AIR DISTRIBUTION SCHEDULE
SYMBOL
USE
TYPE
DESGN �ACTUiER
SIZE
REMARICS
ACCESSORIES
CD
SUPPLY
ELBOW WITH "AIRFOIL" TURNING VANES
T"
- LAY N - 24X24 MODULE
V
CEILING GRILLE (CG)
AR
DIFFUSERS
TRW TDC -AA
SEE PLANS
- ROUND NECK
O.B.D.
CG
CEILING
GRILLE
GRILLES
TITUS 250-AA
SEE PLANS
SURFACE MOUNT
O.B.D.
SIR
SUPPLY
AR
MOTORIZED DAMPER
TITUS 30OFS
SEE PLANS
---
O,BA
7
VARIABLE AIR VOLUME BOX
REGISTERS
BACKDRAFT (GRAVITY OR MOTOR) DAMPER
INUNE EXHAUST FAN
M3.1 PARTIAL FIRST FLOOR NEW CONSTRUCTION MECHANICAL PLAN
RAG
RETURN
AR
GRILLES &
REGISTERS
TITUS 350FL
PLANS
SURFACE MOUNT
LD
SUPPLY
LINEAR BAR
DIFFUSER
�Myw ML-39
SEE PLANS
SURFACE MOUNT
---
RD
RETURN
LINEAR BAR
DIFFUSER
TITUS MLR -39 1
SEE PLANS
SURFACE MOUNT
---
EG
EXHAUST
13
M5.1 MECHANICAL DETAILS PLAN 1
---
14
GRILLE
GRILLES
5OF
SEE PLANS
M
M5.3 MECHANICAL DETAILS PLAN 3
DAL
0/A INTAKE
GREENHUX
W/b.G PRODUCT
LOUVER
LOUVER
D -WAD
APPROVAL
EAL
EXHAUST AR
GREENHECK
W/b.C. PRODUCT
LOUVER
LOUVER
EHH -601D
SEE aANS
APPROVAL
GENERAL MID HVAC CONTRACTOR TO COORDINATE FINISH AND USED WHITE COLOR OF ALL AR DMTRBU71ON
PRODUCTS PRIOR TO ORDERIK ALL DFFUSERS SHALL HAVE WITE FINISH.
AIR DISTRIBUTION / DUCTWORK NOTES
1. REFER TO ARCHITECTURAL PLANS FOR CEILING TYPE.
2. PROVIDE OFF WHITE FINISH (SUBJECT TO ARCHITECTS APPROVAL).
3. ALL DUCTWORK WHERE ALLOWED BY LOCAL CODES AND CEILING RATING SHALL BE AS
FOLLOWS:
A. S/A - R/A INSULATED G90 GALVANIZED G22 SHTMTL. 2% 1LB DENSITY
B. EXHAUST AIR DUCTWORK - G90 GALVANIZED G24 SHEETMETAL
C. INSULATIO THICKNESS QENSI
(INC HES) (PC F)
OUTSIDE AIR INTAKE DUCTS - N/A N/A
EXHAUST DUCTS BLANKET N/A N/A
SUPPLY AIR DUCTS INT LINING 2 1
(CONCEALED WITHIN BLDG. ENVELOPE)
4. ALL DUCTWORK AND DIFFUSERS SHALL BE RATED FOR THE USE, PRESSURE AND
TEMPERATURE SPECIFIED AND AS REQUIRED BY THE CEILING SYSTEM RATING.
5. ALL DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH "SMACNA"
STANDARDS AND LOCAL BUILDING CODES.
6. ALL DUCT SIZES ARE CLEAR INSIDE DIMENSIONS.
7. SEAL ALL DUCTS, JOINTS AND SEAMS IN AN APPROVED MANNER AND INSURE AGAINST
LEAKAGE.
8. PROVIDE ACCESS DOORS AS REQUIRED FOR ALL MECHANICAL EQUIPMENT TO SERVICE
AND VISUALLY CHECK ROTATION OF FANS AND MOTORS, POSITION OF DAMPERS,
REPLACE FIRE DAMPER LINKS, ADJUST OR REPLACE CONTROLS, ETC.
9. PROVIDE VANED ELBOWS IN ALL CASES, SPUTTER DAMPERS WHERE INDICATED ON
DRAWINGS AND VOLUME CONTROL DAMPERS IN ALL BRANCH DUCTS OR DIFFUSER
CONNECTIONS.
MECHANICAL LEGEND
GENERAL NOTES: f
1. ALL MECHANICAL SYSTEMS ARE TO BE INSTALLED IN ACCORDANCE WITH ALL
APPLICABLE SECTIONS OF THE NFPA STANDARDS, ANSI STANDARDS, THE LOCAL
BUILDING CODE, NOISE & HEIGHT ORDINANCES, PLANS AND SPECIFICATIONS.
2. ALL MATERIALS SHALL BE NEW AND ALL WORKMANSHIP AND MATERIALS SHAD_ BE IN
STRICT ACCORDANCE WITH APPLICABLE LOCAL CODES, PRODUCT APPROVAL, RULES AND
ORDINANCES, ANY DAMAGED EQUIPMENT SHALL BE REPLACED OR RESTORED TO
ORIGINAL CONDITION.
3. THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, ACCESS
PANELS, CONTROL SYSTEMS, DEVICES, PERMITS AND SERVICES NECESSARY FOR
FURNISHING AND INSTALLING A COMPLETE OPERABLE MECHANICAL SYSTEM.
4. ALL LOUVERS, GRILLES, PIPING, ETC. SHALL BE PAINTED TO MATCH SURROUNDING
COLOR AND TEXTURES AS REQUIRED BY ARCHITECT. VERIFY COLOR AND TEXTURE WITH
ARCHITECT. PAINT ALL EXPOSED MECHANICAL EQUIPMENT WITH BENJAMIN MOORE
EPDXY ENAMEL 182.
5. ALL CUTTING, PATCHING, STRUCTURAL STEEL, WEATHER PROOFING, PAINTING, AND WALL
OPENINGS SHALL BE BY THE GENERAL CONTRACTOR.
6. ALL OPENINGS IN BUILDING STRUCTURE, FOR DUCTWORK, PIPING, ETC. TO BE 1/2"
LARGER (ON ALL SIDES) THEN THE OUTSIDE DIMENSIONS. FILL VOIDS WITH FIRE
RETARDANT SIUCONE FOAM (I.E. CHASE -FOAM CTC PR -855 BY CHASE TECHNOLOGY
CORP.).
7. BUILDING HVAC CALCULATIONS ARE BASED ON THE FOLLOWING:
A. INDOOR DESIGN: SUMMER 75 DDB /50% RH, WINTER 72 DDB.
B. OUTDOOR DESIGN: SUMMER 91 DDB /78 DWB, WINTER 42 DDB.
C. BUILDING CONDITIONS:
GLASS U VALUE 0.56
GLASS S.C. 0.53
WALL U VALUE 0.20
ROOF U VALUE 0.03
PEOPLE 1 ST FUR: 44 4TH FUR: 49
OUTSIDE AIR 13 CFM PER SQ. FT.
LIGHTS 1.1 W /SQ.FT.
8. PROVIDE FLEXIBLE DUCT CONNECTORS, RATED AS REQUIRED, TO ALL FANS, A/C UNITS,
OR MECHANICAL EQUIPMENT.
9. PROVIDE MAINTENANCE AND OPERATION MANUAL ON ALL MECHANICAL EQUIPMENT OR
SYSTEMS. PROVIDE 5 SETS OF SUBMITTALS ON ALL HVAC EQUIPMENT. SUBMITTALS
SHALL HAVE A SUMMARY SHEET SHOWING ALL SCHEDULED INFORMATION.
10. HVAC CONTRACTOR WILL WARRANTY ALL MECHANICAL SYSTEMS, DUCTWORK,
THERMOSTATS, AND ALL OTHER EQUIPMENT,PARTS AND LABOR UNDER THESE DRAWINGS
AND SPECIFICATIONS FOR A PERIOD OF ONE (1) YEAR AFTER C.O. OF BUILDING. ANY
REPAIRS REQUIRING SYSTEM SHUT DOWN WILL BE DONE DURING NON OPERATIONAL
PERIODS. HVAC CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES PRIOR TO
BIDDING AND PURCHASING ANY EQUIPMENT.
11. AIR QUALITY SHOULD BE TESTED BEFORE OCCUPANCY AND SHOULD BE INSTRUMENTED
AND MONITORED THEREAFTER, OR AT LEAST AT REGULAR INTERVALS
MECHANICAL EQUIPMENT NOTES:
1. ALL MECHANICAL EQUIPMENT SHALL BE ARI & U.L LISTED WHERE APPLICABLE AND
RATED FOR THE REQUIRED SERVICE, PRESSURES, TEMPERATURES, AND SHALL BE
PROVIDED WITH ALL NECESSARY TRANSFORMERS, SEALS, VALVES, CONNECTIONS. ETC.
TO FUNCTION PROPERLY.
2. PROVIDE SMOKE DETECTORS WITH ACCESS DOORS IN ALL SUPPLY AIR DUCTS FOR FANS
AND AHU'S OF 2000 CFM OR ABOVE. ALL SMOKE DETECTORS SHALL BE BY ONE
MANUFACTURER; COORDINATE VOLTAGE ETC. WITH ELECTRICAL CONTRACTOR AND FIRE
ALARM SYSTEM BEFORE ORDERING. UPON DETECTION, SMOKE DETECTORS SHALL SHUT
DOWN ASSOCIATED AIR MOVING EQUIPMENT.
3. PROVIDE TYPE "B" FIRE DAMPERS IN ALL DUCTS OR OPENINGS PENETRATING FIRE
RATED WALLS, PARTITIONS, FLOORS OR ROOF SLABS AND AT FRESH AIR INTAKES IF
REQUIRED (SEE ARCHITECTS PLANS FOR RATINGS). PROVIDE RADIATION DAMPERS IN
RATED CEILINGS FOR ALL CEILING OPENINGS, CEILING FANS, DIFFUSERS OR GRILLES
RATED FOR USE IN THE CEILING ASSEMBLY AS SPECIFIED BY ARCHITECT.
4. PROVIDE BACKDRAFT DAMPERS ON ALL EXHAUST FANS AND /OR INUNE FANS.
5. PROVIDE VIBRATION ISOLATORS ON ALL MECHANICAL EQUIPMENT AS CALLED FOR
IN THE SPECIFICATIONS. IF NOT SPECIFIED, AS RECOMMENDED BY MANUFACTURER FOR
QUIET OPERATION (WITH 99% ISOLATION EFFICIENCY).
6. PROVIDE A MIN. OF 10' CLEARANCE BETWEEN 0/A INTAKES AND VTR OR EXHAUST
OPENINGS.
7. INDEPENDENT CONTRACTOR SHALL TEST AND BALANCE ALL MECHANICAL EQUIPMENT
AIR DEVICES. EXTRACTORS. DAMPERS. AHU'S & FAN RATES. ETC. TO PROVIDE THE
DESIGN QUANTITIES AS SHOWN ON THE PLANS OR SCHEDULES. PROVIDE T & B
REPORT IN ACCORDANCE WITH THE AIR BALANCE COUNCIL STANDARDS. PROVIDE FINAL
BALANCING FOR ALL SYSTEMS TO SATISFACTION OF OWNER AND ENGINEER. T & B
CONTRACTOR SHALL VISIT JOB SITE DURING CONSTRUCTION TO ENSURE THAT ALL
DUCTS. DAMPERS. ETC. ARE INSTALLED FOR PROPER AND QUIET AIR DELIVERY.
8. THERMOSTAT LOCATION SHALL BE APPROVED BY OWNER AND ENGINEER BEFORE
INSTALLATION.
9. RUN INSULATED CONDENSATE DRAINS AS PER PLUMBING DRAWINGS.
10. NOT USED.
11. ALL PIPING AND DUCTWORK SHALL BE SLEEVED THRU WALLS, BEAMS, SLABS, ETC, AS
REQUIRED AND COORDINATED WITH THE STRUCTURAL ENGINEER. REWORK BAR JOIST
CROSS BRACING AND PROVIDE NECESSARY TRANSITIONS AS REQUIRED FOR DUCTWORK
INSTALLATION.
12. ALL INSULATION WILL HAVE FIRE /SMOKE RATING LESS THAN 25/50.
13. PROVIDE MOTOR STARTERS AS FOLLOWS (UNLESS OTHERWISE RECOMMENDED BY
MOTOR MANUFACTURER):
A: PROVIDE OVERLOAD PROTECTION - 1/3 HP AND ABOVE (ALL PHASES).
B: PROVIDE ACROSS THE LINE VOLTAGE STARTING BELOW 25 HP.
14. ALL OUTDOOR EQUIPMENT SHALL COMPLY WITH LOCAL ZONING NOISE ORDINANCES.
MIN. REQUIREMENT SHALL NOT EXCEED A NOISE LEVEL OF 65 DB AS MEASURED
RADIALLY 30 FT FROM THE EQUIPMENT IN ALL DIRECTIONS.
15. FILTERS SHALL BE IN PLACE DURING CONSTRUCTION. PROVIDE A NEW SET PRIOR TO
TEST AND BALANCE AND A FINAL SET AT THE END OF ONE YEAR SERVICE PERIOD.
r''
MECHANICAL INDEX
NEW WORK
DRWI r
NEW DUCTWORK
�
DOUBLE WALL INSULATED
1
DUCTWORK
SUPPLY /RETURN AIR DUCTWORK
ELBOW WITH "AIRFOIL" TURNING VANES
T"
FLEXIBLE DUCTWORK
V
CEILING GRILLE (CG)
3
UNEAR DIFFUSER SUPPLY
FIRE STOPPING
UNEAR DIFFUSER RETURN
EXHAUST GRILLE
®
AUDIO /VISUAL ALARM
FOR DUCT SMOKE DETECTOR
eAIR
INLET - OUTLET TYPE /CFM
r-
VOLUME DAMPER
MOTORIZED DAMPER
SD
DUCT SMOKE DETECTOR
-�
FIRE DAMPER /ACCESS DOOR (FD /AD)
7
VARIABLE AIR VOLUME BOX
L�
BACKDRAFT (GRAVITY OR MOTOR) DAMPER
INUNE EXHAUST FAN
M3.1 PARTIAL FIRST FLOOR NEW CONSTRUCTION MECHANICAL PLAN
R/A OPENING ABOVE FINISH CEIUNG
IN R/A PLENUM.
OT
THERMOSTAT
T S
T1iERMOSTAT WITH INTEGRATED TEMPERATURE SENSOR
OHUMIDISTAT
10
OKEY
NOTE
CONNECT TO EXISTING
CG
CEILING GRILLE
EG
EXHAUST GRILLE
A.P.
ACCESS PANEL
GENERAL NOTES: f
1. ALL MECHANICAL SYSTEMS ARE TO BE INSTALLED IN ACCORDANCE WITH ALL
APPLICABLE SECTIONS OF THE NFPA STANDARDS, ANSI STANDARDS, THE LOCAL
BUILDING CODE, NOISE & HEIGHT ORDINANCES, PLANS AND SPECIFICATIONS.
2. ALL MATERIALS SHALL BE NEW AND ALL WORKMANSHIP AND MATERIALS SHAD_ BE IN
STRICT ACCORDANCE WITH APPLICABLE LOCAL CODES, PRODUCT APPROVAL, RULES AND
ORDINANCES, ANY DAMAGED EQUIPMENT SHALL BE REPLACED OR RESTORED TO
ORIGINAL CONDITION.
3. THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, ACCESS
PANELS, CONTROL SYSTEMS, DEVICES, PERMITS AND SERVICES NECESSARY FOR
FURNISHING AND INSTALLING A COMPLETE OPERABLE MECHANICAL SYSTEM.
4. ALL LOUVERS, GRILLES, PIPING, ETC. SHALL BE PAINTED TO MATCH SURROUNDING
COLOR AND TEXTURES AS REQUIRED BY ARCHITECT. VERIFY COLOR AND TEXTURE WITH
ARCHITECT. PAINT ALL EXPOSED MECHANICAL EQUIPMENT WITH BENJAMIN MOORE
EPDXY ENAMEL 182.
5. ALL CUTTING, PATCHING, STRUCTURAL STEEL, WEATHER PROOFING, PAINTING, AND WALL
OPENINGS SHALL BE BY THE GENERAL CONTRACTOR.
6. ALL OPENINGS IN BUILDING STRUCTURE, FOR DUCTWORK, PIPING, ETC. TO BE 1/2"
LARGER (ON ALL SIDES) THEN THE OUTSIDE DIMENSIONS. FILL VOIDS WITH FIRE
RETARDANT SIUCONE FOAM (I.E. CHASE -FOAM CTC PR -855 BY CHASE TECHNOLOGY
CORP.).
7. BUILDING HVAC CALCULATIONS ARE BASED ON THE FOLLOWING:
A. INDOOR DESIGN: SUMMER 75 DDB /50% RH, WINTER 72 DDB.
B. OUTDOOR DESIGN: SUMMER 91 DDB /78 DWB, WINTER 42 DDB.
C. BUILDING CONDITIONS:
GLASS U VALUE 0.56
GLASS S.C. 0.53
WALL U VALUE 0.20
ROOF U VALUE 0.03
PEOPLE 1 ST FUR: 44 4TH FUR: 49
OUTSIDE AIR 13 CFM PER SQ. FT.
LIGHTS 1.1 W /SQ.FT.
8. PROVIDE FLEXIBLE DUCT CONNECTORS, RATED AS REQUIRED, TO ALL FANS, A/C UNITS,
OR MECHANICAL EQUIPMENT.
9. PROVIDE MAINTENANCE AND OPERATION MANUAL ON ALL MECHANICAL EQUIPMENT OR
SYSTEMS. PROVIDE 5 SETS OF SUBMITTALS ON ALL HVAC EQUIPMENT. SUBMITTALS
SHALL HAVE A SUMMARY SHEET SHOWING ALL SCHEDULED INFORMATION.
10. HVAC CONTRACTOR WILL WARRANTY ALL MECHANICAL SYSTEMS, DUCTWORK,
THERMOSTATS, AND ALL OTHER EQUIPMENT,PARTS AND LABOR UNDER THESE DRAWINGS
AND SPECIFICATIONS FOR A PERIOD OF ONE (1) YEAR AFTER C.O. OF BUILDING. ANY
REPAIRS REQUIRING SYSTEM SHUT DOWN WILL BE DONE DURING NON OPERATIONAL
PERIODS. HVAC CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES PRIOR TO
BIDDING AND PURCHASING ANY EQUIPMENT.
11. AIR QUALITY SHOULD BE TESTED BEFORE OCCUPANCY AND SHOULD BE INSTRUMENTED
AND MONITORED THEREAFTER, OR AT LEAST AT REGULAR INTERVALS
MECHANICAL EQUIPMENT NOTES:
1. ALL MECHANICAL EQUIPMENT SHALL BE ARI & U.L LISTED WHERE APPLICABLE AND
RATED FOR THE REQUIRED SERVICE, PRESSURES, TEMPERATURES, AND SHALL BE
PROVIDED WITH ALL NECESSARY TRANSFORMERS, SEALS, VALVES, CONNECTIONS. ETC.
TO FUNCTION PROPERLY.
2. PROVIDE SMOKE DETECTORS WITH ACCESS DOORS IN ALL SUPPLY AIR DUCTS FOR FANS
AND AHU'S OF 2000 CFM OR ABOVE. ALL SMOKE DETECTORS SHALL BE BY ONE
MANUFACTURER; COORDINATE VOLTAGE ETC. WITH ELECTRICAL CONTRACTOR AND FIRE
ALARM SYSTEM BEFORE ORDERING. UPON DETECTION, SMOKE DETECTORS SHALL SHUT
DOWN ASSOCIATED AIR MOVING EQUIPMENT.
3. PROVIDE TYPE "B" FIRE DAMPERS IN ALL DUCTS OR OPENINGS PENETRATING FIRE
RATED WALLS, PARTITIONS, FLOORS OR ROOF SLABS AND AT FRESH AIR INTAKES IF
REQUIRED (SEE ARCHITECTS PLANS FOR RATINGS). PROVIDE RADIATION DAMPERS IN
RATED CEILINGS FOR ALL CEILING OPENINGS, CEILING FANS, DIFFUSERS OR GRILLES
RATED FOR USE IN THE CEILING ASSEMBLY AS SPECIFIED BY ARCHITECT.
4. PROVIDE BACKDRAFT DAMPERS ON ALL EXHAUST FANS AND /OR INUNE FANS.
5. PROVIDE VIBRATION ISOLATORS ON ALL MECHANICAL EQUIPMENT AS CALLED FOR
IN THE SPECIFICATIONS. IF NOT SPECIFIED, AS RECOMMENDED BY MANUFACTURER FOR
QUIET OPERATION (WITH 99% ISOLATION EFFICIENCY).
6. PROVIDE A MIN. OF 10' CLEARANCE BETWEEN 0/A INTAKES AND VTR OR EXHAUST
OPENINGS.
7. INDEPENDENT CONTRACTOR SHALL TEST AND BALANCE ALL MECHANICAL EQUIPMENT
AIR DEVICES. EXTRACTORS. DAMPERS. AHU'S & FAN RATES. ETC. TO PROVIDE THE
DESIGN QUANTITIES AS SHOWN ON THE PLANS OR SCHEDULES. PROVIDE T & B
REPORT IN ACCORDANCE WITH THE AIR BALANCE COUNCIL STANDARDS. PROVIDE FINAL
BALANCING FOR ALL SYSTEMS TO SATISFACTION OF OWNER AND ENGINEER. T & B
CONTRACTOR SHALL VISIT JOB SITE DURING CONSTRUCTION TO ENSURE THAT ALL
DUCTS. DAMPERS. ETC. ARE INSTALLED FOR PROPER AND QUIET AIR DELIVERY.
8. THERMOSTAT LOCATION SHALL BE APPROVED BY OWNER AND ENGINEER BEFORE
INSTALLATION.
9. RUN INSULATED CONDENSATE DRAINS AS PER PLUMBING DRAWINGS.
10. NOT USED.
11. ALL PIPING AND DUCTWORK SHALL BE SLEEVED THRU WALLS, BEAMS, SLABS, ETC, AS
REQUIRED AND COORDINATED WITH THE STRUCTURAL ENGINEER. REWORK BAR JOIST
CROSS BRACING AND PROVIDE NECESSARY TRANSITIONS AS REQUIRED FOR DUCTWORK
INSTALLATION.
12. ALL INSULATION WILL HAVE FIRE /SMOKE RATING LESS THAN 25/50.
13. PROVIDE MOTOR STARTERS AS FOLLOWS (UNLESS OTHERWISE RECOMMENDED BY
MOTOR MANUFACTURER):
A: PROVIDE OVERLOAD PROTECTION - 1/3 HP AND ABOVE (ALL PHASES).
B: PROVIDE ACROSS THE LINE VOLTAGE STARTING BELOW 25 HP.
14. ALL OUTDOOR EQUIPMENT SHALL COMPLY WITH LOCAL ZONING NOISE ORDINANCES.
MIN. REQUIREMENT SHALL NOT EXCEED A NOISE LEVEL OF 65 DB AS MEASURED
RADIALLY 30 FT FROM THE EQUIPMENT IN ALL DIRECTIONS.
15. FILTERS SHALL BE IN PLACE DURING CONSTRUCTION. PROVIDE A NEW SET PRIOR TO
TEST AND BALANCE AND A FINAL SET AT THE END OF ONE YEAR SERVICE PERIOD.
r''
MECHANICAL INDEX
YES
DRWI r
DUCT SMOKE DETECTOR
�
i
1
MIA MECHANICAL INDEX. SYMBOL LEGEND AND NOTES.
SMOKE DAMPERS)
2
M1.2 MECHANICAL SCHEDULES
•
FIRE RATED ROOF/ FLOOR CEILING
ASSEMBLY
3
M2.1 FIRST FLOOR PLAN NEW CONSTRUCTION MECHANICAL PLAN
FIRE STOPPING
•
4
M2.2 SECOND FLOOR PLAN NEW CONSTRUCTION MECHANICAL PLAN
•
5
M2.3 THIRD FLOOR PLAN NEW CONSTRUCTION MECHANICAL PLAN
a
M2.4 FOURTH FLOOR PLAN NEW CONSTRUCTION ' MECHAMCAL PLAN
7
M2.5 ROOF LEVEL PLAN NEW CONSTRUCTION MECHANICAL PLAN
a
M3.1 PARTIAL FIRST FLOOR NEW CONSTRUCTION MECHANICAL PLAN
9
M3.2 PARTIAL FIRST FLOOR NEW CONSTRUCTION MECHANICAL PLAN
10
M3.3 PARTIAL FOURTH FLOOR ENLARGED MECHANICAL PLAN
11
M4.1 MECHANICAL CONTROLS PLAN 1
12
M4.2 MECHANICAL CONTROLS PLAN 2
13
M5.1 MECHANICAL DETAILS PLAN 1
14
M5.2 MECHANICAL. DETAILS PLAN 2
15
M5.3 MECHANICAL DETAILS PLAN 3
COORDINATION NOTES:
1. A/C CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE HIS WORK
FOR SIZE, LOCATION, CLEARANCE, ACCESS AND ELECTRICAL
CHARACTERISTICS WITH ALL OTHER TRADES AND TO PROVIDE SHOP
DRAWINGS TO THE ENGINEER FOR REVIEW BEFORE INSTALLATION OF
DUCTWORK OR EQUIPMENT. SHOP DRAWING WILL INCLUDE BEAM OR
STRUCTURE ELEVATION & REQUIRED EQUIPMENT ACCESS AREAS.
2. WALL, ROOF, AND CEILING OPENINGS INDICATED ON CONTRACTOR
DRAWINGS ARE NOMINAL DIMENSIONS ONLY AND ALL DUCT, PIPE
OR EQUIPMENT PENETRATIONS SHALL BE SLEEVED AND FIRE
RATED AS REQUIRED, ADJUST OPENINGS
3. COORDINATE LOCATION OF CEILING DIFFUSERS, GRILLES AND
REGISTERS IN THE FIELD WITH LIGHTS, SPRINKLERS AND
ARCHITECTURAL ELEMENTS.
4. COORDINATE LOCATION OF A/C UNITS, THERMOSTATS, FANS AND
DUCTWORK WITH BUILDING STRUCTURE AND OTHER TRADES SO
THAT NO INTERFERENCES OCCUR.
5. IN GENERAL, DUCT OFFSETS HAVE NOT BEEN SHOWN. A/C
CONTRACTOR TO COORDINATE THESE AS REQUIRED.
6. MECHANICAL PLANS IN GENERAL, ARE DIAGRAMMATIC IN NATURE, AND
ARE TO BE READ IN CONJUNCTION WITH ARCH. PLUMBING, ELECTRICAL
AND STRUCTURAL PLANS AND SHALL BE CONSIDERED AS ONE SET OF
DOCUMENTS. DUCT AND PIPING OFFSETS, BENDS AND TRANSITIONS WILL
BE REQUIRED TO PROVIDE AND INSTALL A COMPLETE FUNCTIONAL
SYSTEM AND SHALL BE PROVIDED BY THE CONTRACTOR AT NO
ADDITIONAL COST TO THE OWNER.
7. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO
BIDDING, ORDERING, FABRICATION OR INSTALLATION OF MATERIALS OR
EQUIPMENT.
CONTROLS:
1. TEST AND ADJUST SUPPLY AND RETURN AIR TEMPERATURES TO BE
WITHIN 5% OF DESIGN REQUIREMENTS +/- 2 T.
NOTES TO CONTRACTOR
DRAWINGS /DETAILS ARE TO BE CONSIDERED DIAGRAMMATIC. NOT NECESSARILY
SHOWING IN DETAIL OR TO SCALE ALL MINOR ITEMS.
UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE STRUCTURAL, ARCHITECTURAL
AND SITE CONDITIONS SHALL GOVERN EXACT LOCATIONS.
CONTRACTOR SHALL FOLLOW DRAWINGS IN LAYING OUT WORK. AND CHECK/
COORDINATE DRAWINGS OF ALL TRADES.
PLENUM NOTE
ALL MATERIALS WITHIN R/A PLENUMS SHALL BE NON - COMBUSTIBLE AND COMPLY
WITH ALL THE REQUIREMENTS OF FMC- 602.2.1.
HVAC DESIGN REQUIRES
YES
NO
DUCT SMOKE DETECTOR
•
i
FIRE DAMPERS)
•
SMOKE DAMPERS)
•
FIRE RATED ENCLOSURE
•
FIRE RATED ROOF/ FLOOR CEILING
ASSEMBLY
•
FIRE STOPPING
•
SMOKE CONTROL
•
a
Sf
0
Design Services
For The Built
Environment
N
Atlanta Birmingham
Cincinnati
Columbus Dallas
Fort Lauderdale
Knoxville Jackson
Jacksonville Louisville
Memphis Nashville
Richmond Tampa
■
G R E S H A M
S M I T H A N D
P A R T N E R S
6030 Hollywood Blvd.
Suite 210
Hollywood, Florida 33024
954.981.9100
FIRM'S FLORIDA
CERT. NO.
AAP000034 /CA3806
1B26000797/LC26000381
;\ENGINE RS
707 N.E:.'W A cV
FORT.'J.tY P1!hI>ALE, F 33 04% :.
(954) -111 O
CA #0 91 1 •:
- -- ` - -- --
PJT. MGR: MICHAEL HO
PROJECT #: 120717
CIL
i.'� �_ w
w
� o
% U) -
mc m 4o
t\ w
r� U) Q
L
Q �_
X ``) �
LLJ o
GEORGE SANJUAN, P.E.
FLORIDA LICENSE #46100
DATE: 02/01/13
REVISION
No. - Date - Revision
Q02/01/13
i Addendum #1
i
i
MECHANICAL INDEX,
SYMBOL LEGEND
AND NOTES
M1.1
FILE:
PROJECT: 29080.00
DATE: 1 1 /29/201 2