14-1037-002TRUE
rn
MPGN�`c �
� W
N W
Z
Cn D
(n
SEE DETAIL 4/C -2
FOR GAMMA SECTOR
DETAIL PLAN
I
L —,_
sFcT
°1p
A
FACE OF BUILDING
EXISTING PARAPET
EXISTING PANEL
ANTENNA (TYP)
ROOFING NOTE
ALL ROOF WORK SHALL BE PERFORMED BY ABSOLUTE WATERPROOFING, INC. OF
HOLLYWOOD, FL
PAINTING NOTE
ALL ANTENNAS, MOUNTS, AND RELATED EQUIPMENT THAT IS VISIBLE FROM THE GROUND
SHALL BE PAINTED TO MATCH THE EXISTING BUILDING
A/C UNIT RELOCATION NOTE
WORK RELATED TO THE RELOCATION OF EXISTING A/C UNITS TO BE COMPLETED OUTSIDE
OF NORMAL BUSINESS HOURS TO AVOID INTERUPTION OF A/C SERVICE DURING
CONSTRUCTION.
EXISTING BUILDING
COLUMNS BELOW (TYP)
PROPOSED COAX TO BE MOUNTED ALONG
THE FACE OF THE PARAPET WALL
(SEE DETAIL 4/C -4)
L60 N Lon 1. 1 i3o moi
SW 59TH PL
SCALE: 1" = 10'
EXISTING FPL VAULT
AT GRADE
PROPOSED STEEL SUPPORT GIRDER
(SEE DETAIL S -1 FOR FRAME DETAILS)
SEE DETAIL 1/C -2 FOR
EQUIPMENT LAYOUT PLAN
PROPOSED UTILITY CONDUITS
ROUTED FROM PENTHOUSE TO
EQUIPMENT FRAME
(SEE DETAIL 3/C -4)
UTILITY CONDUITS TO PENETRATE
WALL AND TRANSITION TO PROPOSED
EQUIPMENT FRAME (SEE DETAIL 6/C -4
FOR WALL PENETRATION INFORMATION)
PROPOSED UTILITY CONDUITS TO ENTER CRAWL
SPACE BELOW PENTHOUSE FROM FLOOR BELOW.
CONDUITS SHALL ROUTE IN CRAWL SPACE AS
REQUIRED TO PROPOSED EQUIPMENT FRAME.
SEE SHEET C -5 AND C -6 FOR CONDUIT
ROUTING THROUGH BUILDING.
EXISTING BUILT -UP
ROOF PENTHOUSE
EXISTING
ROOFTOP A/C UNIT
SEE DETAIL 2/C -2
FOR ALPHA SECTOR
DETAIL PLAN
11 GENERAL NOTES
1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE FLORIDA STATE
BUILDING CODE, AND ALL OTHER APPLICABLE CODES AND ORDINANCES.
2. CONTRACTOR SHALL VISIT THE JOB SITE AND FAMILIARIZE HIMSELF WITH ALL
CONDITIONS AFFECTING THE PROPOSED WORK AND MAKE PROVISIONS AS TO THE
COST THEREOF. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF
WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS AND
CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO
PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE
ATTENTION OF THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK.
3. PLANS ARE NOT TO BE SCALED. THESE PLANS ARE INTENDED TO BE A
DIAGRAMMATIC OUTLINE ONLY, UNLESS OTHERWISE NOTED. THE WORK SHALL
INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR
NECESSARY TO EFFECT ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS.
4. DIMENSIONS SHOWN ARE TO FINISH SURFACES, UNLESS OTHERWISE NOTED. SPACING
BETWEEN EQUIPMENT IS REQUIRED CLEARANCE. THEREFORE, IT IS CRITICAL TO FIELD
VERIFY DIMENSIONS. SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT
DOCUMENTS, EXISTING CONDITIONS AND /OR DESIGN INTENT, THE CONTRACTOR SHALL
BE RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE CARRIER'S AUTHORIZED
REPRESENTATIVE OR THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK.
5. DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR MODIFICATIONS
MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH
MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK.
6. CONTRACTOR SHALL RECEIVE CLARIFICATION IN WRITING, AND SHALL RECEIVE IN
WRITING AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY ITEMS NOT
CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS.
7. CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER OF ALL PRODUCTS OR
ITEMS NOTED AS "EXISTING" WHICH ARE NOT FOUND TO BE IN THE FIELD.
8. CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING THE BEST
CONSTRUCTION SKILLS AND ATTENTION. CONTRACTOR SHALL BE SOLELY
RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES,
PROCEDURES, AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER
CONTRACT, UNLESS OTHERWISE NOTED.
9. ERECTION SHALL BE DONE IN A WORKMANLIKE MANNER BY COMPETENT
EXPERIENCED WORKMEN IN ACCORDANCE WITH APPLICABLE CODES AND THE BEST
ACCEPTED PRACTICE. ALL MEMBERS SHALL BE LAID PLUMB AND TRUE AS INDICATED
ON THE DRAWINGS.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE WORK AREA,
ADJACENT AREAS, AND BUILDING OCCUPANTS THAT ARE LIKELY TO BE AFFECTED BY
THE WORK UNDER THIS CONTRACT. WORK SHALL CONFORM TO ALL OSHA
REQUIREMENTS.
11. CONTRACTOR SHALL COORDINATE HIS WORK AND SCHEDULE HIS ACTIVITIES AND
WORKING HOURS IN ACCORDANCE WITH THE REQUIREMENTS OF THE OWNER.
12. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING HIS WORK WITH THE
WORK OF OTHERS AS IT MAY RELATE TO RADIO EQUIPMENT, ANTENNAS AND ANY
OTHER PORTIONS OF THE WORK.
13. CONTRACTOR SHALL MAINTAIN LIABILITY INSURANCE TO PROTECT THE OWNER AND
CARRIER.
14. INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS UNLESS SPECIFICALLY INDICATED OR WHERE LOCAL CODES OR
REGULATIONS TAKE PRECEDENCE.
15. MAKE NECESSARY PROVISIONS TO PROTECT EXISTING SURFACES, EQUIPMENT,
IMPROVEMENTS, PIPING, ANTENNA AND ANTENNA CABLES. REPAIR ANY DAMAGE THAT
OCCURS DURING CONSTRUCTION.
16. REPAIR ALL EXISTING SURFACES DAMAGED DURING CONSTRUCTION SUCH THAT THEY
MATCH AND BLEND WITH ADJACENT SURFACES.
17. KEEP CONTRACT AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DEBRIS AND
RUBBISH. EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY OF THE
OWNER SHALL BE REMOVED. LEAVE PREMISES IN CLEAN CONDITION AND FREE FROM
PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. CONTRACTOR SHALL BE
RESPONSIBLE FOR MAINTAINING ALL ITEMS UNTIL COMPLETION OF CONSTRUCTION.
18. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD PRIOR
TO FABRICATION AND ERECTION OF ANY MATERIAL. ANY UNUSUAL CONDITIONS SHALL
BE REPORTED TO THE ATTENTION OF THE ENGINEER.
19. CONTRACTOR SHALL SECURE ALL NECESSARY BUILDING PERMITS AND INSPECTIONS
AND PAY ALL REQUIRED FEES.
20. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2 -A
OR 2- A /10 -BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF THE
BUILDOUT AREA DURING CONSTRUCTION.
21. ALL BROCHURES, OPERATING AND MAINTENANCE MANUALS, CATALOGS, SHOP
DRAWINGS AND OTHER DOCUMENTATION SHALL BE TURNED OVER TO CARRIER AT
COMPLETION OF CONSTRUCTION.
22. COMPLETE JOB SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER
THE DATE OF ACCEPTANCE BY CARRIER. ANY WORK, MATERIALS, OR EQUIPMENT
FOUND TO BE DEFECTIVE DURING THAT PERIOD SHALL BE CORRECTED IMMEDIATELY
UPON WRITTEN NOTIFICATION AT NO ADDITIONAL COST TO CARRIER.
23. RIGGING OPERATIONS SHALL BE DONE IN ACCORDANCE WITH STATE AND FEDERAL
SAFETY REGULATIONS (OSHA). TECTONIC, CARRIER AND THE OWNER SHALL BE HELD
HARMLESS IN THE EVENT THE CONTRACTOR DOES NOT FOLLOW SUCH SAFETY
REGULATIONS.
24. CONTRACTOR SHALL PROVIDE ACCESS TO THE SITE AND ASSIST THE RADIO
EQUIPMENT VENDOR AND THE ANTENNA INSTALLATION CONTRACTOR AS THEY MAY
REQUIRE.
�,PMt
of So G ° P�
"'NZ Bv,�p�N SSC��pN
s�R���vRP(1 w n.
v ri,�o
-- - ----- - ---
777 YAMATO DRIVE, SUITE 600
BOCA RATON, FL 33431
• PLANNING
• ENGINEERING
• SURNING
• CONSTRUCTION
MANAGEMENT
TECTONIC Engineering & Surveying Consultants P.C.
36 British American Blvd., Suite 101
Latham, NY 12110
Phone: (518) 783 -1630
Fax: (518) 783 -1544
www.tectonicengineering.com
DESIGN APPROVAL
PRELIMINARY /CONSTRUCTION
RF ENG. DATE:
EQPT. ENG. DATE:
OPERATIONS DATE:
CONST. MGR. DATE:
NETWORK ENG. DATE:
REAL ESTATE DATE:
WORK ORDER NUMBER DRAWN BY
6097.68304A TJ H
Nn_ nATF ISSIIF
0
6/10/13
FOR COMMENT
1
7/11/13
PER COMMENTS
2
7/19/13
FOR PERMIT
3
9/3/13
FOR CONSTRUCTION
4
12/30/13
REVISED GENERATOR
FOR CONSTRUCTION
5
3/17/14
REVISED EQUIPMENT
FOR CONSTRUCTION
RELEASED BY DATE
"=;t A o ° N
o °
o °
O � O
O °
O °
d
O .Sr1 O y
n _ : Y
• C•
� Ca
O�} -
O fns Gs
UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN
BEARING THE SEAL OF A LICENSED ENGINEER OR LAND
SURVEYOR IS A VIOLATION OF ACCEPTED ENGINEERING
PRACTICES IN THE STATE OF FLORIDA PURSUANT TO
SECTION 471 FLORIDA STATUTES.
COPIES OF THIS DOCUMENT WITHOUT A FACSIMILE OF
THE SIGNATURE AND AN ORIGINAL EMBOSSED SEAL OR
ORIGINAL STAMP IN BLUE OR RED INK OF THE
PROFESSIONAL ENGINEER OR LAND SURVEYOR SHALL
NOT BE CONSIDERED VALID COPIES.
0 1 2 3
ORIGINAL SIZE IN INCHES
ti7114
SUNSET STATION
5975 SUNSET DRIVE
CITY OF SOUTH MIAMI
MIAMI DADE COUNTY
FL 33143
OOF & SITE PLAN
GENERAL NOTES
C -1