13-1357-001(TYP') r. ................ FIRE PROTECTION FLOOR PLAN M. PLAN NOTES O1 EXISTING SPRINKLER HEAD TO BE RELOCATED AND REPLACED BY NEW O EXISTING SPRINKLER HEAD TO BE CAPPED O3 NEW RECESSED SPRINKLER HEAD. SEE SCHEDULE IN THIS SHEET FOR MORE INFORMATION O NEW CONCEALED SPRINKLER HEAD. SEE SCHEDULE IN THIS SHEET FOR MORE INFORMATION .y�GENERAL NOTES ff =r: > "C,�: Phone: 786.223.4927 Fax: 305.254.0405 1. ALL PIPE LOCATIONS ARE TO BE FIELD MEASURED PRIOR FABRICATION AND INSTALLATION BY SPRINKLER CONTRACTOR. 11123 sw 128 pl Miami FL,33186 2. ALL DIMENSIONS SHOWN ARE CENTER TO CENTER. Florida State Certified 3. HIGH TEMPERATURE HEADS ARE TO BE FIELD LOCATED WHERE REQUIRED. "x Fire Protection Contractor 4. ALL PIPES AND HANGERS ARE TO BE INSTALLED PER NFPA #13. State License # : FPC12- 000053 5. HANGERS ARE TO BE U.L. LISTED AND F.M. APPROVED. Licensed & Insured www.erfire- engineering.com FIRE PROTECTION LEGEND smea oesceivnary eEK OR O(K - CONTROL VALVE W /TAMPER SWITCH N - CHECK VALVE 0-0 - FLOW SWITCH 'V FDC - FIRE DEPARTMENT CONNECTION om PIV - POST INDICATOR VALVE W /TAMPER SWITCH =FVC - FIRE VALVE CABINET 6W FDV - STANDPIPE WITH FIRE DEPARTMENT VALVE MAXIMUM COVERAGE /SPRINKLER HEAD: 225 SQ. FT. HOSE STREAM ALLOWANCE: - SPRINKLER AND DRAIN RISER {j- ELEV. OF TOP OF STEEL 0 - BACKFLOW PREVENTOR W /TAMPER SWITCHES 155' - ROOF MANIFOLD Q - HYDRAULIC REFERENCE NODE DS- 1/TY3230 - NEW SPRINKLER PIPING F.C. - FLUSHING CONNECTION 0 - EXISTING 1/2' CONCEALED SPRINKLER TO BE RELOACTED OR CAPPED O - EXISTING CONTROL VALVE W /TAMPER SWITCH 155' - EXISTING CHECK VALVE 0-0 - EXISTING FLOW SWITCH `2 FDC - EXISTING FIRE DEPARTMENT CONNECTION NONE - EXISTING SPRINKLER PIPING GENERAL CONTRACTOR: 00 PENNNAVEUCTION INC. PITTSBURGH, PA 15221 PHONE: 412- 243 -2483 FAX:412- 243 -7925 - EXISTING SPRINKLER PIPING TO BE REMOVED e-- - CONNECT TO EXISTING Q-- - DEMOLISH TO POINT INDICATED Q - REVISION REFERENCE e- DETAIL REFERENCE: TOP - DETAIL #, -T BOTTOM - DRAWING# SHOWN ON NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT DESIGN CRITERIA OFFICE SPACES- OCCUPANCY CLASSIFICATION: LIGHT HAZARD SYSTEM TYPE: WET PIPE DESIGN DENSITY: .10 GPM /SQ. FT. HYDRAULIC REMOTE AREA: 1,500 SQ. FT. SPRINKLER ORIFICE SIZE: 1/2" DURATION OF SUPPLY: 30 MIN. MAXIMUM COVERAGE /SPRINKLER HEAD: 225 SQ. FT. HOSE STREAM ALLOWANCE: 100 GPM DESIGN CRITERIA: THE FOLLOWING PUBLICATIONS SHALL BE USED AS A REFERENCE FOR INSTALLATION OF THE FIRE PROTECTION SYSTEM ON THIS PROJECT. 1. NEPA 13 2007 EDITION INSTALLATION OF SPRINKLER SYSTEMS 2. 2010 FLORIDA FIRE PREVENTION CODE ° d d d d l 4 ? ° 4 CONCRETE FASTENER (U.L USTED OR F.M. APPROVED) ALL THREAD ROD UVPIPE HANGER RING (U.L USTED OR F.M. APPROVED) HANGER - CONCRETE No Scale GENERAL NOTES 1. INSTALLATION IN ACCORDANCE WITH NFPA 13 (2007 EDITION)• THE FLORIDA FIRE PREVENTION CODE 2010 EDITION AND ALL LOCAL AND STATE A THORITIES. 2. ALL MATERIALS TO BE UL LISTED AND FM - APPROVED 3. SPRINKLERS MAINS 2Y" AND LARGER TO BE SCHEDULE 10 ASTM A -135 BLACK STEEL JOINED BY ROLLED GROOVED METHOD USING GROOVED FITTINGS AND COUPLINGS. 4. BRANCH LINES 2" AND SMALLER TO BE GALVANIZED LIGHT WALL THREADEDABLE XL PIPE CONFORMING TO ASTM A -135 UP TO 300 PSI WORKING PRESSURE 5. DRAIN LINE PIPING 2" AND SMALLER TO BE SCHEDULE 40 ASTM -A53 GALVANIZED STEEL PIPE 150 LBS GALVANIZED MALLEABLE IRON THREADED OUTLET FITTINGS. FOR DRY SYSTEMS. 6. DRAIN LINE PIPING 2" AND SMALLER TO BE SCHEDULE 40 ASTM -A53 GALVANIZED STEEL PIPE 300 LBS GALVANIZED DUCTILE IRON THREADED OUTLET FITTINGS. FOR WET PIPE SYSTEMS. 7. SPRINKLER MAINS AND GROOVED BRANCH LINES ( DRY SYSTEMS) 1Y" AND LARGER TO BE SCHEDULE 10 ASTM A- 1351795 GALVANIZED STEEL JOINED BY ROLL GROOVED METHOD USING PAINTED GROOVED FITTINGS & COUPLINGS. 8. DRY PIPE SYSTEMS AND EXTERIOR PIPING 1" AND SMALLER TO BE SCHEDULE 40 ASTM- AI35/795 GALVANIZED STEEL PIPE JOINED WITH 300 LB DUCTILE IRON FITTINGS WITH STANDARD FINISHED. 9. ALL DRY PIPE MAINS TO BE PITCHED AT Y" PER 10 FEET AND BRANCH LINES TO BE PITCHED Y2" IN 10 FEET FOR DRAINAGE. 10. +0' -0" = SPRINKLER PIPING CENTER LINE ELEVATION ABOVE FLOOR. 11. HANGERS TO BE SIZED AND SPACED IN ACCORDANCE WITH NFPA -13, SECTION 9.1 2010 EDITION. 12. HANGER RODS TO BE ZINC PLATED ALL THREADED. 13. ACCESS PANELS TO BE PROVIDED ABOVE ALL ACCESSIBLE CEILINGS AND CHASES. 14. FIRE SPRINKLERS TO BE INSTALLED UNDER ALL EXPOSED DUCTWORK OVER 48" WIDE. (SPRINKLER HEADS UNDER DUCTS ARE NOT INDICATED ON PLANS, BUT ARE REQUIRED AND SHALL BE PROVIDED IN ACCORDANCE TO NFPA -13. 15. SPRINKLER HEADS GUARDS ARE REQUIRED ON ALL SPRINKLER HEADS IN ELECTRICAL ROOMS TELEPHONE ROOMS, ELEVATOR ROOMS, ELEVATOR SHAFTS AND ANY SPRINKLERS BELOW 7' -0" AFF. 16. ALL INDICATING CONTROL VALVES TO BE PROVIDED WITH TAMPER SWITCHES. 17. UNDERGROUND SCOPE OF WORK TO COMMENCE AS INDICATED ON PLANS. 18. UNDERGROUND PIPING SHALL BE DR -14 C -900 PVC FOR PRESSURES EXCEEDING 150 PSI, CLASS 350 DUCTILE IRON PIPE SHALL BE IN VERTICAL RISERS AND AT PENETRATION POINT AT BUILDING FOUNDATION. 19. CHANGES IN DIRECTION OF PIPING TO BE MADE BY USE OF MECHANICAL JOINT FITTINGS. 20. THRUSTS RESTRAINS TO BE PROVIDED AT ALL TURNS AND ENDS OF MAIN PER NFPA -24 21. 200 LBS 0 2 HOURS PRESSURE TESTING AND FLUSHING TO BE PERFORMED PER NFPA -24 22. FLUSHING AND TESTING OF UNDERGROUND PIPING TO BE PERFORMED AS PER NFPA -24 23. WET BULK SUPPLY MAINS AND HOSE SUPPLY MAINS EXPOSED TO THE WEATHER SHALL BE INSULATED AND PROVIDED WITH AN ALUMINUM JACKET. 24. SPRINKLERS IN ELEVATOR SHAFTS AND EQUIPMENT ROOMS ARE TO BE INTERMEDIATE TEMPERATURE 2007 SPRINKLERS PER NFPA 13. 25. IF SYSTEM PRESSURE - EXCEEDS 100 PSI, ALL HANGERS ON-END HEADS IN PENDANT POSITION SHAL BE WITHIN 12" OF END OF LINE IN ACCORDANCE WITH NFPA 13 26. SPRINKLERS SHALL BE PROVIDED AT THE TOP AND BOTTOM OF ALL STAIRWELLS AND AT THE LANDING OF EACH FLOOR THAT OPENS INTO MORE THAN ONE FIRE ZONE. FIRE PROTECTION DRAWING INDEX SHEET I ocscaiPnau I ISSUED F -1.0 I FIRE PROTECTION FLOOR PLAN & LEGEND 5 NOTED APPRO - NIIAM -DARE COUNTY FIRE DEFr,RTMENT BLDG. PERMIT FIRE ALARM___- FIRE SUPPRESSION MAIN EXT. MDFR ALL SHOP DRAWINGS LABELED "APPROVED AS NOTED" SHALL BE REVISED AND RESUBMITTED BEFORE FINA L INSPECTION WITH REVISION IDENT(FIriD AND A BRIEF EXPLANATION IN THE TITLE BLOCK. Ali - I /r bolt 24F NnwoJ pa X4V1Cw (MVMv .wr%) SYMBOLS NUMBER OF SPRINKLERS SYMBOL DESCRIPTION TOTAL THIS SHEET: 21 TOTAL THIS JOB: 21 JOB No : 68 -2013 SEAL DRAWING : FIRE PROTECTION FLOOR PLAN &LEGEND e��u�rrurrr� TITLE HYDRAULIC REFERENCE POINTS SYMBOL ORF TEMP RESPONSE K -FAC FINISH MODEL SIN # STYLE PLATE MFG JOB NAME: MSLL LLC .�� J�..• / . REVISIONS: 08 bts] ELEV. BELOW TOP OF STEEL • 1/2 155' QUICK 5.6 CHROME TY -FRB TY3231 RECESSED CHROME TYCO �.` NS • �'(,'�� CONTRACT No : 68 -2013 E8' -6 "] ELEV. ABOVE FINISHED FLOOR O 1/2" 155' QUICK 5.6 CHROME RFII TY3531 / ' C TYCO JOB ADDRESS: 5975 Sunset Dr, Suite 502 MIAMI FL 33143 *:. ! F•';�� 4j27i� = * - O ;••� A OF •:���� �!�S' •' R I O P•''��.`` i � "' • • • \ '� �i� NA L EN� � �rrrrrr�i����� Evelio Rodriguez, P.E. Lic#74127 C ? ELEV. OF TOP OF STEEL 0 / . 1/2- 155' d 5.6 CHROME ° d d d d l 4 ? ° 4 CONCRETE FASTENER (U.L USTED OR F.M. APPROVED) ALL THREAD ROD UVPIPE HANGER RING (U.L USTED OR F.M. APPROVED) HANGER - CONCRETE No Scale GENERAL NOTES 1. INSTALLATION IN ACCORDANCE WITH NFPA 13 (2007 EDITION)• THE FLORIDA FIRE PREVENTION CODE 2010 EDITION AND ALL LOCAL AND STATE A THORITIES. 2. ALL MATERIALS TO BE UL LISTED AND FM - APPROVED 3. SPRINKLERS MAINS 2Y" AND LARGER TO BE SCHEDULE 10 ASTM A -135 BLACK STEEL JOINED BY ROLLED GROOVED METHOD USING GROOVED FITTINGS AND COUPLINGS. 4. BRANCH LINES 2" AND SMALLER TO BE GALVANIZED LIGHT WALL THREADEDABLE XL PIPE CONFORMING TO ASTM A -135 UP TO 300 PSI WORKING PRESSURE 5. DRAIN LINE PIPING 2" AND SMALLER TO BE SCHEDULE 40 ASTM -A53 GALVANIZED STEEL PIPE 150 LBS GALVANIZED MALLEABLE IRON THREADED OUTLET FITTINGS. FOR DRY SYSTEMS. 6. DRAIN LINE PIPING 2" AND SMALLER TO BE SCHEDULE 40 ASTM -A53 GALVANIZED STEEL PIPE 300 LBS GALVANIZED DUCTILE IRON THREADED OUTLET FITTINGS. FOR WET PIPE SYSTEMS. 7. SPRINKLER MAINS AND GROOVED BRANCH LINES ( DRY SYSTEMS) 1Y" AND LARGER TO BE SCHEDULE 10 ASTM A- 1351795 GALVANIZED STEEL JOINED BY ROLL GROOVED METHOD USING PAINTED GROOVED FITTINGS & COUPLINGS. 8. DRY PIPE SYSTEMS AND EXTERIOR PIPING 1" AND SMALLER TO BE SCHEDULE 40 ASTM- AI35/795 GALVANIZED STEEL PIPE JOINED WITH 300 LB DUCTILE IRON FITTINGS WITH STANDARD FINISHED. 9. ALL DRY PIPE MAINS TO BE PITCHED AT Y" PER 10 FEET AND BRANCH LINES TO BE PITCHED Y2" IN 10 FEET FOR DRAINAGE. 10. +0' -0" = SPRINKLER PIPING CENTER LINE ELEVATION ABOVE FLOOR. 11. HANGERS TO BE SIZED AND SPACED IN ACCORDANCE WITH NFPA -13, SECTION 9.1 2010 EDITION. 12. HANGER RODS TO BE ZINC PLATED ALL THREADED. 13. ACCESS PANELS TO BE PROVIDED ABOVE ALL ACCESSIBLE CEILINGS AND CHASES. 14. FIRE SPRINKLERS TO BE INSTALLED UNDER ALL EXPOSED DUCTWORK OVER 48" WIDE. (SPRINKLER HEADS UNDER DUCTS ARE NOT INDICATED ON PLANS, BUT ARE REQUIRED AND SHALL BE PROVIDED IN ACCORDANCE TO NFPA -13. 15. SPRINKLER HEADS GUARDS ARE REQUIRED ON ALL SPRINKLER HEADS IN ELECTRICAL ROOMS TELEPHONE ROOMS, ELEVATOR ROOMS, ELEVATOR SHAFTS AND ANY SPRINKLERS BELOW 7' -0" AFF. 16. ALL INDICATING CONTROL VALVES TO BE PROVIDED WITH TAMPER SWITCHES. 17. UNDERGROUND SCOPE OF WORK TO COMMENCE AS INDICATED ON PLANS. 18. UNDERGROUND PIPING SHALL BE DR -14 C -900 PVC FOR PRESSURES EXCEEDING 150 PSI, CLASS 350 DUCTILE IRON PIPE SHALL BE IN VERTICAL RISERS AND AT PENETRATION POINT AT BUILDING FOUNDATION. 19. CHANGES IN DIRECTION OF PIPING TO BE MADE BY USE OF MECHANICAL JOINT FITTINGS. 20. THRUSTS RESTRAINS TO BE PROVIDED AT ALL TURNS AND ENDS OF MAIN PER NFPA -24 21. 200 LBS 0 2 HOURS PRESSURE TESTING AND FLUSHING TO BE PERFORMED PER NFPA -24 22. FLUSHING AND TESTING OF UNDERGROUND PIPING TO BE PERFORMED AS PER NFPA -24 23. WET BULK SUPPLY MAINS AND HOSE SUPPLY MAINS EXPOSED TO THE WEATHER SHALL BE INSULATED AND PROVIDED WITH AN ALUMINUM JACKET. 24. SPRINKLERS IN ELEVATOR SHAFTS AND EQUIPMENT ROOMS ARE TO BE INTERMEDIATE TEMPERATURE 2007 SPRINKLERS PER NFPA 13. 25. IF SYSTEM PRESSURE - EXCEEDS 100 PSI, ALL HANGERS ON-END HEADS IN PENDANT POSITION SHAL BE WITHIN 12" OF END OF LINE IN ACCORDANCE WITH NFPA 13 26. SPRINKLERS SHALL BE PROVIDED AT THE TOP AND BOTTOM OF ALL STAIRWELLS AND AT THE LANDING OF EACH FLOOR THAT OPENS INTO MORE THAN ONE FIRE ZONE. FIRE PROTECTION DRAWING INDEX SHEET I ocscaiPnau I ISSUED F -1.0 I FIRE PROTECTION FLOOR PLAN & LEGEND 5 NOTED APPRO - NIIAM -DARE COUNTY FIRE DEFr,RTMENT BLDG. PERMIT FIRE ALARM___- FIRE SUPPRESSION MAIN EXT. MDFR ALL SHOP DRAWINGS LABELED "APPROVED AS NOTED" SHALL BE REVISED AND RESUBMITTED BEFORE FINA L INSPECTION WITH REVISION IDENT(FIriD AND A BRIEF EXPLANATION IN THE TITLE BLOCK. Ali - I /r bolt 24F NnwoJ pa X4V1Cw (MVMv .wr%) SYMBOLS NUMBER OF SPRINKLERS SYMBOL DESCRIPTION TOTAL THIS SHEET: 21 TOTAL THIS JOB: 21 JOB No : 68 -2013 SEAL DRAWING : FIRE PROTECTION FLOOR PLAN &LEGEND e��u�rrurrr� TITLE HYDRAULIC REFERENCE POINTS SYMBOL ORF TEMP RESPONSE K -FAC FINISH MODEL SIN # STYLE PLATE MFG JOB NAME: MSLL LLC .�� J�..• / . REVISIONS: 08 bts] ELEV. BELOW TOP OF STEEL • 1/2 155' QUICK 5.6 CHROME TY -FRB TY3231 RECESSED CHROME TYCO �.` NS • �'(,'�� CONTRACT No : 68 -2013 E8' -6 "] ELEV. ABOVE FINISHED FLOOR O 1/2" 155' QUICK 5.6 CHROME RFII TY3531 / CONCEALED CHROME TYCO JOB ADDRESS: 5975 Sunset Dr, Suite 502 MIAMI FL 33143 *:. ! F•';�� 4j27i� = * - O ;••� A OF •:���� �!�S' •' R I O P•''��.`` i � "' • • • \ '� �i� NA L EN� � �rrrrrr�i����� Evelio Rodriguez, P.E. Lic#74127 DRAWN BY : A.A.R. (tos 20' -O) ELEV. OF TOP OF STEEL 0 / . 1/2- 155' QUICK 5.6 CHROME DS- 1/TY3230 DRY PENDENT CHROME TYCO to -o CEILING HEIGHT O 1/2 155' QUICK 5.6 BRASS TY- FRB/TY3131 UPRIGHT NONE GENERAL CONTRACTOR: 00 PENNNAVEUCTION INC. PITTSBURGH, PA 15221 PHONE: 412- 243 -2483 FAX:412- 243 -7925 SCALE : AS SHOWN �- DENOTES HANGER LOCATION O 1/2" 155' QUICK 5.6 BRASS TY- FRB /TY3231 PENDENT NONE TYCO 0 RISE UP OR DOWN 0 1/2" 155' QUICK 5.6 BRASS TY- FRB /TY3131 UPRIGHT HD /GD TYCO DATE : 12 -03 -13 Q 1/2 " 155' QUICK 5.6 CHROME TY- FRB /TY3331 HOR. SIDEWALL CHROME TYCO 1/2" 155' QUICK 5.6 CHROME EC.S TY3302 / EX COV HOR SW CHROME TYCO APPROVED BY :EVEI P.E. Lic#74127 ® 1 2" 286' QUICK 5.6 BRASS TY -FRB TY3331 HOR. SIDEWALL HD GD TYCO P.E. TE: YES O I w