Loading...
13-718-006H . V. A. C. GENERAL NOTES: 1. THE WORK THAT IS TO BE DONE UNDER THIS HEADING INCLUDES THE FURNISHING OF ALL LABOR, MATERIALS, EQUIPMENT, PERMITS, FEES INSPECTIONS, TESTS, INSURANCE, ETC, REQUIRED FOR THE COMPLETION OF THE AIR CONDITIONING SYSTEM SHOWN ON THE DRAWINGS AND/ OR LISTED BEL ❑W, 2. VENTILATION DUCTWORK SHALL BE GALVANIZED STEEL WITH GAUGES, DUCT CONSTRUCTION, BRACING AND SUSPENSION IN ACCORDANCE WITH THE REC❑MMENDATI ❑NS SET FORTH IN THE LATEST EDITION OF THE A,S,H,R,A,E, GUIDE AND S,M,A.C,N,A, STANDARDS, DUCT SIZES SHOWN ARE "INSIDE' DIMENSI ❑NS, VERIFY EXACT LOCATION OF DUCT WITH RESPECT TO STRUCTURE BEFORE FABRICATI ❑N, 3. FLEXIBLE DUCT SHALL BE STEEL HELIX WIRE ON 7/8" CENTERS, ENCAPSULATED IN A CONTINUOUS SOFT VINYL FILM, JOINED BY MOLECULAR WELDING TO FORM AN AIR TIGHT INNER CORE, THE CORE IS TO BE INSULATED WITH FIBERGLASS INSULATION (R -6), AND SHEATHED IN A REINFORCED, ALUMINUM METALIZED POLYESTER VAPOR BARRIER JACKET, PROVIDE SPIN COLLAR WITH DAMPER AND EXTRACTOR WHERE FLEXIBLE DUCT IS CONNECTED TO RECTANGULAR DUCTWORK, DAMPER ACTUATOR SHALL BE EXTENDED OUTSIDE INSULATION, 4, AIR CONDITIONING SUPPLY AND RETURN DUCTWORK SHALL BE 1 -1/2" (R =6 MIN,) FIBERGLASS U,L. 181 LISTED, CLASS I AIR DUCT, DUCTWORK SHALL BE FABRICATED IN ACCORDANCE WITH S,M,A,C,N,A, STANDARDS, (R -6 TOP LEVEL, R -42 IN OTHER LEVELS), 5. TEMPERATURE CONTROL SHALL BE A ROOM THERMOSTAT FOR HEATING / CO ❑LING WITH STAGES AS REQUIRED, 6. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AV ❑ID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTI ❑N AND IN STRICT COMPLIANCE WITH ALL APPLICABLE CODES AND STANDARDS, 7, MECHANICAL CONTRACTOR SHALL VERIFY DIRECTION OF EXISTING STRUCTURE BEFORE INSTALLATION OF EQUIPMENTS AND DUCTWORK SHOULD ANY DISCREPANCIES BE FOUND CONTACT ARCHITECT /ENGINEER 8 VIBRATI ❑N ISOLATION., ALL EQUIPMENT AS PER MANUFACTURER REC ❑MMENDATI ❑NS TO ELIMINATE ANY EQUIPMENT NOISE FROM BEING HEARD, 9, GUARANTEES: A. ALL COMPRESSOR MOTORS ON NEW EQUIPMENT FURNISHED UNDER THIS CONTRACT SHALL HAVE A 5 YEARS PRODUCT GUARANTEE FROM DATE OF START -UP, B. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN A 1 YEAR FROM DATE OF ACCEPTANCE, 10, TESTING: A. ALL REFRIGERANT HIGH SIDE PIPING TO 300 PSIG, LOW SIDE TO 150 PSIG. AFTER TESTING, EVACUATE SYSTEM TO 28% MERCURY GAUGE PRESSURE WITH VACUUM PUMP, HOLD FOR 25 HOURS WITH PUMP OFF, BREAK VACUUM WITH REFRIGERANT, B. BALANCE AIR SYSTEM TO DELIVER QUANTITIES AT EACH OUTLET WITHIN 57. USING A.A,B,C, PROCEDURES AND TESTS, SUBMIT AIR BALANCE TEST RESULTS FOR APPROVAL PRIOR TO FINAL INSPECTION, 11. REFRIGERATION SUCTI ❑N PIPING SHALL BE INSULATED WITH 3 1/4 INC❑AFLEX ARMAFLEX INSULATION MAY ONLY BE USED IN NON- PLENUM AREAS, FINISHED WHERE EXPOSED WITH 2 COATS OF WHITE LATEX PAINT ALL A PER MANUFACTURER'S INSTRUCTION, 12, ALL REFRIGERANT PIPING SHALL BE TYPE "K" HARD COPPER, TOGETHER WITH WROUGHT COPPER SOLDER FITTINGS, JOINTS SHALL BE MADE WITH SILVER SOLDER OR "SILFOS ', ALL CONDENSATE DRAIN PIPING TO BE SCHEDULE 40 TYPE II HIGH IMPACT PVC WITH SLIP JOINT FITTING OF THE THE SAME MATERIAL WITH AN APPROVED SOLVENT INSTALLED IN A MANNER RECOMMENDED BY THE FITTING MANUFACTURER, HVAC DESIGN REQUIRES YES NO DUCT SMOKE DETECTOR MODEL NUMBER V/ FIRE DAMPER z V/ SMOKE DETECTOR Q ✓ FIRE RATED ENCLOSURE �- ✓ FIRE REATED ROOF CELING ASSEMBLY OCEILING B ✓ FIRE STOPPING FAN SPEED RPM ✓ SMOKE CONTROL o ✓ A/C EQUIPMENT SCHEDULE SYMBOL UNIT NUMBER AHU— 1 MODEL NUMBER AREA SERVED SEE FLR, PLAN z TOTAL SUPPLY AIR CFM 1350 Q OUTSIDE AIR CFM — �- EXTERNAL STATIC PRESS, Hz❑ 0.35 OCEILING B FAN MOTOR HP /FLA 1/3 /8.3 FAN SPEED RPM ELEC, CHAR, V /Z /ti 208/230/1/60 o COOL, COIL CAP, BTU /HR 40000 TOTAL STATIC PRESS, H2O 0.25 0.25 OPENING REQUIRED IN. TOTAL SENS, HEAT BTU /HR 28550 Lo 65 WATTS 135 WATTS J ENT, AIR TEMP, F' DB /° F WB 80/67 MANUFACTURER MODEL NUMBER CFM — MODEL NUMBER UNIT MANUFACTURER RHEEM NOTES: MODEL NUMBER RHSL— HM4221 2, ALL AIR DISTRIBUTI ❑N DEVICES SHALL BE OF EXTRUDED ALUMINUM CONSTRUCTI ❑N, FURNISH WITH OPPOSED BLADE DAMPERS AND CONCEALED MOUNTING FRAME Q WEIGHT LBS. 51 "X21 "X22/190 a ° REMARKS; REF, PIPING RS /RL 7/8" U UNIT NUMBER CU -1 0 J O M m LOCATI ❑N SEE FLR, PLAN z AMBIENT TEMP, OF 95 z REFRIGERANT R R — 410A A z COMP, /C ❑ND, FAN FLA 17.9 / 2,8 ° ELEC, CHAR, V /,O /ti 208/230/1/60 w MANUFACTURER RHEEM cm 0 M ❑DEL NUMBER RAPM- 042JEZ Lj WEIGHT LBS, 4 "X32 "X45 " /25 � REMARKS SEER/NOTES 14.5 z UNIT MTD, ELEC, HEAT CAP, KW 8.0 KW STEPS OF ELEC, HEAT NO, 1 ELEC, CHAR, V /,B /ti 208/1/60 MODEL NUMBER NOTE: INSTALL AHU -1 WITH PROGRAMMABLE THERMOSTAT, AIR DISTRIBUTION SCHEDULE SYMBOL NECK SIZE MFGR, MODEL NUMBER REMARKS O SEE FLR, TITUS OR CEILING DIFFUSER S/A REG, EXH, PLAN EQUAL SERIES 250 CEILING OCEILING B DIRECT DIRECT FAN SPEED RPM 1200 OR WALL RETURN 50F R/A GR, 100 200 TOTAL STATIC PRESS, H2O 0.25 0.25 OPENING REQUIRED IN. - - FAN MOTOR HP 65 WATTS 135 WATTS ELECTRICAL CHAR. V /9 /ti 115/1/60 115/l/60 MANUFACTURER Al LOREN COOK MODEL NUMBER GC,240 GC,340 NOTES: 1, REFER TO PLAN FOR QUANTITY, L ❑CATION AIR THROW PATTERN AND SIZES, 2, ALL AIR DISTRIBUTI ❑N DEVICES SHALL BE OF EXTRUDED ALUMINUM CONSTRUCTI ❑N, FURNISH WITH OPPOSED BLADE DAMPERS AND CONCEALED MOUNTING FRAME FOR ACOUSTICAL OR PLASTER CEILING INSTALLATI ❑N, FAN SCHEDULE UNIT NUMBER EF.1 & 2 EF -3 AREA SERVED TOILET ROOM GARAGE L ❑CATION CEILING CEILING DUTY SUPPLY /EXH, EXH, EXH, FAN TYPE CEILING CEILING DRIVE BELT /DIRECT DIRECT DIRECT FAN SPEED RPM 1200 1610 AIR QUANTITY CFM 100 200 TOTAL STATIC PRESS, H2O 0.25 0.25 OPENING REQUIRED IN. - - FAN MOTOR HP 65 WATTS 135 WATTS ELECTRICAL CHAR. V /9 /ti 115/1/60 115/l/60 MANUFACTURER L❑REN COOK LOREN COOK MODEL NUMBER GC,240 GC,340 WEIGHT LBS, 25 30 REMARKS S❑NES 1,5 4.3 NOTES: 1- INSTALL EF -1 INTERLOCK WITH LIGHT FIXTURE, 2- INSTALL EF -2 WITH CARBON MONOXIDE SENSOR, REVISIONS Nib. i THESE DRAWING do SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF RUBEN JUAN PUJOLWNETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED OR NOT, THEY ARE NOT TO BEUSED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH THE APPROPRIATE COMPENSATION TO RUBEN JUAN PUJOL do ASSOCIATES �/ Q CL w C� W C� LL Q I- LJ LLJ O r- — o Cn N _ w0-) I- °o Oy a Lo 0 V) F_ Q z = a o LLI z J tr W Q o U o cr J 00 L0 N ti 0 � M N CL � o CL zv W <w 9� Lg tLo � w W M co N ap Z _ =° o _ F- � a ° co W U � N > 0 J O M m ¢ v, L w D �QQ Q M T� Q O a DATE 04/04/2013 DRAWN BY: GPC CHECKED BY: R.P. SCALE: AS SHOW M -1 SHEET 6 OF 7