Loading...
15-342-001I 1 -4' -8" I- 31 - IIt,_Y_ 11'- F I ADJACENT UNIT UNIT 5973 UNIT 5-gi3 2r&, FL00R �'L,4N SCALE: 1/4 BU ILD INC~; LEGFND EXISTING 8" EXTEF'.IOR CONCRETE BLOCi< WALL, EXISTING 4" INTER,lOR FART IT ION WALL D ' D.I CV N D D.I ; m v IMIFORTANT NOTE TO C ENERAL_ C0NTR ,4CT0R: TEMFORAR�r "Vf5" METAL F4NEL5 ACRE INSTALLED IN THIS UNIT TO FFOTECT IT AGA IN&I' VANDAL ISM, THEREFORE THE GENERAL CONTRACTOR &PAL.L VERIF T' 744" Of=ENING MA50NR%' D IMEN5ION FROM OUTSIDE OF BUILDING WITHOUT THESE FANEL5 BEFCFE FFOCEEDED IJITH THE JOB, SCOPE OF LUORK THIS IS AN EXISTING TWO STORY RE51DENTIAL UNIT TO BE: 1. REPLACED ALL WINDOWS, PROVIDING IMPACT RESISTANT AT SECOND FLOOR 2. REPLACE EXTERIOR DOORS TO HURRICANE RESISTANT. 3. PROVIDE HURRICANE PROTECTION DEVICES INHERE REOUIRED BY APPLICABLE CODES, THE EXISTING BUILDING TO BE REMAIN UNDISTURBED, A FL IC ,4BLE CODES FBG -2010 EXISTING BUILDING F5CR -2010, LATEST EDITION OF NFPA ASCE I ,4DJACENT UN IT UNIT 5 I5 F I�ST FLOOR f'L AN 5C,4LE: 1/4 C�ENr=R ,4L. NOTE5, I . PRIOR TO START OF CONSTRUCTION THE CONTRACTOR OR RESPONSIBLE FOR THE WORK, AND ALL THE SUBCONTRACTORS SHALL VERIFY ALL DIMENSIONS IMPLIED IN THIS JOB AND COORDINATE EXISTING CONDITIONS AT THE JOB SITE WITH THIS PLANS AND SPECIFICATIONS. THEY SHALL REPORT ANY INCONSISTENCIES OR ERRORS TO THE ARCHITECT/ ENGINEER BEFORE COMMENCING WORK. 2, CONTRACTOR AND SUBCONTRACTOR SHALL COMPLETELY FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AT THE TIME OF BIDDING. 3, THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL LABOR, EQUIPMENT AND SERVICES TO PROPERLY EXECUTE THE JOB INDICATED ON THIS PLANS 5. WHERE DEMOLITION AND CUTTING WORK HAS OCURRED OR WHERE EXISTING SURFACES, MATERIALS OR OTHERS ITEMS HAVE BEEN DAMAGE OR DISTURBED 45A RESULTS OF THIS CONTRACT THE SAID SURFACES AND AREAS SHALL BE CAREFULLY CLOSED Ufiz', PATCHED AND F=INISHED AND OR RESTORED AS REQUIRED TO BE CONTIGUOUS 1 "0 EXISTING SURROUNDINn SURFACES. 9. PROVISIONS SHALL BE MADE TO ALLEVIATE THE SPREAD OF DEBRIS, DIRT AND DUST TO ADJACENT PROPERTY OWNERS. THE PROPERTY SHALL BE KEPT CLEAN AS POSSIBLE AT ALL TA=E TIMES. 1"(�._ERGENC't' E5CAF'E A,\lD RESCUE QFENINGS 1 =8C R 310: W ot EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING. PROVIDED OPENINGS SHALL HAVE A SILL HIGHT OF NOT MORE THAN 44 INCHES ABOVE THE FINISHED FLOOR, THE NET CLEAR OPENING DIMENSIONS REQUIRED, SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE. AND RESCUE OPENING FROM THE INSIDE. MINIMUM OPENING AREA: ALL Et- IERCIENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLAR OPENING OF 5.1 SF EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 SF, MINIMUM OPENING HEIGHT. THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24 INCHES. MINIMUM OPENING WIDTH: THE MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 INCHES. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE OF KEYS OR TOOLS. GLASS IN GUARD i�AI,�, ^ING - -: SECT. 2401 F5C -2010 FULLY TEMPERED GLASS OR LAMINATED GLASS SHALL COMPLY WITH CATEGORY II CPSC iro CFR 1201 OR CLASS A OF ANSI Z9l.1 LISTED IN CHAPTER 35. FOR ALL GLAZING Tl"PES THE MIN, NOMINAL THICKNESS SHALL BE 1/4 INCH, CLAUDIO A. JOFRE P.E. # 28531 8421 SW 102 Ct. MIAMI, FL 33173 PH: (786) 218 9580 PROPOSED FOR: WINDOWS AND EXTERIOR DOORS REPLACEMENT AND SHUTTER INSTALLATION PROPERTY ADRE:SS: 5973 SW 61 CT MIAMI, FL OWNER: MIAMI -DADE COUNTY HOUSING AGENCY 701 NW 1ST. CT 16th FLOOR MIAMI, FL. 33136 PROJECT No. REVISIONS FLOOR PLAN AND NOTES SCALE: AS SHOWN DRAWING: M TARIN DATE: 03-18-2015 A -1 SHEET: 1/2 c,