Loading...
13-96 (2)-048I P1.1 PLUMBING GENERAL NOTES 1. ALL WORKMANSHIP AND MATERIAL SHALL BE IN STRICT ACCORDANCE WITH APPLICABLE LOCAL CODES, RULES AND ORDINANCES (FBC- 2010). 2. CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. 3. ALL MATERIAL SHALL BE NEW. 4. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE. 5. ALL EXCAVATION AND BACKFILL AS REQUIRED FOR THIS PHASE OF CONSTRUCTION SHALL BE A PART OF THIS CONTRACT. 6. REQUIRED INSURANCE SHALL BE PROVIDED BY THE CONTRACTOR FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF WORK. 7. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, INSPECTION AND TESTS. B. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT LOCATION OF FIXTURES, PIPING, EQUIPMENT, ETC. 9. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. REPORT ANY DISCREPANCY TO ENGINEER /ARCHITECT PRIOR TO BEGINING CONSTRUCTION. 10. WATER PIPING SHALL BE TYPE "L" COPPER FOR 2" AND UNDER AND TYPE "K" COPPER FOR 2-1/2" AND ABOVE. ALL UNDERGROUND WATER PIPING SHALL BE TYPE "K" COPPER. TYPE "M" IN CONCEALED SPACES IS ACCEPTABLE. 11. SOIL, WASTE AND VENT PIPING SHALL BE CAST IRON NO HUB 301 -72 ABOVE GRADE. BELOW GRADE USE SCHEDULE 40 PVC D.W.V. CONDENSATE DRAIN LINE USE SCHEDULE 40 PVC D.W.V. PVC SHALL NOT BE USED IN ANY MECHANICAL ROOMS OR IN ANY RETURN AIR PLENUMS . USE COPPER PIPE. 12. INSULATE ALL HOT WATER, HOT WATER RETURN, CONDENSATE LINES, EXHAUST LINES ABOVE GRADE AND FIRST 8' -0" OF COLD WATER LINE FROM WATER HEATER /BOILER AS FOLLOWS: HW SUPPLY AND RETURN - 1" THICK PREFORMED FIBERGLASS PIPE INSULATION W/ FACTORY JACKET. CONDENSATE PIPING -�X" ARMAFLEX PREFORMED. EXHAUST PIPE - 3" THICK CALCIUM SILICATE BLOCK INSULATION W/1200 F. STEVENS CLASS CLOTH WRAP. 13. ISOLATE COPPER PIPE FROM HANGER OR SUPPORTS WITH ISOLATOR PAD (HAIR FELT LINING). 14. DIELECTRIC COUPLINGS ARE REQUIRED BETWEEN ALL DISSIMILAR METAL IN PIPING AND EQUIPMENT CONNECTIONS. 15. ALL FIRE RATED FLOOR AND WALL PENETRATIONS SHALL BE PROPERLY PROTECTED FROM FIRE, SMOKE AND WATER PENETRATION BY FILLING VOIDS BETWEEN PIPE AND WALL /FLOOR SLEEVES WITH FIRE RATED FOAM, CHASE TECHNOLOGY CORP.- CTC PR -855 OR 3M, CP -25 CAULKING OR 303 PUTTY, TO ACHIEVE SAME RATING AS WALLS OR FLOORS. 16. PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES. ACCESS PANELS IN RATED WALLS MUST MAINTAIN THE SAME RATING AND MUST MATCH THE FINISH OF THE WALL IN WHICH IT IS INSTALLED. PROVIDE STAINLESS STEEL COMBINATION COVER PLATE AND CLEANOUT PLUG OR ACCESS PANEL FOR ALL WALL CLEANOUTS. 17. FURNISH AND INSTALL APPROVED P.D.I. SHOCK ARRESTORS ON MAIN LINES. REFER TO SCHEDULE IN THIS SHEET. 18. ALL AUTOMATIC ELECTRIC WATER HEATERS SHALL MEET THE STANDARDS OF THE LATEST ENERGY EFFICIENCY CODE. 19. ALL INSTALLATIONS SHALL MEET THE STANDARDS OF THE LOCAL AUTHORITY AND HEALTH DEPARTMENT. 20. OFF SET VENT PIPES 10' -0" AWAY FROM ANY FRESH AIR INTAKE OR DOOR OPENING 21. PROVIDE 1/2" TRAP PRIMER LINE FOR ALL FLOOR DRAINS FROM THE NEAREST PLUMBING FIXTURE OR USE AUTOMATIC TRAP PRIMER AS PPP P1 -500 WITH INTEGRAL BACKFLOW PREVENTER AND VACUUM BREAKER. 2 P1.1 PLUMBING SYMBOL LEGEND MARK SYMBOL DESCRIPTION COLD WATER SANITARY LINE - - - - - VENT LINE ___3N_ -Now- SAFEWASTE LINE - COLD WATER LINE -- HOT WATER LINE - - - HWR HOT WATER RETURN SD STORM DRAIN LINE CD CONDENSATE LINE FM FORCE MAIN LINE -- DN PIPE DOWN -' --a UP PIPE UP ---DQ- GATE VALVE VALVE W/ EL -451 TRANSF., TOILET SEAT MODEL #SC534 FLOOR PENETRATION ABOVE COUNTER LAVATORY (AT TOILET ROOMS) WATER HAMMER ARRESTOR ® RD ROOF DRAIN OD OVERFLOW ROOF DRAIN ® GD GARAGE DRAIN ® AD AREA DRAIN ® CO CLEAN OUT )I" VTR VENT THRU ROOF RWL RAIN WATER LEADER FD FLOOR DRAIN -D4�- HB HOSE BIBB W/ SHUT -OFF VALVE ZURN MODEL FD- 2322 -ST AND VACUUM BREAKER ZURN 1343 OR EQUAL ® WALL HYDRANT W SHUT -OFF MODEL #K- T11838, W/ WAL MOUNT VALVE #K- 11830 -NA VALVE AND VACUUM BREAKER COUNTER TOP SINK (LOUNGE ROOM) ZURN MODEL Z1350 (ENCASED) 1/2" OR EQUAL WL XX RAIN WATER LEADER RISER CW XX COLD WATER RISER NO NORMALLY OPEN NC NORMALLY CLOSED U/G UNDER GROUND NOTES: 1. ALL FIXTURE AND FAUCETS SHALL COMPLY WITH MIAMI WATER CONSERVATION REGULATIONS SECTION 8 -31, TABLE 604.4 2. ALL WALL HUNG PLUMBING FIXTURES SHALL COMPLY WITH F.B.0 -2010 SECTION 2318.1.15 & 2517.5.1.1 3• INSULATE PER A.D.A. ALL EXPOSED HANDICAP LAVATORIES DRAIN PIPING AND HOT & COLD STOP AND SUPPLIES. COVERS SHALL BE SOFT, REMOVABLE AND UPC APPROVED. MANUFACTURE: PLUMBEREX HANDY- SHIELD OR PRO- SERIES. 8 MIXING VALVE DETAIL P1.1 NO SCALE 110 TEMPERED WATER LINE (TEMP NOT TO EXCEED 110') -MIXING VALVE LEONARD MODEL TM -30 OR EQUAL _•w 3 /4"INLET /3/4 "OUTLET 140 COLD WATER SUPPLY LINE HOT WATER SUPPLY LINE 3 P1.1 NN FIXTURE CONNECTION O ECTION SCHEDULE MARK DESCRIPTION WASTE COLD WATER HOT WATER MANUFACTURE AND MODEL ACCESSORIES W WATER CLOSET TANK TYPE (FLOOR MOUNTED) 499 1 / 2" - -- KOHLER "ESCALE" TWO -PIECE TOILET MODEL #K -3588, ELONG. BOWL (1.6 GPM) TOILET SEAT E70004 „ , BOWL K -4308 , TANK K -4472 W -1 ADA WATER CLOSET FLUSH VALVE (FLOOR MOUNTED) 419 SEE ROOF PLAN --- TOTO MODEL CT705ELN(G), ELONGATED SLOAN "ROYAL OPTIMA" MODEL 111- 1.28HWS FLUSHOM. GARAGE DRAIN SEE PLANS - - -- ZURN MODEL Z505 OR EQUAL. THIRD FLOOR PLAN -NEW CONSTRUCTION PLUMBING PLAN. FRONT BOWL (1.28 GPM) VALVE W/ EL -451 TRANSF., TOILET SEAT MODEL #SC534 L -1 ABOVE COUNTER LAVATORY (AT TOILET ROOMS) 1 1/4" 1/2" 1/2" KOHLER "ESCALE" ABOVE COUNTER BATH. SINK KOHLER "PURIST" TOUCHLESS WALL MOUNTED FAUCET TRIM, TRENCH DRAIN SEE PLANS - - -- ABT POLYDRAIN TRENCH DRAIN 10 MODEL #K -19047 (0.5 GPM) MODEL #K- T11837, W/ WAL MOUNT VALVE #K- 11830 -NA SK ADA COUNTER TOP SINK (EXAM ROOM) 1 1 / 2 " 1 / 2 „ 1/2" KOHLER "ESCALE" ABOVE COUNTER KOHLER "MEMIORS" TOUCHLESS WALL MNTD. FAUCET TRIM, ZURN MODEL FD- 2322 -ST 3/4" HW HOT WATER BATH. SINK MODEL #K -19047 (0.5 GPM) MODEL #K- T11838, W/ WAL MOUNT VALVE #K- 11830 -NA SK -1 COUNTER TOP SINK (LOUNGE ROOM) 1 1/2" 1/2" 1/2" KOHLER "UNDERTONE" SINGLE BOWL KOHLER "ELATE" KITCHEN SINK FAUCET LINE HEAT TRAP APPROVED (SEE DETAIL 4 ON S. STEEL SINK MODEL #K- 3335 -NA MODEL #K- 13963 -CP (MAX. 1.8 GPM) J.SK JANITOR SINK 1 1/2" 1/2" 1/2" ADVANCE TABCO MODEL #9 -OP -40 T &S FAUCET MODEL B- 0665 -BSTR D/W DISHWASHER 1 "I.W - -- 1/2" FIXTURE AS SPECIFIED BY ARCH / OWNER 4 " 3 P & T RELIEF LINE EWC ADA ELECTRIC WATER COOLER 1 1/4- 1/2" - -- OASIS MODEL M8CREE 1/2" SUPPLY PIPES, MCGIURE ANGLE STOPS AND WATER HEATER PROVIDE A HARD COPPER RELIEF VALVE, TERMINATE OVER SERVICE SINK ADJUSTABLE P TRAP. DISCHARGE AT EXTERIOR BUILDING DRAIN VALVE HEATER 6 "MIN. A.F.F BY MANUFACT. NOTES: 1. ALL FIXTURE AND FAUCETS SHALL COMPLY WITH MIAMI WATER CONSERVATION REGULATIONS SECTION 8 -31, TABLE 604.4 2. ALL WALL HUNG PLUMBING FIXTURES SHALL COMPLY WITH F.B.0 -2010 SECTION 2318.1.15 & 2517.5.1.1 3• INSULATE PER A.D.A. ALL EXPOSED HANDICAP LAVATORIES DRAIN PIPING AND HOT & COLD STOP AND SUPPLIES. COVERS SHALL BE SOFT, REMOVABLE AND UPC APPROVED. MANUFACTURE: PLUMBEREX HANDY- SHIELD OR PRO- SERIES. 8 MIXING VALVE DETAIL P1.1 NO SCALE 110 TEMPERED WATER LINE (TEMP NOT TO EXCEED 110') -MIXING VALVE LEONARD MODEL TM -30 OR EQUAL _•w 3 /4"INLET /3/4 "OUTLET 140 COLD WATER SUPPLY LINE HOT WATER SUPPLY LINE 3 P1.1 DRAIN SCHEDULE No DESCRIPTION DRAIN CW REMARKS FD FLOOR DRAIN 3" 1/2" ZURN MODEL Z415B OR EQUAL 3to6 (TOILET ROOMS) 1/8 B PROVIDE TRAP PRIMER RD ROOF DRAIN SEE ROOF PLAN - - -- ZURN MODEL Z100 OR EQUAL. GD GARAGE DRAIN SEE PLANS - - -- ZURN MODEL Z505 OR EQUAL. THIRD FLOOR PLAN -NEW CONSTRUCTION PLUMBING PLAN. TRENCH DRAIN SEE PLANS - - -- ABT TRENCH FORMER SYSTEM TD FIRST FLOOR P -2.6 FOURTH FLOOR PLAN -NEW CONSTRUCTION SANITARY PLAN. MODEL TFX -12 OR EQUAL TRENCH DRAIN SEE PLANS - - -- ABT POLYDRAIN TRENCH DRAIN 10 P -3.1 THIRD FLOOR WATTS SERIES PLT -5 (2.1 GALLONS) 11 SYSTEM MODEL 2512F OR EQUAL AD AREA DRAIN 3" - - -- ZURN MODEL FD- 2322 -ST 3/4" HW HOT WATER OR EQUAL APPROVED PD PLANTER DRAIN 3" - - -- ZURN MODEL Z350 OR EQUAL BALL VALVE (TYP.) H�M TERM- LINE HEAT TRAP APPROVED (SEE DETAIL 4 ON SHEET P1.2) 4 P1.1 SLOPE OF HORIZ. DRAINAGE PIPE - - =- SIZE (inches) P.D.I. DESIGNATION MINIMUM SLOPE (inch per foot) FIXTURE UNITS 2 -1/2 or less CONNECTION 1/4 SIOUX CHIEF 652 -A 3to6 3 1/8 B 8 or larger 12 -32 1/16 TABLE 704.1 OF THE FLORIDA PLUMBING CODE 2010 5 P1.1 WATER HAMMER ARRESTOR SCHEDULE - - =- ••'p�'••' P.D.I. DESIGNATION MANUF. & MODEL FIXTURE UNITS 1 CONNECTION A SIOUX CHIEF 652 -A 1 -11 3 1/2" B SIOUX CHIEF 653 -B 12 -32 P -2.2 3/4" C SIOUX CHIEF 654 -C 33 -60 SECOND FLOOR PLAN -NEW CONSTRUCTION PLUMBING PLAN. 1" SIOUX CHIEF SHOCK ARRESTORS APPROVED FOR INSTALLATION WITH NO ACCESS DOOR REQUIRED. CONFORMS TO ANSI /ASSE 1010 STANDARDS. 6 TYPICAL CONDENSATE DRAIN TRAP P1.1 SCALE: N.T.S. PITCH nr% i TOWARD DF CLEAN OUT PERFORATED 18" MIN 2" MIN BE AT LEAST THE NIPPLE ON THE SHOP DRAWING REQUIREMENTS SHOP DRAWINGS, SHALL BE SUBMITTED COMPLETE, TOGETHER AT ONE TIME AND MUST COME THROUGH THE ARCHITECT. ALL SUBMITTALS SHALL BE MADE WITHIN 30 DAYS OF NOTICE TO PROCEED. ALL SUBMITTALS MUST CLEARLY INDICATE EXACTLY WHICH ITEMS ARE BEING PROPOSED FOR USE. IF NOT, THE SUBMITTAL SHALL BE REJECTED. SUBSTITUTIONS SHALL BE LIMITED TO ONE OF THE ALTERNATES LISTED IN THE CONSTRUCTION DOCUMENTS. PRODUCTS CONSIDERED TO BE EQUAL SHALL BE REVIEWED AND ACCEPTED BY THE ENGINEER, ARCHITECT AND OWNER (10) DAYS PRIOR TO BID DATE. THE CONTRACTOR ASSUMES ALL DESIGN RESPONSIBILITY AND ALL FINANCIAL RISKS FOR PROCEEDING PRIOR TO SHOP DRAWINGS PROCESSING, AND ON ANY ITEM OR WORK THAT IS AT VARIANCE TO THE CONSTRUCTION DOCUMENTS. 0. SHOP DRAWINGS AND SUBMITTALS FOR EACH ITEM SHALL BE REVIEWED NO MORE THAN TWICE. A THIRD SUBMITTAL ON AN ITEM MUST BE ACCOMPANIED BY A PURCHASE ORDER FROM THE CONTRACTOR OR IT SHALL BE REJECTED. 6. CIRCUMSTANCES NECESSITATING A REVISION TO THE PERMITTED DOCUMENTS NOT PROCESSED PRIOR TO INSTALLATION MAY NOT BE ACCEPTED. IF ACCEPTED IT MUST BE LEGIBLE, ACCURATE AND ACCOMPANIED BY A PURCHASE ORDER ORDER FROM THE CONTRACTOR. THE REVISION SHALL BE CHARGED TO THE CONTRACTOR AND DELIVERED TO HIM ON A C.O.D. BASIS. 7. SUBSTITUTIONS FROM THE BASE DESIGN OR VARIATIONS TO THE PERMITTED CONTRACT DOCUMENTS, WHETHER RESULTING FROM PROCESSED SHOP DRAWINGS OR NOT, THAT RESULT IN REQUIREMENTS IN LETTERS OF AUTHORIZATION AND /OR PERMIT CONTRACT DOCUMENT CHANGES MANDATED BY THE AUTHORITY HAVING JURISDICTION WILL NOT BE MADE BY THIS OFFICE UNLESS ACCOMPANIED BY A PURCHASE ORDER FROM THE CONTRACTOR, AND RELEASED ON A C.O.D. BASIS. 8. CONTRACTOR SHALL SUBMIT 5 COPIES OF SHOP DRAWINGS. PLUMBING INDEX - - =- ••'p�'••' P1.1 DRAWING PLUMBING INDEX, NOTES, SCHEDULES AND DETAILS =- G -- - -- - - - 1 2 P1.2 PLUMBING DETAILS 3 P -2.1 FIRST FLOOR PLAN -NEW CONSTRUCTION DOMESTIC WATER PLAN. 4 P -2.2 FIRST FLOOR PLAN -NEW CONSTRUCTION SANITARY PLAN. •' 5 P -2.3 SECOND FLOOR PLAN -NEW CONSTRUCTION PLUMBING PLAN. SHUT -OFF VALVE PROVIDE WITH QUARTER TURN 6 P -2.4 THIRD FLOOR PLAN -NEW CONSTRUCTION PLUMBING PLAN. 7 P -2.5 FOURTH FLOOR PLAN -NEW CONSTRUCTION DOMESTIC WATER PLAN. i 8 P -2.6 FOURTH FLOOR PLAN -NEW CONSTRUCTION SANITARY PLAN. --- 9 P -2.7 ROOF LEVEL PLAN- NEW CONSTRUCTION PLUMBING PLAN 10 P -3.1 DOMESTIC WATER PIPING ISOMETRIC WATTS SERIES PLT -5 (2.1 GALLONS) 11 P -3.2 SANITARY PIPING ISOMETRIC 12 P -3.3 STORM & CONDENSATE DRAINAGE ISOMETRIC 3/4" HW HOT WATER WATTS SERIES PLT -5 SHUT -OFF VALVE CIRCULATION SHOP DRAWING REQUIREMENTS SHOP DRAWINGS, SHALL BE SUBMITTED COMPLETE, TOGETHER AT ONE TIME AND MUST COME THROUGH THE ARCHITECT. ALL SUBMITTALS SHALL BE MADE WITHIN 30 DAYS OF NOTICE TO PROCEED. ALL SUBMITTALS MUST CLEARLY INDICATE EXACTLY WHICH ITEMS ARE BEING PROPOSED FOR USE. IF NOT, THE SUBMITTAL SHALL BE REJECTED. SUBSTITUTIONS SHALL BE LIMITED TO ONE OF THE ALTERNATES LISTED IN THE CONSTRUCTION DOCUMENTS. PRODUCTS CONSIDERED TO BE EQUAL SHALL BE REVIEWED AND ACCEPTED BY THE ENGINEER, ARCHITECT AND OWNER (10) DAYS PRIOR TO BID DATE. THE CONTRACTOR ASSUMES ALL DESIGN RESPONSIBILITY AND ALL FINANCIAL RISKS FOR PROCEEDING PRIOR TO SHOP DRAWINGS PROCESSING, AND ON ANY ITEM OR WORK THAT IS AT VARIANCE TO THE CONSTRUCTION DOCUMENTS. 0. SHOP DRAWINGS AND SUBMITTALS FOR EACH ITEM SHALL BE REVIEWED NO MORE THAN TWICE. A THIRD SUBMITTAL ON AN ITEM MUST BE ACCOMPANIED BY A PURCHASE ORDER FROM THE CONTRACTOR OR IT SHALL BE REJECTED. 6. CIRCUMSTANCES NECESSITATING A REVISION TO THE PERMITTED DOCUMENTS NOT PROCESSED PRIOR TO INSTALLATION MAY NOT BE ACCEPTED. IF ACCEPTED IT MUST BE LEGIBLE, ACCURATE AND ACCOMPANIED BY A PURCHASE ORDER ORDER FROM THE CONTRACTOR. THE REVISION SHALL BE CHARGED TO THE CONTRACTOR AND DELIVERED TO HIM ON A C.O.D. BASIS. 7. SUBSTITUTIONS FROM THE BASE DESIGN OR VARIATIONS TO THE PERMITTED CONTRACT DOCUMENTS, WHETHER RESULTING FROM PROCESSED SHOP DRAWINGS OR NOT, THAT RESULT IN REQUIREMENTS IN LETTERS OF AUTHORIZATION AND /OR PERMIT CONTRACT DOCUMENT CHANGES MANDATED BY THE AUTHORITY HAVING JURISDICTION WILL NOT BE MADE BY THIS OFFICE UNLESS ACCOMPANIED BY A PURCHASE ORDER FROM THE CONTRACTOR, AND RELEASED ON A C.O.D. BASIS. 8. CONTRACTOR SHALL SUBMIT 5 COPIES OF SHOP DRAWINGS. W Design Services For The Built Environment III Atlanta Birmingham Cincinnati Columbus Dallas Fort Lauderdale Knoxville Jackson Jacksonville Louisville Memphis Nashville Richmond Tampa G R E S H A M SMITH AND P A R T N E R S 6030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 954.981.9100 FIRM'S FLORIDA CERT. NO. AAP000034/CA3806 IB26000797/LC26000381 707 N.E. 3rd AVE., SUITE 200 FORT LAUDERDALE, FL. 33304 ®(964) 627 -1112 CA #00009181 PJT. YOR: MICHAEL H00 PROJECT #: 120717 ♦ \� ••'p�'••' ENSF' .'L 9 TYPICAL ELECTRICAL WATER HEATER DETAIL P1.1 LU NO SCALE •' COLD WATER SUPPLY VACUUM RELIEF VALVE O.•'lcl SHUT -OFF VALVE PROVIDE WITH QUARTER TURN INLINE CIRCULATING PUMP TO BE "TACO" 3/4 " HW WATTS MODEL 36 -M1 FULL FLOW BALL VALVES AND A MODEL # 11OB, 120V, 3 / 4" CW FINISHED CEILING UNIONS (TYPICAL) 60Hz, 10, 1/12 HP. --- THERMAL EXPANSION TANK WATTS SERIES PLT -5 (2.1 GALLONS) ♦, CHECK VALVE 1 HEAT TRAP* CHECK VALVE THERMAL EXPANSION TANK p 3/4" HW HOT WATER WATTS SERIES PLT -5 SHUT -OFF VALVE CIRCULATION (2.1 GALLONS) BALL VALVE (TYP.) H�M TERM- LINE HEAT TRAP HEAT TRAP (TYP.) * - I UNION WATER SUPPLY P do T RELIEF VALVE SHUT -OFF VALVE TO HEATER. P & T RELIEF 4 " 3 P & T RELIEF LINE WATER HEATER �G DELETE IF PROVIDED VALVE. FULL SIZE ,ELECTRIC 3/4 RELIEF DRAIN LINE WITH THE WATER HEATER PROVIDE A HARD COPPER RELIEF VALVE, TERMINATE OVER SERVICE SINK ELECTRIC WATER DISCHARGE AT EXTERIOR BUILDING DRAIN VALVE HEATER 6 "MIN. A.F.F BY MANUFACT. SET HEATER WITHIN 24" X 24" X 4" DRAIN VALVE DEEP GALVANIZED SHEET METAL DRAIN PAN (24 GAGE MINIMUM) DELETE IF PROVIDED 3/4" PLYWOOD BELOW I WITH THE WATER HEATER WATER HEATER DRAIN I FLOOR WATER HEATER THERMOSTAT PAN AS PLATFORM I SHALL BE SET AT 110'F 2 "x 2 "x 1L8 -" ANGLE IRON SIZE I 1/8 ANGLE I PROVIDE A 3�4 "HARD COPPER RELIEF VALVE, DISCHARGE 2 MIN. ABOVE MOP SINK 2 BRACKETS I ( ) FOR AIR I MOUNT HEATER AS 1 SAFETY PAN DRAIN LINE GAP COMPLY HIGH AS POSSIBLE TERMINATE OVER SERVICE SINK 1 "DRAIN LINE TERMINATED I 1/2" ANCHOR BOLT OR I 2 "MIN. ABOVE MOP SINK FOR AIR GAP COMPLY EXPANSION BOLT (2 PER BRACKET) WATER HEATER SCHEDULE WATER HEATER SCHEDULE I.D. MANUFACTURER MODEL GALS. VOLTAGE KW PHASE EFF REMARKS I.D. MANUFACTURER MODEL GALS. VOLTAGE KW PHASE EFF REMARKS EWH1 LOCHINVAR ETT050KK 50 208 4.5 1 0.92 FIRST FLOOR EWH -2 LOCHINVAR ESM30KK 30 208 4.5 1 0.93 FOURTH FLOOR W Design Services For The Built Environment III Atlanta Birmingham Cincinnati Columbus Dallas Fort Lauderdale Knoxville Jackson Jacksonville Louisville Memphis Nashville Richmond Tampa G R E S H A M SMITH AND P A R T N E R S 6030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 954.981.9100 FIRM'S FLORIDA CERT. NO. AAP000034/CA3806 IB26000797/LC26000381 707 N.E. 3rd AVE., SUITE 200 FORT LAUDERDALE, FL. 33304 ®(964) 627 -1112 CA #00009181 PJT. YOR: MICHAEL H00 PROJECT #: 120717 REVISION PLUMBING INDEX, NOTES, SCHEDULE AND DETAILS. P1.1 29080.00 9 1 1,3 0t,3 n 1 0 ♦ \� ••'p�'••' ENSF' .'L ND c LU •' �.� O.•'lcl REVISION PLUMBING INDEX, NOTES, SCHEDULE AND DETAILS. P1.1 29080.00 9 1 1,3 0t,3 n 1 0