT PER ITEM (AMPS) ALARM CURRENT PER UNIT (AMPS) MINIMUM QTY STANDBY TOTAL ALARM CURRENT (AMPS) �p MANUAL PULL STATION .0 X 11 = .0 .000230 X 11 = .00253 (BP PHOTOELECTRIC SMOKE DETECTOR .000230 X 8 = .00184 .0065 X 8 = .052 0E ELEVATOR PHOTOELECTRIC SMOKE DETECTOR .000230 X 13 = .00299 .0065 X 13 X .0845 Opp DUCT DETECTOR .015 X 2 = .03 .012 X 2 = .024 @"I HEAT DETECTOR .00015 X 3 .00045 .005 X 3 = .015 FACP FIRE ALARM CONTROL PANEL .1 X 1 = .1 .15 X 1 = .15 Q FIRE ALARM SYSTEM POINT ANNUNCIATOR .04 X 1 = .04 .056 X 1 = .056 FAANS ALARM COMMUNICATIONS ANNUNCIATOR .1 X 1 = .1 .17 X 1 = .17 �Q�7e STROBE (75 CANDELA) .0 X 44 s 0 .123 X 44 = 5.412 % %tto STROBE (110 CANDELA) .0 X 1 = 0 .140 X 1 = .140 STANDBY CURRENT (AMPS)_ � 0'3 ALARM CURRENT (AMPS) 6.1 REQUIRED OPERATING TIME OF SECONDARY POWER SOURCE FROM NFPA 72 1- 5.2.5: STANDBY 24 HOURS ALARM: 5 MINUTES X 1/60 = 0.0833 HOURS ITEM I DESCRIPTION ', STANDBY CURRENT PER UNIT (AMPS) QTY REQUIRED TOTAL STANDBY CURRENT PER ITEM (AMPS) ALARM CURRENT PER UNIT (AMPS) MINIMUM QTY STANDBY TOTAL ALARM CURRENT (AMPS) �p MANUAL PULL STATION .0 X 11 = .0 .000230 X 11 = .00253 (BP PHOTOELECTRIC SMOKE DETECTOR .000230 X 8 = .00184 .0065 X 8 = .052 0E ELEVATOR PHOTOELECTRIC SMOKE DETECTOR .000230 X 13 = .00299 .0065 X 13 X .0845 Opp DUCT DETECTOR .015 X 2 = .03 .012 X 2 = .024 @"I HEAT DETECTOR .00015 X 3 .00045 .005 X 3 = .015 FACP FIRE ALARM CONTROL PANEL .1 X 1 = .1 .15 X 1 = .15 Q FIRE ALARM SYSTEM POINT ANNUNCIATOR .04 X 1 = .04 .056 X 1 = .056 FAANS ALARM COMMUNICATIONS ANNUNCIATOR .1 X 1 = .1 .17 X 1 = .17 �Q�7e STROBE (75 CANDELA) .0 X 44 s 0 .123 X 44 = 5.412 % %tto STROBE (110 CANDELA) .0 X 1 = 0 .140 X 1 = .140 STANDBY CURRENT (AMPS)_ � 0'3 ALARM CURRENT (AMPS) 6.1 FIRE ALARM RISER DIAGRAM, BATTERY CALCULATIONS, AND NOTES SCALE: N.T.S. REQUIRED TOTAL SYSTEM REQUIRED REQUIRED DEBATING TOTAL SYSTEM MINIMUM REQUIRED STANDBY ALARM STANDBY AMPERE HOUR STANDBY ALARM ALARM CAPACITY ALARM TIME CURRENT CAPACITY TIME BATTERY CURRENT CAPACITY (HOURS) (AMPS) (AMP - HOURS) (HOURS) 7.2 (AMPS) 0.5081 (AMP - HOURS) 24 X 0.3 7.2 0.0833 X 6.1 0.5081 REQUIRED REQUIRED REQUIRED DEBATING MINIMUM STANDBY ALARM AMPERE HOUR FACTOR O AMP -HOUR CAPACITY CAPACITY BATTERY 1.2 BATTERY (AMP - HOURS) (AMP - HOURS) REQUIRED 7.2 + 0.5081 = 7.7081 X 1.2 9.2497 Design Services For The Built Environment ■ Atlanta Birmingham Cincinnati Columbus Dallas Fort Lauderdale Knoxville Jackson Jacksonville Louisville Memphis Nashville Richmond Tampa ■ G R E S H A M SMITH AND P A R T N E R S 8030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 954,981.9100 FIRM'S FLORIDA CERT. N0, AAP000034/CA3806 I@26000797/LC26000381 DELTA G CONSULTING ENGINEERS. INC. 707 N.B. 3rd AVE., 3UT1'B 200 FORT LAUDF.IiDAI$, PZ.. 33304 964) 627 -1112 CA#00009181 PIT. YaR: 1QCHAIL RA U01 W LL Lo T*- LO F- LJJ IT H00 PROJECT j: 120717 w to Q� Lt..i o G, \G �Nt � a'L N 46 p ST • 48100 ?fill � 19 REVISION a. - e is'o 1 02/01/13 I Addendum #1 FIRE ALARM RISER DIAGRAM AND BATTERY CALCULATIONS FA3ml FILE: PROJECT: 29080.00 DATE: 11/29/2012