Loading...
14-1037-006TRUE rn MPG11 H PROPOSED GENERATOR PLUG POWER CONDUIT TO BE ROUTED VERTICALLY UP WALL AND PENETRATE CEILING TO FLOOR ABOVE PROPOSED 200A METER AND DISCONNECT. SEE E -1 FOR CONNECTION TO EXISTING LOAD CENTER P P P P P -� — P P P EXISTING ELECTRICAL EQUIPMENT (TYP) PENETRATE CMU WALL AS NEEDED (TYP) EXISTING TENANT (SEE DETAIL 6/C -4) METER (TYP) •o EXISTING MAIN SWITCH I BOARD LOAD CENTER CONDUITS TO ROUTE IN CEILING SPACE FASTEN TO CEILING PER DETAIL 7/C -4 EXISTING ELECTRICAL ROOM -0 \GROUND P FLOOR _ r— PROPOSED GEN AND POWER CONDUITS FROM EXISTING MECHANICAL ROOM TO MECHANICAL/TELPHONE EQUIPMENT ROOM. ROUTE CONDURS TIGHT TO CEILING (SEE DETAIL 7/C -4). COORDINATE ROUTING WITH LANDLORD IN PLENUM SPACE ABOVE EXISTING HARD CEILING IN LOBBY AREA. REUSE EXISTING SPARE CONDUITS IF AVAILABLE. GROUND LINE IN PVC CONDUIT TO TERMINATE AT WATER MAN (SW CORNER OF BUILDING) WITHIN W OF SERVICE ENTRANCE POINT (SEE DETAIL 9/E -3) 1 � r-------- - - - - -- ------- - - - - -� (�EXISTING I I 19 MECHANICAL/TELEPHONE (' \ EXISTING EQUIPMENT ROOM I ELEVATOR , EXISTING ..:.:. _.._ _. ' LOBBY i EXISTING ELEVATOR i EXISTING ELEVATOR i PROPOSED GEN AND POWER CONDUITS TO ROUTE VERTICALLY TO ROOF. CORE THROUGH EACH FLOOR AND DAYLIGHT INSIDE ELEVATOR PENTHOUSE AT ROOF LEVEL (SEE 1/C -1 FOR CONTINUATION) PENETRATE CMU WALL ABOVE PROPOSED CONDUITS TO BE EXISTING GENERATOR ON DOOR INTO ELECTRICAL ROOM ROUTED (SEE DETAIL 6/C -4) IN THIS AREA THE CEILING CONCRETE PAD i P P P P P P P P P P P P EXISTING 70' LONG SERVICE CORRIDO ;) - - - - - -- -- ------- - - - - -- -- -- - - - - -- PARKING GARAGE P P iI P P I C� C P o A � A A � P � I A -- ---- - - - - -� \ A a l O \\ I It \ P P P 5,_i., \ P P P —J EXISTING PUMPS ON CONCRETE PAD EXISTING PROPOSED CONDUITS TO BE MECHANICAL ROOMS ROUTED IN ENG THE CEILING PARTIAL GROUND FLOOR PLAN_ SCALE: 1" = 5' PENETRATE CMU WALL IN THIS AREA INTO SERVICE CORRIDOR (SEE DETAIL 6/C -4) PROPOSED 200A WALL MOUNTED ATS PROPOSED 200A WALL MOUNTED MTS EXISTING CMU PARTITION (TO BE REMOVED) PROPOSED 50kW DIESEL GENERATOR. SEE SHEET M -1 FOR GENERATOR SPECS AND MECHANICAL DETAILS PROPOSED POWER, ALARM, AND CONTROL CONDUITS ROUTED ALONG CEILING TO AND FROM GENERATOR AND RELATED EQUIPMENT (SEE ELECTRICAL SHEETS) EXISTING CONDENSING UNIT Sou-rw WplAl. ` 7 304l.DINO' ospT. sEC�10N StRUCT ORAL v�rr�e 777 YAMATO DRIVE, SUITE 600 BOCA RATON, FL 33431 • PLANNING • ENGINEERING • SURVEYING • CONSTRUCTION MANAGEMENT TECTONIC Engineering & Surveying Consultants P.C. 36 British American Blvd., Suite 101 Latham, NY 12110 Phone: (518) 783 -1630 Fax: (518) 783 -1544 Iwww.tectonicengineering.com I DESIGN APPROVAL PRELIMINARY /CONSTRUCTION 7/11/13 RF ENG. DATE: EQPT. ENG. DATE: OPERATIONS DATE: CONST. MGR. DATE: NETWORK ENG. DATE: REAL ESTATE DATE: WORK ORDER NUMBER DRAWN BY 6097.68304A TJH NO_ DATE ISSLIF 0 6/10/13 FOR COMMENT 1 7/11/13 PER COMMENTS 2 7/19/13 FOR PERMIT 3 9/3/13 FOR CONSTRUCTION 4 12/30/13 REVISED GENERATOR FOR CONSTRUCTION 5 3/17/14 REVISED EQUIPMENT FOR CONSTRUCTION RELEASED BY DATE p,pp00000000pp0 1:' e • i•: 9 e o o `.{{11� o • (I: a iTr s UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN BEARING THE SEAL OF A LICENSED ENGINEER OR LAND SURVEYOR IS A VIOLATION OF ACCEPTED ENGINEERING PRACTICES IN THE STATE OF FLORIDA PURSUANT TO SECTION 471 FLORIDA STATUTES. COPIES OF THIS DOCUMENT WITHOUT A FACSIMILE OF THE SIGNATURE AND AN ORIGINAL EMBOSSED SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR LAND SURVEYOR SHALL NOT BE CONSIDERED VALID COPIES. 0 1 2 3 ORIGINAL SIZE IN INCHES SUNSET STATION 5975 SUNSET DRIVE CITY OF SOUTH MIAMI MIAMI DADE COUNTY FL 33143 CONDUIT ROUTING & GENERATOR PLAN SHEET NUMBER C�5