13-1079-0042 Y" SQUARE WAS[ 12" MAX O.C. MIN. SIDE 10 "X1Y, METAL SCI FIBROUS GLASS DUCT METAL 1'X3" rvr RIYCT OR SPOT WELD TO EQUIPMENT FLANGE SHEET METAL & EQUIPMENT CONNECTION DETAIL No Scale PLAN MARK SERVING AHU -1 OFFICES NOTES: 2 3 METAL ROUND FITTING QUADRANT OPERATOR TO BE OUTSIDE INSULATION PROVIDE INSULATION GUARD WHERE NECESSARY PROVIDE FIBERGLASS INSULATION SEAL TO NECK & PERIMETER OF DIFFUSER DIFFUSER OR REGISTER (RESIDENTIAL GRADE) SEAL JOINT WITH DUCT SEALER AND TAPE — R -6 MIN. INSULATION R -6 MIN. INSULATION 0i_ \ INSULATED FLEX. DUCT R -6 MIN. INSULATION SEAL JOINT WITH DUCT SEALER AND TAPE FLEXIBLE DUCT CONNECTION DETAIL No Scale SELECTION BASED ON MANUFACTURER MODEL WEIGHT CARRIER 40YR30 130 Ibs 1 -1/2 "X22 GAUGE METAL STRAP ANCHORD TO PLYWOOD W /SPANSION ANCH. ® 6FT. MAX. MAX 5 FT. SPACING BETW. SUPPORT GAL. METAL STRAP SUPPORT W /METAL SCREW LOW VELOCITY FLEXIBLE DUCT FLEXIBLE DUCT SUPPORT DETAIL No Scale TENT MANNER WITH ALL EDGES NEATLY COVERED WITH AN APPROVED METALLIC DUCT TAPE TO VAPOR —PROOF THE ENTIRE DUCT. LAPS AND JOINTS SHALL BE SECURED WITH LAPS AND JOINTS SHALL BE SECURED WITH APPROVED TAPE NOTE 1 —DUCT INSULATION SHALL HAVE A FLAME SPREAD RATING NOT GREATER THAN 25 AND A SMOKE DEVELOPED RATING OF NOT GREATER THAN 50. 2— FLEXIBLE DUCT AND CONNECTORS SHALL BE UL 181 LISTED FLEXIBLE DUCT, 1 "X22" GAUGE SEE PLANS FOR BAND SIZE (5' MAX) MINIMUM RADIUS EQUAL TO ONE DUCT DIAMETER FLEXIBLE DUCT CONNECTION DETAIL No Scale POWER ENTF OPTIONS A COIL UNITS 0 SC°fOMY ptAN UPFLOW /DOWNFLOI SECONDARY DRAIN UPFLOW /DOWNFL01 PRIMARY DRAIN #12 WIRE CEILING DIFFUSER SEE PLANS AND SCHEDULE TYP. A.C. STAND TYP. AHU DETAIL No Scale CONNECT FLEXIBLE DUCT TO COLLAR WITH 22 GAUGE CLAMP AND FOUR SHEET METAL SCREWS AND SEAL WITH DUCT TAPE CEILING FIELD SUPPLIED SUPPLY DUCT BOARD MIN. CLEARANCE OF 4" IS REQ. BETWEEN UNIT AND WALL. WITH A TOTAL WIDTH OF CLOSET 12" WIDER THAN THE AHU'S WIDTH. AHU SHALL HAVE A CONDENSATE FLOAT SWITCH THAT WILL SHUT DOWN THE AHU IN CASE OF CONDESATE DRAINAGE STOPPAGE. ,O CLEANOUT WITH REMOVABLE SCREW CAP 20 EXTEND 3/4" CONDENSATE LINE FROM TRAP TO LOCATION INDICATED ON DRAWINGS. 3Q AT LEAST 1" GREATER THAN THE NEGATIVE PRESSURE OR MINIMUM 1 1/2 ". ® EQUAL TO 1 1/2 TIMES THE NEGATIVE STATIC PRESSURE OR MINIMUM 2 1/2 '. 05 HVAC UNIT CONDENSATE DRAIN LINE EXISTING SPLIT SYSTEM AIR HANDLING UNIT SCHEDULE FAN DATA COOLING COIL DATA ELECTRIC HEAT DATA REFRIGERANT EXT. STATIC MOTOR DATA L SENSIBLE EAT F° MINIMUM EFFICIENCY EAT F° LAT F° TYPE CFM (IN H20) HP VOLT PHASE BTUH BTUH pg Wg (SEER) DB DB STEPS VOLT PHASE R -410A 750 0.5 1� 240 1 29.200 21.500 80.0 67.0 13 70 — 7.2 1 240 1 SINGLE POINT CONNECTION YES PLAN MARK SERVING AHU -2 OFFICES NOTES: 2 3 SELECTION BASED ON MANUFACTURER MODEL WEIGHT CARRIER 40YRO36 1701bs EXISTING SPLIT SYSTEM AIR HANDLING UNIT SCHEDULE REFRIGERANT FAN DATA COOLING COIL DATA ELECTRIC HEAT DATA TYPE CFM Ems• STATIC MOTOR DATA TOTAL SENSIBLE EAT F° MINIMUM EFFICIENCY EAT F° LAT F° STEPS VOLT PHASE KW (IN H20) HP VOLT PHASE BTUH BTUH pg Wg (SEER) pg DB R -410A 1300 0.5 240 1 37.600 27.250 80.0 67.0 13 70 9.6 1 240 1 SINGLE POINT CONNECTION YES 1 UNIT ELECTRIC DATA VOLT PHASE MCA MOCP 240 1 41 45 UNIT ELECTRIC DATA VOLT PHASE MCA MOCP 240 1 55 60 Fc,EVISIONS JOB No. 55 -2013 DRAWN BY: A.A. SEPTEMBER 17 2013 M -0.0 OF 1 r� d- Z N N N� W rn rn S �W• � Q� ?�i� • �i � Qom, W i I � UNLESS SIGNED IN THIS BLOCK O In Lo a Q� N N :3 W O �—. L Z Q Q LL_ Z wUW� 00 � o J ►� -, W ^ D::E Cn x .2 a- J = O U) F� Co 0-)O LO (n W Z Q 0 U°Li � W O z LL „ O Q W [-- :2 z � U LLJ O O U =N 0 z Q 0 N W I 0 � U Z `- � LO N 0 0 N = I N r— —� < Q JOB No. 55 -2013 DRAWN BY: A.A. SEPTEMBER 17 2013 M -0.0 OF 1 N Z O N� W Ln S �W• � Q� ?�i� • �i � Qom, W LiJ UNLESS SIGNED IN THIS BLOCK O Q� C/-) W Z Q Q LL_ Z wUW� � o J zQ W ^ D::E Cn J a- J = O U) F� n- 0-)O LO (n JOB No. 55 -2013 DRAWN BY: A.A. SEPTEMBER 17 2013 M -0.0 OF 1 N� ' N ; S �W• � Q� ?�i� • �i � Qom, rt7 dri t�Z�P. NOT VA�D FOR CONSTRUCTION UNLESS SIGNED IN THIS BLOCK