14-319-002SCALE: 1/4" = V-0" EXISTING FIRE SPRINKLER HEAD TO BE RELOCATED EXISTING FIRE SPRINKLER PIPE NEW SPRINKLER PIPE TOTAL NO. HEADS ON PROJECT = 9 STEEL I BEAM OR BAR JOIST 101 TOP BEAM CLAMP (w/lod( nut) HANGER ROD SIZES UP TO 4" PIPE: 3/8" DIA. BRANCH LINE i + 1 THREADED kNGER ROD SLAB 3/8" ROD_�- 3/8" POWDER COUPLING DRIVEN STUD ALL THREADED HANGER ROD NUT PIPE RING MAXIMUM HANGER SPACING (FT.) MAXIMUM HANGER SPACING (FT.) PIPE SIZE (IN.) 3/4 1 1 1/4 1 1/2 2 2 1/2 THREADED LIGHTWALL STEEL PIPE N/A 12 12 12 12 12 STEEL PIPE EXCEPT THREADED LIGHTWALL N/A 12 12 15 15 15 PIPE SUPPORT DETAIL 1 SIX Wt HEAD ADAPTER PENDENT F.S. HEAD JL ARM-OVER DETAIL OPTION ARMOVER FROM OUTLET NO SCALE ON TOP/ SIDE OR BOTTOM December 12,2013 Sprinkler lla The Viking Corporation, 210 N Industrial Park Drive, Hastings M149058 Telephone: 269-945-9501 Technical Services: 877-3846464 Fax: 269418-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Micrornab& and Mlcromaticl­[P� Standard Response Pendent Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several differ- MEE== ent finishes, temperature ratings, and K-Factors to meet design requirements. The special Polyester, Polytetrafluoroethylene (PTFE), and Electroless Nickel PTFE (ENT) coatings can be used In decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmos- pheres and are listedlapproved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approved the ENT coating as corrosion resistant FM Xi Global has no approval classification for PTFE and Polyester coatings as corrosion resistant) Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed) on deluge systems- Refer to Ordering Instructions on page 111b. 2. LISTINGS AND APPROVALS PN 12937 PN 10223 C& cULus Listed: Category VNIV <jj> FM Approved: Classes 2001, 2002, 2015; 2017, 2043 NYC Approved., MEA 89-92-E, Volume 12 ABS Certified: Certificate 04-+iS407984A-PDA VdS Approved: Certificate G4040096, 64040098, G4060058, 64060059, 64980001, 64980002, 64980005, and G4980007 LPC Approved: Ref- No. 096eM and 167a/04 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0786-CPD40181, 0832-CPD-2001, and 0832-GPD-2003 MED Certified, Standard EN 12259-1, EC-cerfifitste of conformity 0832-MED-1003 and 0832 MED-1008, and RINA Certificate No. MED497705C5 NOTE: Other International approval certificates are available upon request Refer to Approval Charts 1-3 and Design Criteria on pages lid-f for cULus Listing requirements, and referto Approval Charts 45 and Design Criteria on pages 119-h for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1997: Viking Technical Data may be found on Minimum Operating Pressure: 7 psi (0.5 bar)/ Maximum Working Pressure: Sprinklers VK023 and VK122 are rated for The Viking Corporation's Web site at use with water working pressures ranging from the minimum 7 psi httixilwww.vikinggroupmr-com. (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- The Web site may Include a more recent sure (HP) sprinklers can be Identified by locating "250" stamped on edition of this Technical Data Page. the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: Refer to the Approval Charts Nominal K-Factor- Refer to the Approval Charts Glass-bulb fluid temperature rated to -65 *F ( -55'C) Overall Length: Refer to the Approval Charts t cULus Listing, FM Appmval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Appmvals ONLY Is 5 psi (035 bar). Material Standards: Frame Casting: Brass UNS-084400 or QM Brass for Sprinkler 12987, Brass UNS-084400 for ail other sprinklers. Deflector, Phosphor Bronze UNS-051000tt or Copper UNS-0I9500 for Sprinklers 12987,10142,10170, 10173, and 10223. Brass UNS-C26000 for all other Sprinklers. Form No. F_l 00397 Replaces page I I a-j, dated June 28, 2013. (Added E-3 Escutcheon.) I&, D, r2 NOTE, COUPONS TO BE ATTACHED TO ALL NEW MECH TEES, SCHEDULE ARMOVERS GREATER THAN 1. NEW MECH-TYPE TEE. 24' IN LENGTH SHALL BE 2, EXISTING BRANCHLINE. OR MAIN SUPPORTED BY A HANGER. 3. ARMOVER.31 NEW CONNECTION DETAIL LIW-1 tqvu Worldwide File Phrteaion Contacts I wwwAyco-fire.com f lmducft I Seri" W-B, 5.6 K-factor Updght, Pendent and Recessed Pendent Sprinkfers Standard Response,, Standard Coverage General EMM The Series 7Y-B Sprinklers described De scrip tion herein must be Instailed and maintained in compliance mdh'this document, as The TYCO Series,TY-B, 5.6 K-factor, well as with the applicaUe standards Upright (TY315) and Pendent (TY325) of the AfatForyaf Fe Protection Asso cla- Sprinklers described In this data sheet tion, h7 addftr to the standards of any are standard response; standard cover- other authorities having jurisdiction. age, decorative 5 mm glass bulb type FWktre to do so may Impair the perfor- spray sprinklers designed for use in malice of these devices. light, ordinary, or extra hazard, com- mercial occupancies such as banks, The ownerls responsible, formaintain- hotels' shopping malls, factories, In their tire protection system and reonones, and Chemical plants devices In proper operating condition The recessed version of the Series TY-B Pendent Sprinkler, where appli- cable, is intended for use In areas with a finished ceiling, This recessed pendent sprinkler uses one of the following: • A two-piece Style 15 Recessed Escutc;heon with recessed adjust- ment up to 518 inch (15,9 mm) from the flush pendent position. • A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 Inch (12,7 mm) from the flush pendent posftn. The adjustmentl provided by the Recessed Escutcheon reduces the -accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-13 Sprinklers are described in Technical Data Sheet TFP352. Sprinkler guards and shields are described in Technical Data Sheet IMPORTANT Always refer to Technical Data Sheet'7P 700 for the "INSTALLER WARNING* that provides cau- tfons: with respect to handling and installation of sonihider systems and componefts. Impicr.- h&Wkr and Installation can-permanently dam- age a sprinkler system or its comp0- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. a­ - Page I of 4 The instaffing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identffication Numbers (SINs) TY315 — _.Upright 5.6K, 112'NPT TY326 ......Pendent 5.6K, 1/2-NPIT Technical Temperature Ratings Data .135-F (57-C) 15WF (68-C) Approvals 175 °F (79 °C) UL and C-UL Listed 200-F (93 °C) FM, LPCB, and VdS Approved 286-F (141-C), CE Certified 360'F(182-C)t Sprinklers with Polyester Finish are t UL, C-UL, and VdS Approved only UL and C-UL Listed as Corrosion- Resistant Sprinklers. Finishes Sprinkler. Refer to Table A Maximum Worldrig Pressure Recessed Escutcheon: White Coated, 175 psi (12.1 W Chrome Plated, or Brass Plated 250 psi (17.2 bar}• The maximum "110119 pr= ure of 250 psi Physical Characteristics Z (17.2 bar) only olas to listing by Un- Frame ......... __ ... Bronze derwrit,ws Laboratories, Inc. (UL). Button.:... . — . . . Brass/Copper Discharge Coefficient Sealing Assembly... i,.e. -.Stainless, , I wfrEFLON K = 5,6 GPM/psI92 (80,6 LPIM/bar12) Bulb .......... . . .........,.Glass Compress n rew Bronze Deflector, ....... .... Bronze FEBRUARY 2014 TFP152 GENERAL NOTES 1 -ALL PIPING, HEADS, HANGERS AND SYSTEM COMPONENTS TO BE SPACED AND INSTALLED AS PER THE LATEST APPLICABLE EDITION OF NFPA -13 (2007 EDITION), APPROVING AUTHORITY HAVING JURISDICTION AND ALL STATE AND LOCAL CODES. 2 - SPACING FOR FIRE SPRINKLER HEADS IN LIGHT HAZARD AREAS TO BE 225 SQ. FT. MAXIMUM PER HEAD, ORDINARY HAZARD AREAS TO BE 130 SQ. FT. MAXIMUM PER HEAD. 3 - PIPING TO BE INSTALLED CONCEALED ABOVE DROPPED CEILINGS EXCEPT AS NOTED IN EXPOSED CEILING AREAS. 4 - LINE PIPING 1"- 2" TO BE THREADED "XL" WITH SCREWED FITTINGS OR APPROVED EQUAL.. 5 - HEAD-GAURDS TO BE PROVIDED ON EXPOSED SPRINKLERS IN JANITOR CLOSETS. 6 - PROVIDE FIRE STOPPING ON ALL PENETRATIONS THROUGH FIRE WALLS. NFPA 13 - 2007 EDITION 24.2 ACCEPTANCE REQUIREMENTS. 24.2.1 - HYDROSTATIC TESTS. 24.2.1.1 - UNLESS PERMITTED BY 24.2.1.2 THROUGH 24.2.1.6, ALL PIPING AND ATTACHED APPURTENANCES SUBJECTED TO SYSTEM WORKING PRESSURE SHALL BE HYDROSTATICALLY TESTED AT 200 PSI (13.8 BAR) AND SHALL MAINTAIN THAT PRESSURE WITHOUT LOSS FOR 2 HOURS. 24.2.1.2 PORTIONS OF SYSTEMS NORMALLY SUBJECTED TO SYSTEM WORKING PRESSURES IN EXCESS OF 150 PSI (10.4 BAR) SHALL BE TESTED AS DESCRIBED IN 24.2.2.1 AT A PRESSURE OF 50 PSI (3.5 BAR) IN EXCESS OF SYSTEM WORKING PRESSURE. 24.2.1.3 WHERE COLD WEATHER WILL NOT PERMIT TESTING WITH WATER, AN INTERIM AIR TEST SHALL BE PERMITTED TO BE CONDUCTED AS DESCRIBED IN 24.2.3. 24.2.1.4 MODIFICATIONS AFFECTING 20 OR FEWER SPRINKLERS SHALL NOT REQUIRE TESTING IN EXCESS OF SYSTEM WORKING PRESSURE. 24.2.1.5 WHERE ADDITION OR MODIFICATION IS MADE TO AN EXISTING SYSTEM AFFECTING MORE THAN 20 SPRINKLERS, THE NEW PORTION SHALL BE ISOLATED AND TESTED AT NOT LESS THAN 200 PSI (13.8 BAR) FOR 2 HOURS. 24.2.1.6 MODIFICATIONS THAT CANNOT BE ISOLATED, SUCH AS RELOCATED DROPS, SHALL NOT REQUIRE TESTING IN EXCESS OF SYSTEM WORKING PRESSURE. 2009 FLORIDA STATUTES/ CHAPTER 6331 FIRE PREVENTION AND CONTROL PERSONS CERTIFIED AS A CONTRACTOR 1, CONTRACTOR 11, OR CONTRACTOR IV UNDER THIS CHAPTER MAY DESIGN FIRE PROTECTION SYSTEMS OF 49 OR FEWER SPRINKLERS, AND MAY DESIGN THE ALTERATION OF AN EXISTING FIRE SPRINKLER SYSTEM IF THE ALTERATION CONSISTS OF THE RELOCATION, ADDITION, OR DELETION OF NOT MORE THAN 49 SPRINKLERS, NOTWITHSTANDING THE SIZE OF THE EXISTING FIRE SPRINKLER SYSTEM. CONTRACTOR-DEVELOPED PLANS MAY NOT BE REQUIRED BY ANY LOCAL PERMITTING AUTHORITY TO BE SEALED BY A REGISTERED PROFESSIONAL ENGINEER. SCOPE OF WORK: EXISTING TENANT AREAS TO BE RENOVATED IN A FULLY PROTECTED BUILDING. RELOCATE AND ADD FIRE SPRINKLER HEADS AS SHOWN ON PLANS TO ACCOMMODATE CHANGES. lm� F H Z C3 0: 0 Z 01 Z M DESCRIPTION EXISTING PENDENT FIRE SPRINKLER HEAD O. 1/2- 165 DEG. TYCO STANDARD COV, STANDARD RESPONSE EXISTING PENDENT FIRE SPRINKLER HEAD TO REMAIN 165 DEG. VIKING STANDARD COV, STANDARD RESPONSE m lv l_ r ' ENT SPRINKLER HEAD 7 1/2" 155 DEG. VIKING MODEL TY-B (SIN TY-325) W c1r) T-SPRMLLiN HEAP = 2 < 1/2' 155 DEG. VIKING MICROMATIC (SIN VK-102) EXISTING FIRE SPRINKLER HEAD TO BE RELOCATED EXISTING FIRE SPRINKLER PIPE NEW SPRINKLER PIPE TOTAL NO. HEADS ON PROJECT = 9 STEEL I BEAM OR BAR JOIST 101 TOP BEAM CLAMP (w/lod( nut) HANGER ROD SIZES UP TO 4" PIPE: 3/8" DIA. BRANCH LINE i + 1 THREADED kNGER ROD SLAB 3/8" ROD_�- 3/8" POWDER COUPLING DRIVEN STUD ALL THREADED HANGER ROD NUT PIPE RING MAXIMUM HANGER SPACING (FT.) MAXIMUM HANGER SPACING (FT.) PIPE SIZE (IN.) 3/4 1 1 1/4 1 1/2 2 2 1/2 THREADED LIGHTWALL STEEL PIPE N/A 12 12 12 12 12 STEEL PIPE EXCEPT THREADED LIGHTWALL N/A 12 12 15 15 15 PIPE SUPPORT DETAIL 1 SIX Wt HEAD ADAPTER PENDENT F.S. HEAD JL ARM-OVER DETAIL OPTION ARMOVER FROM OUTLET NO SCALE ON TOP/ SIDE OR BOTTOM December 12,2013 Sprinkler lla The Viking Corporation, 210 N Industrial Park Drive, Hastings M149058 Telephone: 269-945-9501 Technical Services: 877-3846464 Fax: 269418-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Micrornab& and Mlcromaticl­[P� Standard Response Pendent Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several differ- MEE== ent finishes, temperature ratings, and K-Factors to meet design requirements. The special Polyester, Polytetrafluoroethylene (PTFE), and Electroless Nickel PTFE (ENT) coatings can be used In decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmos- pheres and are listedlapproved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approved the ENT coating as corrosion resistant FM Xi Global has no approval classification for PTFE and Polyester coatings as corrosion resistant) Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed) on deluge systems- Refer to Ordering Instructions on page 111b. 2. LISTINGS AND APPROVALS PN 12937 PN 10223 C& cULus Listed: Category VNIV <jj> FM Approved: Classes 2001, 2002, 2015; 2017, 2043 NYC Approved., MEA 89-92-E, Volume 12 ABS Certified: Certificate 04-+iS407984A-PDA VdS Approved: Certificate G4040096, 64040098, G4060058, 64060059, 64980001, 64980002, 64980005, and G4980007 LPC Approved: Ref- No. 096eM and 167a/04 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0786-CPD40181, 0832-CPD-2001, and 0832-GPD-2003 MED Certified, Standard EN 12259-1, EC-cerfifitste of conformity 0832-MED-1003 and 0832 MED-1008, and RINA Certificate No. MED497705C5 NOTE: Other International approval certificates are available upon request Refer to Approval Charts 1-3 and Design Criteria on pages lid-f for cULus Listing requirements, and referto Approval Charts 45 and Design Criteria on pages 119-h for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1997: Viking Technical Data may be found on Minimum Operating Pressure: 7 psi (0.5 bar)/ Maximum Working Pressure: Sprinklers VK023 and VK122 are rated for The Viking Corporation's Web site at use with water working pressures ranging from the minimum 7 psi httixilwww.vikinggroupmr-com. (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- The Web site may Include a more recent sure (HP) sprinklers can be Identified by locating "250" stamped on edition of this Technical Data Page. the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: Refer to the Approval Charts Nominal K-Factor- Refer to the Approval Charts Glass-bulb fluid temperature rated to -65 *F ( -55'C) Overall Length: Refer to the Approval Charts t cULus Listing, FM Appmval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Appmvals ONLY Is 5 psi (035 bar). Material Standards: Frame Casting: Brass UNS-084400 or QM Brass for Sprinkler 12987, Brass UNS-084400 for ail other sprinklers. Deflector, Phosphor Bronze UNS-051000tt or Copper UNS-0I9500 for Sprinklers 12987,10142,10170, 10173, and 10223. Brass UNS-C26000 for all other Sprinklers. Form No. F_l 00397 Replaces page I I a-j, dated June 28, 2013. (Added E-3 Escutcheon.) I&, D, r2 NOTE, COUPONS TO BE ATTACHED TO ALL NEW MECH TEES, SCHEDULE ARMOVERS GREATER THAN 1. NEW MECH-TYPE TEE. 24' IN LENGTH SHALL BE 2, EXISTING BRANCHLINE. OR MAIN SUPPORTED BY A HANGER. 3. ARMOVER.31 NEW CONNECTION DETAIL LIW-1 tqvu Worldwide File Phrteaion Contacts I wwwAyco-fire.com f lmducft I Seri" W-B, 5.6 K-factor Updght, Pendent and Recessed Pendent Sprinkfers Standard Response,, Standard Coverage General EMM The Series 7Y-B Sprinklers described De scrip tion herein must be Instailed and maintained in compliance mdh'this document, as The TYCO Series,TY-B, 5.6 K-factor, well as with the applicaUe standards Upright (TY315) and Pendent (TY325) of the AfatForyaf Fe Protection Asso cla- Sprinklers described In this data sheet tion, h7 addftr to the standards of any are standard response; standard cover- other authorities having jurisdiction. age, decorative 5 mm glass bulb type FWktre to do so may Impair the perfor- spray sprinklers designed for use in malice of these devices. light, ordinary, or extra hazard, com- mercial occupancies such as banks, The ownerls responsible, formaintain- hotels' shopping malls, factories, In their tire protection system and reonones, and Chemical plants devices In proper operating condition The recessed version of the Series TY-B Pendent Sprinkler, where appli- cable, is intended for use In areas with a finished ceiling, This recessed pendent sprinkler uses one of the following: • A two-piece Style 15 Recessed Escutc;heon with recessed adjust- ment up to 518 inch (15,9 mm) from the flush pendent position. • A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 Inch (12,7 mm) from the flush pendent posftn. The adjustmentl provided by the Recessed Escutcheon reduces the -accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-13 Sprinklers are described in Technical Data Sheet TFP352. Sprinkler guards and shields are described in Technical Data Sheet IMPORTANT Always refer to Technical Data Sheet'7P 700 for the "INSTALLER WARNING* that provides cau- tfons: with respect to handling and installation of sonihider systems and componefts. Impicr.- h&Wkr and Installation can-permanently dam- age a sprinkler system or its comp0- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. a­ - Page I of 4 The instaffing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identffication Numbers (SINs) TY315 — _.Upright 5.6K, 112'NPT TY326 ......Pendent 5.6K, 1/2-NPIT Technical Temperature Ratings Data .135-F (57-C) 15WF (68-C) Approvals 175 °F (79 °C) UL and C-UL Listed 200-F (93 °C) FM, LPCB, and VdS Approved 286-F (141-C), CE Certified 360'F(182-C)t Sprinklers with Polyester Finish are t UL, C-UL, and VdS Approved only UL and C-UL Listed as Corrosion- Resistant Sprinklers. Finishes Sprinkler. Refer to Table A Maximum Worldrig Pressure Recessed Escutcheon: White Coated, 175 psi (12.1 W Chrome Plated, or Brass Plated 250 psi (17.2 bar}• The maximum "110119 pr= ure of 250 psi Physical Characteristics Z (17.2 bar) only olas to listing by Un- Frame ......... __ ... Bronze derwrit,ws Laboratories, Inc. (UL). Button.:... . — . . . Brass/Copper Discharge Coefficient Sealing Assembly... i,.e. -.Stainless, , I wfrEFLON K = 5,6 GPM/psI92 (80,6 LPIM/bar12) Bulb .......... . . .........,.Glass Compress n rew Bronze Deflector, ....... .... Bronze FEBRUARY 2014 TFP152 GENERAL NOTES 1 -ALL PIPING, HEADS, HANGERS AND SYSTEM COMPONENTS TO BE SPACED AND INSTALLED AS PER THE LATEST APPLICABLE EDITION OF NFPA -13 (2007 EDITION), APPROVING AUTHORITY HAVING JURISDICTION AND ALL STATE AND LOCAL CODES. 2 - SPACING FOR FIRE SPRINKLER HEADS IN LIGHT HAZARD AREAS TO BE 225 SQ. FT. MAXIMUM PER HEAD, ORDINARY HAZARD AREAS TO BE 130 SQ. FT. MAXIMUM PER HEAD. 3 - PIPING TO BE INSTALLED CONCEALED ABOVE DROPPED CEILINGS EXCEPT AS NOTED IN EXPOSED CEILING AREAS. 4 - LINE PIPING 1"- 2" TO BE THREADED "XL" WITH SCREWED FITTINGS OR APPROVED EQUAL.. 5 - HEAD-GAURDS TO BE PROVIDED ON EXPOSED SPRINKLERS IN JANITOR CLOSETS. 6 - PROVIDE FIRE STOPPING ON ALL PENETRATIONS THROUGH FIRE WALLS. NFPA 13 - 2007 EDITION 24.2 ACCEPTANCE REQUIREMENTS. 24.2.1 - HYDROSTATIC TESTS. 24.2.1.1 - UNLESS PERMITTED BY 24.2.1.2 THROUGH 24.2.1.6, ALL PIPING AND ATTACHED APPURTENANCES SUBJECTED TO SYSTEM WORKING PRESSURE SHALL BE HYDROSTATICALLY TESTED AT 200 PSI (13.8 BAR) AND SHALL MAINTAIN THAT PRESSURE WITHOUT LOSS FOR 2 HOURS. 24.2.1.2 PORTIONS OF SYSTEMS NORMALLY SUBJECTED TO SYSTEM WORKING PRESSURES IN EXCESS OF 150 PSI (10.4 BAR) SHALL BE TESTED AS DESCRIBED IN 24.2.2.1 AT A PRESSURE OF 50 PSI (3.5 BAR) IN EXCESS OF SYSTEM WORKING PRESSURE. 24.2.1.3 WHERE COLD WEATHER WILL NOT PERMIT TESTING WITH WATER, AN INTERIM AIR TEST SHALL BE PERMITTED TO BE CONDUCTED AS DESCRIBED IN 24.2.3. 24.2.1.4 MODIFICATIONS AFFECTING 20 OR FEWER SPRINKLERS SHALL NOT REQUIRE TESTING IN EXCESS OF SYSTEM WORKING PRESSURE. 24.2.1.5 WHERE ADDITION OR MODIFICATION IS MADE TO AN EXISTING SYSTEM AFFECTING MORE THAN 20 SPRINKLERS, THE NEW PORTION SHALL BE ISOLATED AND TESTED AT NOT LESS THAN 200 PSI (13.8 BAR) FOR 2 HOURS. 24.2.1.6 MODIFICATIONS THAT CANNOT BE ISOLATED, SUCH AS RELOCATED DROPS, SHALL NOT REQUIRE TESTING IN EXCESS OF SYSTEM WORKING PRESSURE. 2009 FLORIDA STATUTES/ CHAPTER 6331 FIRE PREVENTION AND CONTROL PERSONS CERTIFIED AS A CONTRACTOR 1, CONTRACTOR 11, OR CONTRACTOR IV UNDER THIS CHAPTER MAY DESIGN FIRE PROTECTION SYSTEMS OF 49 OR FEWER SPRINKLERS, AND MAY DESIGN THE ALTERATION OF AN EXISTING FIRE SPRINKLER SYSTEM IF THE ALTERATION CONSISTS OF THE RELOCATION, ADDITION, OR DELETION OF NOT MORE THAN 49 SPRINKLERS, NOTWITHSTANDING THE SIZE OF THE EXISTING FIRE SPRINKLER SYSTEM. CONTRACTOR-DEVELOPED PLANS MAY NOT BE REQUIRED BY ANY LOCAL PERMITTING AUTHORITY TO BE SEALED BY A REGISTERED PROFESSIONAL ENGINEER. SCOPE OF WORK: EXISTING TENANT AREAS TO BE RENOVATED IN A FULLY PROTECTED BUILDING. RELOCATE AND ADD FIRE SPRINKLER HEADS AS SHOWN ON PLANS TO ACCOMMODATE CHANGES. lm� F H Z C3 0: 0 Z 01 Z M FP-1 OF I • 0 < c1r) • < • < 3: C0 -J W CY) < CL • W a 0, • W W > R • Lo -1 g cl) C) • U_ LL LL 0 Z F_ UJ co de • _J < Z • d • W W 0 1'*- OR F- - D 0 • 4 U W 0 • a. • FP-1 OF I • 4 • • • OUR FP-1 OF I