15-342-001I 1 -4' -8" I- 31 - IIt,_Y_ 11'- F I
ADJACENT
UNIT UNIT 5973
UNIT 5-gi3 2r&, FL00R �'L,4N
SCALE: 1/4
BU ILD INC~; LEGFND
EXISTING 8" EXTEF'.IOR CONCRETE
BLOCi< WALL,
EXISTING 4" INTER,lOR FART IT ION WALL
D '
D.I
CV
N
D
D.I ;
m
v
IMIFORTANT NOTE TO C ENERAL_ C0NTR ,4CT0R:
TEMFORAR�r "Vf5" METAL F4NEL5 ACRE INSTALLED IN THIS
UNIT TO FFOTECT IT AGA IN&I' VANDAL ISM, THEREFORE THE
GENERAL CONTRACTOR &PAL.L VERIF T' 744" Of=ENING
MA50NR%' D IMEN5ION FROM OUTSIDE OF BUILDING
WITHOUT THESE FANEL5 BEFCFE FFOCEEDED IJITH THE
JOB,
SCOPE OF LUORK
THIS IS AN EXISTING TWO STORY RE51DENTIAL UNIT
TO BE:
1. REPLACED ALL WINDOWS, PROVIDING IMPACT
RESISTANT AT SECOND FLOOR
2. REPLACE EXTERIOR DOORS TO HURRICANE RESISTANT.
3. PROVIDE HURRICANE PROTECTION DEVICES
INHERE REOUIRED BY APPLICABLE CODES,
THE EXISTING BUILDING TO BE REMAIN UNDISTURBED,
A FL IC ,4BLE CODES
FBG -2010 EXISTING BUILDING
F5CR -2010,
LATEST EDITION OF NFPA
ASCE I
,4DJACENT
UN IT
UNIT 5 I5 F I�ST FLOOR f'L AN
5C,4LE: 1/4
C�ENr=R ,4L. NOTE5,
I . PRIOR TO START OF CONSTRUCTION THE CONTRACTOR OR
RESPONSIBLE FOR THE WORK, AND ALL THE SUBCONTRACTORS
SHALL VERIFY ALL DIMENSIONS IMPLIED IN THIS JOB
AND COORDINATE EXISTING CONDITIONS AT THE JOB SITE WITH
THIS PLANS AND SPECIFICATIONS. THEY SHALL REPORT
ANY INCONSISTENCIES OR ERRORS TO THE ARCHITECT/ ENGINEER
BEFORE COMMENCING WORK.
2, CONTRACTOR AND SUBCONTRACTOR SHALL COMPLETELY
FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AT
THE TIME OF BIDDING.
3, THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
PROVIDING ALL LABOR, EQUIPMENT AND SERVICES TO
PROPERLY EXECUTE THE JOB INDICATED ON THIS PLANS
5. WHERE DEMOLITION AND CUTTING WORK HAS OCURRED OR WHERE
EXISTING SURFACES, MATERIALS OR OTHERS ITEMS HAVE BEEN
DAMAGE OR DISTURBED 45A RESULTS OF THIS CONTRACT THE SAID
SURFACES AND AREAS SHALL BE CAREFULLY CLOSED Ufiz', PATCHED
AND F=INISHED AND OR RESTORED AS REQUIRED TO BE CONTIGUOUS
1 "0 EXISTING SURROUNDINn SURFACES.
9. PROVISIONS SHALL BE MADE TO ALLEVIATE THE SPREAD OF DEBRIS,
DIRT AND DUST TO ADJACENT PROPERTY OWNERS. THE PROPERTY
SHALL BE KEPT CLEAN AS POSSIBLE AT ALL TA=E TIMES.
1"(�._ERGENC't' E5CAF'E A,\lD RESCUE QFENINGS 1 =8C R 310:
W
ot
EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE
AND RESCUE OPENING. PROVIDED OPENINGS SHALL HAVE A SILL HIGHT OF NOT MORE
THAN 44 INCHES ABOVE THE FINISHED FLOOR, THE NET CLEAR OPENING DIMENSIONS
REQUIRED, SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE.
AND RESCUE OPENING FROM THE INSIDE.
MINIMUM OPENING AREA:
ALL Et- IERCIENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLAR OPENING
OF 5.1 SF
EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 SF,
MINIMUM OPENING HEIGHT.
THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24 INCHES.
MINIMUM OPENING WIDTH:
THE MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 INCHES.
EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE OF
THE ROOM WITHOUT THE USE OF KEYS OR TOOLS.
GLASS IN GUARD i�AI,�, ^ING - -:
SECT. 2401 F5C -2010
FULLY TEMPERED GLASS OR LAMINATED GLASS SHALL COMPLY WITH CATEGORY II
CPSC iro CFR 1201 OR CLASS A OF ANSI Z9l.1 LISTED IN CHAPTER 35.
FOR ALL GLAZING Tl"PES THE MIN, NOMINAL THICKNESS SHALL BE 1/4 INCH,
CLAUDIO A. JOFRE
P.E. # 28531
8421 SW 102 Ct.
MIAMI, FL 33173
PH: (786) 218 9580
PROPOSED FOR:
WINDOWS AND
EXTERIOR
DOORS
REPLACEMENT
AND SHUTTER
INSTALLATION
PROPERTY ADRE:SS:
5973 SW 61 CT
MIAMI, FL
OWNER: MIAMI -DADE COUNTY
HOUSING AGENCY
701 NW 1ST. CT 16th FLOOR
MIAMI, FL. 33136
PROJECT No.
REVISIONS
FLOOR PLAN
AND NOTES
SCALE: AS SHOWN
DRAWING: M TARIN
DATE: 03-18-2015
A -1
SHEET: 1/2
c,