13-1103R-002
GENERAL ELECTRICAL NOTE 1. ALL WORK SHALL CONFORM WITH ALL LOCAL, STATE, FEDERAL ORDINANCES, FLORIDA BUILDING CODE 2010 AND ADDENDUMS, NEC 2008, GOVERNING THE INSTALLATION OF THE ELECTRICAL SYSTEM. IF WORK AS LAID OUT, INDICATED OR SPECIFIED IS CONTRARY TO OR CONFLICTS WITH LOCAL ORDINANCES, BUILDING CODES AND REGULATIONS,THE CONTRACTOR SHALL REPORT IN WRITING TO THE ARCHITECT/ENGINEER BEFORE SUBMITTING A BID. THE ARCHITECT /ENGINEER WILL THEN ISSUE INSTRUCTIONS AS HOW TO PROCEED. 2. THE DRAWING ARE TO BE CONSIDERED DIAGRAMMATIC, NOT NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE MINOR ITEMS. UNLESS SHOWING IN DETAIL OR TO SCALE ALL OF THE MINOR ITEMS, UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE STRUCTURAL, ARCHITECTURAL AND SITE CONDITIONS SHALL GOVERN THE EXACT LOCATIONS. CONTRACTOR SHALL FOLLOW DRAWINGS IN LAYING OUT WORK, CHECK DRAWINGS OF ALL TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED AND MAINTAIN MAXIMUM HEAD ROOM, OR SPACE CONDITIONS AT ALL POINTS. WHERE HEADROOM, OR SPACE CONDITIONS APPEAR INADEQUATE, ARCHITECT/ENGINEER SHALL BE NOTIFIED BEFORE PROCEEDING WITH INSTALLATION. THIS CONTRACTOR SHALL, WITHOUT EXTRA CHARGE, MAKE FIELD MODIFICATION IN LAYOUT AS NEEDED TO PREVENT CONFLICT WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION OF THE WORK. 3. INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST CLASS WORKMANLIKE MANNER. THE OWNER RESERVES THE RIGHT TO DIRECT REMOVAL AND REPLACEMENT OF ITEMS WHICH, IN HIS OPINION, DO NOT PRESENT A NEAT AND WORKMANLIKE APPEARANCE. REMOVAL AND REPLACEMENT IS TO BE DONE IMMEDIATELY WHEN DIRECTED BY THE OWNER IN WRITING, AT THE SOLE EXPENSE OF CONTRACTOR. 4. START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS AS TO SUITABILITY OF THE WORK OF OTHER TRADES OR OTHER CONTRACTORS TO RECEIVE HIS WORK. THIS CONTRACTOR SHALL REMOVE AND REPLACE, AT HIS EXPENSE, ALL ELECTRICAL WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF INTERFERENCE WITH OTHER TRADES. 5. THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE, FEES, PERMITS ASSOCIATION DUES, ROYALTIES, AND TAXES OF WHATEVER NATURE SHALL APPLY TO THIS WORK. HE SHALL ALSO PAY ALL INSPECTION FEES AS MAY BE REQUIRED BY LAW OR ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF THE LAWS, RULES OR ORDINANCES. 6. ALL WIRE COPPER, IN RACEWAY, UNLESS OTHERWISE SPECIFIED ON DRAWINGS. 7. PROVIDE MEANS "FURNISH AND INSTALL ". S. COORDINATE WORK WITH WORK OF OTHER TRADES TO AVOID ALL CONFLICTS. 9. PROVIDE A COMPLETE OPERATIONAL SYSTEM, EVERYTHING CONNECTED, READY FOR USE. 10. PROVIDE ALL WIRING DEVICES. AVOID 1/2 SIZE BREAKERS UNLESS APPROVED BY ENGINEER. 11. PRIOR TO CIRCUITING HOMERUNS, CONTRACTOR SHALL FIELD VERIFY EXISTING LOADS, SPARES, SPACES, AVAILABILITY, AND WIRE ACOORDINGLY. IDENTIFY CLEARLY ON A TYPE WRITTEN PANEL SCHEDULE ALL CIRCUITS TO CORRESPOND WITH EXISTING, AND NEW CONDITIONS. ATTACH INSIDE THE PERTAINING PANEL DOOR. 12. RACEWAYS: ALL UNDERGROUND RACEWAYS TO BE PVC, INSIDE CONCRETE SLAB EMT WITH APPROVED SET SCREW FITTING, INSIDE PARTITION EMT, AND, ENT WHERE ALLOWED. FOR FLOOR PENETRATION USE ONLY EMT. 13. SHOP DRAWINGSJHIS CONTRACTOR SHALL FURNISH THE ENGINEER WITH SHOP DRAWINGS OF EQUIPMENT PRIOR TO PURCHASE FOR APPROVAL. 14. TESTING: THE CONTRACTOR SHALL TEST ALL WORK AND EQUIPMENT AS DIRECTED BY THE ARCHITECT AND BY AUTHORITIES HAVING JURISDICTION,FURNISHING ALL EQUIPMENT AND NECESSARY PERSONNEL AND ELECTRIC POWER. THE ENTIRE INSTALLATION SHALL BE TESTED FOR SHORTS, GROUNDS AND OPEN CIRCUITS, AND ALL DEFECTS SHALL BE DEMONSTRATED TO BE IN PROPER WORKING AND OPERATING CONDITION TO THE COMPLETE SATISFACTION OF THE ENGINEER. 15. gUARANTEES: ONE YEAR AFTER THE DATE OF ACCEPTANCE BY OWNER. 16. AT COMPLETION OF PROJECT THE ELECTRICAL CONTRACTOR SHALL GIVE THE OWNER AN AS -BUILT SET OF DRAWINGS SHOWING THE EXACT ELECTRICAL INSTALLATION. ALL EQUIPMENT AND MATERIALS SHALL BE GUARANTEED FOR. 17. BEFORE BIDDING THE JOB THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH ALL EXISTING CONDITIONS. 18. ALL EXISTING ELECTRICAL DEVICES AND EQUIPMENT AND THEIR ASSOCIATED WIRING INSIDE THE REMOVED WALLS SHALL BE DISCONNECTED AND REMOVED. 19. CONTRACTOR SHALL COLOR CODE THE FEEDER, AND BRANCH WIRING AS FOLLOWS: 120/24OV: BLACK, RED, BLUE, AND WHITE. 20. CONTRACTOR SHALL FIRE -STOP AND SEAL ALL PATHWAYS THROUGH FLOORS, WALLS, AND OTHER RELATED PENETRATIONS IN ACCORDANCE WITH FBC. TYPE: SERVICE: VOLTAGE: MOUNTING: LOAD CENTER 3P -4W 120/208V SURFACE REMARKS c c > PANEL B > MIN 10 KAIC TRIP MAIN BUS: NEUTRAL: MAINS: LOCATION: 100A 100A MLO TOP CKT No CKT No 2 4 6 8 10 12 14 16 18 20 t26 28 30 32 34 36 38 40 42 REMARKS POL ES TRIP CON DUIT WIRE KVA CKT No 2 4 G 8 10 12 4 16 18 20 1 r REMARKS POL ES TRIP CON DUIT WIRE KVA 1 LIGHTING 1 20 1/7" #12 1.2 SHOW WINDOW 1 20 1/2" #12 1.2 3 SIGN LTG VIA T/C CB 1 .off L `v ot x �L N LL RECEPTACLES Lu METER 5 GFI- BATHROOM EXISTING I "MDPA" 5 L J 1.0 Ij (PANEL I I t 1.0 N a) I 100A 2000 I 7 RECEPTACLES 1.0 7 RECEPTACLES r) _ � 0 Cz I 1.0 J 80 I-- a) U . AHU -2 2 20 1/2" #12 4.0 9 - 2 30 3/4" #10 10 .2 10.1 CU -1 2 20 J W 11 11 0 WW SPACE I ! W O i 13 SPACE EWC'S 1 20 117" #12 1.0 SIGN LTG VIA T/C 1 20 1/2" #12 1.2 15 SHOW WINDOW ❑ U❑ WW1- z ❑ �/ Lo F- 0 o Q ❑ PANEL "B" 2 50 17 #8 12.0 17 TV 1 20 © OWNER REV 04/14/14 19 19 SPACE SPACE i PROJECT N0. 2013- 5975 -01 I DATE: 9 -27 -13 CADD FILE: 21 DRAWN: S.0 TOTAL 4.4 j SEAL: TOTAL 7.6 TOTAL CONNECTED LOAD = 12.OKVA = 34AMPS 23 T L O 4 3 TYPE: LOAD CENTER EXISTING MAIN BUS: 150A SERVICE: 3P -4W c c " NEUTRAL: 150A VOLTAGE: 120/208V PANEL A MAINS: MLO MOUNTING: SURFACE MIN 10 KAIC LOCATION: TOP CKT No REMARKS POL ES TRIP CON DUIT WIRE KVA CKT No 2 4 6 8 10 12 14 16 18 20 t26 28 30 32 34 36 38 40 42 REMARKS POL ES TRIP CON DUIT WIRE KVA 1 LIGHTING BATHROOM 1 20 117" #12 1.2 RECEPTACLES 1 20 1/2" #12 1.0 3 LIGHTING PUBLIC I M _j CO N LL Co > w' CB 1 .off L `v ot x �L N LL Lu METER 5 GFI- BATHROOM EXISTING I "MDPA" SPACE 104 L J 1.0 Ij (PANEL I I t PANEL "B" N a) I 100A 2000 I 7 RECEPTACLES 'n c U-) Z - N r) _ � 0 Cz I 1.0 J 80 I-- a) U UQ 9 AHU -1 2 40 10.1 CU -1 2 20 J W 5.1 11 0 WW I ! W O i U _.. (n 13 EWC'S 1 20 117" #12 1.0 SIGN LTG VIA T/C 1 20 1/2" #12 1.2 15 SHOW WINDOW ❑ U❑ WW1- z ❑ �/ Lo F- 0 o Q ❑ PANEL "B" 2 50 3/4„ #8 12.0 17 TV 1 20 © OWNER REV 04/14/14 19 SPACE SPACE i PROJECT N0. 2013- 5975 -01 I DATE: 9 -27 -13 CADD FILE: 21 DRAWN: S.0 CHECKED: P V j SEAL: w 23 u PABLO J. VITERI 25 SHEET TITLE: Electrical Power Riser & Notes, SHEET. I E -2 27 OF SHEETS 29 31 33 35 37 39 41 TOTAL 17.5 TOTAL 17.2 TOTAL CONNECTED LOAD = 34.7KVA = 96AMPS Q UNLESS OTHERWISE NOTED ALL TO CKTS ARE EXISTING TO REMAIN. !� EXISTING NON- CONCIDENTAL A/C LOAD REWIRE EXISTING CKT°S AS SHOWN. O4 PROVIDE NEW CBS AND WIRING AS SHOWN EXISTING ELECTRICAL RM SPACE 104 EXISTING POWER RISER IS SHOWN FOR REFERENCE ONLY LEGEND I - - - - - EXISTING NEW •r• • r Y • u ••• ••• Y • ••r e Y • Y • • • Y Y�• i • Y • rrU• • • lile 4 INTERIOR MODIFICATIONS ONI.V (ANY EXTERIOR MODIFICATION MAY REQUIRE A BOARD APPEARANCE) • U ••••• • V • r U I RAFAEL D. BALLESTEROS, ARCHITECT 3 #8 Jc #10 PLACE I MIAMI, FLORDIA 33173 GND IN 1 "C I FAX (305) 275 -0018 EXISTING PANEL "A" 790 -1996 FLORIDA REGISTRATION # AR0016490 CONSULTANT: CB I E I M _j CO N LL Co > w' CB re ,. y�0 V .off L `v ot x �L N LL Lu METER EXISTING I "MDPA" SPACE 104 L J Ij (PANEL I I t PANEL "B" N a) I 100A 2000 I I M r O a) 'n c U-) Z - N r) _ � 0 Cz I , m (D E J 80 I-- a) U UQ EXISTING POWER RISER IS SHOWN FOR REFERENCE ONLY LEGEND I - - - - - EXISTING NEW •r• • r Y • u ••• ••• Y • ••r e Y • Y • • • Y Y�• i • Y • rrU• • • lile 4 INTERIOR MODIFICATIONS ONI.V (ANY EXTERIOR MODIFICATION MAY REQUIRE A BOARD APPEARANCE) • U ••••• • V • r U • r a RAFAEL D. BALLESTEROS, ARCHITECT 7431 SW 88 PLACE MIAMI, FLORDIA 33173 TEL. (305) 275 -0016 FAX (305) 275 -0018 CELL (305) 790 -1996 FLORIDA REGISTRATION # AR0016490 CONSULTANT: E \.J .. M _j CO N LL Co > w' Q re ,. y�0 V .off L `v ot x �L N LL Lu LL! .$ _Z z Ij o E k N N a) Q� wwyww M r O a) 'n c U-) Z - N r) _ � 0 Cz , m (D E 80 I-- a) U UQ (y) C Q C') CY) J W 0 ❑ 0 WW I ! W O i U _.. (n 0 LL Z � O fn 4 .J z 4 ❑ U❑ WW1- z ❑ �/ Lo F- 0 o Q ❑ 0 IL 5 LL Lo V) U) ISSUE DATE PERMIT SET 9 -27 -13 © OWNER REV 04/14/14 i PROJECT N0. 2013- 5975 -01 I DATE: 9 -27 -13 CADD FILE: DRAWN: S.0 CHECKED: P V j SEAL: w u PABLO J. VITERI PE# 59535 SHEET TITLE: Electrical Power Riser & Notes, SHEET. I E -2 OF SHEETS