13-718-005ELECTRICAL NOTES
1. PROVIDE EXPANSION JOINTS FITTINGS TO CONDUITS CROSSING
STRUCTURAL EXPANSION JOINTS.
2. PROVIDE FULL WIRES IN TELEPHONE AND ALL EMPTY CONDUIT SYSTEMS.
3. ALL CONDUCTORS SHALL BE COOPER.
4. ALL CONTROL WIRES AND CONNECTIONS REQUIRED FOR AIR CONDITIONED
AND VENTILATING EQUIPMENT OPERATION SHALL BE PROVIDED. REFER TO
MECHANICAL DRAWING.
5. ALL 120 VOLTS BRANCH CIRCUIT RUNS EXCEEDING 100 FT. TO FIRST
OUTLET SHALL BE MINIMUM # 10, UNLESS OTHERWISE INDICATED.
6. DO NOT DESTROY THE FIRE RATING OF WALLS BY CUTTING INTO THEM TO
RUN CONDUITS OR INSTALL OUTLETS. USE ALTERNATE ROUTING IF
NECESSARY.
7. MAINTAIN 12" MINIMUM SEPARATION BETWEEN OUTLET BOXES ON
OPPOSITE SIDES OF SOUND INSULATED AND PARTY WALLS.
8. LOCATION OF OUTLETS IN ELECTRICIAN DRAWINGS IS DIAGRAMMATIC
CHECK ARQUITECTURAL DRAWINGS FOR EXACT LOCATION OF OUTLETS.
ADJUST OUTLETS LOCATION TO AVOID INTERFERENCE WITH OTHER TRADES.
ALL OUTSIDE OULETS & DISCONNECTS SHALL BE NEMA 3R W/P
9. LOCATION OF SWITCHES VARIES WITH THE DOOR SWING:
FOLLOW ARCHITECTURAL DRAWINGS IN EACH CASE.
10.ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLT, SINGLE PHASE, 15 AND
20 AMP. OUTLETS INSTALLED IN DWELLING UNIT BEDROOMS SHALL BE
PROTECTED BY AN ARC -FAULT INTERRUPTER LISTED TO PROVIDE
PROTECTION OF THE ENTIRE BRANCH CIRCUIT
F.E.M.A. NOTES.
1. ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW BASE FLOOD ELEVATION
SHALL BE INSTALLED AT THE HIGHEST PERMITTED ELEVATION AND SHALL BE INSTALLED
(SEPARATE) INDEPENDENT CIRCUITS FROM THOSE CIRCUITS IN THE HABITABLE AREAS.
2. NO APPLIANCES OR APPLIANCE OUTLETS SHALL BE INSTALLED BELOW BASE FLOOD ELEVATION.
3, A/C COMPRESSORS SHALL BE INSTALLED ABOVE BASE FLOOD ELEVATION
4. MAIN CIRCUIT BREAKER PANELS SHALL BE LOCATED ABOVE BASE FLOOD ELEVATION.
5. IT IS SUGGESTED THAT YOU CONFER WITH FLORIDA POWER AND LIGHT TO LOCATE THE ELECTRICAL
METER TO COMPLY WITH FEDERAL EMERGENCY MANAGEMENT AGENCY REQUIREMENTS.
NOTE: ALL SMOKE DETECTORS SHALL BE
INTERLOCKED FOR ALARM ACTIVATION. ALL
SMOKE DETECTORS MUST BE
INTERCONECTED SO ALL DETECTORS SOUND
WHEN ANY DETECTOR IS ACTIVATED.
SMOKE DETECTOR
120 V.
SWITCH LINE SIDE
joF SWITCH
SWITCH LEG.
PHASE CONDUCTOR
11. CLAIMS FOR EXTRA WORK DUE TO MEET CODE REQUIREMENTS WILL NOT
BE CONSIDERED.
12. GENERAL CONTRACTOR TO CONFORM WITH F.P.L. COMPANY
TRANSFORMER PAD CONSTRUCTION SPECIFICATIONS IF TRANSFORMER PAD IS
SPECIFIED ON PLANS.
13. AMONG ELECTRICAL CONTRACTORS RESPONSIBILITIES THERE SHALL BE:
13.1 - TO VERIFY ACTUAL FIELD CONDITIONS PRIOR BIDDING. ONCE THE
AMOUNT OF WORK INVOLVED HAS BEEN DETERMINED, THE CON fRACrno
SHALL INCLUDE IN HIS BID ALL NECESSARY PARTS AND LABOR REQ
TO COMPLETE A SAFE AND CORRECT ELECTRICAL INSTALLATION.
13.2 - TO PROVIDE ADEQUATE WIRING, BREAKER OR SWITCH PROTEi
CONFORM WITH FURNISHED EQUIPMENT WITH OUT EXTRA COST TO TI
OWNER.
13.3 - TO CONTACT F.P.L. COMPANY'S REPRESENTATIVE TO DETERM
FINAL UNDERGROUND PRIMARY CONDUITS ROUTING AND TO INSTALL
AS PER F.P.L. COMPANY'S STANDARDS.
13.4 TO CONTACT AT & TS REPRESENTATIVE TO DETERMINE FINAL
UNDERGROUND CONDUITS FOR TELEPHONE SUPPLY AND TO INSTALL
AS PER THE COMPANY'S STANDARDS.
13.5 TO VERIFY EXISTING UTILITIES FACILITIES PRIOR TRENCHING.
13.6 TO COORDINATE, PRIOR CONSTRUCTION, WHAT AIR CONDITION
CONTRACTOR AND MECHANICAL SHOP DRAWINGS, THE POINTS OF
CONNECTIONS OF A/C UNITS AND LOCATIONS OF THEIR.
ELECTRICAL NOTE:
ALL HOUSE WILL HAVE SMOKE DETECTOR INSIDE AND
OUTSIDE OF ALL SLEEPING AREAS
-SMOKE DETECTOR TO BE CONNECT AT BEDROOMS
ARC -FAULT CIRCUIT BRANCH
AS PER 210.12 NEC AND 406.11 NEC
ARC FAULT FOR ALL NEW AREAS AND TAMPER PROOF
- VERIFY EXACT LOCATIONS OF ALL NEW ELECTRICAL
FIXTURES, RECEP. AND J -BOXES WITH ARCHITECT IN
FIELD PRIOR TO INSTALLATION
ELECTRICAL LEGEND
....... 800 WATTS
SINGLE POLE SWITCH
3W
THREE -WAY SINGLE POLE SWITCH
HEATER .......
DUPLEX RECEPTACLE
GFl
GFI OUTLET
F0
WALL INCANDESCENT LIGHT.
0
CEILING INCANDESCENT LIGHT.
F ;g�;
MOTOR (EXHAUST FAN)
D
ELECTRICAL PANEL
gFLOOD
LIGHT
EXISTING AIR ELECTRICAL SERVICE
Y OTHERS
2# 2/0 THWN CU.
IN 2" COND
EXISTING ELECT. ETER
200 AMP.
O EXIST.
ELECTRICAL
DISSCC. 2 AMP. 200 AMP
GROUND - 1 # 1/0 CU IN 1/2"
COND. TO CWP .,GROUND
RODS & FOUNDATION REINF.
2 -5/8" D x 10' -0" LONG
GROUND RODS
EXISTING ELECTRICAL RISER DIAGRAM-
N.T.S.
ELECTRICAL NOTE:
-ALL NEW 120 V, 15 A AND 20 A RECEPTACLES SHALL BE
LISTED TAMPER - RESISTANT PER NEC 406.11
ELECTRICAL LOAD CALCULATION_
A- GRAL. LIGHTING LOAD 2399 SQ.F. 03W /SQ.F. =7197 WATTS
B- 2 SMALL APPLIANCE CIRCUITS 1500 x 2 ....... 3000 WATTS
FIXED APPLIANCES DISPOSAL
....... 800 WATTS
WASHER .........1500
WATTS
DRYER ......... 5000 WATTS
HEATER .......
11'800 WATTS
RANGE ....... 12000 WATTS
REFRIG . .......
1000 WATTS
POOL PUMP ...........
1500 WATTS
DISHWASHER...........
1200 WATTS
GARAGE DOOR ..........850 WATTS
WATER PUMP.........
1500
BATH (GFI) .......
600 WATTS
WP (GFI) .......
600 WATTS
SPRINKLERS PUMP.......... 1500 WATTS
C- CONNECTED LOAD LESS A /C= ......50'047 WATTS
10'000 WATTS 0 100% = 10'000 WATTS
REST WATTS 0 40% =.... 16'018 WATTS
A/C (or heating) 0 100% = 10'000 WATTS
DEMAND LOAD 36'018/ 240 WATTS = 150 AMP.® 240/120V
EXIST. SERVICE SIZE 200 AMP
ELECTRICAL PANEL SCHEDULE
CIRC.
BKR
WIRE
VOLT
DESCRIP.
LOAD
CIRC.
BKR
WIRE
VOLT
DESCRIP.
LOAD
1
20
12
120
WATER PUMP.
1500
2/4/6/8/10/12
20
12
120
GRAL. LT. /RECEPT.
+
3
20
12
120
GRAL. LT. /RECEPT.
*
14/16
30
10
240
DRYER
5000
5
20
12
120
WASHER
1500
18/20
20
12
120
GRAL. LT. /RECEPT.
z
7
20
12
120
GRAL. LT. /RECEPT.
*
22
20
12
120
DISHWASHER
1200
9/11
60
6
240
A.H.U.
10'000
24
20
12
120
WP G.F.I.
600
13
20
12
120
BATH (GFI)
600
26/28
40
8
240
CU
5200
15/17
50
8
240
RANGE
12000
30
20
12
120
REFRIGERATOR
1000
19/21
20
12
240
POOL PUMP.
1500
32
20
12
120
GARB.DISP.
800
23/25
60
6
240
W.H.
11'800
34
20
12
120
GARAGE DOOR
850
27/29
20
12
120
SMALL APPL.
3000
36/38
20
12
240
SPRINKLERS PUMP.
1500
31
20
12
120
DISPOSAL
800
SPARE
TOTAL W /OUT AIR CONDITION
TOTAL W /OUT AIR CONDITION -
REVISIONS
ao.
THESE DRAWING & SPECIFICATIONS
ARE INSTRUMENTS OF SERVICE AND
SHALL REMAIN THE PROPERTY OF
RUBEN JUAN PUJOLWHETHER THE PROJECT
FOR WHICH THEY WERE PREPARED
IS EXECUTED OR NOT, THEY ARE NOT
TO BEUSED IN ANY MANNER ON OTHER
PROJECTS OR EXTENSIONS TO THIS
PROJECT EXCEPT BY AGREEMENT IN
WRITING AND WITH THE APPROPRIATE
COMPENSATION TO RUBEN JUAN PUJOL
& ASSOCIATES
Q
n
W
L1J
Li-
LJ
LLJ
0
f— Lei
00 :2
CIO
vi =
N r-
Ld
O 6i
Q Ln 0
U)
z =
F OL
a
U)
o
Lv
z J
Of
w Q
o U
DATE 04/04/2013
DRAWN BY. GPC
CHECKED BY: R.P.
SCALE: AS SHOW
E -1
SHEET 5 OF 7
00
LO
N
ti
O
.9J
a
r.
o
<
P
DATE 04/04/2013
DRAWN BY. GPC
CHECKED BY: R.P.
SCALE: AS SHOW
E -1
SHEET 5 OF 7
00
LO
N
ti
O
M
N
LO
o
1�
CO
v
z
V
w
Q
W
9ti
T-
D
L
I—
�
W
M
M
N
ob
z
=°
o
I-
��
Q
o
LO
Lu
U
N
0
O
m
Q
U)
W
Q
Q
c)
�
Q
O
a
¢
DATE 04/04/2013
DRAWN BY. GPC
CHECKED BY: R.P.
SCALE: AS SHOW
E -1
SHEET 5 OF 7