13-1103-012
DX SPLIT SYSTEM SCHEDULE UNIT DESIGNATION AHU -2 LOCATION CEILING AREA SERVICE PHARMACY UNIT TYPE HORIZONTAL NOMINAL TONS 2.0 EER /SEER 13.85/16.0 OUTSIDE AIR (CFM) 160 OUTSIDE ENTERING AIR TEMP.( -F) SUMMER /WINTER 80'DB /67- WB /95-DB WEIGHT (LBS) 82 v TOTAL AIR, (CFM) 850 uw TYPE CENTRIFUGAL z EXTERNAL STATIC PRESSURE (IN. WC) 0.4" CD FAN MOTOR SIZE (HP) 1/3 SUPPLY CEILING DIFFUSER. CEILING MOUNTED MOTOR DRIVE TYPE DIRECT -w- © TOTAL CAPACITY, (MBH) 25,6 0 SENSIBLE CAPACITY, (MBH) 19.1 rz ENTERING AIR TEMPERATURE (DB/WB -F) 80.0/67.0 00 LEAVING AIR TEMPERATURE (DB /WB'F) -/- _ AIR PRESSURE DROP (MAX.) IN. WC - w TOTAL CAPACITY (MBH) - R.A.G. KW 3.0 = NO. OF HEATING STEPS 1 C.0 TYPE 1" TA RETURN AIR AREA (SF) - E.A EFFICIENCY (7.) MERV 8 ELECTRICAL SERVICE (V /PH/Hz) 208/1/60 MCA/MOCP 17/20 MANUFACTURER RHEEM MODEL NUMBER RHKL- HM2417JA DIMENSIONS INCHES (WxDxH) 17.5x21.6x42.5 UNIT DESIGNATION CU -2 LOCATION PLATFORM UNIT TYPE AIR COOLED SIDE DISCHARGE WEIGHT (LBS) 199.5 0: NUMBER /TYPE 1 oCAPACITY STEPS 1 0 RLA/LRA (EACH) 13.5/58.3 z TYPE PROPELLER DATE NUMBER 1 0 MOTOR (HP/FLA) -/1.1 0 DRIVE DIRECT REFRIGERANT 410 -A ELECTRICAL SERVICE (V /PH/Hz) 208/1/60 MCA/MOCP 18/30 MANUFACTURER RHEEM MODEL NUMBER RAMP- 024JEZ DIMENSIONS INCHES WxDxH) 44.301.5x29.0 NOTES AND ACCESORIES SEE BELOW): ALL BELOW 1. PROVIDE FACTORY MOUNTED CIRCUIT BREAKER. 2. PROVIDE PROGRAMMABLE THERMOSTAT ACCUSTAT ES -U 55 -80. 3. PROVIDE FACTORY INSTALLED HEATER. 4. REFRIGERANT LINES SHALL BE TYPE "L" SEAMLESS COPPER. INSULATE SUCTION LINE WITH ARMAFLEX 3/4-,ABOVE 50' USE MANUFACTURER'S CAPACITY MULTIPLIERS AND BALANCE LINE SIZING INSTRUCTIONS. H VAC LEGEND SYMBOL DESCRIPTION — - - — EXISTING SUPPLY DUCT, SIZE AS NOTED - - -- EXISTING RETURN DUCT, SIZE AS NOTED 12 x10 SUPPLY DUCT, SIZE AS NOTED 14'x8m RA RETURN DUCT, SIZE AS NOTED B "D EXH EXHAUST DUCT SIZE AS NOTED TIT'S 350 FL RIGID DUCT WITH MANUAL VOLUME DAMPER NECK SIZE TO MATCH DUCT SIZE 0 (MVD) BRANCH TAP AT SUPPLY NOTED ON PLANS CD FLEXIBLE DUCT WITH MANUAL VOLUME TYPE 1 (SURFACE), TYPE 3(LAY -IN) DI'D DAMPER (M.V.D.) BRANCH TAP AT ALUMINUM SUPPLY. CD 156 CFM W SUPPLY CEILING DIFFUSER. CEILING MOUNTED ®-" DISCHARGE PATTERN AS NOTED 1W. 2W, 3W, 4W -w- © RETURN AIR GRILL (RAG), CEILING MOUNTED R.A. E.G. EXHAUST AIR GRILL (EG) CEILING MOUNTED rz POINT OF CONNECTION - - -- TO EXISTING LINE OT PROGRAMMABLE THERMOSTAT _ REFRIGERANT LINES, SIZES AS - PER SCHEDULE o -czQ MANUAL VOLUME DAMPER R.A.G. RETURN AIR GRILL C.D. CEILING DIFFUSER A.H.0 AIR HANDLERS UNIT C.0 CONDENSING UNIT R.A. RETURN AIR M.V.D. MANUAL VOLUME DAMPER E.A EXHAUST AIR E.G EXHAUST GRILL B.D. BACK DRAFT DAMPER E EXISTING RL RELOCATED DN DN F/B FROM BELOW OH OVERHEAD SUPPLY AIR DISTRIBUTION SCHEDULE No. SYMBOL FACE OR CEILING BORDER TYPE MANUFACTURER MODEL No. CONSTRUCTION REMARK OB PA FO MODULE SIZE TYPE 1 SURFACE), TYPE 3(LAY -IN) TIT'S 350 FL ALUMINUM FINISH 26 (WHITE) NECK SIZE TO MATCH DUCT SIZE 0 FIRE STOPPING NOTED ON PLANS CD 24 "X24" OR AS TYPE 1 (SURFACE), TYPE 3(LAY -IN) TITUS TDCA -AA ALUMINUM NECK SIZE TO MATCH CFM'S PHARMACY 10P x 5CFM /P + 591SF x 0.18CFM /SF = 156 CFM W NOTED ON PLANS CEILING MOUNTED TOTAL PROVIDED 160CFM FINISH 26 (WHITE) DIFF O.B.D., AG -75, AG -95 RETURN AIR DISTRIBUTION SCHEDULE No. SYMBOL FACE OR CEILING MODULE SIZE BORDER TYPE MANUFACTURER MODEL No. CONSTRUCTION REMARK OB PA FO 24 0X24" OR AS TYPE 1 SURFACE), TYPE 3(LAY -IN) TIT'S 350 FL ALUMINUM FINISH 26 (WHITE) NECK SIZE TO MATCH DUCT SIZE • FIRE STOPPING NOTED ON PLANS CEILING MOUNTED SMOKE CONTROL AHU -2 • GRILL WITH BORDER, 314" SPACING MECHANICAL SCOPE OF WORK AND NOTES: 1. SCOPE OF WORK INCLUDES THIS TENANT REMODELING IN THIS EXISTING BUILDING AS SHOWN. COMPLY WITH FBC 2010 AND ADDENDUMS. 2. EXISTING SPACE BEING SERVED BY TWO AIR HANDLER UNITS, ONE EXISTING AHU -1 (4 TONS) TO REMAIN AND ADEQUATE TO HANDLE THIS REMODELING AND ANOTHER AHU -2 (2 TONS) TO SERVE PHARMACY SPACE. 3. NO COMBUSTIBLE MATERIALS ALLOWED IN CEILING RETURN PLENUM. 4. BEFORE COMMENCING WORK CONTRACTOR SHALL VERIFY EXISTING CONDITIONS. 5. CONTRACTOR TO COORDINATE WITH ARCH /CLIENT FOR FINAL DIFFUSER AND GRILL MANUFACTURER AND MODEL SELECTION. 6. REFER TO ARCHITECTURAL PLANS FOR CEILING TYPES, COORDINATE DUCTWORK WITH EXISTING CEILING CONDITIONS. 7. REFER TO GENERAL NOTES FOR ADDITIONAL DETAILS NO MEDICATION PREPARATION UNDER THESE PREMISES. HVAC DESIGN REQUIRES YES NO DUCT SMOKE DETECTOR ASHRAE STANDARD 62 -2004 • FIRE DAMPERS AHU -1 • SMOKE DAMPER(S) FLORIDA REGISTRATION # AR0016490 • FIRE RATED ENCLOSURE 15P x 5CFM /P + 927SF x 0.06CFM /SF = • FIRE RATED ROOF/FLOOR CEILING ASSEMBLY TOTAL REQUIRED = • FIRE STOPPING TOTAL PROVIDED 150CFM • SMOKE CONTROL AHU -2 • Ke Plan N 02 Nrs rammm 00000000000000 o\0000mmmm0000000 A--> TO CONNECT WITH TO CONNECT CU -2 IN 2ND FL. WITw FXISTIN(. PFFFR TC1 KFY PI ON FXICT 1 -HR AREA OF CU'S N 02 Mechanical Floor Plan Scale: %4" = 1' -0" r - --i r - --I SELL I I ML I (E) I I (E) I L---J L---J r - --1 SQL (E) L r - --T I Sal. I I (E I L r - - -T OUTSIDE AIR CALCULATIONS COMMENCING WORK CONTRACTOR ASHRAE STANDARD 62 -2004 ALL VERIFY EXISTING CONDITIONS FOR FAX (305) 275 -0018 AHU -1 INSTALLATION OF CU -2 9SEA FLORIDA REGISTRATION # AR0016490 REQUIRED SPACE 15P x 5CFM /P + 927SF x 0.06CFM /SF = 130 CFM TOTAL REQUIRED = 130 CFM _C C'') Z --I 00 C 00 TOTAL PROVIDED 150CFM U-j > j Q AHU -2 AffA REQUIRED PHARMACY 10P x 5CFM /P + 591SF x 0.18CFM /SF = 156 CFM W TOTAL REQUIRED = 156 CFM TOTAL PROVIDED 160CFM Ke Plan N 02 Nrs rammm 00000000000000 o\0000mmmm0000000 A--> TO CONNECT WITH TO CONNECT CU -2 IN 2ND FL. WITw FXISTIN(. PFFFR TC1 KFY PI ON FXICT 1 -HR AREA OF CU'S N 02 Mechanical Floor Plan Scale: %4" = 1' -0" r - --i r - --I SELL I I ML I (E) I I (E) I L---J L---J r - --1 SQL (E) L r - --T I Sal. I I (E I L r - - -T ML I (E) I L r - --I GLL L Condensing Unit Plan NTS (E L r - --I I Sal. I I (E I L_ -J CU-2 I (PLATFORM) I (E I L REF UNE F/B TO CONNECT WITH CU -2 I moommommo�0000 .\\\000000000000\00000000 \\\ \\ \\\\\\\\\ \ \ \ \O \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \\ • • • W. i DACACI n- DA11 CQ'�CDAC AD. LIITC.--T 7431 SW 88 PLACE 3E FORE COMMENCING WORK CONTRACTOR 3H ALL VERIFY EXISTING CONDITIONS FOR FAX (305) 275 -0018 INSTALLATION OF CU -2 ML I (E) I L r - --I GLL L Condensing Unit Plan NTS (E L r - --I I Sal. I I (E I L_ -J CU-2 I (PLATFORM) I (E I L REF UNE F/B TO CONNECT WITH CU -2 I moommommo�0000 .\\\000000000000\00000000 \\\ \\ \\\\\\\\\ \ \ \ \O \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \\ • • • W. i DACACI n- DA11 CQ'�CDAC AD. LIITC.--T 7431 SW 88 PLACE MIAMI, FLORDIA 33173 TEL (305) 275 -0016 FAX (305) 275 -0018 CELL (305) 790 -1996 FLORIDA REGISTRATION # AR0016490 CONSULTANT: L 1— I_ CD T 0 0 0 co r U 4 � _C C'') Z --I 00 C 00 U-j > j Q L o 0 O 0 v o � � z '� 0 Q Li W w W Z O W co Q CV N -2 .> U�@)Co z- O - N Z Ch o -czQ Co H C) U U~ Q Q M c � r (n � M J W Q a p pp 06 W LJ.. � U) / 0 W J U p LL LL Z � c W Q 0 J z U p U) W p Lo p o WO �p0 n 2 LL LO VJ VJ ISSUE DATE PERMIT SET 9 -27 -13 PROJECT NO. 2013- 5975 -01 DATE: 9 -27 -13 CADD FILE: DRAWN: S.0 CHECKED: P V SEAL: • E ( N 'y • t � a /, PABLO J. VITERI PE# 59535 SHEET TITLE: Mechanical Plan SHEET- M -1 OF SHEETS 1