Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13-1218-042
CASE 1., 3 H ELEC: _ I� F•, I , AIR cy I DRAIN + -1- WATER VAC. A' 1 ' -0" - TOP VIEW " - x 00 . -� I SECTION AT FLOOR TYPICAL UTILITY CENTER /NOT TOI SCALE (�,I - SECTION AT FLOOR r,_, S0RFACE MOUNTED OUTLET @ CHAIR NOT TO SCALE i 208/23( LINE REMOTE INTAKE \—CONNECT AIR W/ 1/2" NPT NOTES 1. 1/2" FNPT SHUT -OFF VALVE AND A 4 FT. PRESSURE HOSE (SUPPLIED) 2. AIR DISTRIBUTION PIPING: 1/2" TYPE "L" OR "K" COPPER 3. ALLOW 12" SERVICE CLEARANCE ON ALL SIDES DERAIL PROVIDED POP, INFORMATION ONLY. PLEASE REFER TO MANUFACTURER'S INSTALLATION MANNA[.. INSTALLATION MUST CONFORM TO ALL LOCAL ELECTRICAL AND PLUMPING CODES. PRODUCT SPECIFICATIONS FIP 4.5 GENERAL NOTES: 7" I VOLTAGE MIN /MAX -THIS DETAIL IS FOR INFORMATIONAL PURPOSES ONLY. DENTAL DEALER DIMENSIONS (HxWxD) -�, RESPONSIBLE FOR AN INSTALLATION WHICH DOES NOT MEET LOCAL ELECTRICAL AND PLUMBING CODES. WILL PROVIDE INSTALLATION TEMPLATES FOR ANY EQUIPMENT IN CENTRAL VACUUM: PLUMBING CONTRACTOR TO INSTALL A 1/2" COPPER (OR ACCEPTED) SUPPLY LINE PROVIDE A BRANCH LINE TO LOCATION SHOWN (SIZE FROM AIR COMPRESSOR TO THIS LOCATION. STUB -UP PER CENTRAL VACUUM SUPPLIER). REDUCE TO A 1/2" QUESTION, REFER TO MANUFACTURER'S INSTALLATION GUIDE /TEMPLATE FOR ADDITIONAL INFORMATION. SCH. 40 PVC (OR COPPER) RISER AT FLOOR. TERMINATE COMPRESSION SHUT -OFF VALVE. FLUSH SYSTEM CLEAN 1 -2" ABOVE FINISHED FLOOR FOR CONNECTION TO PRIOR TO EQUIPMENT INSTALLATION. ELEC.I WATER. PLUMBING CONTRACTOR TO PROVIDE AND GRAVITY DRAIN: PLUMBING CONTRACTOR TO PROVIDE - LICENSED PLUMBERS AND ELECTRICIANS SHALL INSTALL ALL UTILITIES. t_,. + (� - I SUPPLY UP LIN E TO THIS LOCATION. STUB UP 1 -2" FROM REDUCE TO A 3/4" SCH 40 PVC RISER BELOW SLAB. -ALL UTILITIES MUST CONFORM WITH PREVAILING LOCAL CODES. NEITHER DENTAL DEALER NOR MANUFACTURER CAN BE HELD RESPONSIBLE FOR AN TOE � -- _ _I PRIOR TO EQUIPMENT INSTALLATION. VENTED FITTING TO CONFORM WITH LOCAL CODES, INSTALLATION WHICH DOES NOT MEET LOCAL ELECTRICAL AND PLUMBING OF —__ I —_ - ) SUB -FLOOR (SEE SPECS 4,4A SHEET SE.1 FOR SIZE AND CODES, CHAIR 1.. 2" CONDUIT ELEC_ TRICAL.: ELECTRICAL CONTRACTOR TO PROVIDE 50 GAL. TANK TREATMENT ROOM CANNOT EXCEED 100 PSI. AND INSTALL A 1/2" CONDUIT AND BOX WITH 115V TOP VIEW DUPLEX (OR EQUAL) RECEPTACLE. WIRE BOX PER — --- -- DRAIN OR P -TRAP) CODE WITH TOP NO HIGHER THAN 4-1/2" A.F.F. — LINE STUB -UP REQUIREMENTS WITHIN < CONDUIT: ELECTRICAL CONTRACTOR TO PROVIDE A OGRAY l ROOM. FOLLOWING ALL LOCAL CODES FOR ELECTRICAL PVC PIPE CHASE WITH PULL - STRING J FLOOR SUB -FLOOR (SEE SPECS 4, 4A SHEET SE,I FOR SIZE AND LOCATIONS). 6" MIN. RADIUS FOR ALL BENDS. STUB -UP NOTE: ` FLUSH WITH SUB - FLOOR, MARK LOCATION OF PIPE AT (I ;T EXACT REQUIREMENTS. VERIFY LOCAL CODES BEFORE FINISH. - SECTION AT FLOOR r,_, S0RFACE MOUNTED OUTLET @ CHAIR NOT TO SCALE i 208/23( LINE REMOTE INTAKE \—CONNECT AIR W/ 1/2" NPT NOTES 1. 1/2" FNPT SHUT -OFF VALVE AND A 4 FT. PRESSURE HOSE (SUPPLIED) 2. AIR DISTRIBUTION PIPING: 1/2" TYPE "L" OR "K" COPPER 3. ALLOW 12" SERVICE CLEARANCE ON ALL SIDES DERAIL PROVIDED POP, INFORMATION ONLY. PLEASE REFER TO MANUFACTURER'S INSTALLATION MANNA[.. INSTALLATION MUST CONFORM TO ALL LOCAL ELECTRICAL AND PLUMPING CODES. PRODUCT SPECIFICATIONS FIP 4.5 VOLTAGE RATING 203/230 VOLTAGE MIN /MAX 200/250 DIMENSIONS (HxWxD) 33x45x26 SITE REQUIREMENTS VOLTAGE MIN_ /MAX 200/250 FULL LOAD AMPS 24 MIN, CIRCUIT BREAKER RATING (AMPS) AO MIN WIRE SIZE (AWG) 3 1AIRSTAR -70 AIR COMPRESSOR NOT TO SCALE GENERAL NOTES: BISON 5,7 THIS DETAIL IS FOR INFORMATIONAL PURPOSES ONLY, DENTAL DEALER WILL PROVIDE INSTALLATION TEMPLATES FOR ANY EQUIPMENT IN QUESTION. REFER TO MANUFACTURER'S INSTALLATION GUIDE/TEMPLATE FOR ADDITIONAL INFORMATION. - LICENSED PLUMBERS AND ELECTRICIANS SHALL INSTALL ALL UTILITIES. -ALL UTILITIES MUST CONFORM WITH PREVAILING LOCAL CODES. NEITHER DENTAL DEALER NOR MANUFACTURER CAN BE HELD RESPONSIBLE FOR AN INSTALLATION WHICH DOES NOT MEET LOCAL ELECTRICAL AND PLUMBING CODES. AIR: PLUMBING CONTRACTOR TO PROVIDE AND CENTRAL VACUUM: PLUMBING CONTRACTOR TO INSTALL A 1/2" COPPER (OR ACCEPTED) SUPPLY LINE PROVIDE A BRANCH LINE TO LOCATION SHOWN (SIZE FROM AIR COMPRESSOR TO THIS LOCATION. STUB -UP PER CENTRAL VACUUM SUPPLIER). REDUCE TO A 1/2" 1 -2" FROM FLOOR AND TERMINATE WITH A 90' 1/2" x 3/8" SCH. 40 PVC (OR COPPER) RISER AT FLOOR. TERMINATE COMPRESSION SHUT -OFF VALVE. FLUSH SYSTEM CLEAN 1 -2" ABOVE FINISHED FLOOR FOR CONNECTION TO PRIOR TO EQUIPMENT INSTALLATION. EQUIPMENT. WATER. PLUMBING CONTRACTOR TO PROVIDE AND GRAVITY DRAIN: PLUMBING CONTRACTOR TO PROVIDE INSTALL A 1/2" COPPER (OR ACCEPTED) COLD WATER A COMMON DRAIN LINE TO LOCATION SHOWN. SUPPLY UP LIN E TO THIS LOCATION. STUB UP 1 -2" FROM REDUCE TO A 3/4" SCH 40 PVC RISER BELOW SLAB. FLOOR AND TERMINATE WITH A 90" 1/2" x 3/8" TERMINATE 1 -2" ABOVE F1141SHED FLOOR FOR COMPRESSION SHUT -OFF VALVE. FLUSH SYSTEM CLEAN CONNECTION TO EQUIPMENT. PROVIDE TRAP & PRIOR TO EQUIPMENT INSTALLATION. VENTED FITTING TO CONFORM WITH LOCAL CODES, ELECTRICAL: ELECTRICAL CONTRACTOR TO PROVIDE CHASE: ELECTRICAL CONTRACTOR TO PROVIDE A AND INSTALL A 1/2" CONDUIT AND BOX WITH 115V GRAY ELECTRICAL PVC PIPE CHASE WITH PULL - STRING QUAD (OR EQUAL) RECEPTACLE. WIRE BOX PER CODE SUB -FLOOR (SEE SPECS 4,4A SHEET SE.1 FOR SIZE AND WITH TOP NO HIGHER THAN 4 -1 /2" A.F.F. LOCATIONS). 6' MIN. RADIUS FOR ALL BENDS. STUB -UP -WATER PRESSURE TO VALVE FLUSH WITH SUB - FLOOR, MARK LOCATION OF PIPE AT FINISH. 1/2" O.D. OXYGEN FROM TANK ^ ^ ^, BY PLUMBER 3/8" Q.D. NIT FROM TANK BY PLUMBER WALL FRAMII BRACKET "A" MOUNT TO S BEFORE GYP, OUTLET STATION PROVIDED BY HENRY SCHEIN DENTAL AND INSTALLED BY PLUMBER NOTE: IF RUNNING VACUUM FROM ABOVE OUTLET STATION (OVERHEAD SYSTEMS), VACUUM PIPING FOR GAS SCAVENGING MUST INCLUDE VERTICAL TRAP TO PREVENT BACK -FLOW OF LIQUIDS INTO VACUUM BLOCK. SEE MANUFACTURER FOR DETAILS. HEIGHT TO BE DETERMINED ON SITE UNLESS NOTED OTHERWISE 1/2" O.D. VACUUM LINE BY PLUMBER. TIE INTO MAIN TRUNK LINE COMING FROM MECHANICAL CLOSET. THIS DRAWING REPRESENTS A TYPICAL INSTALLATION AND IS FOR INFORMATIONAL PURPOSES ONLY. REVIEW MANUFACTURER SPECIFICATIONS FOR EXACT MODEL AND SYSTEM REQUIREMENTS. N20, 02AND VACUUM OUTLET STATION NOT TO SCALE NOTE: EXACT LOCATION AND SINK SIDE MAY VARY. TO BE SPOTTED BY HENRY SCHEIN DENTAL EQUIPMENT REP. ELECTRICAL: ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL A BOX WITH I I 5 DUPLEX RECEPTACLE AT 18" A.F.F. —I ULTRASONIC io CLEANER GENERATOR ULTRASONIC CLEANER NOT TO SCALE MODEL BISON 5,7 TOTAL HP 3.0 VOLTAGE 230 BREAKER SZ. 20A HERTZ 60 AMPS 14 WIDTH 24" DEPTH 24" HEIGHT 72" DEDICATED CIRCUIT BUILDING' POWER SUPPLY PANEL ELECTROL (SUPPLIED BY RECESSED ULTRASONIC CLEANER & GENERATOR PROVIDED AND INSTALLED BY HENRY SCHEIN DENTAL, PLUMBING CONTRACTOR TO PROVIDE & INSTALL A 3/4" DISHWASHER TEE ON DRAIN STAND PIPE FOR ULTRASONIC DRAIN HOSE, r- DISCONNECT TO REMOTE CONTROL PANEL (OPTIONAL) EXHAUST TO OUTSIDE BUILDING (2" SCH. 80 PVC OR METAL) VERIFY AMBIENT ROOM 3.0 RAMVAC) 203/230 o p DIMENSIONS (HXWXD) TEMPERATURE AND JUNCTION BOX UNIT PROVIDED BY HENRY VENTILATION REQUIREMENTS (OPTIONAL) ELECTRICIAN TO PROVIDE BY PLUMBER. WITH MANUFACTURE PLUMBING CONTRACTOR TO PROVIDE PRE - INSTALLATION GUIDE a° 20" CENTER TO CENTER CLEARANCE TR / TANK LINE FOR VALVE MOUNTING BETWEEN THE 1 -1/2" OR 2" PVC W/ DWV FITTINGS OR COPPER PER �+ -WATER PRESSURE TO VALVE LOCAL COD VALVE & THE OUTGOING LINE FEEDING 50 GAL. TANK TREATMENT ROOM CANNOT EXCEED 100 PSI. DRAIN LINE (TO FLOOR THE FACILITY. SEE DETAIL(S) 1,3 OR 3A FOR VACUUN DRAIN OR P -TRAP) LINE STUB -UP REQUIREMENTS WITHIN 1 1/2" PVC PIPE -DO NOT CONNECT ON A ROOM. FOLLOWING ALL LOCAL CODES FOR FLOOR INSTALLATION. NOTE: VACUUM LINES PER LOCAL CODE. REFER TO RAMVAC SPECS AND PRE - INSTALLATION GUIDE FOR SLOPE MINIMUM 114" PER 10 FEET. EXACT REQUIREMENTS. VERIFY LOCAL CODES BEFORE INSTALLING UNIT. RAMVAC BISON 5 OR 7 VACUUM )A- OF FLEX CONDUIT WATER CABINET 2 GANG STEEL BOX GENERAL NOTES: WITH QUAD OUTLET -THIS DETAIL IS FOR INFORMATIONAL PURPOSES ONLY, DENTAL DEALER WILL PROVIDE INSTALLATION TEMPLATES FOR ANY W AIR I 12" EQUIPMENT IN QUESTION. REFER TO MANUFACTURER'S INSTALLATION GUIDEITEMPLATE FOR ADDITIONAL INFORMATION. REAR WALL- „ .1 „2„ CHASE TO *ANCHOR UTILITIES TO A CEILING STUD OR CROSS BRACE - LICENSED PLUMBERS AND ELECTRICIANS SHALL INSTALL ALL UTILITIES. WITHIN WALL TO PREVENT MOVEMENT -ALL UTILITIES MUST CONFORM WITH PREVAILING LOCAL CODES. NEITHER DENTAL DEALER NOR MANUFACTURER CAN BE HELD *ALL DIMENSIONS ARE RESPONSIBLE FOR AN INSTALLATION WHICH DOES NOT MEET LOCAL ELECTRICAL AND PLUMBING CODES. SUBJECT TO JOB-SITE VERIFICATION WITH HENRY - VERIFY WITH EQUIPMENT REP WHICH UTILITIES WILL BE RUN SUB -FLOOR VS. IN WALL. SCHEIN EQUIPMENT REP. AIR: PLUMBING CONTRACTOR TO PROVIDE AND CENTRAL VACUUM: PLUMBING CONTRACTOR TO :::::IT02P VIEW CHASE TO CHAIR INSTALL A 1/2” COPPER (OR ACCEPTED) SUPPLY LINE PROVIDE A BRANCH LINE TO LOCATION SHOWN (SIZE PER VAC. I FROM AIR COMPRESSOR TO THIS LOCATION. STUB -OUT CENTRAL VACUUM SUPPLIER). REDUCE TO A 1/2" SCH. 40 1 -2" FROM WALL AND TERMINATE WITH A 90. 1/2" x 3/8" PVC (OR COPPER) RISER 1 -2" ABOVE FINISHED FLOOR FOR REAR WALL I CHASE TO CEILING COMPRESSION SHUT -OFF VALVE. FLUSH SYSTEM CLEAN CONNECTION TO EQUIPMENT. ^� SINGLE GANG MUD RING PRIOR TO EQUIPMENT INSTALLATION. N20, O2SYSTEM CHECK VALVES: SEE DETAILS 33, N20, ELECTRICAL WATER: PLUMBING CONTRACTOR TO PROVIDE AND INSTALL AND 7C FOR SYSTEM INFORMATION. REQUEST VALVES WATER ------ I A 1 /2" COPPER (OR ACCEPTED) COLD WATER SUPPLY LINE TO FROM DENTAL DEALER EQUIPMENT REP FOR AIR THIS LOCATION. STUB -OUT 1 -2" FROM WALL AND TERMINATE INSTALLATION DURING ROUGH -IN. ALL WORK BY MED- WITH A 90' 1/2" x 3/8" COMPRESSION SHUT -OFF VALVE. FLUSH GAS CERTIFIED PLUMBER (WHERE REQUIRED BY CODE). SYSTEM CLEAN PRIOR TO EQUIPMENT INSTALLATION. x' CHASE: ELECTRICAL CONTRACTOR TO PROVIDE A GRAY ELECTRICAL PVC PIPE CHASE WITH PULL - STRING ELECTRICAL: ELECTRICAL CONTRACTOR TO PROVIDE SUB -FLOOR (SEE SPECS 4, 4A SHEET SE.1 FOR SIZE AND AND INSTALL A 1 /2" FLEX CONDUIT AND BOX WITH 115 LOCATIONS). C" MIN. RADIUS FOR ALL BENDS. STUB -UP QUAD (OR EQUAL) RECEPTACLE. WIRE BOX PER CODE FLUSH WITH SUB - FLOOR, MARK LOCATION OF PIPE AT WITH TOP NO HIGHER THAN 4 -1/2" A.F.F. FINISH. VAC. ELEVATION VIEW CHASE TO CHAIR C USTOM R E�AR WALLU�T LI TI ES NOT TO SCALE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FOLLOWING ALL LOCAL CODES FOR ROUGH INSTALLATION. HENRY SCHEIN TO MAKE FINAL CONNECTIONS. ELECTRICIAN TO PROVIDE A FLUSH- MOUNTED SINGLE GANG JUNCTION BOX & 3/4" CONDUIT W/ PULL -WIRE BETWEEN EXPOSURE BUTTON & X -RAY MASTER CONTROL /UNIT. u: 0 X -RAY EXPOSURE BUTTON (TYP.) .. SINK BASIN DEPTH, PLA INSTALLED I, VERIFY WIRING REQUIREMENTS BETWEEN EXPOSURE BUTTON AND X -RAY MASTER CONTROL /UNIT WITH MANUFACTURER'S INSTALLATION MANUAL. PROVIDED BY HENRY - SCHEIN DENTAL, INSTALLED BY ELECTRICIAN. SEE MANUFACTURER'S INSTALLATION MANUAL FOR MORE DETAIL, X -RAY EXPOSURE BUTTON NOT TO SCALE MOD WATER: PLUMBING CONTRACTOR TO PROVIDE AND INSTALL A 1/2" COPPER (OR ACCEPTED) COLD WATER SUPPLY LINE AT 44" A.F.F. STUB -OUT FROM WALL AND TERMINATE WITH A 90.3/8" COMPRESSION STOP. MODEL TRIMMER PROVIDED AND INSTALLED BY HENRY SCHEIN DENTAL. ELECTRICAL: ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL A BOX WITH 115V DUPLEX RECEPTACLE AT 44" A.F.F. LOOSE DRAIN HOSE FROM MODEL TRIMMER INTO SINK. PLASTER TRAP AND CONNECTION HOSES PROVIDED BY HENRY SCHEIN DENTAL. VERTICAL HOSE BEND SHOULD BE NO GREATER THAN 90' NOTE: EXACT LOCATION AND SINK SIDE MAY VARY. TO BE SPOTTED BY HENRY SCHEIN DENTAL EQUIPMENT REP, BACK FLOW PREVENTION MAY BE REQUIRED, CHECK LOCAL CODES. PLASTER TRAP & HOSES REPLACE THE STANDARD P -TRAP AT SINK. PLUMBING CONTRACTOR TO PROVIDE TYPICAL DRAIN STUB -OUT FROM WALL, EL TRIMMER & DISPOSABLE NOT TO SCALE 1/2" SLIP x 1/2" F PROVIDED & IN CONTRACTOR, PLASTER TRAP VACUUM WALL OUTLET NOT TO SCALE 1/2" PVC SLIP X SLIP, 90• ELBOW. PROVIDED & INSTALLED BY CONTRACTOR. ANCHOR TERMINATION FITTINGS SECURELY TO A STUD OR A CROSS BRACE. FITTINGS PROVIDED AND INSTALLED BY CONTRACTOR. 1/2" SCH 40 PVC BRANCH FROM DUST COLLECTION UNIT (SEE SHEET SP.1) SEE ACTUAL VALVE TO ADJUST THE MOUNTING POSITION OF THE 1/2" FPT ADAPTOR SO THE TRIM RING IS SECURED FIRMLY AGAINST THE SHEETROCK, AIR VALVE PROVIDED AND INSTALLED BY CONTRACTOR. - 3/8" COMPRESSION FITTING OR OPTIONAL FEMALE QUICK DISCONNECT PROVIDED & INSTALLED BY CONTRACTOR. A�RVA LVE NOT TO SCALE ROUTE TO DESIGNATED REMOTE AREA FOR AIR INTAKE BUILDING POWER SUPPLY PANEL 2" PIPE FOR AIR INTAKE BOOST TRANSFORMER REMOTE AIR (OPTIONAL) MANIFOLD 8" MAX - • PB REMOTE 24V SHUTOFF PANEL CONTROL CABLE rn 18 GAUGE 3 CONDUCTOR NOTES: 1. 1/2" FNPT SHUT -OFF VALVE AND A 4 FT. PRESSURE HOSE (SUPPLIED) 2. AIR DISTRIBUTION PIPING: 1/2" TYPE "L" OR "K" COPPER 3. ALLOW 12" SERVICE CLEARANCE ON ALL SIDES 1 /2" FEMALE ADAPTOR PROVIDED & INSTALLED BY ONTRACTOR. �� AIR LINE BY CONTRACTOR e ANCHOR TERMINATION FITTINGS SECURELY TO A STU OR A CROSS BRACE. FITTINGS PROVIDED AND INSTALLED BY CONTRACTOR. DETAIL PROVIDED FOR INFORMATION ONLY PLEASE REFER TO MANUFACTURER'S INSTALLATION MANUAL. INSTALLATION MUST CONFORM TO ALL LOCAL ELECTRICAL AND PLUMPING CODES. PRODUCT SPECIFICATIONS H P 3.0 VOLTAGE RATING 203/230 VOLTAGE MIN /MAX 200/250 DIMENSIONS (HXWXD) 3lx33x25 SITE REQUIREMENTS VOLTAGE MIN /MAX 200/250 FULL LOAD AMPS 14.0 MIN. CIRCUIT BREAKER RATING (AMPS) 30 MIN WIRE SIZE (AWG) 10 3' MAX 2' MAX 1/2" MNPT MAIN AIR LINE ��AIRSTAR -50 AIR COMPRESSOR NOT TO SCALE ELECTRICIAN TO INSTALL A SINGLE GANG JUNCTION SEE MANUFACTURER'S BOX & 1/2" CONDUIT FROM BOX TO 3" ABOVE CEILING INSTALLATION MANUAL FOR (CONTINUOUS TO REMOTE PANEL, 32 OR 32A, WHEN MORE INFORMATION. PLENUM SPACE IS NOT ACCESSIBLE). PULL L/V WIRES BETWEEN VALVE AND REMOTE PANEL. UNIT PROVIDED BY HENRY SCHEIN DENTAL, INSTALLED ELECTRICIAN TO PROVIDE BY PLUMBER. SINGLE GANG JUNCTION BOX &115V DUPLEX OUTLET GD o FOR VALVE. „ 3/4 "SOLDER UNION 3/4" SOLDER UNION OUT BUILDING SUPPLY o �- FLOW TO OFFICE LL: INT.SQ.FT.= BY OTHERS PLUMBING CONTRACTOR TO PROVIDE a° 20" CENTER TO CENTER CLEARANCE FOR VALVE MOUNTING BETWEEN THE MAIN LINE STUB -OUT COMING INTO THE -WATER PRESSURE TO VALVE VALVE & THE OUTGOING LINE FEEDING CANNOT EXCEED 100 PSI. THE FACILITY. CONTRACTORS ARE RESPONSIBLE FOR -DO NOT CONNECT ON A FOLLOWING ALL LOCAL CODES FOR HOT WATER LINE INSTALLATION. A AIR TECHNIQUES W�AT ER SH I_UT -O W/ , _FF NOT TO SCALE FILTER u V J W Z LJJ P4 Z J CV 0 co Z Li Op Q cci W 0 `) C^ w CD J Q z W 0 H— O U W 0 o_ 0 cy) V -I u.l u_ �Q p -_ Z �0 Z Lo Q U O J HENRY SCHEIN REP.- JOHN TURNER CENTER: WEST PALM BEACH ( PHONE - - - -- 800 645 -6591 Lu 0 00 q Lu 3> -d u- ui 7- w CL D! 0 < uj �0UwLu u- F- 0 w n >- LlIj Z Lu p O ��0 �� �. t U ui i-i tn <4K 0p LL UJ 0 U Q F- Q F Z D-i O .. UJ F-- Q LL' z c>% w a- t1 ��enujryLu © -. I = Q F- -n o W p p ©w >- 4 31O wzLIJz0zU�„ �co Qp< 0Lu0ua 5�--Z ui I- Ilry wwQZ L ZpmL:E Z0� z Q vs _'uZL- O Z O� ©U<U w 0--V)27— V) Q >- r w LTi L- p E uj I- O z � �t DRAWING NAME: SOUTHMIAMI -F PROJECT START DATE: 07/02/2013 FINALS START DATE: 09/10/2013 DRAWN BY: OTHERS FINALS BY: TAS CHECKED BY: JBK REVISIONS: INT.SQ.FT.= BY OTHERS SCALE: SHT. SIZE' SEE DTL. D META �LS C: z Z LL 7 v rx LL c� G