Loading...
13-1079-0021 ELECTRICAL LEGEND WALL MOUNT LIGHT BRACKET 120 V. DUPLEX OUTLET GF� 120 V. G.F.I. DUPLEX OUTLET 120 V. QUADRUPLEX OUTLET 49- SWITCH � THREE WAY SWITCH E EXISTING R RELOCATED N NEW D DIMMER SWITCH W/P WATER PROOF V/P VAPOR PROOF O RECESSED DOWN LITE 120 V. SPECIAL PURPOSE OUTLET ® 240 V. SPECIAL PURPOSE OUTLET .,O JUNCTION BOX SURFACE MOUNTED FIXTURE SURFACE MOUNTED ENCLOSED FIXTURE g ELECTRICAL METER CAN ® MAIN CIRCUIT BREAKER PANEL � COMBO EXIT LIGHT SIGN AND SELF CONTAINED EMERGENCY LIGHTING UNIT. SELF - CONTAINED EMERGENCY LIGHTING UNIT, WALL. p� FIRE ALARM SPEAKER STROBE. Q. SPRINKLER } EXHAUST FAN _>CCTV CLOSED CIRCUIT TV THERMOSTAT -© CABLE TV EXTERIOR FLOOD LIGHTS © SMOKE DETECTOR �p DISCONNECT SWITCH P COMBINATION TELEPHONE /COMP. DATA OUTLET. INSTALLI8" AFF UNLESS OTHERWISE INDICATED. COMPUTER DATA OUTLET. INSTALL 18" A.F.F. UNLESS OTHERWISE INDICATED T.V. ANTENNA OUTLET. INSTALL AT SAME HEIGHT AS T.V. COORDINATE IN THE FIELD. NOTE: ALL LIGHTS TO BE CONNECTED TO DIMMER SWITCHES BUILDING SHALL COMPLY WITH FBC 2010, TABLE 803.9 INTERIOR WALLS AND CEILING FINISH REQUIREMENTS: 1- CLASS "B" FOR VERTICAL EXITS AND EXIT PASSAGEWAYS 2- CLASS "C" FOR EXIT ACCESS CORRIDORS AND OTHER EXITWAYS, ROOMS AND ENCLOSED SPACES. SCOPE OF WORK PROVIDE TENANT INTERIOR IMPROVEMENT RENOVATION PROVIDE RECEPTION, ADMINISTRATION, CONFERENCE ROOM, OFFICES, FILE ROOM AND BREAK ROOM. FLAME SPREAD BUILDING SHALL COMPLY WITH FBC 2010, TABLE 803.9 INTERIOR WALLS AND CEILING FINISH REQUIREMENTS: 1- CLASS "B" FOR VERTICAL EXITS AND EXIT PASSAGEWAYS 2- CLASS "C" FOR EXIT ACCESS CORRIDORS AND OTHER EXITWAYS, ROOMS AND ENCLOSED SPACES. OCCUPANCY LOAD CALCULATION CLASSIFICATION AS PER CHAPTER 3 OF F.B.0 2010 B - BUSINESS GROUP AS PER TABLE 1004.1.1, BUSINESS AREAS, & NFPA 2010 TABLE 7.3.1.2 100 SQ -FT GROSS/ OCCUPANT 1,653.6 SQ -FT/ 100 =16 PERSONS CONSTRUCTION TYPE ALTERATION LEVEL TYPE III B TYPE 3 AS PER F.B.C. 2010, AS PER F.B.C. 2010, EXISTING BUILDING, SECTION 602.3 BUILDING, SECTION 302 TABLE 601 FLOOR AREA CALCULATION FLOOR AREA 1,630 SQ -FT TOTAL FLOOR AREA 1,630 SQ -FT NOTE: AS PER FBC 2010, CHAPTER 3 BUILDING SECTION 304, OCCUPANCY GROUP CLASSIFICATION BUSINESS GROUP B OFFICE WALL LEGEND EX5ITNIG 8-" CONCRETE BLOCK WALL EXSITNIG COLUMN NEW 3 -5/8" METAL STUDS ® 16" O.C. GWB ON BOTH SIDES EXISTING PARTITION FIRE EXTINGUISHERS SCHEDULE MARK DESCRIPTION LOCATION COMMENTS Ld "POTTER ROEMER" OR APPROVED EQUAL RESTROOMS, OFFICES I F.E.1 TYPE: ABC TYPE- "2A -10 B, C" RATED CABINET ENCLOSED. MULTIPURPOSE ROOM I 0 "ALTA' SERIES, MODEL # 7012 -F -HB, SEMI RECESSED LOBBY/ ENTRY O 0 MOUNTING HIGHT. 60" ADOVE FINISHED FLOOR. Ln CONFERIENCE - INDEX OF DRAWINGS ARCHITECTURAL A -1 FLOOR PLAN, REFLECTED CEILING PLAN AND GENERAL NOTES A -2 TYPICAL WALL SECTION, NOTES, DOOR AND FINISH SCHEDULE MECHANICAL MO.0 HVAC FLOOR PLAN M1.0 HVAC SCHEDULE AND DETAILS F0.0 FIRE SPRINKLER LEGEND F1.0 FIRE PROTECTION FLOOR PLAN ELECTRICAL E -1 ELECTRICAL NOTES, LRGRND, PANEL SCHEDULES AND RISER DIAGRAM E -2 ELECTRICAL - POWER AND LIGHTING PLAN FA -1 FIRE ALARM NOTES, LEGEND & FIRE ALRM PLAN NOTE: EXISTING PUBLIC RESTROOMS (MENS AND WOMENS) LOCATED AT PUBLIC CORRIDORS. ' -0" ;CLG HEIGHT 8' -O" CLG HEIGHT °O RECEPTION �" GWB CEILING PTD O O � 8' -6" CLG HEIGHT O GWB CEILING PTD ' ACO ST. (TY ICAL) I 8'- D CLG HEIGHT OFFICE NO. 1 700 00 to 8' -0" CLG HEIGHT 0 3' -5" 3' -9" 8' -'6" CLNG HE GHT O GWB CEILING PTD O O O O CLOSE �FF EXISTING OPENING MATCH EXISTING CORRIDOR FINISHES GLASS DOOR E.P. U 0 N 2' -4" O 8' -O" CLG HEIGH 0 ERENCE O 2' -4" O C NF O N Ld 20 2 -8 rn I I 0 7 I 0 I 8'L6" I 1 O 0 CIIG HEIGHT Ln CONFERIENCE - N SLIDING FROSTED GLASS\ PASS THRU WINDOW 1/4"', AD INIS RA ION TEMPERED GLASS 0 3' -5" 3' -9" 8' -'6" CLNG HE GHT O GWB CEILING PTD O O O O CLOSE �FF EXISTING OPENING MATCH EXISTING CORRIDOR FINISHES GLASS DOOR E.P. U 0 N 2' -4" O 8' -O" CLG HEIGH 0 ERENCE O 2' -4" O C NF N N Ld GWB CEILING PTD rn I I - 7 I 0 I 8'L6" I 1 > 0 CIIG HEIGHT Ln CONFERIENCE - N 0 N 0 GWB CEILING PTD 0 HALL 8' -0" CLG HEIGHT O O O O O O 0 GWB CEILING PTD OFFICE NO.12 OF ICE NO. 3 8' O" C G HEIGHT 8' -O" I CLG HEIGHTI -0" CLG HEIGHT _ I FIL OFFICE NO. 4 � � I 8' -b" CLG HEIGHT NOTE: PROVIDE 1/2" METAL STUDS 22 GA. AT 16" O.C. W/ 1/2" GWB PAINTED 2'x2' ACOUSTICAL CEILING TILE (TEGULAR SHAPE BY "ARMSTRONG ") REFLECTI=D CEILING PLAN EXISTING 1 HOUR FIRE RATED DEMISING WALL 0o ADMINISTRATION o HALL 17 -8' 17 -0 4- 1 1 , " PROVIDE 4" CLEARANCE O1 p AROUND A.H.U. 4 16' -5" 2 -5 9' -0" A.H.U. O 5 F-- -- -- - - - - i OFFICE NO. 2 I I ° I I I OFFICE NO. 1 I I I I I I I I i L-- -- - - - -- COPY MACHINE- 41% ' 12' -7" iD 1 FILES /COPY °' Co - - -- _ - --_ - ?REVISIONS BREAK RO O 1 18' -0 "1 CLG HEIGHT1 I S ONLY nybR MODtF cC �' M� pputat (l�py 6%Td A �bA" pytMkel SCALE: 1/4"=l'-O'; NORTH 9 LED O > 2' -2" 11' -0" BREAK ROOM O 't_ 4' -5" 4--b 12' -4" O 4' -5" 12' -4" PROVIDE 4" CLEARANCE 0 ell AROUND A.H.0 12' -4" A.H.U. 00 /A 11 1 N O N N Ld rn rn I I - 7 I 13' -4" I 4" 4' -0" 16' -10" I 1 > RECEPTION 3 I Ln Ln CONFERIENCE - N SLIDING FROSTED GLASS\ PASS THRU WINDOW 1/4"', .-.. TEMPERED GLASS 's� GLASS DOOR L - - -- -1 LO Q' O GLASS PARTITION - L- 0 t'C TYP. REFER TO DETAIL - - - - 17' -8" PAGE A -2 17' -0" 0o ADMINISTRATION o HALL 17 -8' 17 -0 4- 1 1 , " PROVIDE 4" CLEARANCE O1 p AROUND A.H.U. 4 16' -5" 2 -5 9' -0" A.H.U. O 5 F-- -- -- - - - - i OFFICE NO. 2 I I ° I I I OFFICE NO. 1 I I I I I I I I i L-- -- - - - -- COPY MACHINE- 41% ' 12' -7" iD 1 FILES /COPY °' Co - - -- _ - --_ - ?REVISIONS BREAK RO O 1 18' -0 "1 CLG HEIGHT1 I S ONLY nybR MODtF cC �' M� pputat (l�py 6%Td A �bA" pytMkel SCALE: 1/4"=l'-O'; NORTH 9 LED O > 2' -2" 11' -0" BREAK ROOM O 't_ 4' -5" 4--b 12' -4" O 4' -5" 12' -4" PROVIDE 4" CLEARANCE 0 ell AROUND A.H.0 12' -4" A.H.U. 00 /A 11 1 I:_ N O N N Ld rn rn > �- I I � Li > Ln Ln o- N N o .-.. -� L_ U-) LO Q' O O 0 t'C t'O X O � � 00 r- Ld Z Q 0 O Z LL- „ O LJ CL:Sc � Z 0 � U LLJ .- O U O = N °0 L.I� z<0 N `_LN° I � U � .z c LO O 0 N J I N _D 0_ ��Q I:_ N O Ld Ln Ld Ld LL_I > �- 0 c W � 1 Li > U) O'- t 3(J y -� Q LL vi Ld LLJ Q Li J U) J L.� ) o OFFICE NO. 3 OFFICE NO. 4 C /i1`:tie� a V�;u lei SP Fl/ FLOOR P LAN 1PITF! Tei ,•'1 4 = ►�C3if: S SHALL 0 AG, SET F.." AIM 7Nr� 'S OF E%ISTING OCCUP ''7 rLrJRIDA FIRE PRNTIOM S, AA 4I)DRTH 0— ` L` / 00 JOB No. 13 -120 DRAWN BY: MM SEPTEMBER 2013 A -1 Y, r. x ", \ �•�' .� �'�V` y��. -11 `fit `,tea s '3 •` *- . %IANC ' 5 k` NOT VAUI3 , OR' UNLESS S16N2p91N ?HIS BLOCK