Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13-1218-035
TOE OF CHAIR SIDE VIEW 2x4 FRAMING & CROSS BRACING Al NEEDED TO PROVIDE SUPPORT & ELIMINATE MOVEMENT HEAD OF CHAIR 115V, 15A POWER SUPPLY. BRING IN AT LOCATION SHOWN, WALL SWITCH MAY BE INSTALLED BETWEEN BUILDING POWER SUPPLY AND LIGHT FOR SERVICING. - 2x12, LENGTH AS SHOWN, MOUNT EITHER DIRECTLY ABOVE (OR) FLUSH WILL I FINISHED CEILING. CONSULT WITI I HENRY SCHEIN REP ON WHICH IS PREFERRED. SECURE FRAMING TO STRUCTURE ABOVE BASED ON LOCAL CODES & LOAD REQUIREMENTS, 2x4 FRAMING & CROSS BRACING AS NEEDED TO PROVIDE SUPPORT & ELIMINATE MOVEMENT 2x6 LUMBER SUSPENSION WIRE FLUORESCENT FIXTURE SUSPENSION TEE ACOUSTICAL CEILING TILE 2x12. MOUNT EITHER DIRECTLY ABOVE (OR) FLUSH WITI I FINISHED CEILING. CONSULT WITH HENRY SCHEIN REP ON WHICH IS PREFERRED. NOTE: IF MOUNTING ABOVE FINISHED CEILING, PLYWOOD FILLER CAN BE USED BETWEEN 2x12 AND UPPER SURFACE OF CEILING TILE AS NEEDED. NOTES: 1. CEILING MOUNTED LIGHT SUPPORTS SHALL WITHSTAND A 200 LB. DEAD LOAD (MIN., 300 LB. IF MOUNTING A MONITOR ON THE TRACK). FRAMING SHALL BE BRACED LATERALLY AND LONGITUDINALLY TO PROVIDE A RIGID AND LEVEL SUPPORT. 2. WHERE REQUIRED BY LOCAL CODE, NON - COMBUSTIBLE MATERIALS AND /OR 5/8" FIRE CODE RATED GYP. BRD. TO WRAP THIS SUPPORT MAY BE REQUIRED FOR FIRE RATED CEILINGS. VERIFY EXACT REQUIREMENTS WITH LOCAL AUTHORITIES. 3. THIS IS ATYPICAL INSTALLATION. CONSULT HENRY SCHEIN DENTAL EQUIPMENT SALES SPECIALIST FOR EXACT REQUIREMENTS AND SPECS OF EQUIPMENT TO BE INSTALLED ON SITE. 4. MOUNTING MATERIALS SUPPLIED AND INSTALLED BY CONTRACTOR. CEILING MOUNTED TRACE LIGHT_-- NOT TO SCALE 115V, 15A POWER SUPPLY. WALL SWITCH MAY BE INSTALLED BETWEEN BUILDING POWER SUPPLY AND LIGHT FOR SERVICING. CROSS SECTION SECURE FRAMING TO STRUCTURE ABOVE BASED ON LOCAL CODES & LOAD REQUIREMENTS. 2x4 FRAMING & CROSS BRACING AS NEEDED TO PROVIDE SUPPORT & ELIMINATE MOVEMENT 2x6 LUMBER SUSPENSION WIRE SUSPENSION TEE ACOUSTICAL CEILING TILE TWO 2xl2'S, 24" LONG. MOUNT AS CLOSE TO UPPER SURFACE OF CEILING TILE AS POSSIBLE. KEEP THIS AREA CLEAR FOR LIGHT MOUNTING SPACERS /BOLTS. NOTES: 1. CEILING MOUNTED LIGHT SUPPORTS SHALL WITHSTAND A 200 LB. LIVE LOAD. FRAMING SHALL BE BRACED LATERALLY AND LONGITUDINALLY TO PROVIDE A RIGID AND LEVEL SUPPORT. 2. WHERE REQUIRED BY LOCAL CODE, NON - COMBUSTIBLE MATERIALS AND /OR 5 /8" FIRE CODE RATED GYP. BRD. TO WRAP THIS SUPPORT MAY BE REQUIRED FOR FIRE RATED CEILINGS. VERIFY EXACT REQUIREMENTS WITH LOCAL AUTHORITIES. 3. THIS IS A TYPICAL INSTALLATION. CONSULT HENRY SCHEIN DENTAL EQUIPMENT SALES SPECIALIST FOR EXACT REQUIREMENTS AND SPECS OF EQUIPMENT TO BE INSTALLED ON SITE. 4. MOUNTING MATERIALS SUPPLIED AND INSTALLED BY CONTRACTOR, CEILING MOUNTED POST LIGHT NOT TO SCALE 4x4 POSTS 0 4" ON WALL MOUNTING I PROVIDED BY MAt JUNCTION BOX PC INTERCONNECTIN, REMOTELY MOUNI CONTROL PANEL. *X -RAY UNIT REQU POWER ON A DEC CIRCUIT. FLUSH MOUNTED SINGLE -GANG JU' 5 /E" GYP. BRD, BOTH SIDES SEE MANUFACTURER'S INSTALLATION TEMPLATE FOR MORE DETAIL, INSTALLER MUST VERIFY THAT WALL AND MOUNTING HARDWARE MEETS THE REQUIREMENTS FOR SHEAR LOAD, WITHDRAWAL FORCE AT EACH MOUNTING POINT AND LOAD MOMENT AS OUTLINED IN THE MANUFACTURER'S INSTALLATION MANUAL. MOUNTING MATERIALS SUPPLIED AND INSTALLED BY CONTRACTOR. TYPICAL X -RAY SCALE 3/4" = V -0" 2x4 WOOD FRAMED VERTICAL STUDS ANCHOR VERTICAL 2x4'S TO ROOF STRUCTURE. USE METAL SUPPORTS TO ANCHOR VERTICAL 2x4'S ABOVE CEILING IF THIS AREA IS DESIGNATED A NON- COMBUSTABLE AREA. NOTE: IN APPLICATIONS WHERE OFFICE FRAMING MUST BE NON- COMBUSTIBLE, THE USE OF FIRE - RETARDANT TREATED WOOD IS NECESSARY TO PROVIDE THE REQUIRED SUPPORT FOR THE DENTAL I EQUIPMENT. (2) LAYERS OF 3/4" HIGH GRADE PLYWOOD, GLUED AND SCREWED TOGETHER. DO NOT USE OSB OR PARTICLE BOARD. MORTISE STUDS TO ALLOW PLYWOOD TO SIT FLUSH WITH FRAMING. FLUSH - MOUNTED SINGLE -GANG - °--� JUNCTION BOX W/ 3/4" CONDUIT. TERMINATE 3" ABOVE TOP PLATE (OR CONTINUOUS RUN FOR DRYWALL CEILINGS) FOR CONNECTION TO DEDICATED COMPUTER OR SERVER. FLUSH- MOUNTED SINGLE -GANG JUNCTION BOX W/ 3/4" CONDUIT TO (95) LOCATION IN HALL. PULL 3 CONDUCTOR THERMOSTAT WIRE BETWEEN BOXES. FLUSH - MOUNTED SINGLE -GANG JUNCTION BOX W/ I ISV, 20A SINGLE RECEPTACLE. 1 O�„ O.C. SEC FASTEN HIGH GRADE PLYWOOD SUPPORT TO ADJACENT FRAMING FLUSH- MOUNTED SINGLE -GANG JUNCTION BOX W/ 220V, 25A SINGLE RECEPTACLE (OPTIONAL,VERIFY WITH HENRY SCHEIN EQUIPMENT REP). PAN UNIT WALL BRACKET (TYP.) VERIFY HEIGHT DOES NOT ENCROACH ON ELECTRICAL. 5 /8" GYP. BRD. BOTH SIDES SEE MANUFACTURER'S INSTALLATION TEMPLATE FOR MORE DETAIL. X -RAY SUPPORT WALLS TO BE FRAMED WITH 16" (MAX) O.C. STUDS EXCEPT AT PAN LOCATION IN ORDER TO PROVIDE PROPER WALL SUPPORT & ELIMINATE MOVEMENT. MOUNTING MATERIALS SUPPLIED AND INSTALLED BY CONTRACTOR. PAN X -RAY NOT TO SCALE UJ w Z w Z N J Om U J b, v7 00 w=,,� J Z o� U w O o 3: ao HENRY SCHEIN REP: JOHN TURNER CENTER: WEST PALM BEACH_ PHONE #: 800 645 -6594 w 0i00p4 O O •� >- a LL w= i >_ wry 0 u Lu 24K a_Oxw u- ��WWW:E —w N � a_LU � w >- Uwv0Q > z O � Q V w p w Lu i Q F— O p w OZ 0 Z W� Q 62 •r <0 ©7N(a w- QF- Za=0 Za_Qwa--C,�s©r- w w w � Z cx p oe w u� U w u,� w ¢ > ~ 7 �w ❑1�0�Q'¢� - wZwZOZU�n `t0<0w0 zUU <no44 r> — ZLj vi wwZQF — ' � .�C7z0Z < N w O Z Q — — V) Z v) v) Q> w a'w� 0— wry- -� " ly z " CL DRAWING NAME: SOUTHMIAMI -F PROJECT START DATE: 07/02/2013 FINALS START DATE: 09/10/2013 _ DRAWN BY: OTHERS FINALS BY: TAS CHECKED BY: JBK REVISIONS: z o r) w V) F INT.SQ.FT.= BY OTHERS c)V) cv`1 NIIw a LLL_ Lij V) it Z F- V) O Lo 0 O 0 � 0 J HENRY SCHEIN REP: JOHN TURNER CENTER: WEST PALM BEACH_ PHONE #: 800 645 -6594 w 0i00p4 O O •� >- a LL w= i >_ wry 0 u Lu 24K a_Oxw u- ��WWW:E —w N � a_LU � w >- Uwv0Q > z O � Q V w p w Lu i Q F— O p w OZ 0 Z W� Q 62 •r <0 ©7N(a w- QF- Za=0 Za_Qwa--C,�s©r- w w w � Z cx p oe w u� U w u,� w ¢ > ~ 7 �w ❑1�0�Q'¢� - wZwZOZU�n `t0<0w0 zUU <no44 r> — ZLj vi wwZQF — ' � .�C7z0Z < N w O Z Q — — V) Z v) v) Q> w a'w� 0— wry- -� " ly z " CL DRAWING NAME: SOUTHMIAMI -F PROJECT START DATE: 07/02/2013 FINALS START DATE: 09/10/2013 _ DRAWN BY: OTHERS FINALS BY: TAS CHECKED BY: JBK REVISIONS: INT.SQ.FT.= BY OTHERS SCALE: SHT, SIZE: 3/4 " =1' -0" p C OoNF 3rinu- 0T 00 Z r LL s U ar i LL c <11 0 r