13-96 (2)-045P� 1 I PLUMBING GENERAL NOTES 1. ALL WORKMANSHIP AND MATERIAL SHALL BE IN STRICT ACCORDANCE WITH APPLICABLE LOCAL CODES, RULES AND ORDINANCES (FBC- 2010). 2 CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. 3. ALL MATERIAL SHALL BE NEW. 4. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE. 5. ALL EXCAVATION AND BACKFILL AS REQUIRED FOR THIS PHASE OF CONSTRUCTION SHALL BE A PART OF THIS CONTRACT. 6. REQUIRED INSURANCE SHALL BE PROVIDED BY THE CONTRACTOR FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF WORK. 7. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, INSPEC11ON AND TESTS. 8. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT LOCA11ON OF FIXTURES, PIPING, EQUIPMENT, ETC. 9. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. REPORT ANY DISCREPANCY TO ENGINEER /ARCHITECT PRIOR TO BEGINING CONSTRUCTION. 10. WATER PIPING SHALL BE TYPE "L" COPPER FOR 2" AND UNDER AND TYPE "K" COPPER FOR 2 -1/2" AND ABOVE. ALL UNDERGROUND WATER PIPING SHALL BE TYPE "K" COPPER. TYPE "M" IN CONCEALED SPACES IS ACCEPTABLE. 11. SOIL, WASTE AND VENT PIPING SHALL BE CAST IRON NO HUB 301 -72 ABOVE GRADE. BELOW GRADE USE SCHEDULE 40 PVC D.W.V. CONDENSATE DRAIN LINE USE SCHEDULE 40 PVC D.W.V. PVC SHALL NOT BE USED IN ANY MECHANICAL ROOMS OR IN ANY RETURN AIR PLENUMS USE COPPER PIPE. 12. INSULATE ALL HOT WATER, HOT WATER RETURN, CONDENSATE LINES, EXHAUST LINES ABOVE GRADE AND FIRST 8' -0" OF COLD WATER LINE FROM WATER HEATER /BOILER AS FOLLOWS: HW SUPPLY AND RETURN - 1" THICK PREFORMED FIBERGLASS PIPE INSULATION W/ FACTORY JACKET. CONDENSATE PIPING -Y4" ARMAFLEX PREFORMED. EXHAUST PIPE - 3" THICK CALCIUM SILICATE BLOCK INSULATION W/1200 F. STEVENS CLASS CLOTH WRAP. 13. ISOLATE COPPER PIPE FROM HANGER OR SUPPORTS WITH ISOLATOR PAD (HAIR FELT LINING). 14. DIELECTRIC COUPLINGS ARE REQUIRED BETWEEN ALL DISSIMILAR METAL IN PIPING AND EQUIPMENT CONNECTIONS. 15. ALL FIRE RATED FLOOR AND WALL PENETRATIONS SHALL BE PROPERLY PROTECTED FROM FIRE, SMOKE AND WATER PENETRATION BY FILLING VOIDS BETWEEN PIPE AND WALL /FLOOR SLEEVES WITH FIRE RATED FOAM, CHASE TECHNOLOGY CORP.- CTC PR -855 OR 3M, CP -25 CAULKING OR 303 PUTTY, TO ACHIEVE SAME RATING AS WALLS OR FLOORS. 16. PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES. ACCESS PANELS IN RATED WALLS MUST MAINTAIN THE SAME RATING AND MUST MATCH THE FINISH OF THE WALL IN WHICH IT IS INSTALLED. PROVIDE STAINLESS STEEL COMBINATION COVER PLATE AND CLEANOUT PLUG OR ACCESS PANEL FOR ALL WALL CLEANOUTS. 17. FURNISH AND INSTALL APPROVED P.D.I. SHOCK ARRESTORS ON MAIN LINES. REFER TO SCHEDULE IN THIS SHEET. 18. ALL AUTOMATIC ELECTRIC WATER HEATERS SHALL MEET THE STANDARDS OF THE LATEST ENERGY EFFICIENCY CODE. 19. ALL INSTALLATIONS SHALL MEET THE STANDARDS OF THE LOCAL AUTHORITY AND HEALTH DEPARTMENT. 20• OFF SET VENT PIPES 10' -0" AWAY FROM ANY FRESH AIR INTAKE OR DOOR OPENING 21. PROVIDE 1/2" TRAP PRIMER LINE FOR ALL FLOOR DRAINS FROM THE NEAREST PLUMBING FIXTURE OR USE AUTOMATIC TRAP PRIMER AS PPP P1 -500 WITH INTEGRAL BACKFLOW PREVENTER AND VACUUM BREAKER. P1.1 PLUMBING SYMBOL LEGEND MARK SYMBOL DESCRIPTION COLD WATER SANITARY LINE - - - - - VENT LINE -� SAFEWASTE LINE - COLD WATER LINE -- HOT WATER LINE - - - HWR HOT WATER RETURN SD STORM DRAIN LINE CD CONDENSATE LINE FM FORCE MAIN LINE - DN PIPE DOWN -� UP PIPE UP -DQ- GATE VALVE VALVE W/ EL -451 TRANSF., TOILET SEAT MODEL #SC534 FLOOR PENETRATION ABOVE COUNTER LAVATORY WATER HAMMER ARRESTOR ® RD ROOF DRAIN OD OVERFLOW ROOF DRAIN ® GD GARAGE DRAIN in AD AREA DRAIN ® CO CLEAN OUT jjL, VTR VENT THRU ROOF RWL RAIN WATER LEADER FD FLOOR DRAIN -04�- HB HOSE BIBB W/ SHUT -OFF VALVE ZURN MODEL FD- 2322 -ST AND VACUUM BREAKER BALL VALVE (TYP.) ZURN 1343 OR EQUAL ® WALL HYDRANT W SHUT -OFF W/ WALLM MOUNT VALVE #K-11830-NA VALVE AND VACUUM BREAKER COUNTER TOP SINK ZURN MODEL Z1350 (ENCASED) 1/2" OR EQUAL L w- RAIN WATER LEADER RISER CW XX COLD WATER RISER NO NORMALLY OPEN NC NORMALLY CLOSED U/G UNDER GROUND Pl.l FIXTURE CONNECTION SCHEDULE MARK DESCRIPTION WASTE COLD WATER HOT WATER MANUFACTURE AND MODEL ACCESSORIES W WATER CLOSET TANK TYPE (FLOOR MOUNTED) 4" 1/2" - -- KOHLER " ESCALE" TWO -PIECE TOILET MODEL #K -3588, ELONG. BOWL (1.6 GPM) TOILET SEAT "E70004 ", BOWL "K- 4308 ", TANK "K -4472" W -1 ADA WATER CLOSET FLUSH VALVE 4 » 1 - -- TOTO MODEL CT705ELN(G), ELONGATED SLOAN "ROYAL OPTIMA" MODEL 111- 1.28HWS FLUSHOM. GARAGE DRAIN (FLOOR MOUNTED) - - -- ZURN MODEL Z505 OR EQUAL P2.3 SECOND FLOOR PLAN NEW CONSTRUCTION PLUMBING PLAN. FRONT BOWL (1.28 GPM) VALVE W/ EL -451 TRANSF., TOILET SEAT MODEL #SC534 L -1 ABOVE COUNTER LAVATORY 1 1/4" 1/2" 1/2" KOHLER "ESCALE" ABOVE COUNTER KOHLER "PURIST" TOUCHLESS WALL MOUNTED FAUCET TRIM, TRENCH DRAIN (AT TOILET ROOMS) - - -- ABT POLYDRAIN TRENCH DRAIN 8 BATH. SINK MODEL #K -19047 (0.5 GPM) MODEL #K- T11837, W/ WAL MOUNT VALVE #K- 1130 -NA SK TOP SINK 1 1/2" 1/2" 1/2" COUNTER ODEL "MEMIORSO I ZURN MODEL FD- 2322 -ST (EXAM ROOM) BALL VALVE (TYP.) HOT LINE BATH. SINKS #K-19047 GPM) W/ WALLM MOUNT VALVE #K-11830-NA SK -1 COUNTER TOP SINK 1 1/2" 1/2" 1/2" KOHLER "UNDERTONE" SINGLE BOWL KOHLER "ELATE" KITCHEN SINK FAUCET UNION (LOUNGE ROOM) WATER SUPPLY P do T RELIEF VALVE S. STEEL SINK MODEL #K- 3335 -NA MODEL #K- 13963 -CP (MAX. 1.8 GPM) J.SK JANITOR SINK 1 1/2" 1/2" 1/2" ADVANCE TABCO MODEL #9 -OP -40 T &S FAUCET MODEL B- 0665 -BSTR D/W DISHWASHER 1 "I.W - -- 1/2" FIXTURE AS SPECIFIED BY ARCH / OWNER EWC ADA ELECTRIC WATER COOLER 1 1/4" 1/2" - -- OASIS MODEL M8CREE 1/2" SUPPLY PIPES, MCGIURE ANGLE STOPS AND ADJUSTABLE PROVIDE A HARD COPPER RELIEF VALVE, SET HEATER WITHIN 24" X 24" X 4" DRAIN VALVE P TRAP. DEEP GALVANIZED SHEET METAL DRAIN 1 6 0MIN. A.F.F PAN (24 GAGE MINIMUM) - NOTES: 1. ALL FIXTURE AND FAUCETS SHALL COMPLY WITH MIAMI WATER CONSERVATION REGULATIONS SECTION 8 -31, TABLE 604.4 2. ALL WALL HUNG PLUMBING FIXTURES SHALL COMPLY WITH F.B.0 -2010 SECTION 2318.1.15 & 2517.5.1.1 3. INSULATE PER A.D.A. ALL EXPOSED HANDICAP LAVATORIES DRAIN PIPING AND HOT & COLD STOP AND SUPPLIES. COVERS SHALL BE SOFT, REMOVABLE AND UPC APPROVED. MANUFACTURE: PLUMBEREX HANDY- SHIELD OR PRO- SERIES. 8 MIXING VALVE DETAIL NO SCALE � IIO TEMPERED WATER LINE I (TEMP NOT TO EXCEED 110') dm 4- MIXING VALVE LEONARD MODEL TM -30 OR EQUAL 3/41NLET/3/4 "OUTLET 140 COLD WATER SUPPLY UNE HOT WATER SUPPLY LINE 3 P1.1 DRAIN SCHEDULE No DESCRIPTION DRAIN CW REMARKS FD FLOOR DRAIN 3" 1/2" ZURN MODEL Z415B OR EQUAL 3to6 (TOILET ROOMS) 1/8 B PROVIDE TRAP PRIMER RD ROOF DRAIN SEE ROOF PLAN - - -- ZURN MODEL Z100 OR EQUAL GD GARAGE DRAIN SEE PLANS - - -- ZURN MODEL Z505 OR EQUAL P2.3 SECOND FLOOR PLAN NEW CONSTRUCTION PLUMBING PLAN. TRENCH DRAIN SEE PLANS - - -- ABT TRENCH FORMER SYSTEM TD FIRST FLOOR (2.1 GALLONS) MODEL TFX -12 OR EQUAL TRENCH DRAIN SEE PLANS - - -- ABT POLYDRAIN TRENCH DRAIN 8 P2.6 FOURTH FLOOR PLAN NEW CONSTRUCTION SANITARY PLAN. THIRD FLOOR THERMAL EXPANSION TANK 0 SYSTEM MODEL 2512F OR EQUAL AD AREA DRAIN 3" - - -- ZURN MODEL FD- 2322 -ST P3.1 DOMESTIC WATER PIPING ISOMETRIC BALL VALVE (TYP.) HOT LINE OR EQUAL APPROVED PD PLANTER DRAIN 3" -- ZURN MODEL Z415B OR EQUAL P3.3 STORM DRAINAGE PIPING ISOMETRIC UNION POTTED PLANTS TO BE WATER SUPPLY P do T RELIEF VALVE 1 U(ONLY AT TR. 4 Pl.l SLOPE OF HORIZ. DRAINAGE PIPE 0 SIZE (inches) P.D.I. DESIGNATION MINIMUM SLOPE (inch per foot) FIXTURE UNITS 2-1/2 or less CONNECTION 1/4 SIOUX CHIEF 652 -A 3to6 Lit �e 1/8 B 8 or larger 12 -32 1/16 TABLE 704.1 OF THE FLORIDA PLUMBING CODE 2010 5 P1.1 WATER HAMMER ARRESTOR SCHEDULE 0 P1.1 P.D.I. DESIGNATION MANUF. & MODEL FIXTURE UNITS COLD WATER SUPPLY CONNECTION A SIOUX CHIEF 652 -A 1 -11 Lit �e 1/2" B SIOUX CHIEF 653 -B 12 -32 FULL FLOW BALL VALVES AND 3/4" C SIOUX CHIEF 654-C 33 -60 1" SIOUX CHIEF SHOCK ARRESTORS APPROVED FOR INSTALLATION WITH NO ACCESS DOOR REQUIRED. CONFORMS TO ANSI /ASSE 1010 STANDARDS. TYPICAL CONDENSATE DRAIN TRAP SCALE: N.T.S. ' * ; . 136 18" MIN 2" MIN OUT DRAIN PAN -i- \--DRAIN LINE SHALL BE AT LEAST THE 3" MIN SbyhNS&AS THE NIPPLE ON THE PLUMBING INDEX TYPICAL DRAWING 0 P1.1 1 P1.1 PLUMBING INDEX, NOTES, SCHEDULES AND DETAILS COLD WATER SUPPLY VACUUM RELIEF VALVE SHUT -OFF VALVE 2 P1.2 PLUMBING DETAILS Lit �e PROVIDE WITH QUARTER TURN 1 1 A "TACO" MODEL # 110B, 120V, 3 P2.1 FIRST FLOOR PLAN NEW CONSTRUCTION DOMESTIC WATER FULL FLOW BALL VALVES AND 60Hz, 10, 1/12 HP. 4 P2.2 FIRST FLOOR PLAN NEW CONSTRUCTION SANITARY PLAN. 5 P2.3 SECOND FLOOR PLAN NEW CONSTRUCTION PLUMBING PLAN. 7 WATTS SERIES PLT -5 6 P2.4 THIRD FLOOR PLAN NEW CONSTRUCTION PLUMBING PLAN. (2.1 GALLONS) 7 P2.5 FOURTH FLOOR PLAN NEW CONSTRUCTION DOMESTIC WATER .. o 8 P2.6 FOURTH FLOOR PLAN NEW CONSTRUCTION SANITARY PLAN. CHECK VALVE THERMAL EXPANSION TANK 0 9 P2.7 ROOF LEVEL PLAN NEW CONSTRUCTION PLUMBING PLAN WATTS SERIES PLT -5 10 P3.1 DOMESTIC WATER PIPING ISOMETRIC BALL VALVE (TYP.) HOT LINE 11 P3.2 SANITARY PIPING ISOMETRIC WATER TO HEAT TRAP � HEAT TRAP (TYP.) * - 12 P3.3 STORM DRAINAGE PIPING ISOMETRIC UNION / WATER SUPPLY P do T RELIEF VALVE SHUT -OFF VALVE J TO HEATER. ELECTRIC WATER HEATER �G DELETE IF PROVIDED P & T RELIEF SHOP DRAWING REQUIREMENTS 1. SHOP DRAWINGS, SHALL BE SUBMITTED COMPLETE, TOGETHER AT ONE TIME AND MUST COME THROUGH THE ARCHITECT. ALL SUBMITTALS SHALL BE MADE WITHIN 30 DAYS OF NOTICE TO PROCEED. 2. ALL SUBMITTALS MUST CLEARLY INDICATE EXACTLY WHICH ITEMS ARE BEING PROPOSED FOR USE. IF NOT, THE SUBMITTAL SHALL BE REJECTED. 3. SUBSTITUTIONS SHALL BE LIMITED TO ONE OF THE ALTERNATES LISTED IN THE CONSTRUCTION DOCUMENTS. PRODUCTS CONSIDERED TO BE EQUAL SHALL BE REVIEWED AND ACCEPTED BY THE ENGINEER, ARCHITECT AND OWNER (10) DAYS. PRIOR TO BID DATE. 4. THE CONTRACTOR ASSUMES ALL DESIGN RESPONSIBILITY AND ALL FINANCIAL RISKS FOR PROCEEDING PRIOR TO SHOP DRAWINGS PROCESSING, AND ON ANY ITEM OR WORK THAT IS AT VARIANCE TO THE CONSTRUCTION DOCUMENTS. 5. SHOP DRAWINGS AND SUBMITTALS FOR EACH ITEM SHALL BE REVIEWED NO MORE THAN TWICE. A THIRD SUBMITTAL ON AN ITEM MUST BE ACCOMPANIED BY A PURCHASE ORDER FROM THE CONTRACTOR OR IT SHALL BE REJECTED. 6. CIRCUMSTANCES NECESSITATING A REVISION TO THE PERMITTED DOCUMENTS NOT PROCESSED PRIOR TO INSTALLATION MAY NOT BE ACCEPTED. IF ACCEPTED IT MUST BE LEGIBLE, ACCURATE AND ACCOMPANIED BY A PURCHASE ORDER ORDER FROM THE CONTRACTOR. THE REVISION SHALL BE CHARGED TO THE CONTRACTOR AND DELIVERED TO HIM ON A C.O.D. BASIS. 7. SUBSTITUTIONS FROM THE BASE DESIGN OR VARIATIONS TO THE PERMITTED CONTRACT DOCUMENTS, WHETHER RESULTING FROM PROCESSED SHOP DRAWINGS OR NOT, THAT RESULT IN REQUIREMENTS IN LETTERS OF AUTHORIZATION AND /OR PERMIT CONTRACT DOCUMENT CHANGES MANDATED BY THE AUTHORITY HAVING JURISDICTION WILL NOT BE MADE BY THIS OFFICE UNLESS ACCOMPANIED BY A PURCHASE ORDER FROM THE CONTRACTOR, AND RELEASED ON A C.O.D. BASIS. 8. CONTRACTOR SHALL SUBMIT 5 COPIES OF SHOP DRAWINGS. 9 TYPICAL ELECTRICAL WATER HEATER DETAIL 707.14.' P1.1 NO SCALE FL. 33k4 COLD WATER SUPPLY VACUUM RELIEF VALVE SHUT -OFF VALVE INUNE CIRCULATING PUMP TO BE 3/4 7 HW WATTS MODEL 36-M1 Lit �e PROVIDE WITH QUARTER TURN 1 1 A "TACO" MODEL # 110B, 120V, 3/4" CW FINISHED CEILING FULL FLOW BALL VALVES AND 60Hz, 10, 1/12 HP. UNIONS (TYPICAL) THERMAL EXPANSION TANK 7 WATTS SERIES PLT -5 CHECK VALVE (2.1 GALLONS) .. o 3/4" HW HEAT TRAP* CHECK VALVE THERMAL EXPANSION TANK 0 HOT WATER WATTS SERIES PLT -5 SHUT -OFF VALVE RECIRCULATION (2.1 GALLONS) 0 BALL VALVE (TYP.) HOT LINE I XQ WATER TO HEAT TRAP � HEAT TRAP (TYP.) * - 0 SYSTEM. �- UNION / WATER SUPPLY P do T RELIEF VALVE SHUT -OFF VALVE J TO HEATER. ELECTRIC WATER HEATER �G DELETE IF PROVIDED P & T RELIEF 3/4w P & T RELIEF LINE WITH THE WATER HEATER VALVE. FULL SIZE 3/4" RELIEF DRAIN LINE TERMINATE OVER SERVICE SINK ELECTRIC WATER AIR GAP FITTING HEATER 3 BY�MANUFACT. PROVIDE A HARD COPPER RELIEF VALVE, SET HEATER WITHIN 24" X 24" X 4" DRAIN VALVE DISCHARGE AT EXTERIOR BUILDING DEEP GALVANIZED SHEET METAL DRAIN 1 6 0MIN. A.F.F PAN (24 GAGE MINIMUM) - DELETE IF PROVIDED 3/4" PLYWOOD BELOW I WITH THE WATER HEATER WATER HEATER DRAIN t I FLOOR WATER HEATER THERMOSTAT PAN AS PLATFORM 1 SHALL BE SET AT 110 F 2 "X 2 "X 1 /8" ANGLE IRON SIZE 11. I ANGLE 1 PROVIDE A 314 "HARD COPPER RELIEF VALVE. DISCHARGE 2 MIN. ABOVE MOP SINK 2 BRACKETS ) I I FOUNT FOR AIR GAP COMPLY HEATER 1" SAFETY PAN DRAIN LINE 53" A.F.F. TERMINATE OVER SERVICE SINK 1 "DRAIN LINE TERMINATED I 2 1/2" ANCHOR BOLT OR I 2"MIN. ABOVE MOP SINK FOR AIR GAP COMPLY EXPANSION BOLT (2 PER BRACKET) WATER HEATER SCHEDULE WATER HEATER SCHEDULE I.D. MANUFACTURER MODEL GALS VOLTAGE KW PHASE EFF REMARKS I.D. MANUFACTURER MODEL GALS. VOLTAGE KW PHASE EFF REMARKS EWH -1 LOCHINVAR E1TO50KK 50 208 4.5 1 0.92 FIRST FLOOR EWH -2 LOCHINVAR ES1030KK 30 208 4.5 1 0.93 FOURTH FLOOR G S cC P 0 Design Services For The Built Environment Atlanta Birmingham Cincinnati Columbus Dallas Fort Lauderdale Knoxville Jackson Jacksonville Louisville Memphis Nashville Richmond Tampa G R E S H A M SMITH AND P A R T N E R S 6030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 954.981.9100 FIRM'S FLORIDA CERT. NO. AAP000034 /CA3806 IB26000797/LC26000381 0 GEORGE SANJUAN, P.E. FLORIDA LICENSE #46100 DATE: 03/29/13 REVISION No. - Date - Revision Q02/01/13 Q03/15/13 707.14.' d du 1 City Comments Response FOft D FL. 33k4 (954).527-N 4610 :CA' / P000918 PTT. MGR: MICHAEL M %� ST F Lit �e PROJECT #: 1207177'i .� P is o0 Ljj m wQ 00 o O rn = XQ LO LL.I 0 GEORGE SANJUAN, P.E. FLORIDA LICENSE #46100 DATE: 03/29/13 REVISION No. - Date - Revision Q02/01/13 Q03/15/13 d du 1 City Comments Response Q3 03/29/13 I y ri nt e on I jam\ PLUMBING INDEX, NOTES, SCHEDULE AND DETAILS. FILE: PROJECT: 29080.00 DATE: 11/29/2012