13-1103R-005
0.. f uu. PLUMBING GENERAL NOTES: 1. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY FOR THE INSTALLATION OF A COMPLETE PLUMBING SYSTEM IN ACCORDANCE WITH THESE DRAWINGS, THE FLORIDA BUILDING CODE 2010 AND ADDENDUMS, ALL OTHER APPLICABLE STATE, COUNTY AND LOCAL CODES AND ORDINANCES. 2. THE CONTRACTOR SHALL PAY ALL COSTS OF PERMIT, INSPECTIONS AND ALL OTHER COSTS INCIDENTAL TO THE COMPLETION AND TESTING OF THIS WORK. UPON FINAL ACCEPTANCE, A CERTIFICATE FROM THE LOCAL INSPECTION AUTHORITY SHALL BE FURNISHED TO THE OWNER. 3. ALL MATERIALS AND EQUIPMENTS SHALL BE NEW, OF U.S. MANUFACTURER AND OF GOOD QUALITY OF RESPECTIVE KIND AND GRADE, AND MUST BE FURNISHED SO AS TO PREVENT ANY DELAY IN THE PROGRESS OF THE WORK. ALL WORK THROUGHOUT SHALL BE PERFORMED IN A WORKMANLIKE MANNER BY SUFFICIENT NUMBER OF SKILLED WORKMEN. 4. CONTRACTOR SHALL VISIT THE SITE AND REVIEW ALL PERTINENT UTILITY DRAWINGS TO FAMILIARIZE HIMSELF WITH THE LOCATION OF ALL EXISTING AND /OR PROPOSED UTILITY STUB OUTS, PIPING, INVERT, EQUIPMENT, ETC., AND MAKE DUE ALLOWANCES FOR ANY CONDITION AFFECTING HIS WORK. 5. THE LOCATION OF ALL ITEMS SHOWN ON THE DRAWINGS ARE NOT DEFINITELY FIXED BY DIMENSIONS ARE APPROXIMATE ONLY.THE EXACT LOCATIONS NECESSARY TO SECURE THE BEST CONDITIONS AND RESULTS MUST BE DETERMINED BY THE CONTRACTOR AT THE PROJECT AND SHALL BE APPROVAL BEFORE ACTUAL INSTALLATION. 6. ALL PLUMBING LINES SHOWN ARE IN THE APPROXIMATE LOCATION ONLY. FINAL PLUMBING LINES EXACT LOCATION WILL BE DETERMINE AT PROJECT SITE IN RESPONSE TO FIELD CONDITIONS. 7. ALL CUTTING REQUIRED TO PERFORM THE WORK UNDER THIS CONTRACT WILL BE DONE BY MECHANICAL CONTRACTOR. ANY CUTTING OF STRUCTURE MUST BE APPROVED BY STRUCTURAL ENGINEER PRIOR TO EXECUTION OF WORK. 8. GENERAL CONTRACTOR TO COORDINATE LOCATIONS AND SIZES OF ALL ACCESS DOORS WITH ARCHITECTURAL DRAWINGS. 9. INSTALL CONCRETE SUPPORT AT BASE (UNDERGROUND CONNECTION) OF SOIL STACK, RAIN LEADER, ETC. 10. ALL SANITARY DRAINAGE PIPING AND FITTINGS SHALL BE SCH. 40 PVC PIPE. EXCEPT WHEN IN PLENUM SPACES ALL PIPING TO COMPLY WITH TABLE 702.1 AND 702.2 FBC (PLUMBING). 11. ALL STORM PIPING AND FITTING SHALL BE SCH. 40 PVC. PIPING TO COMPLY WITH TABLE 702.1 AND 702.2 FBC (PLUMBING) EXCEPT WHEN IN PLENUM SPACES 12. ALL ABOVE GROUND WATER PIPING SHALL BE COPPER TYPE "L" PIPING TO COMPLY WITH TABLE 605.5 FBC (PLUMBING). 13. ALL HOT WATER PRESSURE AND TEMPERATURE RELIEF PIPING SHALL BE COPPER TYPE "K" (ASTM B -306). 14. CONDENSATE DRAIN PIPING SHALL BE SCH 40 PVC PIPE INSULATED WITH 1" ARMAFLEX. EXCEPT WHEN IN PLENUM SPACES. 15. ALL PLUMBING FIXTURES SHALL BE PROVIDED WITH ALL NECESSARY ACCESSORIES SUCH AS STOP VALVES, "P" TRAPS, SUPPORTS, P & T VALVES, ETC., AS REQUIRED. ALL EXPOSED PIPING AT FIXTURES AND EQUIPMENT SHALL BE CHROME PLATED BRASS PIPE OR TUBE. PROVIDE SHUT OFF VALVES AND UNIONS TO ALL FIXTURES, ETC., REQUIRING WATER SUPPLY. PROVIDE DIELECTRIC COUPLINGS AS REQUIRED. FOR ALL COPPER PIPING CONTRACTOR MUST USE 95/5 SOLDER. PROVIDE WATER HAMMER ARRESTORS TO EACH FIXTURE AS REQUIRED. 16. PROVIDE CLEANOUTS (WITH CHROME PLATED WALL OR FLOOR ACCESS FRAMES AND COVERS AS REQUIRED) AT THE BASE OF ALL WASTE AND /OR VENT STACKS. PROVIDE PITCH PANS & LEAD FLASHING FOR ALL SANITARY SYSTEM VENTS. 17. ALL HORIZONTAL WASTE PIPING 3" AND LARGER SHALL BE SLOPPED AT 1/8 PER FOOT. 18. ALL 2" HORIZONTAL WASTE PIPING SHALL BE SLOPPED AT 1/4 PER FOOT. 19. ALL UNDERGROUND PIPING IS TO BE HUNG FROM THE SLAB. 20. ALL POTABLE WATER USE FIXTURES SHALL COMPLY WITH "NO -LEAD" REQUIREMENTS. 21. ALL FIXTURES SUPPLIES AND STOPS SHALL BE CHROME PLATED (C.P.) 22. ALL EXPOSED FIXTURE "P- TRAPS" SHALL BE MINIMUM 17 GAL. & CHROME PLATED CAST BRASS OR 316 STAINLESS STEEL. 23. PROVIDE ANTI - SCALDING VALVE • 110 OF ON ALL TUBS AND SHOWERS. OF THE THERMOSTATIC AND PRESSURE BALANCED TYPE ( ASSE 1016). FINISHED OR COLUI ACCESS I DOOR SECTION ITEE C.O. W/ BRONZE COUNTER SUNK PLUG PLUMBING LEGEND LEGEND DESCRIPTION - - - - - `-' - - - EXISTING COLD WATER LINE _ _ _ _ _ _ _ _ _ EXISTING SANITARY LINE - - COLD WATER LINE -- _ GATE VALVE " SANITARY LINE - ^- ._.._ - - --_. VENT LINE --- CONDENSTATE LINE Z POINT OF CONNECTION - - TO EXISTING LINE CO I CLEAN -OUT CW COLD WATER V VENT J PLUMBING SCOPE AND NOTES: 1. SCOPE OF WORK INCLUDES THIS TENANT REMODELING IN THIS EXISTING BUILDING AS SHOWN ON PLANS. 2. BEFORE COMMENCING WORK CONTRACTOR SHALL VERIFY CEILING SPACE AND COORDINATE WITH MECHANICAL AND ELECTRICAL CONTRACTORS TO AVOID SPACE CONFLICTS. 3. PROVIDE A REFRIGERATOR AND SINK AS SHOWN ON PLANS. 4. PROVIDE HAMMER WATER ARRESTORS IN QUICK - CLOSING VALVE FIXTURE CONNECTIONS AS PER FPC 604.9 5. NO PLUMBING PIPING SHALL BE RUN ABOVE ELECTRICAL EQUIPMENT, RELOCATE ANY EXISTING PIPING AS REQUIRED, COORDINATE WITH ELECTRICAL CONTRACTOR. 6. PROVIDE VALVING AND ALL COMPONENTS AS REQUIRED FOR A COMPLETE OPERATIONAL SYSTEM. 7. WORK SHALL COMPLY WITH FBC 2010 AND ADDENDUMS. 8. CONTRACTOR TO VERIFY FINAL FIXTURE SELECTION WITH OWNER BEFORE COMMENCING WORK. PLUMBING FIXTURE CONNECTION SCHEDULE MARK DESCRIPTION WASTE VENT C.W H.W REMARKS /SPECS ASSE 1010 • " 1 2" „ U R REFRIGERATOR - -• 1/2- CONNECTION -•- WALL MOUNTED BOX WITH VALVE AND FLEX C NN 1. MAXIMUM FLOW RATES AND CONSUMPTION OF PLUMBING FIXTURES S R MIAMI -DADE ORDINANCE 8 -14 (CODE 8 -31). AS PER MIAMI DADE COUNTY AMMENDMENT TO FBC P604.4 2. FAUCETS AND FIXTURE FITTINGS WITH HOSE - CONNECTED OUTLETS SHALL CONFORM TO ASME A112.18.3M AS PER FPC 424.4, 3. ALL FIXTURES SHALL COMPLY WITH STANDARDS AS PER FBC P406 THROUGH 421. WATER HAMMER ARRESTER SPECS. P.D.I. UNITS F.U. RATING CATALOG NO. MANUFACTURER STANDARDS A 1 - 11 5005 J. R. SMITH ASSE 1010 TEE CLEANOUT DETAIL NTS ISOMETRIC FINISHED WALL OR COLUMN EXISTING 3" SAN VERIFY LOCATION E�IS�,G SANITARY LINES SLOPE: LESS THAN 3 ": 1 /4 "/LF 3" AND GREATER: 1 /8 " /LF ,r. 3 i1• ••• • • b r • V r l] • i • • • EXISTING 1" CW 2 "VENT TO CONNECT WITH EXISTING VENT LINE SANITARY RISER N.T.S 2 Plumbin 5 Scale: A" = V -O" Floor Plan 0' it 5 0 10' 15' mho$ � I EXISTING 1" CW VERIFY LOCATION G 5XI5��-_1 oll WATER RISER N.T.S U I �^ I 5. INTERIOR MODIFICATIONS Or(ANYEXTE[Uopt MO1}1 }"TlrA BOARD APP' ya 1tE lANCE) u • • Y • • • •KAFAEC 1Y. °BAL`LESTEROS, ARCHITECT 7431 SW 88 PLACE MIAMI, FLORDIA 33173 TEL. (305) 275 -0016 I FAX (305) 275 -0018 CELL (305) 790 -1996 FLORIDA REGISTRATION # AR0016490 CONSULTANT: (_0 r E a) Co CO 0 r U _ Co Z _j 05 . o° > � Q z' 0X Ck: LL LU w LU 06 _Z Z LU Co tv Lo 0 N T i/) N a) -2 CV Co 0 M 2 u� Ln z ©- N co co CD m E so F- 0) U ............................................................................................. ............................... U 00 C � � CY) d U) M r J I � w w 0L U) > 0 w U� p U_ LL 0 w Q 0 ►z- p OC Lo �- aw0 0 2 LjL Lo 0 W ISSUE DATE .__..._ _...__.... ...... ..... ._...... -- ... - _._...W...._ ._...�_._ PERMIT SET 9 -27 -13 © OWNER REV 04/14/14 i3 PROJECT NO. 2013- 5975 -01 { DATE: 9 -27 -13 CADD FILE: DRAWN: S. C CHECKED: P.V SEAL: i P, ABLO J. VITERI PELF 59535 SHEET TITLE: Plumbing Plan SHEET: I OF SHEETS •y • J {i