13-96 (2)-049SUMP PUMP DETAIL P 1.2 SCALE: N.T.S. OIL SMART SIMPLEX PANEL NM FIELD COORD. FINAL COORDINATE ELECTRICAL. CONNECTION MATH LOCATION ARM ELECTRICAL CONTRACTOR REMOTE ALARM LOCATION ELECTRICAL CONTRACTOR SHALL BE L NTH OWNER. FOLLOW MANUFACTURER RECOMMENDATiONS (REMOTE ALARM CAN BE MOUNTED PROVIDE SEAL TIGHT 2500 FT FROM CONTROL PANEL) CONNECTION (TYPICAL) SLEEVE AND SEAL PIPING 1TiRU WALL OFF -SET PIPING AS NEEDED 1 1/2' DRAIN LINE BELOW SLAB. SEE BOTTOM OF FIELD CONDITIONS FLOOR PLAN FOR CONTINUATION. ELEVATOR SHAFT FULL OPEN VALVE i / CHECK VALVE QUID SMT HIGH HEAVY DUTY TRAFFIC BEARING / ALARM SWITCH LEVEL GRATE 1 1/2' THICK STEEL. % OILSMART PUMP SWITCH ON / AB ABOVE IMPELLER 1.5' 24�� SUMP j Y PUMP DISCHARGE (SHALL BE COORD. WITH ELEVATOR Tremco Incorporated Seal ant/Weatherproofing Division Fire Protection Systems Group 2628 Pearl Rd. Medina, OH 44256 Toll Free: 866- 209 -7055 www.tremcofirestop.com LIBERTY PUMPS MODEL #ELV250 AUTOMATIC SUMERSIBLE SUMP PUMP (30 GPM, 14FT. TDH., 1/3 HP, 3450 RPM, 115 V) PROVIDED WITH OIL SMART SIMPLEX SUMP PUMP SYSTEM MODEL#OSSIM -30 (PUMPS WATER ONLY, WILL NOT PUMP HYDROCARBONS) System No. W -L -1278 March 11, 2004 F Rating - 2 Hr T Rating - 0 Hr 2 TRAP PRIMER DIAGRAM P 1.2 1 SCALE: N.T.S. CHROME PLATED ESCUTCHEON AT WALL 314' X 1 I !�1 /2' SOV TEE LAVATORY ----f CW SUPPLY -J TRAP PRIMER VALVE �'�' s� WITH INTEGRAL. A SAVER —� BACKFLOW PREVENTER AG-500 AIR GAP � AND VACUUM BREAKER aFAHOUT PLuo FITTING PORT. PRECISION FINISHED FLOOR 00 PLUMBING PRODUCTS WALL ALL API -500 (DU -3). DISTRIBUTION UNIT SECURE DISTiBUTION UNIT M BACKING FLOOR ° SHEET BETWEEN STUDS MOUNT IN MAINT. ROOM 1/2' COPPER TUBING TRAP SUPPLIES ROUTE BELOW FLOOR M FLOOR DRAIN TRAPS (SEE PLAN) 48' MIN. AFF rREmco Drawing Not to Scale I 1. Wall Assembly The fire-rated gypsum board /stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A Studs Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC. Steel studs to be min 2 -1/2 in. (64 mm) wide and spaced max 24 in. (610 mm) OC. B. Gypsum Board* Two layers of nom 5/8 in. (16 mm) thick gypsum board, as specified in the individual Wall and Partition Design. Max diam of opening is 9 -7/8 in. (251 mm). 2. Through Penetrants One metallic pipe, conduit or tubing to be installed within the firestop system. An annular space of min 0 in. to max 7/8 in. (22 mm) is required within the firestop system. Pipe, conduit or tubing to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used: A. Steel Pipe Nom 8 in. (203 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe Nom 8 in. (203 mm) diam (or smaller) cast or ductile iron pipe. C. Conduit Nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing (EMT) or nom 6 in.(152 mm) diam (or smaller) rigid steel conduit. D. Copper Tubing Nom 4 in. (102 mm) diam (or smaller) Type L (or heavier) copper tubing. E. Copper Pipe Nom 4 in. (102 mm) diam (or smaller) Regular (or heavier) copper pipe. 3. Firestop System The firestop system shall consist of the following: A Packing Material Min 1/2 in. (13 mm) thickness of min 4 pcf (64 kg /cu meter) mineral wool bait insulation firmly packed into opening as a permanent form. Packing material to be recessed from both surfaces of wall as required to accommodate the required thickness of fill material. B. Fill, Void or Cavity Material* - Sealant Min 1/2 in. (13 mm) thickness of fill material applied within the annulus, flush with both surfaces of wall. TREMCO INC - Fyre SRI, TREMstop Acrylic or TREMstop Intumescent Acrylic *Bearing the UL Classification Mark Reproduced courtesy of Underwriters Laboratories, Inc. See UL Fire Resistance Directory for additional information. (UL /C UL) 1 of 1 Tremco Incorporated Sealant/Weatherproofing Division Fire Protection Systems Group 2628 Pearl Rd. Medina, OH 44256 Toll Free: 866 - 209 -7055 www.tremcofirestop.com System No. W -L -2161 December 08, 2004 F Ratings - 1 and 2 Hr (See Item 1) T Rating - 0 and 3/4 Hr (See Item 1) 3 CONDENSATE ROOF PIPING SUPPORT P1.2 SCHEMATIC DETAIL SCALE: N.T.S. SLOPE PVC PIPE PER FMC -2010. SECTION 307 HEX WOAD / SELF PIERANG SCREW / SUE A 1' LONG, TYP. 20 GA. MIN. GAIN. / STRAP, ANCHM / � SEE PLANS FOR Sim M ROOF SUPPORT / — ATTACK To ROOF 1MTH 'TAM -PRO am* ��90000 Section A -A Drawing Not to Scale 1. Wall Assembly - The 1 and 2 hr fire-rated gypsum board /stud wall assembly shall be constructed of the materials and in the manner described in the individual U300, U400 or V400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs - Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC. Steel studs to be min 2 -1/2 in. (64 mm) wide and spaced max 24 in. (610 mm) OC. B. Gypsum Board* - One or two layers of nom 1/2 or 5/8 in. (13 or 16 mm) thick gypsum board as specified in the individual Wall and Partition Design. Max diam of opening is 4 in. (102 mm). The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. The T Ratings are 0 and 3/4 hr when installed in 1 and 2 hr rated walls, respectively. 2. Through Penetrants - One nonmetallic pipe to be centered within the firestop system. Pipe to be rigidly supported on both sides of wall assembly. A nom annular space of 13/16 in. (21 mm) is required within the firestop systems. The following types and sizes of nonmetallic pipes may be used: A. Polyvinyl Chloride (PVC) Pipe - Nom 2 in. (51 mm) diam (or smaller) Schedule 40 solid or cellular -core PVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping system. B. Acrylonitrile Butadiene Styrene (ABS) Pipe - Nom 2 in. (51 mm) diam (or smaller) Schedule 40 solid or cellular -core ABS pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. 3. Firestop System - The firestop system shall consist of the following: A. Fill, Void or Cavity Material* - (Wrap Strip) - Nom 0.13 in. (3.3 mm) thick by 2 -3/8 in. (60 mm) wide intumescent wrap strip. The wrap strip is continuously wrapped around the outer circumference of the pipe (webbing face out) three times and slid into the annular space 1 -5/8 in. (41 mm) such that 3/4 in. (19 mm) of the wrap strip protrudes from the wall surface. Wrap strips are installed on each side of the wall. TREMCO INC - TREMstop -WS B. Tie Wire - No. 18 gauge, tightly wrapped around wrap strip securing wraps around pipe. C. Aluminum Tape - Nom 1 -1/2 In. (38 mm) wide aluminum tape wrapped around wrap strip, flush with outside edge of wrap strip. D. Packing Material - Foam backer rod firmly packed into the opening as a permanent form. Packing material to be recessed from both surfaces of wall as required to accommodate the required thickness of fill material. E. Fill, Void or Cavity Material* - (Caulk) - Min 1/2 in. (13 mm) thickness of fill material applied within the annulus, flush with both surfaces of wall. Additional fill material to be installed such that a min 1/4 in. (6 mm) crown is formed around the wrap strip /wall interface and at the penetrating item at exposed edge of wrap strip. TREMCO INC - TREMstop Intumescent Acrylic (U L /cUL ) *Bearing the UL Classification Mark Reproduced courtesy of Underwriters Laboratories, inc. See UL Fire Resistance Directoryfor addition.1 information. Page I of I J / WWMLMI20ND.COM PLASTIC ROOF CEMENT OR EQUAL AS MP1 SEALANT (COL'10. APPROVED) —MIR0 INDUSTRIES IM oe PILLOW BLOCK PIPESTAND MODEL NO. 1.5 PIPESTAND ,5• MATERIALS: RIGID POLMARBON E RESIN WITH CARBON BLACK ADDED. FOR UV RESISTANCE AND PROTECTION. 01.5' SPACER, PROVIDE la AS RM FOR PIPE M MAINTAIN SLOPE & CIEARMCE CONTRACTORS SHALL FIELD VERIFY ALL DIMF1O NS ACCOMMODATE HEIGHT OF SUPPORT IN ORDER M COMPLY WiTH AIR GAP REQUNE W AT ROOF DRAIN. CONDENSATE PIPE TERMINATION SHALL BE Y ABOVE EXISTING ROOF DRAIN. PROVIDE SUPPORTS AS PER TABLE 3051.4 OF FALC - MECHANICAL. S1�'j P' oL A`r.YS t e'er Ct' T 1 11 '1 '1 2 Hour Fire Rated Through Penetration Firestop for Single Metal Pipe through Concrete Floors or Walls using FYRE- SHIELD. F- Rating = 2 Hr. D LUMM., 3735 Green Rd. Beachwood, OH, 44122 Drawing not to scale 0 Pre -Rated Concrete Floors or Block Walls = Min. 3" thick concrete floor assembly. Min. 3 -1/2" thick conrete wall assembly. O2 Metallic Pipe: A) Steel Pipe- 8" diam. (or smaller) Sch. 40 (or heavier) steel pipe. B) Iron Pipe- 8" diam. (or smaller) cast or ductile iron pipe. C) Conduit - 4" diam. (or smaller) EMT or steel conduit. D) Copper Tubing - 4" diam. (or smaller) Type L (or heavier) copper tubing. E) Copper Pipe- 4" diam. (or smaller) Regular (or heaveir) copper pipe. The annular space be min. 1/2" to max. 7/8 ". OPacking Material - Min. 2 -1/2" thickness of mineral wool (min. 4.0 pcf) insulation, firmly packed into opening as a permanent form. ® FYRE- SHIELD- Min. 1/2" thickness of sealant applied within annulus, flush with top surface of floor or both surfaces of wall assembly. Project: The products used in the above assembly have been tested in accordance with the following: The above described assembly has been ASTM E814 (UL1479) Standard Test Method tested and is based on both past and antici- LOCatlon: for Through Penetration Firestopping. pated performance criteria. Tremco shall not be liable for any damages, direct or con - Installer: Date: 5/11/98 Drawing: TR -1233 sequential, resulting from use of this material or design. Tremco shall only be responsible Signature: Approved by: M. Starr for replacing material found to be defective. Design Services For The Built Environment Atlanta Birmingham Cincinnati Columbus Dallas Fort Lauderdale Knoxville Jackson Jacksonville Louisville Memphis Nashville Richmond Tampa 0 G R E S H A M SMITH A N D P A R T N E R S 6030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 954.981.9100 FIRM'S FLORIDA CERT. NO. AAP000034 /CA3806 IB26000797/LC26000381 707 N.E. 3rd AVE.. 3UrrE 200 FORT LAUDERDALE, FL. 93304 ®(954) 527 -1112 CA#00009181 PJT. NGR: 11111CHM H00 PROJECT #: 120717 e � � * m UJm Q 0 m �o �`- to (t3 L W 0 `,���lteerle3e,a, 27 0 ; °o m. O rEORGE JUpN,. P.E. Ft.DBLDA� r CF'�13E #46100 DATki *01/13 REVISION No. - Date - Revision A ? 02/01/13 ' Addendum #1 PLUMBING DETAILS P1.2 FILE: PROJECT: 29080.00 DATE: 1 1/2912012