Loading...
13-1218-026GENERAL_ PLUMBING NOTES 1. A. ALL WORK SHALL. BE DONE in accordance with the 2.010 Florida Building Code and with all applicable regulations. B. DRAWINGS: Refer to all drawings for coordination of the plumbing work. C. ARRANGE AND PAY for all permits, licenses, inspections and tests. Obtain the required certificates and present to owner. D. GUARANTEE: The completed installation shall be fully guaranteed against defective materials and /or improper workmanship for a minimum of one year for material and labor. E. ALL HORIZONTAL SANITARY PIPING shall slope at 1/8 inch per foot minimum for 3" and larger and at 1/4" slope for 2 1/2" pipes and smaller. F. ALL materials shall be new, free of defects and correctly labeled with their appropriate listing agency. 2. SHOP DRAWINGS: Contractor shall submit for approval, within 30 days of signing contract, a minimum Of five Copies of fully descriptive literature, including but not limited to: water heaters, and plumbing fixtures. No work shall proceed without the approval of these submittals. 1 PLUMBING FIXTURES: Fixtures shall be as selected by owner and shall be furnished and installed by this contractor. Fixtures shall be complete with drains, traps, supplies and any other accessory required. Fixtures and faucets shall comply with the FBC Water saving standards. 4. MATERIALS: A. PIPING: a. Soil, waste and vent, and storm: Sanitary pipe, Cast Iron under ground, Schedule 40 above ground, All no HUB connections shall be with cast iron coupling. All piping in return plenurns shall be cast iron. b. Domestic water: CPVC pipe and fittings. c. Domestic water supply assembly: Chrome finish tubing with angle shut off valves in exposed areas. d. P &T Relief lines: CPVC pipe and fittings e. Drain Pan lines: DWV PVC pipe and fittings. f. Insulated all hot water and condensate drain piping. 5. PIPING TEST AND DISINFECTION& A. Test: All sanitary and domestic water supply piping shall be tested for leaks before piping is concealed or connected to equipment and plumbing fixtures. B. Disinfection: All domestic Water piping shall be disinfected by introducing a solution of calcium hypochlorite of 50 parts per million of chloride and as per AWWA Standards. 6. VALVES: Domestic water valves shall be of bronze body, sweat ends. 7. CONTRACTOR SHALL COORDINATE exact location of all plumbing system piping before starting any Work. Notify Architect /Engineer of any deviations from design drawings. 8. CONTRACTOR SHALL provide all necessary labor and materials for a complete "turn —key" plumbing system. 9. CONTRACTOR SHALL keep accurate as —built dwgs, on the field and provide them to owner once the job is complete. 10. CONTRACTOR SHALL familiarize himself with job site and with all construction documents including architectural, electrical, HVAC, and structural dwgs, prior to bidding. Adjustments in the plumbing system to accomodate other disciplines should be expected, and shall not represent additional costs to owner. Notify Architect /Engineer of any discrepancies prior to commencement of work. 11. Provide wall cleanouts at the base of every stack. 12. CONTRACTOR SHALL obtain insurance to protect against public liability and property damage for the duration of work. 13. CONTRACTOR SHALL use dimensions in architectural drawings to rough —in plumbing work. PLUMBING SYMBOL LEGEND - - - - -- -- .._- .._ ..... SYMBOL ......... _....____ -- DESCRIPTION ^^^ ---- SANITARY LINE — — - VENT LINE SD STORM DRAIN LINE - SAFEWASTE LINE CD CONDENSATE LINE { -- GATE VALVE — COLD WATER LINE - - HOT WATER LINE P- PLUMBING FIXTURE DESIGNA11ON AAV AIR ADMITANCE VALVE FCO FLOOR CLEAN OUT C.I� FLOOR PENETRATION 1.50 MECHANICAL SHOCK _ —� ARRESIOR WCO WALL. CLEANOUT VTR VENT THRU ROOF COVER SECURED WITH SCREWS THREADED C,O, PLUG rrni rnnnr 4 X 6" DIA. CONCRETE PAD FLUSH W /FIN, GRADE MAXIMUM FLOW RATES AND CONSUMPTION TABLE 604.4 PLUMBING FIXTURE FLOW RATE FLOW PRESSURE OR FIXTURE FITTING (gprn) (psi) LAVATORY, PRIVATE 1.0 60 LAVATORY, PUBLIC, (METERING) 0.25 gallon AS PER ARCHITECTURAL LAVATORY per metering - - -- 1/2" cycle AS PER ARCIIIIECTURAL LAVATORY, PUBLIC, (OTHER THAN METERING) 0.50 60 SHOWER HFAD 1.50 80 SINK FAUCET 1.50 60 WATER CI.. -OSET 1.28 gallons per AS PER ARCHITECTURAL HAND SINK flushing cycle 2" DISHWASHER (RESIDENTIAL) 6.5 gals. per cycle or AS PER ARCHIIEC1URAL less (energy star /water - - -- cn sense certified) WASHING MACHINES water factor of 8 or lower E (energy star /water sense - - -- a certified) TYPICAL CL.EANOUT DETAIL I SLIP JOINT EXTERIOR TYPE F-1 FI FI R WAI_L FACE_ OF WALL STAINLESS STEEL COVER SCREWLD TO THREADED C,O, PLUG, PLUMBING FIXTURE CONNECTION SCHEDULE DESCRIPTION WASTE VENT WATER REMARKS COLD HOT TANK WATER CLOSET 3" - -- 1/2" - -- AS PER ARCHITECTURAL LAVATORY 2" 2" 1/2" 1/2" AS PER ARCIIIIECTURAL SHOWER 2" - -- 1/2" 1/2" AS PER ARCLIIIECTURAL KITCHEN SINK 2" 2" 1/2" 1/2" AS PER ARCHITECTURAL HAND SINK 2" 2" 1/2" 1/2" AS PER ARCHIIEC1URAL cn NOTES: 1.— All exposed trim, such as P— traps, angle stops, and supplies shall be chrome plated. 2. - -- All fixtures shall comply with Reference Standards as per 2010 FBC Plumbing 406 through 421. SHUT-OFF - VALVE (opt. 112" H 12" CW SHUT -OFF VALVE (opt.) INSTANTANEOUS WATER HEATER X11 S WATER HEATER NOTES MODEL MAX, 0V AT 22ov VOLTS AT 220VP5 MANUFACTURER PIPE ITTTING _ -_ Lf _ –N -85 — 1.5 220 39 TITAN –SCR2 112" .98 E- mail: PROJEC'I'SOGULIRRER000N CA# 0007612 M a AUTOMATIC PRIMER VALVE WITH INTEGRAL VACUUM BREAKER /-- DOMESTIC WATER LINE 1/2" LINE TO TRAP FLOOR DRAIN DRAIN TO SEWER LINE FLOOR DRAIN RESEAL. NTS JOB #: 013 -051 GUERRERO /GONZAI ENGINEERS, INC. t0l; Michnel C. Guerrero, P.E Irge f., Mechanical Eng. Lic. #15235 Rafael L. Gonzalez, P.E. r ^ Electrical EnJ- Lic. #11057 740 TAMIAMI CANAL R0.'` Miaml, Horida 33144 Tel. (305) 262 -3JA4, Fax (305), E- mail: PROJEC'I'SOGULIRRER000N CA# 0007612 M LanMar DESIGN GROUP Architecture Planning 2450 Southwest 137th Avenue Suite #212 Miami, Florida 33175 305.226.1340 Fl. registration: AA:26- 001927 IB :26- 001183 LU U U_ Li- 110 Fol rA- Z 0 V) Seal: Rey Martinez, Architect AR 11555 Revisions: No. Date Dept /Section By 4 5 R. "'; w Date: ° Scale: Job No. (. J Drawn by: x� t�y Chocked by: 07.15.13 As Shown 13 -1007 I_�•J 41) CN M a 00 � o U-11 cn Ln E Imo. a , L Z) O Fol rA- Z 0 V) Seal: Rey Martinez, Architect AR 11555 Revisions: No. Date Dept /Section By 4 5 R. "'; w Date: ° Scale: Job No. (. J Drawn by: x� t�y Chocked by: 07.15.13 As Shown 13 -1007 I_�•J