13-1079-007FIRE PROTECTION LEGEND SYMBOL DESCRIPTION OR ea - CONTROL VALVE W /TAMPER SWITCH N - CHECK VALVE o-O - FLOW SWITCH 'Sl FDC - FIRE DEPARTMENT CONNECTION ea PIV - POST INDICATOR VALVE W /TAMPER SWITCH =FVC - FIRE VALVE CABINET Od FDV - STANDPIPE WITH FIRE DEPARTMENT VALVE � - SPRINKLER AND DRAIN RISER -Cj-- - BACKFLOW PREVENTOR W /TAMPER SWITCHES Ln - ROOF MANIFOLD 0 - HYDRAULIC REFERENCE NODE N - NEW SPRINKLER PIPING F.C. - FLUSHING CONNECTION O - EXISTING 3/4" UPRIGHT SPRINKLER • - EXISTING 1/2" RECESSED SPRINKLER 00 - EXISTING 1/2" CONCEALED SPRINKLER - EXISTING CONTROL VALVE W /TAMPER SWITCH O - EXISTING CHECK VALVE o-O - EXISTING FLOW SWITCH %e FDC - EXISTING FIRE DEPARTMENT CONNECTION - - - - EXISTING SPRINKLER PIPING x-*x-X-X-*c - EXISTING SPRINKLER PIPING TO BE REMOVED e- - CONNECT TO EXISTING �- - DEMOLISH TO POINT INDICATED Q1 - REVISION REFERENCE 0 - DETAIL REFERENCE: TOP- DETAIL #, C) Ld BOTTOM- DRAWING# SHOWN ON NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT DESIGN CRITERIA RETAIL STORE: OCCUPANCY CLASSIFICATION: SYSTEM TYPE: DESIGN DENSITY: HYDRAULIC REMOTE AREA: SPRINKLER ORIFICE SIZE: DURATION OF SUPPLY: MAXIMUM COVERAGE /SPRINKLER HEAD: HOSE STREAM ALLOWANCE: EXISTING STANDPIPE SYSTEM: SYSTEM DESCRIPTION: HYDRAULIC DESIGN CRITERIA: DESIGN CRITERIA: ORDINARY HAZARD GROUP 2 WET PIPE 0.1 GPM / SQ. FT. 1500 SQ. FT. 1/2" 30 - 60 MIN. 225 SQ. FT. 100 GPM EXISTING AUTOMATIC WET (CLASS 1) HYDRAULIC CALCULATIONS AND PIPE SIZES FOR EACH STANDPIPE SHALL BE BASED ON PROVIDING 250 GPM AT THE HYDRAULICALY MOST REMOTE TWO HOSE CONNECTIONS ON THE MOST REMOTE STANDPIPE AND 250 GPM FROM THE MOST REMOTE HOSE CONNECTION ON EACH ADDITIONAL STANDPIPE AT A MINIMUM RESIDUAL PRESSURE OF 100 PSI AT THE HOSE VALVE OUTLET. ASSUME A FIXED PRESSURE LOSS OF 10 PSI ACROSS THE HOSE VALVE, WHICH EQUATES TO AN INLET RESIDUAL PRESSURE TO THE HOSE VALVE OF 110 PSI. THE FOLLOWING PUBLICATIONS SHALL BE USED AS A REFERENCE FOR DESIGN OF THE FIRE SUPPRESSION SYSTEM ON THIS PROJECT. 1. NFPA 13, INSTALLATION OF SPRINKLER SYSTEMS 2. NFPA 13R, INSTALLATION OF SPRINKLER SYSTEMS IN RESIDENTIAL OCCUPANCIES 3. NFPA 14, INSTALLATION OF STANDPIPES AND HOSE SYSTEMS FIRE SPRINKLER LEGEND SYMBOL I ORF TEMP RESPONSE K -FAC FINISH MODEL /SIN STYLE PLATE MFG. • 11 /2" 155' QUICK 5.6 CHROME TY -FRB / TY3231 RECESSED CHROME TYCO GENERAL NOTES 1. FIRE PROTECTION SYSTEM TO COMPLY WITH THE LATEST EDITIONS NFPA 13, 14, 20, 24 AND ALL APPLICABLE STATE CODES. 2. FINAL INSPECTION AND APPROVAL BY LOCAL FIRE MARSHAL AND ARCHITECT /ENGINEER. 3. SPRINKLER SHOP DRAWINGS AND MATERIAL SUBMITTALS SHALL BE SUBMITTED TO THE ARCHITECT /ENGINEER AND STATE FIRE MARSHAL AND SHALL BE APPROVED PRIOR TO ANY INSTALLATION. 4. PIPE ROUTING SHOWN IS SCHEMATIC ONLY. IT IS THE RESPONSIBILITY OF THIS CONTRACTOR TO PROVIDE ANY ADDITIONAL OFFSETS REQUIRED FOR PROPER INSTALLATION AND COORDINATION WITH OTHER TRADES. 5. PIPING IN AREAS WITH EXPOSED STRUCTURE SHALL BE INSTALLED AS HIGH AS POSSIBLE TO ALLOW THE OWNER MAXIMUM USE OF THE SPACE. ' 6. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR CEILING DESCRIPTIONS AND HEIGHTS. 7. SPRINKLERS ARE TO BE COORDINATED WITH ALL DIFFUSERS, SPEAKERS, LIGHTING FIXTURES AND CEILING SYSTEMS. SPACING OF SPRINKLERS SHALL BE IN ACCORDANCE WITH NFPA 13 AND THE LISTING OF THE SPRINKLER. 8. SPRINKLER LOCATIONS SHALL BE CENTERED IN THE TILE. PROVIDE ARMOVER OR SWING JOINT AS REQUIRED. 9. SPRINKLERS IN AREAS WITH EXPOSED STRUCTURE (OBSTRUCTED CONSTRUCTION) SHALL BE INSTALLED WITH DEFLECTOR 1" BELOW THE BOTTOM OF THE BEAM (MAXIMUM 22" BELOW ROOF DECK). EXPOSED BAR JOISTS THAT HAVE SPRAY -ON FIRE PROOFING THAT MAKES THE JOIST SOLID SHALL BE TREATED LIKE A BEAM WITH THE SPRINKLERS 1" BELOW THE BOTTOM OF THE FIRE PROOFING. 10. SLEEVE AND /OR FIRESTOP ALL PENETRATIONS THROUGH RATED WALLS, CEILINGS, AND FLOORS WITH U/L LISTED ASSEMBLIES. FIRESTOP ASSEMBLIES SHALL BE EQUAL OR EXCEED THE RATING OF THE WALL, CEILING OR FLOOR. SEE ARCHITECTURAL DRAWINGS FOR FINAL FINISHES. 11. PROVIDE ACCESS PANELS TO ALL VALVES ABOVE NON- ACCESSIBLE CEILINGS AND CHASES. 12. PROVIDE A PERMANENTLY ATTACHED NAME TAG TO THE RISER STATING THE REQUIRED DESIGN CRITERIA FOR EACH HYDRAULICALLY- DESIGNED SYSTEM. 13. PROVIDE SPRINKLERS UNDERNEATH ALL EXPOSED DUCTWORK WHICH IS OVER 48" WIDE AND SPACE HEADS AROUND ALL OBSTRUCTIONS IN ACCORDANCE WITH NFPA 13. HEADS UNDER DUCTS ARE NOT INDICATED ON THE DRAWINGS BUT ARE REQUIRED AND SHALL BE PROVIDED IN ACCORDANCE WITH NFPA 13. SPRINKLER LOCATIONS UNDER DUCTWORK AND AROUND OBSTRUCTIONS SHALL BE GOVERNED BY FINAL INSTALLED LOCATIONS. 14. PROVIDE SPRINKLERS AT THE TOP AND BOTTOM OF ALL STAIRWELLS AND AT THE LANDING OF EACH FLOOR THAT OPENS INTO MORE THAN ONE FIRE ZONE. 15. PROVIDE SPRINKLER GUARDS ON ALL HEADS IN ELECTRIC ROOMS, TELEPHONE ROOMS, ELEVATOR ROOMS, ELEVATOR SHAFTS AND ON ANY HEADS LESS THAN 7' -0" ABOVE THE FLOOR. 16. IF SYSTEM PRESSURE EXCEEDS 100 PSI, ALL HANGERS ON END HEADS IN PENDANT POSITION SHALL BE WITHIN 12" OF END OF LINE IN ACCORDANCE WITH NFPA 13. 17. COORDINATE PIPING WITH ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMERS, ETC.) PRIOR TO ANY INSTALLATION. DO NOT ROUTE ANY PIPING OVER ANY ELECTRICAL PANELS UNDER ANY CIRCUMSTANCES. ANY PIPING RUN OVER ELECTRICAL SHALL BE REROUTED AT NO ADDITIONAL COST. 18. PROVIDE 20 -GAUD STEEL SPRINKLER CANOPY SHIELD AT SPRINKLERS IN TRASH CHUTE PER NFPA #13. 19. SPRINKLERS IN ELEVATOR SHAFTS AND EQUIPMENT ROOMS ARE TO BE INTERMEDIATE TEMPERATURE 2007 SPRINKLERS PER NFPA 13. 20. WET BULK SUPPLY MAINS AND HOSE SUPPLY MAINS EXPOSED TO THE WEATHER SHALL BE INSULATED AND PROVIDED WITH AN ALUMINUM JACKET. FIRE PROTECTION DRAWING INDEX SHEET I DESCRIPTION I ISSUED F -0.0 I FIRE PROTECTION LEGEND I YES F -1.0 FIRE PROTECTION FLOOR PLAN YES Y.EVISIONS JOB No. 55 -2013 DRAWN BY: A.A. SEPTEMBER 17 2013 F -0.0 401111;4111j 0t 2 / N N N b • 07 07 W O' N LO : cn I I � 7 W /� lio 1�Dd1♦i?uez,P. Ln Lo 12 N N � 0 O In Ln O O u) z Q X .O � :3 00 C) Ld J m zQ :E W J cn z � Q C� = U° `u � � 0 a_ Ln cn Z0 _O Q W � z 0 ry U o O U = N ono z Q p N W � Ll U z In cf) V) r- NOo° N J I N 0_ JOB No. 55 -2013 DRAWN BY: A.A. SEPTEMBER 17 2013 F -0.0 401111;4111j 0t 2 / N z b • O W O' N LO : cn O 410 7 W /� lio 1�Dd1♦i?uez,P. W 111111 %% 1 7 NOT VALID FOR CONSTRUCTION UNLESS SIGNED IN THIS BLOCK 0 D U) Ld z Q z FUW C) Ld J m zQ :E V) J cn � J = 0 W � Eh-'2�0 a_ Ln cn JOB No. 55 -2013 DRAWN BY: A.A. SEPTEMBER 17 2013 F -0.0 401111;4111j 0t 2 / b • e O' N _ = : Uj • : cn O 410 7 'i ..'f f /� lio 1�Dd1♦i?uez,P. 111111 %% 1 7 NOT VALID FOR CONSTRUCTION UNLESS SIGNED IN THIS BLOCK