11-956R-001B A A ELECTRICAL LEGEND: $ SWITCH p p ? - SQUARE FEET OF CONDITION SPACE 1,695 GENERAL LIGHTING AT 3 WATT SQ.FT. PUSH — BUTTON SMALL APPIANCES CIRCUITS 2 PB 31000 $3 THREE —WAY SWITCH DOUBLE OVEN 0 CLOTHES DRYER 5 000 q TELEVISION ANTENNA BATH DUPLEX RECEPTACLE POOL EQUIPMENT 0 S.P.A. EQUIPMENT 0 MICROWAVE AND HOOD TELEPHONE JACK CLOTHES WASHER POLED DUPLEX RECEPTACLE REFIGERATOR 850 DISWASHER 1 200 0 SMOKE DETECTOR W/ {� SINGLE RECEPTACLE SD BATTERY BACKUP Q SPECIAL RECEPTACLE ❑J DISCONNECT SWITCH Q CEILING MOUNTED FIXTURE SM-07-1 ELECTRIC PANEL �- WALL MOUNTED FIXTURE R3 ELECTRIC METER TOTAL 26611 AT 240 VOLTS 111 NEUTRAL LOAD CALCULATION (VA RECESSED CEILING FIXTURE WP WEATHER PROOF GENERAL LIGHTING, WASHER& SMALL APP. EXHAUST FAN GFI GROUND FAULTED ,Z, 8000 RANGE AT 70% INTERRUPTER IJ DOORBELL CLOTHES DRYER AT 70% 3 500 DB 2000 -I-B -- HOSE BIB 2" RGC TO POWER COMP 41 3 # 2 -0 THW CU. MITER /MAIN - -- COMBINATION W/ 200 ANIP. O,C.P, ELECTRICAL NOTES 1- ALL WORK SHALL BE PERFORMED TO MEET THE REQUIREMENTS OF THE GOVERNING EDITION OF THE NATIONAL ELECTRICAL CODE (N.E.C), LOCAL AND STATE CODES AND ANY OTHER APPLICABLE CODES AND STANDARS. 2- ALL WIRING SHALL BE COPPER (CU) THWN INSULATION. IF ALUMINUM WIRES ARE USED: A) TO PREVENT OVERHEATING AT CONNECTION POINTS USE OXIDE INHIBITING COMPOUND FOR STRIPPED PORTION OF CONDUCTORS INSIDE CONNECTORS, B) A PREVENTIVE MAINTENANCE PLAN IS NECESSARY TO ENSURE A RELIABLE SERVICE INCLUDING VISUAL INSPECTIONS AND TESTS FOR SPLICES AND CONNECTION POINTS (CORROSION AND TIGHTNESS PRINCIPALLY). INSPECTION INTERVALS OF 2 YEARS MAXIMUM ARE STRONGLY RECOMMENDED, 3- ALL CIRCUIT BREAKERS SHALL BE RATED AT MINIMUM OF 10,000 AIC. 4- PRIOR TO INSTALLATION OF ROUGH ELECTRICAL WIRING, CHECK NAMEPLATE DATA OF ALL EQUIPMENT FOR REQUIRED VOLTAGES, MINIMUM CIRCUIT AMPACITY, AND OVERCURRENT PROTECTION. 5- ELECTRICAL CALCULATIONS WERE BASED ON INFORMATION PROVIDED BY ELECTRICAL CONTRACTOR AND OWNER AGENT. ELECTRICAL CONTRACTOR TO VERIFY LOAD FOR EACH CIRCUIT AND ADJUST ACCORDINGLY, CHANGES TO BE REFLECTED IN THE DRAWINGS. 6- ALL BRANCH CIRCUITS SHALL BE PROPERLY PHASE BALANCED. 7- ALL NEW CONDUCTORS SHALL BE RUN IN CONDUIT (METALLIC TYPE) UNLESS THAT NONMETALLIC SHEATHED CABLE CAN BE USED IN DRY LOCATIONS AS PER NEC 336-6. 8- IF PVC CONDUITS ARE USED FOR UNDERGROUND FEEDERS, A GROUNDING CONDUCTOR SIZED IN ACCORDANCE WITH N.E.C. 250 -172 MUST BE INSTALLED AND CONDUIT SIZE INCREASED AS REQUIRED. 9- TYPEWRITTEN PANEL TALLY SHALL BE FURNISHED AFTER JOB IS COMPLETED REFLECTING ALL CHANGES AND ADDITIONS FOR NEW PANELS. 10- THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL CONTRACTOR FOR INSTALLATION OF MACHANICAL EQUIPMENT. 11- RISERS ARE DIAGRAMMATIC ONLY. THEY DO NOT SHOW EVERY BEND REQUIRED FOR THE INSTALLATION, ELECTRICAL CONTRACTOR TO FIND NEW CONDENSER 1SER UNI jr2 BEST POSSIBLE ROUTE FOR ALL CIRCUITS. 12- THIS DRAWING IS A GUIDE FOR THE INSTALLATION OF ELECTRICAL 6 SERVICE. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE A FUNCTIONING SYSTEM. 13- ALL OUTLETS IN NEW CONSTRUCTION TO BE PROTECTED BY AFCI BREAKERS. 14- OUTLETS IN FIRE RATED WALLS SHALL BE SEPARATED 24" HORIZONTALLY (MIN). 15- ALL SMOKE DETECTORS TO BE LOCATED V APART MIN, FROM A/C OUTLETS. AND INTERCONNECTED FOR SIGNALING PURPOSE. 16- ELECTRICAL CONTRACTOR TO VERIFY ILUMINATION LEVELS AT INTERIOR STAIRS (1 FOOTCANDLE MINIMUM ON TREADS AND LANDINGS) ACCORDING TO THE FLORIDA BUILDING CODE R303,6. 17- ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ARCHITEC /OWNER TO FIELD VERIVY INSTALLATION FOR OUTLETS, LIGHTING FIXTURES AND ELECTRICAL EQUIPMENT. -- 150 AMP MAIN SWITCH DISC. 150/150 3 # 1 THW CU. IN 1 -1/2" COND. 150IMP, ELI PANEL LO S.N. PROVIDE A 3/4" EMPTY CONDUCT TO A (2) GANG J BOX W/ COVER PLATE IN GARAGE AREA 10,000 A/Cj L_ 1 #6 TWCUIN COND. TO CWP. ROD 2 - 5/8 DIAMETER _._� ` water pipe 8' -0" DEEP GROUNDING EXISTING ELECTRICAL RISER N.T.S. LOAD CALCULATION (VA) PANEL 11,411 p p ? - SQUARE FEET OF CONDITION SPACE 1,695 GENERAL LIGHTING AT 3 WATT SQ.FT. 51085 SMALL APPIANCES CIRCUITS 2 SMALL APPLIANCES LOAD 31000 RANGE OVEN OR COOKTOP 12 000 DOUBLE OVEN 0 CLOTHES DRYER 5 000 HOT WATER HEATER 4 500 BATH 650 POOL EQUIPMENT 0 S.P.A. EQUIPMENT 0 MICROWAVE AND HOOD 1 000 CLOTHES WASHER 1 500 REFIGERATOR 850 DISWASHER 1 200 DISPOSAL 0 WHIRPOOL 0 1- GARAGE DOOR OPENER GATE & MOTOR 1200 2- GARAGE DOOR OPENER GATE & MOTOR 0 CONNECTED LOAD WITHOUT A/C LOAD 30792 FIRST 10 000 AT 100% 10000 REST AT 40% 8316 A/C LOAD AT 100% 8,295 20 1 1 TOTAL 26611 AT 240 VOLTS 111 NEUTRAL LOAD CALCULATION (VA fDANEL "All XIST. S APPLIANCE 12 GENERAL LIGHTING, WASHER& SMALL APP. 2000 FIRST 3000 AT 100% 600 REST AT 357o 8000 RANGE AT 70% 5 600 DOUBLE OVEN AT 70% 0 CLOTHES DRYER AT 70% 3 500 OTHER LOAD 2000 TOTAL NEUTRO LOAD 16200 AT 240 VOLTS 67.5 15 SERVICE SHALL BE PROTECTED AT 200 Amp TYPE: LOADCENTER EXISTING MAIN BUS: 150 A SERVICE: PANEL "All NEUTRAL: 1'30 A VOLTAGE: 12.0/240V !PH, :3W LUGS MOUNTING: FLUSH AIC: 22,000 p p ? - u REMARKS REMARKS p } �- n° {L 50 2 8000 R 6 EXIST. COOKTOP 1 2 WATER HEATER 10 R 4500 2 25 3 4 20 1 850 R 12 EXIST. REFIGERATOR 5 6 BATH GFI 12 R 600 1 20 20 1 1 1500 R 12 EXIST,SMALL APPLIANCE 7 8 XIST. S APPLIANCE 12 R 1500 20 15 1 * R 14 NEW. G. LIGHTING 9 10 EXIST. G. LIGHTING 14 R * 1 15 15 1 * R 14 EXIST. G. LIGHTING 11 12 NEW G. LIGHTING 14 R * 1 15 15 1 * R 14 EXIST, G. LIGHTING 13 14 EXIST. G. LIGHTING 14 R * 1 15 15 1 * R 14 EXIST, BEDROOM 1 15 16 EXIST. BEDROOM 2 14 R * 1 15 20 1 * R 12 EXIST. BEDROOM 1 17 18 EXIST. BEDROOM 2 12 R * 1 20 60 2 10000 THWN 6 EXIST. A.H.U. No 1 19 20 C.U. No 1 (NOT CURRENT 8 R 5500 2 30 21 22 30 2 5,000 R 10 EXIST. CLOTHES DRYER 23 24 MINI SPLIT #1 2 1 750 2 20 25 26 COND.MINI SPLIT #1 2 1 750 2 20 15 1 * R 14 GENERAL LIGHTING 27 28 NEW GENERAL LIGHTING 12 R * 1 20 20 1 1,500 R 12 EXIST, CLOTHES WASHER 29 30 MINI SPLIT #2 2 1 750 2 20 20 1,500 R 12 EXIST. 31 32 SPACE - - - - - 20 1,500 R 12 EXIST. MICROWAVE 33 34 SPACE - - - - - - - - - - SPACE 35 36 SPACE - - - - - - - - - - SPACE 37 38 SPACE - - - - - - - - - - SPACE 39 40 SPACE - - - - - - - - - - SPACE 41 42 SPACE - - - - - CONNECTED LOAD: SEE RISER AND LOAD CALCULATION FEEDER: SEE RISER FED FROM: SEE RISER L DENOTED ARC FAULT. INT. CIR. BREAKER ARC FAULT INT. CIRC. NOTE. ALL BRANCH CIR. 120/15 -20 A THAT SUPPLY RECEPTACLES IN BEDROOMS SHALL BE PROTECTED BY ARC. FAULT, CIR. BREAKER. AS PER NEC 210 -12 -b 8 . I E-'+ E- l cc` rV c:6 U_` ^ c !(J t� Al U E -1 �f1.ie,t.•::a fk- LLT,_ w •