13-96 (2)-040TYPICAL TURNING VANE ON ALL ELBOWS CORNER ANGLE 1 TYPICAL DUCTWORK ELBOW TURNING 41 VANE DETAIL M5.1 SCALE: N.T.S. CAULK WATER TIGHT ALL GA HANGER STRAPS AROUND LOUVER. SEE HANGER SIZE METAL PIPE ARCH. PLANS FOR ALL 1" x VIV 8' -0" DETAILS OF WATERPROOFING- —CBS M. WALL 8' -0' if --I/— PLENUM COVER CAULK SURFACE 1" x 111r DL WALL LOUVER WITH MASKING TAPE OR S RUSKIN O '• \ W'A �ELF6735DXD— BIRDSCREEN 1 SUCH AS FIBERGLASS AIR AIR a W, (TO PREVENT SAGGING FLOW bF CAULK IF IT INTAKE OR EXHAUST ENOUGH TO SUPPORT OCCURS) (SEE NOTE 5 LOUVER SHALL BE 4" Q IY 0 WEIGHT OF CP -25 OR DEEP LOUVER WITH 30' Cf) - DRAINABLE BLADES. O SECTION VIEW EXTRUDED ALUMINUM y 1 WRAP OF Y (SOnxn) NOTES: W /BIRD SCREEN. MINIMUM OR WADE FS-195 WRAP / COORDINATE COLOR 112" AS SHOWN ON ,�. `- WITH ARCHITECT. FLOOR PLAN STRIP FLUSH TO EXTEF R ALUMINUM PANEL i CHA= NNEL TYPE SHOWN FLANGE TYPE IS SIMILAR OUTSIDE AIR INTAKE OR EXHAUST AIR LOUVER DETAIL SCALE: N.T.S. OA INTAKE PLENUM BOX DETAIL SCALE: N.T.S. METAL PIPE OR CONDUIT 2 OR 3 HOUR FIRE RATED CONCRETE FLOOR SLAB 2 HOUR RATED WALL 2 LAYERS OF 518' (1K5mm) THICK GGYPSUM WALL BOARD OR CONCRETE BLOCK WALL (SEE NOTE 4 FILL GAP COMPLETELY 2 OR 3 HOUR FIRE RATED AROUND PIPE MATH CAULK CONCRETE BLOCK WALL 1' (25mm) DEPTH CP -25 OR PUTTY 303 SUPPORTING CAULK CP -25 OR FLUSH TO SURFACE OF MATERIAL PUTTY 303 WITHN SLAB (SEE NOTE 3) WALL TYPICAL INSTALLATION DETAILS (A) RETAINING ANGLES: MINIMUM 1 -1/2' X 1 -1/2" X 0.054 (16 GA.) RETAINING ANGLES MUST OVERLAP STRUCTURE OPENI� 1" MINIMUM AND COVER CORNERS OF OPENINGS AS SI (B) CLEARANCE 1/8" PER LINEAR FOOT BOTH DIMENSIONS (C) STEEL SLEEVE: (D) APPROVED FIRE DAMPER (CURTAIN OR BLADE TYPE) (E) SECURE RETAINING ANGLES TO SLEEVE NO. 10 STEEL SCREWS (F) SECURE DAMPER TO SLEEVE ON 8" CENTERS WITH NO. 10 STEEL SCREWS (G) CONNECT DUCT TO SLEEVE WITH BREAKAWAY CONNECTION (H) FULLY GASKETED HINGED CAM LOCK FIRE DAMPER ACCESS DOOR. LABEL "FIRE DAMPER ACCESS". NOTE ALL SMOKE AND FIRE DAMPERS (UNDER 16" IN HEIGHT) SHALL BE OVERSIZED BY 2" AND TRANSITIONED DOWN TO DUCT SIZE TO MAXIMIZE FREE AREA. 2 "X3"X1, BY HVAG, GONTINUDUS ALL SIDES TYP. OF 2 �e. DUCT THRU WALL FIRE DAMPER DETAIL SYSTEM CONTROL FAN HAC POKIER OR CONTRO- THERMOSTAT 15 16 17 18 19 20 NOT ONO NO UNO AUXN.IARY ALARM CONTROL CONTACTS SHOWN N STANDBY CONTACTS TRANSFER DURING ALARM AS INDICATED BY THE ARROWS HVAC FAN CONTROL WIRING > > FOR SYSTEM SHUT -DOWN M5.1 SCALE: N.T.S. SCALE: N.T.S. 1 114r'. 25 GAGE HAN BAND CLAW WITH BA STRAP TILT' 1�1. DUCT MAY H TO PE OR MPER ICAL) UPPER ATTACHMENT PER SMACNA'--N,-., WNG NUT ARM O BEARING OPTION ROD_QONTNUOUS io[[or2;µLA►�PERs ROUND DAMPER OVER 1 DUI. ELEVATION DUCT E" TWO BLADE ARRANGMIT M.2 1/2' QUADRANT DUCT P11i aE�ANCE AMM 19' TO 4s• D NOTE OVER 12" NIGH USE MULTIPLE BLADES. EISn.B 6 OUTSDE END BEARING 3/$" QUADRANT DUCT 3/8' PN 12" MAX. 1 8' UP TO 18" MI A ASMD DUCT L—L DEPTH 7 T ME" FIG. A OR B NO>E 1_ INSIDE END BEARING RED oNwG. OVEIL OPTIONAL CT FOR OTHERS 2 VOLUME DAMPER M5.1 SCALE: N.T.S. 22 GA HANGER STRAPS DUCT SIZE HANGER SIZE METAL PIPE UP THRU 2 SF 1" x VIV 8' -0" 2 THRU 4 SF OR CONDUIT 8' -0' 4 THRU 10 SF 1" x VIr 6'—O' COVER CAULK SURFACE 1" x 111r 4W WITH MASKING TAPE OR S O '• \ W'A SUPPORTING MATERIAL BACKER ROD UNTIL •' /arrt�.1�.. SUCH AS FIBERGLASS CURBED (24-72 HOURS) INSULATION, BACKER ROD (TO PREVENT SAGGING OR SARNO. NEED ONLY bF CAULK IF IT ENOUGH TO SUPPORT OCCURS) (SEE NOTE 5 �_ • Q IY 0 WEIGHT OF CP -25 OR � m Cf) - PUTTY 303 O SECTION VIEW SECTION VIEW 1 WRAP OF Y (SOnxn) NOTES: .p � � Q WADE FS-195 WRAP / 1. FOR CONCRETE BLOCK WALLS, CENTER CAULK CP -25 OR PUTTY ,�. `- STRIP FLUSH TO EXTEF R 303 WITHIN WALL WITH DAMMINO ON BOTH SIDES. LO D L.Lj o GYPSUM PANEL (SEE 2. RECOMMENDATIONS BASED ON PROWCY PERFORMANCE PER ASTM NOTE 1) E -814 (UL 1479) FIRE TEST AND UL CLASSIFICATION FIRE STOP SYSTEMS 40,33 AND 91. 3. WET INSTALLED DEPTH OF CAULK CP -25 OR PUTTY 303 OFFENDS SULATED METAL PPE TYPE Nk SIZE OF PIPE. WET SIZE 1/Y (�13mm) MAX 8" 203mm 2 HRS. 852mm) 1 (25MM) MAX 6' 3 HRS. 4. UP TO 4OX SHRINKAGE OF CP-25 OR PUTTY 303 IS ACCEPTABLE AFTER WET DEPTH NSTALLATOON. SEAL ENTIRE RIDGE do) 5. OPTIONS TO MASKING TAPE TO PREVENT SAMO: SEAMS DAMMING MAETRIAL OVER PRODUCT TO LAYER OF CAUJC(CP -25 Hq,p� N OPENING. B. REMOVE PRODUCT FROM CONTAINER AND ALLOW To AIR CURE IN SMALL BATCHES FOR 12 HOURS. THEN HAND FORM INTO OPENING. 8. WHEN ANNULAR SPACE EXCEEDS W (19mm). A 28 AWO METAL SEC110N VIEW COVER PLATE MUST BE MECHANICALLY SECURED ATOP THE 3M FIRE BARRIER APPLICATION, OR TIGHTLY PACK A NON - COMBUSTIBLE DAMMING MATERIAL ATOP INSTALLED CAULK OR PUTTY. COVER PLATE NOT REQUIRED FOR 2 HOUR RATING UP TO 1W (47.6mm) ANNULAR SPACE 3 PIPE SLEEVE DETAIL M5.1 SCALE: N.T.S. TYPICAL INSTALLATION DETAILS (A) RETAINING ANGLES: MINIMUM 1 -1/2' X 1 -1/2" X 0.054 (16 GA.) RETAINING ANGLES MUST OVERLAP STRUCTURE OPENI� 1" MINIMUM AND COVER CORNERS OF OPENINGS AS SI (B) CLEARANCE 1/8" PER LINEAR FOOT BOTH DIMENSIONS (C) STEEL SLEEVE: (D) APPROVED FIRE DAMPER (CURTAIN OR BLADE TYPE) (E) SECURE RETAINING ANGLES TO SLEEVE NO. 10 STEEL SCREWS (F) SECURE DAMPER TO SLEEVE ON 8" CENTERS WITH NO. 10 STEEL SCREWS (G) CONNECT DUCT TO SLEEVE WITH BREAKAWAY CONNECTION (H) FULLY GASKETED HINGED CAM LOCK FIRE DAMPER ACCESS DOOR. LABEL "FIRE DAMPER ACCESS". NOTE ALL SMOKE AND FIRE DAMPERS (UNDER 16" IN HEIGHT) SHALL BE OVERSIZED BY 2" AND TRANSITIONED DOWN TO DUCT SIZE TO MAXIMIZE FREE AREA. 2 "X3"X1, BY HVAG, GONTINUDUS ALL SIDES TYP. OF 2 �e. DUCT THRU WALL FIRE DAMPER DETAIL SYSTEM CONTROL FAN HAC POKIER OR CONTRO- THERMOSTAT 15 16 17 18 19 20 NOT ONO NO UNO AUXN.IARY ALARM CONTROL CONTACTS SHOWN N STANDBY CONTACTS TRANSFER DURING ALARM AS INDICATED BY THE ARROWS HVAC FAN CONTROL WIRING > > FOR SYSTEM SHUT -DOWN M5.1 SCALE: N.T.S. SCALE: N.T.S. 1 114r'. 25 GAGE HAN BAND CLAW WITH BA STRAP TILT' 1�1. DUCT MAY H TO PE OR MPER ICAL) UPPER ATTACHMENT PER SMACNA'--N,-., WNG NUT ARM O BEARING OPTION ROD_QONTNUOUS io[[or2;µLA►�PERs ROUND DAMPER OVER 1 DUI. ELEVATION DUCT E" TWO BLADE ARRANGMIT M.2 1/2' QUADRANT DUCT P11i aE�ANCE AMM 19' TO 4s• D NOTE OVER 12" NIGH USE MULTIPLE BLADES. EISn.B 6 OUTSDE END BEARING 3/$" QUADRANT DUCT 3/8' PN 12" MAX. 1 8' UP TO 18" MI A ASMD DUCT L—L DEPTH 7 T ME" FIG. A OR B NO>E 1_ INSIDE END BEARING RED oNwG. OVEIL OPTIONAL CT FOR OTHERS 2 VOLUME DAMPER M5.1 SCALE: N.T.S. 22 GA HANGER STRAPS DUCT SIZE HANGER SIZE MAX SPACING UP THRU 2 SF 1" x VIV 8' -0" 2 THRU 4 SF 1" x IN 8' -0' 4 THRU 10 SF 1" x VIr 6'—O' OVER 10 SF 1" x 111r 4W tom. HANG DUCTS ACCORDING TO SMACNA STANDARDS TYPICAL HANGING STRAP AND SADDLE HANGING DETAIL SECURE WIRE TYPICAL Z BAR AND WARE DUCT HANGING DETAIL 10'f MAX. TYPICAL CHANNEL NO STRAP DUCT HANGING DETAIL METHOD OF HANGING DUCTS DETAIL SCALE: N.T.S. DUCT SEALER AT 45" TAKEOFF ROUND BELLMOUTH COLLAR OR ROUND BELLMOUTH COLLAR OII�l 1TOJN�SIDE OF DUCT CONNECTION TO MAIN —=fir SLIPPY AIR DUCT- MAXIMUM D/8 OFFSET ALLOWED IN LAST D INCHES TO DEVICE WHERE D IS THE INTERNAL FLEX DIAMETER MIN. 1" WIDE 22 GAUGE GALV. STEEL STRAP VOLUME DAMPER W/ LOCKING HANGER AS PER SMACNA FIG. 3 -10 QUADRANT ek 2" STANDOFF NECK SIZE TO ADJUSTABLE STAIN. STL CLAMP ADJUSTABLE STAIN. STL MATCH FLEX DUCT CLAMP SIZE INDICA DUCT SEALER INSULATE TOP PANEL OF DIFFUSER OR FULLY HINGED & GASKETED GRILLE— TAPE TO CEILING GRID WITH SILVER CEILING 24" X 24" ACCESS FOIL TAPE DOOR FOR DAMPERS IN NON — ACCESSIBLE CEILINGS CEILING (T —BAR SHOWN. GYP. AIR DISTRIBUTION DEVICE LAYIN SHOWN. If1I�/ BOARD SIMILAR) SURFACE MOUNT SIMILAR llfiiri,"i I. FU X13LE DUCTS SHALL BE ONE PIECE AND SHALL NOT BE SPLICED TOGEM3L 2. EXTEND FLEXIBLE DUCE INSULATION TO DUCT /DIFFUSER PANEL INSULATION AND SEAL WITH MASTIC. 3. FLEXIBLE NR DUCT "= NOT EXCEED 8 FT. WHEN EXTENDED. ELBOW RADIUS S(ZED FOR ND LESS THAN R/D - 1.0. 4. MAXIMUM SAG OF FLEXIBLE DUCT BETWEEN SUPPORTS SHALL BE 1/2" PER FOOT. 5. MINIMUM 1' WIDE 22 GAUGE GALVANIZED STRAP HANGER WITH HEMMED EVES IN ACCORDANCE WITH SMACNA FIGURE B-10. FLEXIBLE DUCT TAKEOFF DETAIL SCALE: N.T.S. FROM FLOOR DUCT GAUGE 28, 26 24,22,20 18,16 ALLOWABLE LOAD PER FASTENER 25 LBS. 35 LBS. 50 LBS. X a 1", Y - 2" ADD OTHERS TO ACCOMIDATE LOAD. MINIMUM OF 3 ON 24" WIDE DUCT ADD ALONG SIDES NEAREST ANCHORS. DUCT RISER SUPPORTS SCALE: N.T.S. FLOW ` DUCT COLLAR SOUND INSULATION TITUS ®INSULATED HIGH RECTANGULAR LINEAR ADAPTER. SUSPENDED TECHZONE ®CEILING. TITUSOML -37 OR 38 LINEAR DIFFUSER. LINEAR DIFFUSER MOUNTING DETAIL LIQUID LINE CONC SLAB •� -STEEL SLEEVE FILL SLEEVE WITH FIRE— PROOF/ FIRE RESISTANT SILICON SEALANT FOAL CTC. PR -855 20 GAUGE SHEET —METAL (SIZE AS REQ'D) FLASHING AS RECOM. BY MANUF. SCALE: N.T.S. 25/50 RATED INSUJLATION SUCTION LINE ► /Y/[ / / / /1N /1 /YNi V -- --- [I / //]IIfI// /lI�.�I�I.IV.• 1111 • 1 1 I � REFRIGERANT LINES FROM ACCU'S SCALE: N.T.S. G S & P Design Services For The Built Environment Atlanta Birmingham Cincinnati Columbus Dallas Fort Lauderdale Knoxville Jackson Jacksonville Louisville Memphis Nashville Richmond Tampa El G R E S H A M S M I T H A N D P A R T N E R S 6030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 954.981.9100 FIRM'S FLORIDA CERT. NO. AAP000034 /CA3806 I B 2 6 0 0 0 7 9 7/L C 2 6 0 0 0 3 8 1 ' SUSPENDED TECHZONE® • LTING CEILING. '•• �TITUS ®MLR FLOW -XX RETURN FORT U UtE� 1FI:,Q 333b4z; AIR LINEAR DIFFUSER. R/A UNEAR DIFFUSER FLOW ` DUCT COLLAR SOUND INSULATION TITUS ®INSULATED HIGH RECTANGULAR LINEAR ADAPTER. SUSPENDED TECHZONE ®CEILING. TITUSOML -37 OR 38 LINEAR DIFFUSER. LINEAR DIFFUSER MOUNTING DETAIL LIQUID LINE CONC SLAB •� -STEEL SLEEVE FILL SLEEVE WITH FIRE— PROOF/ FIRE RESISTANT SILICON SEALANT FOAL CTC. PR -855 20 GAUGE SHEET —METAL (SIZE AS REQ'D) FLASHING AS RECOM. BY MANUF. SCALE: N.T.S. 25/50 RATED INSUJLATION SUCTION LINE ► /Y/[ / / / /1N /1 /YNi V -- --- [I / //]IIfI// /lI�.�I�I.IV.• 1111 • 1 1 I � REFRIGERANT LINES FROM ACCU'S SCALE: N.T.S. G S & P Design Services For The Built Environment Atlanta Birmingham Cincinnati Columbus Dallas Fort Lauderdale Knoxville Jackson Jacksonville Louisville Memphis Nashville Richmond Tampa El G R E S H A M S M I T H A N D P A R T N E R S 6030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 954.981.9100 FIRM'S FLORIDA CERT. NO. AAP000034 /CA3806 I B 2 6 0 0 0 7 9 7/L C 2 6 0 0 0 3 8 1 GEORGE SANJUAN, P.E. FLORIDA LICENSE #46100 DATE: 02/01/13 REVISION No. - Date - Revision 1 02/01/13 ; Addendum #1 - - - -- - - — - - - -- - - I MECHANICAL DETAILS PLAN 1 M501 FILE: PROJECT: 29080.00 DATE: 1 1 /29/201 2 ' DELTA, G`�.* • • LTING ENGi' '•• • • 707,.146. arcj� jj,�': SUl •P60 FORT U UtE� 1FI:,Q 333b4z; (9)-75207 i� 2' • CA S O '• \ PJT. MGR: MICHAE H L PROJECT #: 120717 o T�•�� r, •' /arrt�.1�.. Uj Co Li.I ® �_ • Q IY 0 � m Cf) - O f 4� .p � � Q ,�. `- X LO D L.Lj o GEORGE SANJUAN, P.E. FLORIDA LICENSE #46100 DATE: 02/01/13 REVISION No. - Date - Revision 1 02/01/13 ; Addendum #1 - - - -- - - — - - - -- - - I MECHANICAL DETAILS PLAN 1 M501 FILE: PROJECT: 29080.00 DATE: 1 1 /29/201 2