Loading...
13-96 (2)-046I P1.1 PLUMBING GENERAL NOTES I. ALL WORKMANSHIP AND MATERIAL SHALL BE IN STRICT ACCORDANCE WITH APPLICABLE LOCAL CODES, RULES AND ORDINANCES (FBC- 2010). 2. CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. 3. ALL MATERIAL SHALL BE NEW. 4. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE. 5. ALL EXCAVATION AND BACKFILL AS REQUIRED FOR THIS PHASE OF CONSTRUCTION SHALL BE A PART OF THIS CONTRACT. 6. REQUIRED INSURANCE SHALL BE PROVIDED BY THE CONTRACTOR FOR PROTECTION AGAINST PUBLIC UABIUTY AND PROPERTY DAMAGE FOR THE DURATION OF WORK. 7. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, INSPECTION AND TESTS. 8. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT LOCATION OF FIXTURES, PIPING, EQUIPMENT, ETC. 9. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. REPORT ANY DISCREPANCY TO ENGINEER /ARCHITECT PRIOR TO BEGINING CONSTRUCTION. 10. WATER PIPING SHALL BE TYPE "L" COPPER FOR 20 AND UNDER AND TYPE "K" COPPER FOR 2-1/2* AND ABOVE. ALL UNDERGROUND WATER PIPING SHALL BE TYPE "K" COPPER. TYPE "M" IN CONCEALED SPACES IS ACCEPTABLE. 11. SOIL, WASTE AND VENT PIPING SHALL BE CAST IRON NO HUB 301 -72 ABOVE GRADE. BELOW GRADE USE SCHEDULE 40 PVC D.W.V. CONDENSATE DRAIN LINE USE SCHEDULE 40 PVC D.W.V. PVC SHALL NOT BE USED IN ANY MECHANICAL ROOMS OR IN ANY RETURN AIR PLENUMS . USE COPPER PIPE. 12. INSULATE ALL HOT WATER, HOT WATER RETURN, CONDENSATE LINES, EXHAUST LINES ABOVE GRADE AND FIRST 8' -0" OF COLD WATER LINE FROM WATER HEATER /BOILER AS FOLLOWS: HW SUPPLY AND RETURN - 10 THICK PREFORMED FIBERGLASS PIPE INSULATION W/ FACTORY JACKET. CONDENSATE PIPING --'4" ARMAFLEX PREFORMED. EXHAUST PIPE - 3" THICK CALCIUM SILICATE BLOCK INSULATION W/1200 F. STEVENS CLASS CLOTH WRAP. 13. ISOLATE COPPER PIPE FROM HANGER OR SUPPORTS WITH ISOLATOR PAD (HAIR FELT LINING). 14. DIELECTRIC COUPLINGS ARE REQUIRED BETWEEN ALL DISSIMILAR METAL IN PIPING AND EQUIPMENT CONNECTIONS. 15. ALL FIRE RATED FLOOR AND WALL PENETRATIONS SHALL BE PROPERLY PROTECTED FROM FIRE, SMOKE AND WATER PENETRATION BY FILLING VOIDS BETWEEN PIPE AND WALL/FLOOR SLEEVES WITH FIRE RATED FOAM, CHASE TECHNOLOGY CORP.- CTC PR -855 OR 3M, CP -25 CAULKING OR 303 PUTTY, TO ACHIEVE SAME RATING AS WALLS OR FLOORS. 16. PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES. ACCESS PANELS IN RATED WALLS MUST MAINTAIN THE SAME RATING AND MUST MATCH THE FINISH OF THE WALL IN WHICH IT IS INSTALLED. PROVIDE STAINLESS STEEL COMBINATION COVER PLATE AND CLEANOUT PLUG OR ACCESS PANEL FOR ALL WALL CLEANOUTS. 17. FURNISH AND INSTALL APPROVED P.D.I. SHOCK ARRESTORS ON MAIN LINES. REFER TO SCHEDULE IN THIS SHEET. 18. ALL AUTOMATIC ELECTRIC WATER HEATERS SHALL MEET THE STANDARDS OF THE LATEST ENERGY EFFICIENCY CODE. 19. ALL INSTALLATIONS SHALL MEET THE STANDARDS OF THE LOCAL AUTHORITY AND HEALTH DEPARTMENT. 20• OFF SET VENT PIPES 10' -0" AWAY FROM ANY FRESH AIR INTAKE OR DOOR OPENING 21. PROVIDE 1/2" TRAP PRIMER LINE FOR ALL FLOOR DRAINS FROM THE NEAREST PLUMBING FIXTURE OR USE AUTOMATIC TRAP PRIMER AS PPP P1 -500 WITH INTEGRAL BACKFLOW PREVENTER AND VACUUM BREAKER. 2 P1.1 PLUMBING SYMBOL LEGEND MARK SYMBOL DESCRIPTION COLD WATER SANITARY LINE - - - - - VENT LINE -W- -010- SAFEWASTE LINE - COLD WATER LINE -- HOT WATER LINE - - - HWR HOT WATER RETURN SD STORM DRAIN LINE CD CONDENSATE LINE FM FORCE MAIN LINE 9 DN PIPE DOWN -'-'-� UP PIPE UP -D4-- GATE VALVE VALVE W/ EL -451 TRANSF., TOILET SEAT MODEL #SC534 FLOOR PENETRATION Q WATER HAMMER ARRESTOR RD ROOF DRAIN OD OVERFLOW ROOF DRAIN GD GARAGE DRAIN ® AD AREA DRAIN ® CO CLEAN OUT AIL' VTR VENT THRU ROOF RWL RAIN WATER LEADER DO FD FLOOR DRAIN �,1_ -><F HB HOSE BIBB W/ SHUT -OFF VALVE ZURN MODEL FD- 2322 -ST AND VACUUM BREAKER ZURN 1343 OR EQUAL P do T RELIEF VALVE WALL AND VACUUMSBREEAKEERR MODEL �K -T�11 8R38, W/ W�OUNT VALVE.#K-11830-NA LVE (LOUNGE TOOMj INK ZURN MODEL Z1350 (ENCASED) 1/2- OR EQUAL WL XX RAIN WATER LEADER RISER CW XX COL) WATER RISER NO NORMALLY OPEN NC NORMALLY CLOSED U/G UNDER GROUND NOTES: 1. ALL FIXTURE AND FAUCETS SHALL COMPLY WITH MIAMI WATER CONSERVATION REGULATIONS SECTION 8 -31, TABLE 604.4 2. ALL WALL HUNG PLUMBING FIXTURES SHALL COMPLY WITH F.B.0 -2010 SECTION 2318.1.15 do 2517.5.1.1 3• INSULATE PER A.D.A. ALL EXPOSED HANDICAP LAVATORIES DRAIN PIPING AND HOT do COLD STOP AND SUPPLIES. COVERS SHALL BE SOFT, REMOVABLE AND UPC APPROVED. MANUFACTURE: PLUMBEREX HANDY- SHIELD OR PRO- SERIES. 8 MIXING VALVE DETAIL P1.1 NO SCALE I TEMPERED WATER LINE I (TEMP NOT TO EXCEED 1101 MIXING VALVE LEONARD MODEL 71M-30 OR EQUAL 3 /41NLET/3 /rOUTLET COLD WATER SUPPLY LINE HOT WATER SUPPLY LINE 3 P1.1 FIXTURE CONNECTION ECTION SCHEDULE MARK DESCRIPTION WASTE COLD WATER HOT WATER MANUFACTURE AND MODEL ACCESSORIES W WATER CLOSET TANK TYPE (FLOOR MOUNTED) 4" 1/2" - -- KOHLER "ESCALE" TWO -PIECE TOILET MODEL #K -3588, ELONG. BOWL (1.6 GPM) TOILET SEAT "E70004`, BOWL "K- 4308", TANK "K -4472" W -1 ADA WATER CLOSET FLUSH VALVE (FLOOR MOUNTED) 4" in - -- TOTO MODEL CT705EL.N(G), ELONGATED SLOAN "ROYAL OPTIMA" MODEL 111- 1.28HWS FLUSHOM. GARAGE DRAIN SEE PLANS - - -- ZURN MODEL Z505 OR EQUAL P2.3 SECOND FLOOR PLAN NEW CONSTRUCTION PLUMBING PLAN. FRONT BOWL (1.28 GPM) VALVE W/ EL -451 TRANSF., TOILET SEAT MODEL #SC534 L -1 ABOVE T TOILET' ROOMS) LAVATORY 1 1/4- 1/2- 1 /2" CALE�A� ABOVE COUNTER � TRENCH DRAIN SEE PLANS - - -- ABT POLYDRAIN TRENCH DRAIN 8 BATH. SINK 9047 GPM) MODELLLR�K TRI 8 7,OW/ MOUNT VALVE #K-11830-NA 11830 -NA SK �p� RODM TOP SINK 1 1/2- 1/2» 1/2» �TM�IN"K �K1 - - -- ZURN MODEL FD- 2322 -ST P3.1 DOMESTIC WATER PIPING ISOMETRIC WATER SUPPLY P do T RELIEF VALVE M�OLDEEI. 047 (�0.5 GPM) MODEL �K -T�11 8R38, W/ W�OUNT VALVE.#K-11830-NA SK -1 (LOUNGE TOOMj INK 1 1/2- 1/2- 1 /2" *UNDERTONEO SINGLE KITCHEN VALVE. (ONLY POTTED PLANTS TO BE 3/4" RELIEF DRAIN LINE X00 WITH THE WATER HEATER S. STEEL MODEL #K 335 -NA MODEL #K-L 113963 P (MAX. 1.8 GPM) J.SK JANITOR SINK 1 1/2" 1/2" 1/2" ADVANCE TABCO MODEL #9 -OP -40 T&S FAUCET MODEL B- 0665 -BSTR D/W DISHWASHER 1"I.W - -- 1/2" FIXTURE AS SPECIFIED BY ARCH / OWNER DRAIN VALVE EWC ADA ELECTRIC WATER COOLER 1 1/4" 1/2` - -- OASIS MODEL MSCREE 1/2" SUPPLY PIPES, MCGIURE ANGLE STOPS AND "P Ld WITH H TTHE WATER ADJUSTABLE TRAP. FLOOR WATER HEATER THERMOSTAT PAN AS PLATFORM I SHALL BE SET AT 110'F NOTES: 1. ALL FIXTURE AND FAUCETS SHALL COMPLY WITH MIAMI WATER CONSERVATION REGULATIONS SECTION 8 -31, TABLE 604.4 2. ALL WALL HUNG PLUMBING FIXTURES SHALL COMPLY WITH F.B.0 -2010 SECTION 2318.1.15 do 2517.5.1.1 3• INSULATE PER A.D.A. ALL EXPOSED HANDICAP LAVATORIES DRAIN PIPING AND HOT do COLD STOP AND SUPPLIES. COVERS SHALL BE SOFT, REMOVABLE AND UPC APPROVED. MANUFACTURE: PLUMBEREX HANDY- SHIELD OR PRO- SERIES. 8 MIXING VALVE DETAIL P1.1 NO SCALE I TEMPERED WATER LINE I (TEMP NOT TO EXCEED 1101 MIXING VALVE LEONARD MODEL 71M-30 OR EQUAL 3 /41NLET/3 /rOUTLET COLD WATER SUPPLY LINE HOT WATER SUPPLY LINE 3 P1.1 DRAIN SCHEDULE No DESCRIPTION DRAIN CW REMARKS FE) FLOOR DRAIN 3 1/2 - ZURN MODEL Z415B OR EQUAL 3to6 (TOILET ROOMS) 1/8 B PROVIDE TRAP PRIMER RD ROOF DRAIN SEE ROOF PLAN - - -- ZURN MODEL Z100 OR EQUAL GD GARAGE DRAIN SEE PLANS - - -- ZURN MODEL Z505 OR EQUAL P2.3 SECOND FLOOR PLAN NEW CONSTRUCTION PLUMBING PLAN. TRENCH DRAIN SEE PLANS - - -- ABT TRENCH FORMER SYSTEM TD FIRST FLOOR �_ CHECK VALVE TMED�- EXPANSION TANK p MODEL TFX -12 OR EQUAL TRENCH DRAIN SEE PLANS - - -- ABT POLYDRAIN TRENCH DRAIN 8 P2.6 FOURTH FLOOR PLAN NEW CONSTRUCTION SANITARY PLAN. THIRD FLOOR BALL VALVE (TYP.) HOT WATER TO sYSTEM. SYSTEM MODEL 2512F OR EQUAL AD AREA DRAIN 3" - - -- ZURN MODEL FD- 2322 -ST P3.1 DOMESTIC WATER PIPING ISOMETRIC WATER SUPPLY P do T RELIEF VALVE OR EQUAL APPROVED PD PLANTER DRAIN 3" -- ZURN MODEL Z415B OR EQUAL P3.3 STORM DRAINAGE PIPING ISOMETRIC ELECTRIC WATER HEATER DELETE IF PROVIDED VALVE. (ONLY POTTED PLANTS TO BE 3/4" RELIEF DRAIN LINE X00 WITH THE WATER HEATER 1 USED AT PLANTER.) 4 P1.1 SLOPE OF HORIZ. DRAINAGE PIPE 0 SIZE (inches) P.D.I. DESIGNATION MINIMUM SLOPE (inch per foot) FIXTURE UNITS 2-1/2 or less CONNECTION 1/4 SIOUX CHIEF 652 -A 3to6 FLOW BALL VALVES AND 1/8 B 8 or larger 12 -32 1/16 TABLE 704.1 OF THE FLORIDA PLUMBING CODE 2010 5 1 P1.1 WATER HAMMER ARRESTOR SCHEDULE 0 1 P.D.I. DESIGNATION MANUF. do MODEL FIXTURE UNITS VACUUM RELIEF VALVE CONNECTION A SIOUX CHIEF 652 -A 1 -11 FLOW BALL VALVES AND 1/2" B SIOUX CHIEF 653-B 12 -32 3/4" C SIOUX CHIEF 654-C 33 -60 1" SIOUX CHIEF SHOCK ARRESTORS APPROVED FOR INSTALLATION WITH NO ACCESS DOOR REQUIRED. CONFORMS TO ANSI /ASSE 1010 STANDARDS. 6 TYPICAL CONDENSATE DRAIN TRAP P1.1 SCALE: N.T.S. PITCH TOWAR CLEAN 18" Mil 2" MIN DRAIN PAN SHALL BE AT LEAST THE AS THE NIPPLE ON THE PLUMBING INDEX TYPICAL ELECTRICAL WATER HEATER DETAIL DRAWING 0 1 NO SCALE 1 131.1 PLUMBING INDEX, NOTES, SCHEDULES AND DETAILS VACUUM RELIEF VALVE SHUT -OFF VALVE PROVIDE WITH QUARTER TURN INUNE CIRCULATING PUMP TO BE "TACO` 2 P1.2 PLUMBING DETAILS FLOW BALL VALVES AND A MODEL 1108, 120V, 0Hz, 10, 1/12 HP. 3 4 / » 3 P2.1 FIRST FLOOR PLAN NEW CONSTRUCTION DOMESTIC WATER 4 P2.2 FIRST FLOOR PLAN NEW CONSTRUCTION SANITARY PLAN. WATTS SERIES PLT -5 5 P2.3 SECOND FLOOR PLAN NEW CONSTRUCTION PLUMBING PLAN. (2.1 GALLONS) 6 P2.4 THIRD FLOOR PLAN NEW CONSTRUCTION PLUMBING PLAN. HEAT TRAP* �_ CHECK VALVE TMED�- EXPANSION TANK p 7 P2.5 FOURTH FLOOR PLAN NEW CONSTRUCTION DOMESTIC WATER HOT WATER WATTS SERIES PLT -5 8 P2.6 FOURTH FLOOR PLAN NEW CONSTRUCTION SANITARY PLAN. (2.1 GALLONS) BALL VALVE (TYP.) HOT WATER TO sYSTEM. 9 P2.7 ROOF LEVEL PLAN NEW CONSTRUCTION PLUMBING PLAN _-.- 73M/40 10 P3.1 DOMESTIC WATER PIPING ISOMETRIC WATER SUPPLY P do T RELIEF VALVE 11 P3.2 SANITARY PIPING ISOMETRIC TO HEATER. 12 P3.3 STORM DRAINAGE PIPING ISOMETRIC ELECTRIC WATER HEATER DELETE IF PROVIDED VALVE. LL SIZE 3/4" RELIEF DRAIN LINE X00 WITH THE WATER HEATER PROVIDE A HARD COPPER RELIEF VALVE, TERMINATE OVER SERVICE SINK ELECTRIC WATER DISCHARGE AT EXTERIOR BUILDING SHOP DRAWING REQUIREMENTS 1. SHOP DRAWINGS, SHALL BE SUBMITTED COMPLETE, TOGETHER AT ONE TIME AND MUST COME THROUGH THE ARCHITECT. ALL SUBMITTALS SHALL BE MADE WITHIN 30 DAYS OF NOTICE TO PROCEED. 2. ALL SUBMITTALS MUST CLEARLY INDICATE EXACTLY WHICH ITEMS ARE BEING PROPOSED FOR USE. IF NOT, THE SUBMITTAL SHALL BE REJECTED. 3. SUBSTITUTIONS SHALL BE LIMITED TO ONE OF THE ALTERNATES LISTED IN THE CONSTRUCTION DOCUMENTS. PRODUCTS CONSIDERED TO BE EQUAL SHALL BE REVIEWED AND ACCEPTED BY THE ENGINEER, ARCHITECT AND OWNER (10) DAYS PRIOR TO BID DATE. 4. THE CONTRACTOR ASSUMES ALL DESIGN RESPONSIBILITY AND ALL FINANCIAL RISKS FOR PROCEEDING PRIOR TO SHOP DRAWINGS PROCESSING, AND ON ANY ITEM OR WORK THAT IS AT VARIANCE TO THE CONSTRUCTION DOCUMENTS. 5• SHOP DRAWINGS AND SUBMITTALS FOR EACH ITEM SHALL BE REVIEWED NO MORE THAN TWICE. A THIRD SUBMITTAL ON AN ITEM MUST BE ACCOMPANIED BY A PURCHASE ORDER FROM THE CONTRACTOR OR IT SHALL BE REJECTED. 6. CIRCUMSTANCES NECESSITATING A REVISION TO THE PERMITTED DOCUMENTS NOT PROCESSED PRIOR TO INSTALLATION MAY NOT BE ACCEPTED. IF ACCEPTED IT MUST BE LEGIBLE, ACCURATE AND ACCOMPANIED BY A PURCHASE ORDER ORDER FROM THE CONTRACTOR. THE REVISION SHALL BE CHARGED TO THE CONTRACTOR AND DELIVERED TO HIM ON A C.O.D. BASIS. 7. SUBSTITUTIONS FROM THE BASE DESIGN OR VARIATIONS TO THE PERMITTED CONTRACT DOCUMENTS, WHETHER RESULTING FROM PROCESSED SHOP DRAWINGS OR NOT, THAT RESULT IN REQUIREMENTS IN LETTERS OF AUTHORIZATION AND /OR PERMIT CONTRACT DOCUMENT CHANGES MANDATED BY THE AUTHORITY HAVING JURISDICTION WILL NOT BE MADE BY THIS OFFICE UNLESS ACCOMPANIED BY A PURCHASE ORDER FROM THE CONTRACTOR, AND RELEASED ON A C.O.D. BASIS. 8. CONTRACTOR SHALL SUBMIT 5 COPIES OF SHOP DRAWINGS. 9 TYPICAL ELECTRICAL WATER HEATER DETAIL No. - P1.1 1 NO SCALE 2 ............. COLD WATER SUPPLY VACUUM RELIEF VALVE SHUT -OFF VALVE PROVIDE WITH QUARTER TURN INUNE CIRCULATING PUMP TO BE "TACO` 314" HW WATTS MODEL 36-M1 FLOW BALL VALVES AND A MODEL 1108, 120V, 0Hz, 10, 1/12 HP. 3 4 / » FINISHED CEILING UNIONS (TYPICAL) THERMAL EXPANSION TANK WATTS SERIES PLT -5 CHECK VALVE (2.1 GALLONS) 1 HEAT TRAP* �_ CHECK VALVE TMED�- EXPANSION TANK p 3/4" HW HOT WATER WATTS SERIES PLT -5 -OFF VALVE RECIRCULATION (2.1 GALLONS) BALL VALVE (TYP.) HOT WATER TO sYSTEM. LINE HEAT TRAP* HEAT TRAP (TYP.)* I - _-.- 73M/40 UNION WATER SUPPLY P do T RELIEF VALVE SHUT -OFF VALVE TO HEATER. P de T RELIEF P do T RELIEF LINE ELECTRIC WATER HEATER DELETE IF PROVIDED VALVE. LL SIZE 3/4" RELIEF DRAIN LINE X00 WITH THE WATER HEATER PROVIDE A HARD COPPER RELIEF VALVE, TERMINATE OVER SERVICE SINK ELECTRIC WATER DISCHARGE AT EXTERIOR BUILDING DRAIN VALVE HEATER 6"MIN. A.F.F BY MAN UFACT. SET HEATER WITHIN 24" X 24` X 4" DRAIN VALVE DEEP GALVANIZED SHEET METAL DRAIN I PAN (24 GAGE MINIMUM) Ld WITH H TTHE WATER WATER HEATER DRAIN t FLOOR WATER HEATER THERMOSTAT PAN AS PLATFORM I SHALL BE SET AT 110'F I 2 "x 2 X 1 8" ANGLE IRON SIZE I PROVIDE A 3,/4-WD COPPER RELIEF VALVE, I ) I 27M DISCHARGE 2 IN. ABOVE MOP SINK IN. HEA 1" SAFETY PAN DRAIN LINE I FOR AIR GAP COMPLY 53" A.F.F. TERMINATE OVER SERVICE SINK 1 BRAIN LINE TERMINATED I 2 1/2- ANCHOR BOLT OR I 2"MIN. ABOVE MOP SINK FOR AIR GAP COMPLY EXPANSION BOLT (2 PER BRACKET) WATER HEATER SCHEDULE WATER HEATER SCHEDULE I.D. MANUFACTURER MODEL GALS. VOLTAGE KW PHASE EFF REMARKS I.D. MANUFACTURER MODEL GALS. VOLTAGE KW PHASE EFF REMARKS EIMi -1 LOgiMVAR ETTO5010K 50 208 4.5 1 0.92 FIRST FLOOR ENH -2 LACHINVAR EST03OKK 30 208 4.5 1 0.93 FOURTH FLOOR r Design Services For The Built Environment 0 Atlanta Birmingham Cincinnati Columbus Dallas Fort Lauderdale Knoxville Jackson Jacksonville Louisville Memphis Nashville Richmond Tampa 7 G R E S H A M SMITH AND P A R T N E R S 6030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 954.981.9100 FIRM'S FLORIDA CERT, NO. AAP000034 /CA3806 IB26000797/LC26000381 707 N.E. 3rd AVE., SUITE 200 FORT IAUDERDAIE, FL. 33304 L((954) 527 -1112 CA#00009181 PJT. YGR: 1QCHAEL H00 PROJECT #: 120717 �t�titaz :irs;�f '� = • N 10 0 ST OF v ...0N I PLUMBING INDEX, NOTES, SCHEDULE AND DETAILS. P1.1 FILE: PROJECT: 29080.00 DATE: 11/29/2012 REVISION No. - Date - Revision 1 02/01/13 Addendum #1 2 ............. 03/15/13 City Comments ............................ .............. ................ ........... ------------ - - - - -- ------- - - - - - ------- - - - - -- . -- ........---- - - - - -- ............ PLUMBING INDEX, NOTES, SCHEDULE AND DETAILS. P1.1 FILE: PROJECT: 29080.00 DATE: 11/29/2012