13-96 (2)-042NOTE BOLT CONDENSING UNITS TO CONC. PAD TO WITHSTAND 150 MPH HURRICANE FORCE WANDS. 2ND. FLOOR 2ND. FLOOR `�� ��.r.yty,� .�':r.r.y {..:'it's' .�• �t.r.y.•.;,s'tt•:.�: ��� •:. 1 U-3 t L --- - - - - -- -- -- - - - - -- KrAHU-4 - - -- - - - -- -- FIN CLG. EXTERIOR WALL OR 5 REF. LINES TEL/DATA RM 18 GAGE METAL STRAPS MID.) DUCTLESS SPLIT SYSTEM \�Lff CONC. PAD AHU WALL MOUNTED 4 /CU) U -3,4 OR 5 SCH -40 PVC SLEEVE UNDERGROUND INSTALLATION SEAL BOTH ENDS 4" MI12" MIN. WATERTIGHT. SEE FLOOR PLAN FOR SIZE CONC. PAO 1ST. FLOOR �. �. . �• t .� i �•.� 1. r,,'•y►.;�:Ct•t• ... •r t•' '.fit „'•,. '` ISOMODE PAD BELOW GRADE 4” MIN. ALL AROUND DUCTLESS MINI -SPLIT SYSTEM 3 1 WALL MOUNTED INSTALLATION DETAIL M5.2 SCALE: N.T.S. NOTESi 1. FOR NEW ROOF CURB, PROVIDE (2) 3/8' THRU BOLTS, WITH WASHER AND NUT ON EACH SIDE OF CURB SECURED THRU CURB FLANGE, ROOF DECK AND ROOF JOIST, LAG BOLT TO CURB, MINIMUM 2 BOLTS PER SIDE. 20 GAUGE SHEET METAL. 2, INSTALL BURGLAR BARS IF REQUIRED PITCH TO OUTSIDE EDGE WOOD NAILER BOLTS THRU CURB ROOF DECK AND JOIST OR WELD CURB TO ROOF DECK. USE CONCRETE SAFETY SUPPORT ANCHORS IN POURED DECKS. CURB 8' MIN. ABOVE ROOF SURFACE ROOF DECK SPECIFIED DUCT SIZE ^\ I 1 7 ..• . j Ld ROOF JOIST SPECIFIED NUT METAL PLATE /WASHER DUCT SIZE ROOF CURB CAPPED DETAIL SCALE: N.T.S. O0UITORR TYPE 39 PiREAM TYPICAL ROOF CAPS b TYPICAL WALL CAP (� NOTES- I.- PROVIDE BADWAFT DAMPER w/ MMSOM Z- FLASH 3 SEAL WALL AND ROOF CAP 3.- PROVIDE INTERNAL ISOLATION AND SOUND INSULATION 4.- SUPPORT FAN FROM STRUMRE DUCTWORK CABINET CEILING EXHAUST FAN SCALE: N.T.S. OUTDOOR UNIT TERMINAL BOARD _ a J POWER SUPPLY CONDUIT AHU -3 & 4 (Less than 85 ft.) TERMINAL BOARD i = POWER: +j L ° 230/208 VAC 60 HZ Inn Inter Unit (conduit) 2 SCHEMATIC MINI -SPLIT UNIT WIRING M5.2 SCALE: N.T.S. BOLTING SCHEDULE LESS THAN OR EQUAL TO 500 LBS: Y4" x 3" TAPCONS 2 PER FOOT LESS THAN OR EQUAL TO 1500 LBS: 1/4 x 3 TAPCONS BUILDING EXTERIOR 4 PER FOOT WALL - - ------- mwm- LESS THAN OR EQUAL TO 2500 LBS: 5/8 WEDGE ANCHOR ATTACH AT CONNECTION POINTS CONDENSING UNIT Y4 "W SHEET METAL SCRE SECURE CONDENSING UNIT TO CONCRETE PAD WITH _ _ 1" WIDE GALVANIZED SHEETMETAL STRAPS MIN. X" THICKNESS __ ........ ------ _ SEE BOLTING SCHEDULE --- = FOR BOLTING REQUIREMENTS : .: : :.... or if v NEOPRENE VIBRATION ISOLATORS 4" MIN. THICK CONC. HOUSEKEEPING PAD REFRIGERANT LINES BELOW SLAB IN SCH. 40 PVC SLEEVE. SEE FLOOR PLAN FOR SIZES. (SEAL BOTH ENDS WATERTIGHT) TYPICAL CONDENSING UNIT MOUNTING DETAIL SCALE: N.T.S. REF. LINES TO AHU MD -2 MOTORIZED VOLUME l DAMPER �- MERV-13 FILTER RACK ; 1 r O P TO CO, SENSOR AT 44x24 R/A OPENING ABOVE DOOR (SEE DET, #3 THIS SHEET) �I SIP Soy 4 "RIGID DUCT NOTES: 1. PROVIDE 44x24 R /AOPENING SHEET). ABOVE DOOR IN CEIUNC S'ACL FOR -A-PU- 2. _ SEE DETAIL 0 T 2. PROVIDE MINIMUM 4" SERVICE/ MAINTENANCE AREA AROUND A :R HK40LING UNIT, 3. PROVIDE A WATER LEVEL DETECTION DEVICE THAT WILL SHUT OFF THE EQUIPMENT SERVED PRIOR TO OVERFLOW OF THE PAN, THE WATER -LEVEL DETECTION DEVICE SHALL CONNECT TO THE DRAIN PAN AT A HIGHER LEVE1 THAN THE PRIMARY DRAIN CONNECTION. - INSULATED LIQUID LINE SMOKE DETECTOR-IN SUPPLY AIR STREAM PROVIDE SMOOTH TRANSITION TO SUPPLY DUCT PROVIDE FLEXIBLE CONNEC110N AIR HANDLING UNIT. 4,- / TYPICAL REFRIGERANT LINES. A.H.U. =11 =a. TYPICAL SPRING TYPE VIBRATION ISOLATORS "KORFUWD" VIBRO- ISOLATOR, SERIES (LK) SEE DETAIL ABOVE AHU -2 VERTICAL AIR HANDLER DETAIL A, AHU -4B &AHU -5 INSULATED SUCTION LINE WEATHERPROOF FUSED DISCONNECT PER NEC POWER VENTILATION ACCSSORY POWER VENTILATION FRESH AIR 6 "RIGID DUCT PROVIDE A FACTORY FABRICATED ROOFCURB WITH O O1:;� R SERVICE SPACE J ENSURE 6 "(15cm) OF O� SPACE IF A DRAIN ,`��'�;. �Q HOSE IS TO BE USED. 70" ? POWER BREAKER OVER 1'8 "(50cm) CU -3, CU -4A, CU4B & CU -5 (CONCRETE OR SIMILAR MATERIAL) GROUND WIRE FASTEN WITH ANCHOR BOLTS (4 LOCATIONS) MINI -SPLIT CONDENSING UNIT DETAIL SCALE: N.T.S. SCALE: N.T.S. NOTE TO CONTRACTOR AND EQUIPMENT PROVIDER: EQUIPMENT MANUFACTURER TO PROVIDE CALCULATIONS AND ANCHORING DETAIL TO RESIST THE WIND PRESSURES IN ACCORDANCE WITH FBC. CONTRACTOR SHALL SECURE THE EQUIPMENT TO THE CURB AS PER MANUFACTURERS DETAIL CURB ATTACHMENT TO ROOF SHALL FOLLOW DETAILS IN STRUCTURAL PLANS. PROPER VIBRATION ISOLATORS. REFER TO RTU'S SCHEDULE FOR REQUIRED CURB HEIGHT. CANT STRIP W/ FLASHING CONDENSATE TRAP _ - _ ,• _ - PERFORATED CAP • - ' • T 1" DRAIN LINE INSULATED W/ - - 3/4" ARMAFLD( PIPE - INSULATION SUPPLY AIR DUCT TRANSmON Q j AS REQ'D. PROVIDE SMOKE DETECTOR TYPICAL EXTRACTOR TYPICAL SPUTTER DAMPER t GALVANIZED METAL /-- OUTSIDE AIR INTAKE OPENING WITH MOTORIZED DAMPER, WMS AND RAIN COVER. ROOF STRUCTURE CURB W /FLASHING RETURN AIR DUCT TRANSMON AS REQ'D. PROVIDE A WATER LEVEL DETECTION DEVICE CONNECTED TO THE DRAIN PAN PROVIDED WITH THE EQUIPMENT. SUCH WATER LEVEL DETECTION DEVICE WILL SHUT OFF THE EQUIPMENT SERVED PRIOR TO OVERFLOW OF THE PAN. POINT OF CONNECTION SHALL BE AT A HIGHER LEVEL THAN THE PRIMARY DRAIN CONNECTION. ROOFTOP PACKAGE A/C UNIT DETAIL SCALE: N.T.S. AHU -3, AHU 4 f h Design Services For The Built Environment Atlanta Birmingham Cincinnati Columbus Dallas Fort Lauderdale Knoxville Jackson Jacksonville Louisville Memphis Nashville Richmond Tampa G R E S H A M SMITH A N D P A R T N E R S 6030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 954.981.900 FIRM'S FLORIDA CERT. N0. AAP000034/CA3806 I826000797/LG26000381 DELTA G CONSULTING _ENGINEERS. INC. 707 N.E. 3rd AVE., SUITE 200 FORT i;.AUDERDALS, FL 39304 (964) 627 -1112 CA/00009181 PIT. YGB. IQCEAEL H00 PROJECT # : 120717 Uj LO I­ W o N 461 0 IDA',I.�C1�D18S;# o BOLTING SCHEDULE LESS THAN OR EQUAL TO 500 LBS: Y4" x 3" TAPCONS 2 PER FOOT LESS THAN OR EQUAL TO 1500 LBS: 1/4 x 3 TAPCONS BUILDING EXTERIOR 4 PER FOOT WALL - - ------- mwm- LESS THAN OR EQUAL TO 2500 LBS: 5/8 WEDGE ANCHOR ATTACH AT CONNECTION POINTS CONDENSING UNIT Y4 "W SHEET METAL SCRE SECURE CONDENSING UNIT TO CONCRETE PAD WITH _ _ 1" WIDE GALVANIZED SHEETMETAL STRAPS MIN. X" THICKNESS __ ........ ------ _ SEE BOLTING SCHEDULE --- = FOR BOLTING REQUIREMENTS : .: : :.... or if v NEOPRENE VIBRATION ISOLATORS 4" MIN. THICK CONC. HOUSEKEEPING PAD REFRIGERANT LINES BELOW SLAB IN SCH. 40 PVC SLEEVE. SEE FLOOR PLAN FOR SIZES. (SEAL BOTH ENDS WATERTIGHT) TYPICAL CONDENSING UNIT MOUNTING DETAIL SCALE: N.T.S. REF. LINES TO AHU MD -2 MOTORIZED VOLUME l DAMPER �- MERV-13 FILTER RACK ; 1 r O P TO CO, SENSOR AT 44x24 R/A OPENING ABOVE DOOR (SEE DET, #3 THIS SHEET) �I SIP Soy 4 "RIGID DUCT NOTES: 1. PROVIDE 44x24 R /AOPENING SHEET). ABOVE DOOR IN CEIUNC S'ACL FOR -A-PU- 2. _ SEE DETAIL 0 T 2. PROVIDE MINIMUM 4" SERVICE/ MAINTENANCE AREA AROUND A :R HK40LING UNIT, 3. PROVIDE A WATER LEVEL DETECTION DEVICE THAT WILL SHUT OFF THE EQUIPMENT SERVED PRIOR TO OVERFLOW OF THE PAN, THE WATER -LEVEL DETECTION DEVICE SHALL CONNECT TO THE DRAIN PAN AT A HIGHER LEVE1 THAN THE PRIMARY DRAIN CONNECTION. - INSULATED LIQUID LINE SMOKE DETECTOR-IN SUPPLY AIR STREAM PROVIDE SMOOTH TRANSITION TO SUPPLY DUCT PROVIDE FLEXIBLE CONNEC110N AIR HANDLING UNIT. 4,- / TYPICAL REFRIGERANT LINES. A.H.U. =11 =a. TYPICAL SPRING TYPE VIBRATION ISOLATORS "KORFUWD" VIBRO- ISOLATOR, SERIES (LK) SEE DETAIL ABOVE AHU -2 VERTICAL AIR HANDLER DETAIL A, AHU -4B &AHU -5 INSULATED SUCTION LINE WEATHERPROOF FUSED DISCONNECT PER NEC POWER VENTILATION ACCSSORY POWER VENTILATION FRESH AIR 6 "RIGID DUCT PROVIDE A FACTORY FABRICATED ROOFCURB WITH O O1:;� R SERVICE SPACE J ENSURE 6 "(15cm) OF O� SPACE IF A DRAIN ,`��'�;. �Q HOSE IS TO BE USED. 70" ? POWER BREAKER OVER 1'8 "(50cm) CU -3, CU -4A, CU4B & CU -5 (CONCRETE OR SIMILAR MATERIAL) GROUND WIRE FASTEN WITH ANCHOR BOLTS (4 LOCATIONS) MINI -SPLIT CONDENSING UNIT DETAIL SCALE: N.T.S. SCALE: N.T.S. NOTE TO CONTRACTOR AND EQUIPMENT PROVIDER: EQUIPMENT MANUFACTURER TO PROVIDE CALCULATIONS AND ANCHORING DETAIL TO RESIST THE WIND PRESSURES IN ACCORDANCE WITH FBC. CONTRACTOR SHALL SECURE THE EQUIPMENT TO THE CURB AS PER MANUFACTURERS DETAIL CURB ATTACHMENT TO ROOF SHALL FOLLOW DETAILS IN STRUCTURAL PLANS. PROPER VIBRATION ISOLATORS. REFER TO RTU'S SCHEDULE FOR REQUIRED CURB HEIGHT. CANT STRIP W/ FLASHING CONDENSATE TRAP _ - _ ,• _ - PERFORATED CAP • - ' • T 1" DRAIN LINE INSULATED W/ - - 3/4" ARMAFLD( PIPE - INSULATION SUPPLY AIR DUCT TRANSmON Q j AS REQ'D. PROVIDE SMOKE DETECTOR TYPICAL EXTRACTOR TYPICAL SPUTTER DAMPER t GALVANIZED METAL /-- OUTSIDE AIR INTAKE OPENING WITH MOTORIZED DAMPER, WMS AND RAIN COVER. ROOF STRUCTURE CURB W /FLASHING RETURN AIR DUCT TRANSMON AS REQ'D. PROVIDE A WATER LEVEL DETECTION DEVICE CONNECTED TO THE DRAIN PAN PROVIDED WITH THE EQUIPMENT. SUCH WATER LEVEL DETECTION DEVICE WILL SHUT OFF THE EQUIPMENT SERVED PRIOR TO OVERFLOW OF THE PAN. POINT OF CONNECTION SHALL BE AT A HIGHER LEVEL THAN THE PRIMARY DRAIN CONNECTION. ROOFTOP PACKAGE A/C UNIT DETAIL SCALE: N.T.S. AHU -3, AHU 4 f h Design Services For The Built Environment Atlanta Birmingham Cincinnati Columbus Dallas Fort Lauderdale Knoxville Jackson Jacksonville Louisville Memphis Nashville Richmond Tampa G R E S H A M SMITH A N D P A R T N E R S 6030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 954.981.900 FIRM'S FLORIDA CERT. N0. AAP000034/CA3806 I826000797/LG26000381 DELTA G CONSULTING _ENGINEERS. INC. 707 N.E. 3rd AVE., SUITE 200 FORT i;.AUDERDALS, FL 39304 (964) 627 -1112 CA/00009181 PIT. YGB. IQCEAEL H00 PROJECT # : 120717 Uj LO I­ W o N 461 0 IDA',I.�C1�D18S;# REVISION NQ. - Date - Revision MECHANICAL DETAILS PLAN 2 M5.2 FILE: PROJECT: 29080.00 DATE: 11/29/2012 48100 MECHANICAL DETAILS PLAN 2 M5.2 FILE: PROJECT: 29080.00 DATE: 11/29/2012