Loading...
13-718-005ELECTRICAL NOTES 1. PROVIDE EXPANSION JOINTS FITTINGS TO CONDUITS CROSSING STRUCTURAL EXPANSION JOINTS. 2. PROVIDE FULL WIRES IN TELEPHONE AND ALL EMPTY CONDUIT SYSTEMS. 3. ALL CONDUCTORS SHALL BE COOPER. 4. ALL CONTROL WIRES AND CONNECTIONS REQUIRED FOR AIR CONDITIONED AND VENTILATING EQUIPMENT OPERATION SHALL BE PROVIDED. REFER TO MECHANICAL DRAWING. 5. ALL 120 VOLTS BRANCH CIRCUIT RUNS EXCEEDING 100 FT. TO FIRST OUTLET SHALL BE MINIMUM # 10, UNLESS OTHERWISE INDICATED. 6. DO NOT DESTROY THE FIRE RATING OF WALLS BY CUTTING INTO THEM TO RUN CONDUITS OR INSTALL OUTLETS. USE ALTERNATE ROUTING IF NECESSARY. 7. MAINTAIN 12" MINIMUM SEPARATION BETWEEN OUTLET BOXES ON OPPOSITE SIDES OF SOUND INSULATED AND PARTY WALLS. 8. LOCATION OF OUTLETS IN ELECTRICIAN DRAWINGS IS DIAGRAMMATIC CHECK ARQUITECTURAL DRAWINGS FOR EXACT LOCATION OF OUTLETS. ADJUST OUTLETS LOCATION TO AVOID INTERFERENCE WITH OTHER TRADES. ALL OUTSIDE OULETS & DISCONNECTS SHALL BE NEMA 3R W/P 9. LOCATION OF SWITCHES VARIES WITH THE DOOR SWING: FOLLOW ARCHITECTURAL DRAWINGS IN EACH CASE. 10.ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLT, SINGLE PHASE, 15 AND 20 AMP. OUTLETS INSTALLED IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT INTERRUPTER LISTED TO PROVIDE PROTECTION OF THE ENTIRE BRANCH CIRCUIT F.E.M.A. NOTES. 1. ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW BASE FLOOD ELEVATION SHALL BE INSTALLED AT THE HIGHEST PERMITTED ELEVATION AND SHALL BE INSTALLED (SEPARATE) INDEPENDENT CIRCUITS FROM THOSE CIRCUITS IN THE HABITABLE AREAS. 2. NO APPLIANCES OR APPLIANCE OUTLETS SHALL BE INSTALLED BELOW BASE FLOOD ELEVATION. 3, A/C COMPRESSORS SHALL BE INSTALLED ABOVE BASE FLOOD ELEVATION 4. MAIN CIRCUIT BREAKER PANELS SHALL BE LOCATED ABOVE BASE FLOOD ELEVATION. 5. IT IS SUGGESTED THAT YOU CONFER WITH FLORIDA POWER AND LIGHT TO LOCATE THE ELECTRICAL METER TO COMPLY WITH FEDERAL EMERGENCY MANAGEMENT AGENCY REQUIREMENTS. NOTE: ALL SMOKE DETECTORS SHALL BE INTERLOCKED FOR ALARM ACTIVATION. ALL SMOKE DETECTORS MUST BE INTERCONECTED SO ALL DETECTORS SOUND WHEN ANY DETECTOR IS ACTIVATED. SMOKE DETECTOR 120 V. SWITCH LINE SIDE joF SWITCH SWITCH LEG. PHASE CONDUCTOR 11. CLAIMS FOR EXTRA WORK DUE TO MEET CODE REQUIREMENTS WILL NOT BE CONSIDERED. 12. GENERAL CONTRACTOR TO CONFORM WITH F.P.L. COMPANY TRANSFORMER PAD CONSTRUCTION SPECIFICATIONS IF TRANSFORMER PAD IS SPECIFIED ON PLANS. 13. AMONG ELECTRICAL CONTRACTORS RESPONSIBILITIES THERE SHALL BE: 13.1 - TO VERIFY ACTUAL FIELD CONDITIONS PRIOR BIDDING. ONCE THE AMOUNT OF WORK INVOLVED HAS BEEN DETERMINED, THE CON fRACrno SHALL INCLUDE IN HIS BID ALL NECESSARY PARTS AND LABOR REQ TO COMPLETE A SAFE AND CORRECT ELECTRICAL INSTALLATION. 13.2 - TO PROVIDE ADEQUATE WIRING, BREAKER OR SWITCH PROTEi CONFORM WITH FURNISHED EQUIPMENT WITH OUT EXTRA COST TO TI OWNER. 13.3 - TO CONTACT F.P.L. COMPANY'S REPRESENTATIVE TO DETERM FINAL UNDERGROUND PRIMARY CONDUITS ROUTING AND TO INSTALL AS PER F.P.L. COMPANY'S STANDARDS. 13.4 TO CONTACT AT & TS REPRESENTATIVE TO DETERMINE FINAL UNDERGROUND CONDUITS FOR TELEPHONE SUPPLY AND TO INSTALL AS PER THE COMPANY'S STANDARDS. 13.5 TO VERIFY EXISTING UTILITIES FACILITIES PRIOR TRENCHING. 13.6 TO COORDINATE, PRIOR CONSTRUCTION, WHAT AIR CONDITION CONTRACTOR AND MECHANICAL SHOP DRAWINGS, THE POINTS OF CONNECTIONS OF A/C UNITS AND LOCATIONS OF THEIR. ELECTRICAL NOTE: ALL HOUSE WILL HAVE SMOKE DETECTOR INSIDE AND OUTSIDE OF ALL SLEEPING AREAS -SMOKE DETECTOR TO BE CONNECT AT BEDROOMS ARC -FAULT CIRCUIT BRANCH AS PER 210.12 NEC AND 406.11 NEC ARC FAULT FOR ALL NEW AREAS AND TAMPER PROOF - VERIFY EXACT LOCATIONS OF ALL NEW ELECTRICAL FIXTURES, RECEP. AND J -BOXES WITH ARCHITECT IN FIELD PRIOR TO INSTALLATION ELECTRICAL LEGEND ....... 800 WATTS SINGLE POLE SWITCH 3W THREE -WAY SINGLE POLE SWITCH HEATER ....... DUPLEX RECEPTACLE GFl GFI OUTLET F0 WALL INCANDESCENT LIGHT. 0 CEILING INCANDESCENT LIGHT. F ;g�; MOTOR (EXHAUST FAN) D ELECTRICAL PANEL gFLOOD LIGHT EXISTING AIR ELECTRICAL SERVICE Y OTHERS 2# 2/0 THWN CU. IN 2" COND EXISTING ELECT. ETER 200 AMP. O EXIST. ELECTRICAL DISSCC. 2 AMP. 200 AMP GROUND - 1 # 1/0 CU IN 1/2" COND. TO CWP .,GROUND RODS & FOUNDATION REINF. 2 -5/8" D x 10' -0" LONG GROUND RODS EXISTING ELECTRICAL RISER DIAGRAM- N.T.S. ELECTRICAL NOTE: -ALL NEW 120 V, 15 A AND 20 A RECEPTACLES SHALL BE LISTED TAMPER - RESISTANT PER NEC 406.11 ELECTRICAL LOAD CALCULATION_ A- GRAL. LIGHTING LOAD 2399 SQ.F. 03W /SQ.F. =7197 WATTS B- 2 SMALL APPLIANCE CIRCUITS 1500 x 2 ....... 3000 WATTS FIXED APPLIANCES DISPOSAL ....... 800 WATTS WASHER .........1500 WATTS DRYER ......... 5000 WATTS HEATER ....... 11'800 WATTS RANGE ....... 12000 WATTS REFRIG . ....... 1000 WATTS POOL PUMP ........... 1500 WATTS DISHWASHER........... 1200 WATTS GARAGE DOOR ..........850 WATTS WATER PUMP......... 1500 BATH (GFI) ....... 600 WATTS WP (GFI) ....... 600 WATTS SPRINKLERS PUMP.......... 1500 WATTS C- CONNECTED LOAD LESS A /C= ......50'047 WATTS 10'000 WATTS 0 100% = 10'000 WATTS REST WATTS 0 40% =.... 16'018 WATTS A/C (or heating) 0 100% = 10'000 WATTS DEMAND LOAD 36'018/ 240 WATTS = 150 AMP.® 240/120V EXIST. SERVICE SIZE 200 AMP ELECTRICAL PANEL SCHEDULE CIRC. BKR WIRE VOLT DESCRIP. LOAD CIRC. BKR WIRE VOLT DESCRIP. LOAD 1 20 12 120 WATER PUMP. 1500 2/4/6/8/10/12 20 12 120 GRAL. LT. /RECEPT. + 3 20 12 120 GRAL. LT. /RECEPT. * 14/16 30 10 240 DRYER 5000 5 20 12 120 WASHER 1500 18/20 20 12 120 GRAL. LT. /RECEPT. z 7 20 12 120 GRAL. LT. /RECEPT. * 22 20 12 120 DISHWASHER 1200 9/11 60 6 240 A.H.U. 10'000 24 20 12 120 WP G.F.I. 600 13 20 12 120 BATH (GFI) 600 26/28 40 8 240 CU 5200 15/17 50 8 240 RANGE 12000 30 20 12 120 REFRIGERATOR 1000 19/21 20 12 240 POOL PUMP. 1500 32 20 12 120 GARB.DISP. 800 23/25 60 6 240 W.H. 11'800 34 20 12 120 GARAGE DOOR 850 27/29 20 12 120 SMALL APPL. 3000 36/38 20 12 240 SPRINKLERS PUMP. 1500 31 20 12 120 DISPOSAL 800 SPARE TOTAL W /OUT AIR CONDITION TOTAL W /OUT AIR CONDITION - REVISIONS ao. THESE DRAWING & SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF RUBEN JUAN PUJOLWHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED OR NOT, THEY ARE NOT TO BEUSED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH THE APPROPRIATE COMPENSATION TO RUBEN JUAN PUJOL & ASSOCIATES Q n W L1J Li- LJ LLJ 0 f— Lei 00 :2 CIO vi = N r- Ld O 6i Q Ln 0 U) z = F OL a U) o Lv z J Of w Q o U DATE 04/04/2013 DRAWN BY. GPC CHECKED BY: R.P. SCALE: AS SHOW E -1 SHEET 5 OF 7 00 LO N ti O .9J a r. o < P DATE 04/04/2013 DRAWN BY. GPC CHECKED BY: R.P. SCALE: AS SHOW E -1 SHEET 5 OF 7 00 LO N ti O M N LO o 1� CO v z V w Q W 9ti T- D L I— � W M M N ob z =° o I- �� Q o LO Lu U N 0 O m Q U) W Q Q c) � Q O a ¢ DATE 04/04/2013 DRAWN BY. GPC CHECKED BY: R.P. SCALE: AS SHOW E -1 SHEET 5 OF 7