02-114-071ELECTRICAL SYMBOL LEGEND
TYPE
SYMBOL
DESCRIPTION
VOLTAGE
BASIC MATERIALS
S
LIGHT SWITCH
SN
NEW LIGHT SWITCH
So
DIMMER SWITCH
S3
3—WAY SWITCH
SSL
SAFE LIGHT/IN—USE INDICATOR
DUPLEX RECEPTACLE
DUPLEX RECEPTACLE
2' X 4' PARABOLIC, 3-LAMP, 18 CELL
RECESSED, SEMI-SPECULAR LOUVER.
MOUNTED ABOVE COUNTER
120
120
SIMPLEX RECEPTACLE
FUSED.
GFI RECEPTACLE MOUNTED ABOVE COUNTER
00=
GFI RECEPTACLE. WP DENOTES WEATHERPROOF COVER.
SPECIAL PURPOSE RECEPTACLE, RATING AS NOTED
JUNCTION BOX
20 1 1R
FUSED DISCONNECT SWITCH, SIZE AS NOTED
20
B
SWITCH RATINGZ# OF POLESZENCLOSURE NEMA RATING
FE
FUSE SIZE
SERVICE AND DISTRIBUTION
FUSED.
BRANCH CIRCUIT PANELBOARD,
SEALED NICKEL CADMIUM BATTERY
FLUSH MOUNTED
EXHAUST FAN
WITH BATTERY PACK.
LIGHTING
FLUORESCENT FIXTURE
FLUORESCENT FIXTURE
TELEPHONE /COMPUTER RACEWAY STYSTEM
1-1
<� COMBINATION DATA & COMPUTER OUTLET-4" X 4" X 2 1/4" BOX
FLECTRICAL SHEET INDEX
LIGHTING FIXTURE SCHEDULE
TYPE
DESCRIPTION
MANUFACTURER AND CATALOG NUMBER
VOLTAGE
LAMPS
REMARKS
STATIC
2' X 4, 3-LAMP, RECESSED, LENSED
METALUX
120
(3) F32T8
FUSED.
A
TROFFER,
2GR8-332A-120V-EB81-GL
Al
2' X 4' PARABOLIC, 3-LAMP, 18 CELL
RECESSED, SEMI-SPECULAR LOUVER.
METALUX
2EP3GX-332S36I-1 20V-EB81 -GL
120
120
F32T8
FUSED.
--------- -
2' X 2, 2 U-LAMP, RECESSED,
METALUX
B
STATIC TROFFER.
2GR8-2U6T8A-120V-EB81-GL
120
(2) U6T8
FUSED.
G
SEALED NICKEL CADMIUM BATTERY
SURE-LITES
(2) INCANDESCENT
WITH BATTERY PACK.
WALL-MOUNTED EMERGENCY LIGHTING.
CU-2-NC
120
5.4W PAR
L
FLUOR. UNDERCABINET
ALKCO HP-113
120
1/T5 13W
FIXTURE.
x
ARCHITECTURAL EDGE-LIT EXIT SIGN.1
SURE-LITES
ELX-7-X-70-X-R-XX-X
120
NICKEL CADMIUM BATTERY PACK.
FINISH SHALL BE SELECTED BY ARCHITECT.
3/4" CONCEALED CONDUIT
WHERE APPLICABLE
TELEPHONE/DATA OUTLET.
PROVIDE RJ45 WALL JACKS BY G.C.
TELEZDATA RECESSED OUTLET DETAIL
SCALE: NO SCALE
FLOOR
HORIZONTAL MOUNTING
IN THE BOTTOM •
CABINET TOE SPACE.
Im
-UTILITIES CABINET MOUNTING DETAI
SCALE: NO SCALE
FOR ADDITIONAL INFORMATION ABOUT SPECS, SCHEDULES, OR DETAIL
FOR ALL DENTAL EQUIPMENT, REFER TO BENCO DENTAL SHOP DRAWINGS.
CONCRETE ANCHOR
TREATMENT AREAS
LC LIGHT CEILING, UNIVERSAL
SUPPLY AND INSTALL A 1-1/2" THICK SUB PALLET, 24" X 24SECURED
TO STRUCTURAL DECK ABOVE FINISH CEILING. INSTALL SUB PALLET
DIRECTLY AGAINST TOP OF FINISH CEILING MATERIAL. SUB PALLET
TO BE LEVEL IN ALL DIRECTIONS AND CAPABLE OF SUPPORTING 300LBS.
PULL IN ALL DIRECTIONS. SEE DETAIL BELOW.
2"x4" SUPPORTS SECURED TO
STRUCTURAL DECK ABOVE PALLET.
2•x4" DIAGONAL BRACING
211x4" BLOCKING
FIN. CEILING
ELEVATION
2*-0"
O"
J__
PLAN VIEW
LIGHT CEILING DETAIL iTYPICAL�.
SCALE: NO SCALE
CABLES SHALL BE SECURELY FASTENED IN AN APPROVED MANNER AT
INTERVALS OF NOT MORE THAN 60 INCHES.
CABLE
HANGER
DETAIL
SCALE: NO SCALE
TtETilden Lobnitz Cooper
1%#ixteriny for Irchitecture
2600 DmWUm Road, Suite 200
Coral Gabtesy FL 33134 (305)774-f977
Far: (305)774-6295
Fvnn ►btee".C-71.
1dtp.-//unmv.t1*-eng(r&eemvom
LICENSE NO: 000015 71C NO: 60515
444 Brickell Avenue
Suite 900
Miami, F1
Interior Renovations for
Suite 502
at
Sunset Station
5975 Sunset Drive
South Miami, F1
Tenant
Dr. Faine, DDS
Project No.
01-414
Gonzalez-Abreu
Alas, Inc.
Architecture
7600 Red Road
Suite 203
South Miami, IFI. 33143
305 ) 740-7334
Lic: AA0002495
1 80 Dili &*i to)
0
In"I