10-338-019SPLIT AC UNIT SCHEDULE UNIT DESIGNATION AHU -2 PROGRAMMABLE. AREA SERVED SEE PLANS PROVIDED LOCATION A/C CLOSET ACCESSORIES OPERATING WEIGHT, LBS 143 SUPPLY DESIGN MANUFACTURER RHEEM TITUS MODEL NUMBER RBHM17J11 DIFFUSER SEER / MIN. 16.1 8" SA RETURN TOTAL AIR, CFM 800 TITUS 317 z VENT AIR, CFM 0 o EXTERNAL STATIC PRESSURE, IN OF WATER 0.5 WALL GRILLE FAN MOTOR HP. (NON - OVERLOAD) 1/3 AIR z ELECTRICAL SERVICE AVAILABLE 230/l/60 NOTE: ALL AIR DISTRIBUTION SHALL BE FINISHED WHITE BAKED ENAMEL. MIN. CIRC. AMP 4 MAX. CIRC. PROT. 15 FACE VELOCITY - FPM - -- J DESIGN AIR ACROSS COIL, CFM. 800 ® GRAN TOTAL CAPACITY, BTU /HR 25,000 TOTAL SENSIBLE CAPACITY, BTU /HR 17,600 ENTERING AIR TEMP., F° DB /WB 80/67 COIL MODEL NO. RCQD2417A TYPE & THICKNESS CLEANABLE 1" QUANTITY AND SIZE 1/16X20 FACE VELOCITY FPM. MAX. n' HEAT COIL TYPE ELECT. LU ELECTRICAL SERVICE AVAILABLE 230/1/60 AUXILIARY ELECTRIC HEAT, KW 4.9 = STAGES & KW PER STAGE 1/4. UNIT DESIGNATION CU -2 z TYPE OF FAN PROP. NO. OF FANS AND AMPS 1/0.8 z AMBIENT AIR TEMP. 'F DB 95 Cn CONDENSING TEMP. 'F DB - -- Z w NO. OF COMPRESSORS TYPE 1 /SCROLL Z COMPRESSORS F.L.A. /L.R.A. EACH 10.3/52 o CAPACITY REDUCTION. 0 -50% -100% °w MIN. CIRC. AMP 14 -' MAX. CIRC. PROT. 20 oELECTRICAL SERVICE AVAILABLE 230/l/60 OPERATING WEIGHT, LBS 200 �c DESIGN MANUFACTURER RHEEM MODEL NUMBER RARL024JEZ REFRIGERANT PIPE SIZE, SUCTION /LIQUID 3/4" - 5/16" NOTES: 1. ALL THERMOSTATS SHALL BE PROGRAMMABLE. 2. FAN COIL UNIT SHALL BE PROVIDED WITH FACTORY INSTALLED CIRCUIT BREAKER. AIR DISTRIBUTION SCHEDULE 1" WIDE HANGER 72 GA �VD MANUAL VOLUME DAMPER MFG` & SYM50L USE TYPE ACCESSORIES MODEL NO. /��\ SUPPLY CEILING O.B.D. TITUS `-�' AIR DIFFUSER WITH DUCT SEALER & 250 -AA 8" SA RETURN CEILING O.B.D. TITUS 317 O AIR GRILLE SUPPLY AIR SUPPLY WALL GRILLE AIR O.B.D, TITUS 350E NOTE: ALL AIR DISTRIBUTION SHALL BE FINISHED WHITE BAKED ENAMEL. PROVIDE SWITCH IN UNIT OVERFLOW OUTLET WIRED TO SHUT DOWN UNIT WHEN WATER IS SENSED 2 "X 2 "X 1/2" NEOPRENE NEOPRENE PADS AT ALL CORNERS 2" x 2" x 1/4 STEEL ANGLE FRAME SHALL BE RUST PRIME PAINTED. 3X3X3/16" STEEL ANGLE PLATE. PROVIDE 4 CLEAR ALL AROUND UNIT -� PROVIDE 3' -0" CLEAR IN FRONT OF FC UNIT AHU AND HEATER. 20" MIN. VERTICAL AHU MOUNTING DETAIL 1. GENERAL A. ALL WORK SHALL BE DONE in accordance with the Florida Building Code and with all applicable regulations. B. DRAWINGS: Refer to all drawings for coordination of the HVAC work. C. ARRANGE AND PAY for all permits licenses, inspections and tests. Obtain the required certificates and present to owner. D. GUARANTEE: The completed installation shall be fully guaranteed against defective materials and /or improper workmanship for a minimum of one year for material and labor. All compressors shall be guaranteed for 5 years minimum. 2. SHOP DRAWINGS: Contractors shall submit for approval, within 30 days after signing contract, a minimum of five copies of fully descriptive literature, including but not limited to: fans, air conditioning units, air outlets. No work shall proceed without approval of these submittals. 3. DESIGN PARAMETERS: A. Indoor design temperature (Summer): 78 °F DB B. Indoor design temperature (Winter): 70'17 DB 4. ALL THERMOSTATS SHALL hove heating mode maximum setting of 75 F, and cooling made minimum setting of 70 F. The thermostat shall be arranged to prevent the simultaneous operation of heating and cooling. 5. ELECTRICAL CONTROLS AND POWER WIRING: Under electrical contract. 6. EQUIPMENT SPECIFIED BY manufacturer's number shall include all accessories, controls, etc., listed in the catalog as standard with the equipment. Optional or additional accessories shall be furnished as specified. 7. MATERIALS: A. REFRIGERANT PIPING: Shall be type L soft drawn, copper tubing, dehydrated for refrigerant use. Sized as shown on drawings or as per air conditioning equipment manufacturer's recommendations. B. INSULATION: Refrigerant suction piping shall be insulated with 1/2" thick foamed plastic insulation, fire retardant type. Insulation shall be installed in piping before assembly. No split insulation will be acceptable. Seal joints with manufacturer's approved adhesive and grey tape. C. DUCTWORK: a. All supply air ductwork shall be 1 1/2" thick fiberglass ductboard, fabricated and installed as per latest edition of SMACNA "Fibrous Glass Duct Manual ". R -6.0 MIN. b. All toilet exhaust ductwork shall be galvanized sheet metal duct not lighter than 24 gage. C. All duct dimensions are clear inside dimensions. d. Flexible insulated ductwork with 1 1/2" thick fiberglass insulation with FRK vapor barrier. R -6.0 MIN. 8. CONTROLS: Air conditioning units shall be started and stopped thru individual thermostat. Individual programmable thermostats shall start /stop supply fans and activate cooling /heating systems as selected. 9. TEF -1 50 CFM at .1" TSP 1.5 sones max. Broan 670, provide BDD and service switch. 55 Watts at 120V -1 -60. 10, TEST AND BALANCE: Contractor shall test and balance all ventilation and air conditioning systems. Submit four copies of Test and Balance Report, to owner for approval. DUCTWORK SYMBOLS HVAC_ SCHEDULES & DETA L S SCALE: N.T.S. IK I \ - -- --------------------- �. -------- - - - - -- i- - - - -- - _ -� ----------------- - - - - -- -- \ - - - - -- i, - -- - l I { I ........ -. .......... ...... _ - ------ .. _ ----- 18X6 L_. 400 CFM w - -, _. \ - - ---- - ,r -� �- i 1. 10n�I - \ \, ---------- - ---- - - - - - -- - - -- _ ---------------------- / Uc H o i Q�,i ►��Q►�lO�Pi�i�l�l�1 � I' ;w ! �l � l���l�l�l�l�l�l��0�1�01�1�1t1�� 12X12 �— -0--- 0 _6X6 A. nru 0 4 HVAC KEY NOTES 1O REF. PIPES UP IN WALL AND TO CEILING AND FAN COIL UNITS CONDENSING UNIT ON 4" CONCRETE PAD, 3 4 "0 TOILET EXHAUST, 6 "0 DUCT UP TO ROOF JACK W /WMS. ® 20X10 R/A DUCT DOWN TO FULL SIZE RETURN AIR PLENUM THERMOSTAT ® 3/4" SCHEDULE 40 PVC CONDENSATE DRAIN PIPE ABOVE GROUND, RUN TO DRYWELL OR GRASSY AREA, 2" UNDERGROUND TO GOOSENECK. SEPARATE MIN 12" FROM WALL PROVIDE "P" TRAP AT UNIT CONNECTION, INSULATE WITH 1/2" ARMAFLEX A.G. O FULL SIZE DISCHARGE PLENUM ® AIR DISTRIBUTION PLENUM. EXISTING AC DIFFUSERS & DUCTS IN THIS AREA TO REMAIN. RELOCATE AS NECESSARY, COORDINATE W/ ARCHITECT. HVAC PART AL PLAN- . SCALE. 4 -V-0" 1" WIDE HANGER 72 GA �VD MANUAL VOLUME DAMPER (� OR CFM CUBIC FEET PER MINUTE UC UNDERCUT DOOR DG -V DOOR GRILLE DL - -- p DOOR LOUVER (WITH VOLUME DAMPER AT AC CL.) DUCT. SUPPORT AT SUPPLY OR OUTSIDE AIR DUCT EVERY 5-0" (MAX.) TO AVOID SAG. RETURN OR EXHAUST AIR DUCT WITH DUCT SEALER & FLEXIBLE DUCT 8" SA LETTER [A] DENOTES AIR DISTRIBUTION DEVICE TYPE A 200 CFM NUMBER [8] DENOTES TERMINAL NECK SIZE BAND NUMBER [200] DENOTES SUPPLY AIR QUANTITY - -� - - -- RETURN AND EXHAUST AIR SUPPLY AIR To THERMOSTAT HVAC_ SCHEDULES & DETA L S SCALE: N.T.S. IK I \ - -- --------------------- �. -------- - - - - -- i- - - - -- - _ -� ----------------- - - - - -- -- \ - - - - -- i, - -- - l I { I ........ -. .......... ...... _ - ------ .. _ ----- 18X6 L_. 400 CFM w - -, _. \ - - ---- - ,r -� �- i 1. 10n�I - \ \, ---------- - ---- - - - - - -- - - -- _ ---------------------- / Uc H o i Q�,i ►��Q►�lO�Pi�i�l�l�1 � I' ;w ! �l � l���l�l�l�l�l�l��0�1�01�1�1t1�� 12X12 �— -0--- 0 _6X6 A. nru 0 4 HVAC KEY NOTES 1O REF. PIPES UP IN WALL AND TO CEILING AND FAN COIL UNITS CONDENSING UNIT ON 4" CONCRETE PAD, 3 4 "0 TOILET EXHAUST, 6 "0 DUCT UP TO ROOF JACK W /WMS. ® 20X10 R/A DUCT DOWN TO FULL SIZE RETURN AIR PLENUM THERMOSTAT ® 3/4" SCHEDULE 40 PVC CONDENSATE DRAIN PIPE ABOVE GROUND, RUN TO DRYWELL OR GRASSY AREA, 2" UNDERGROUND TO GOOSENECK. SEPARATE MIN 12" FROM WALL PROVIDE "P" TRAP AT UNIT CONNECTION, INSULATE WITH 1/2" ARMAFLEX A.G. O FULL SIZE DISCHARGE PLENUM ® AIR DISTRIBUTION PLENUM. EXISTING AC DIFFUSERS & DUCTS IN THIS AREA TO REMAIN. RELOCATE AS NECESSARY, COORDINATE W/ ARCHITECT. HVAC PART AL PLAN- . SCALE. 4 -V-0" INSULATED & VAPOR SEALED COLLAR & DIFFUSER BACK PANEL DIFFUSER AIR FLOW 2"X1.5 " - -22 GA. CHANNEL AT 6' -- -0" O.C. MAX. SEAL JOINT WITH DUCT SEALER & TAPE 1-✓ FLEXIBLE DUCT CONNECTION DETAIL N.T.S. TEF -1 �0 - - - -- TEF -1 1' -0" MIN. t<+ CU -2 CONDENSIP UNIT SECURED W/ 3) # 14 c INSERTS EACH FBC 301.13.1. PROVIDE 4" C POWER & CONTROL CONNECTIONS REFRIGERANT SUCTION & LIQUID LINES NOTES: 1. EQUIPMENT SHALL BE SECURED AS TO RESIST WIND PRESSURES IN FBC -2004 BUILDING. 2. EQUIPMENT SHALL BE MOUNTED ABOVE BASE FLOOD ELEVATION. 3. CONDENSING UNIT SECURED TO CONCRETE PAD TO WITHSTAND 500 Ib PULL OUT FORCE. a , LEQNARD0 NAVEIRAS, INC. 'CONSULTING ENGINEERS" • r O Leonardo Naveiras P.M. CA# 25830 z t_ Julio C. Vidal P.E. PE# 52792 :1P8 Harrison St. # 207 Hollywood, FL 33020 ........ ' 54 �' V'� 822 ax:- 954 2416650- — r'ITOTiC. J' E -mail: hvacleo @aol.com 131hr Caroline 7 i c L, A 1" WIDE HANGER 72 GA TO STRUCTURE ABOVE AS PER SMACNA STANDARDS. LOW VELOCITY SUPPLY AIR DUCT (SEE PLAN VIEW) INSULATED FLEXIBLE DUCT. SUPPORT AT EVERY 5-0" (MAX.) TO AVOID SAG. SEAL JOINT 1.5" WIDE STRAP SADDLE— WITH DUCT SEALER & SUPPORTED TO STRUCTURE TAPE ABOVE WITH 12 GA. HANGER WIRE. DRAW BAND AIR FLOW INSULATED & VAPOR SEALED COLLAR & DIFFUSER BACK PANEL DIFFUSER AIR FLOW 2"X1.5 " - -22 GA. CHANNEL AT 6' -- -0" O.C. MAX. SEAL JOINT WITH DUCT SEALER & TAPE 1-✓ FLEXIBLE DUCT CONNECTION DETAIL N.T.S. TEF -1 �0 - - - -- TEF -1 1' -0" MIN. t<+ CU -2 CONDENSIP UNIT SECURED W/ 3) # 14 c INSERTS EACH FBC 301.13.1. PROVIDE 4" C POWER & CONTROL CONNECTIONS REFRIGERANT SUCTION & LIQUID LINES NOTES: 1. EQUIPMENT SHALL BE SECURED AS TO RESIST WIND PRESSURES IN FBC -2004 BUILDING. 2. EQUIPMENT SHALL BE MOUNTED ABOVE BASE FLOOD ELEVATION. 3. CONDENSING UNIT SECURED TO CONCRETE PAD TO WITHSTAND 500 Ib PULL OUT FORCE. a , LEQNARD0 NAVEIRAS, INC. 'CONSULTING ENGINEERS" • r O Leonardo Naveiras P.M. CA# 25830 z t_ Julio C. Vidal P.E. PE# 52792 :1P8 Harrison St. # 207 Hollywood, FL 33020 ........ ' 54 �' V'� 822 ax:- 954 2416650- — r'ITOTiC. J' E -mail: hvacleo @aol.com 131hr Caroline 7 i c L, A