11-956R-001B A A
ELECTRICAL LEGEND:
$
SWITCH
p
p ?
-
SQUARE FEET OF CONDITION SPACE
1,695
GENERAL LIGHTING AT 3 WATT SQ.FT.
PUSH — BUTTON
SMALL APPIANCES CIRCUITS
2
PB
31000
$3
THREE —WAY SWITCH
DOUBLE OVEN
0
CLOTHES DRYER
5 000
q
TELEVISION ANTENNA
BATH
DUPLEX RECEPTACLE
POOL EQUIPMENT
0
S.P.A. EQUIPMENT
0
MICROWAVE AND HOOD
TELEPHONE JACK
CLOTHES WASHER
POLED DUPLEX RECEPTACLE
REFIGERATOR
850
DISWASHER
1 200
0
SMOKE DETECTOR W/
{�
SINGLE RECEPTACLE
SD
BATTERY BACKUP
Q
SPECIAL RECEPTACLE
❑J
DISCONNECT SWITCH
Q
CEILING MOUNTED FIXTURE
SM-07-1
ELECTRIC PANEL
�-
WALL MOUNTED FIXTURE
R3
ELECTRIC METER
TOTAL
26611
AT 240 VOLTS
111
NEUTRAL LOAD CALCULATION (VA
RECESSED CEILING FIXTURE
WP
WEATHER PROOF
GENERAL LIGHTING, WASHER& SMALL APP.
EXHAUST FAN
GFI
GROUND FAULTED
,Z,
8000
RANGE AT 70%
INTERRUPTER
IJ
DOORBELL
CLOTHES DRYER AT 70%
3 500
DB
2000
-I-B --
HOSE BIB
2" RGC TO
POWER COMP 41
3 # 2 -0 THW CU.
MITER /MAIN - --
COMBINATION
W/ 200 ANIP. O,C.P,
ELECTRICAL NOTES
1- ALL WORK SHALL BE PERFORMED TO MEET THE REQUIREMENTS OF THE GOVERNING
EDITION OF THE NATIONAL ELECTRICAL CODE (N.E.C), LOCAL AND STATE CODES
AND ANY OTHER APPLICABLE CODES AND STANDARS.
2- ALL WIRING SHALL BE COPPER (CU) THWN INSULATION.
IF ALUMINUM WIRES ARE USED:
A) TO PREVENT OVERHEATING AT CONNECTION POINTS USE OXIDE INHIBITING COMPOUND
FOR STRIPPED PORTION OF CONDUCTORS INSIDE CONNECTORS,
B) A PREVENTIVE MAINTENANCE PLAN IS NECESSARY TO ENSURE A RELIABLE SERVICE
INCLUDING VISUAL INSPECTIONS AND TESTS FOR SPLICES AND CONNECTION POINTS
(CORROSION AND TIGHTNESS PRINCIPALLY).
INSPECTION INTERVALS OF 2 YEARS MAXIMUM ARE STRONGLY RECOMMENDED,
3- ALL CIRCUIT BREAKERS SHALL BE RATED AT MINIMUM OF 10,000 AIC.
4- PRIOR TO INSTALLATION OF ROUGH ELECTRICAL WIRING, CHECK NAMEPLATE
DATA OF ALL EQUIPMENT FOR REQUIRED VOLTAGES, MINIMUM CIRCUIT AMPACITY,
AND OVERCURRENT PROTECTION.
5- ELECTRICAL CALCULATIONS WERE BASED ON INFORMATION PROVIDED BY
ELECTRICAL CONTRACTOR AND OWNER AGENT. ELECTRICAL CONTRACTOR
TO VERIFY LOAD FOR EACH CIRCUIT AND ADJUST ACCORDINGLY, CHANGES
TO BE REFLECTED IN THE DRAWINGS.
6- ALL BRANCH CIRCUITS SHALL BE PROPERLY PHASE BALANCED.
7- ALL NEW CONDUCTORS SHALL BE RUN IN CONDUIT (METALLIC TYPE) UNLESS
THAT NONMETALLIC SHEATHED CABLE CAN BE USED IN DRY
LOCATIONS AS PER NEC 336-6.
8- IF PVC CONDUITS ARE USED FOR UNDERGROUND FEEDERS, A GROUNDING
CONDUCTOR SIZED IN ACCORDANCE WITH N.E.C. 250 -172 MUST
BE INSTALLED AND CONDUIT SIZE INCREASED AS REQUIRED.
9- TYPEWRITTEN PANEL TALLY SHALL BE FURNISHED AFTER JOB IS
COMPLETED REFLECTING ALL CHANGES AND ADDITIONS FOR NEW PANELS.
10- THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL
CONTRACTOR FOR INSTALLATION OF MACHANICAL EQUIPMENT.
11- RISERS ARE DIAGRAMMATIC ONLY. THEY DO NOT SHOW EVERY BEND
REQUIRED FOR THE INSTALLATION, ELECTRICAL CONTRACTOR TO FIND
NEW CONDENSER 1SER UNI jr2 BEST POSSIBLE ROUTE FOR ALL CIRCUITS.
12- THIS DRAWING IS A GUIDE FOR THE INSTALLATION OF ELECTRICAL
6 SERVICE. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE A
FUNCTIONING SYSTEM.
13- ALL OUTLETS IN NEW CONSTRUCTION TO BE PROTECTED BY AFCI BREAKERS.
14- OUTLETS IN FIRE RATED WALLS SHALL BE SEPARATED 24" HORIZONTALLY (MIN).
15- ALL SMOKE DETECTORS TO BE LOCATED V APART MIN, FROM A/C OUTLETS.
AND INTERCONNECTED FOR SIGNALING PURPOSE.
16- ELECTRICAL CONTRACTOR TO VERIFY ILUMINATION LEVELS AT INTERIOR STAIRS
(1 FOOTCANDLE MINIMUM ON TREADS AND LANDINGS)
ACCORDING TO THE FLORIDA BUILDING CODE R303,6.
17- ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ARCHITEC /OWNER
TO FIELD VERIVY INSTALLATION FOR OUTLETS, LIGHTING FIXTURES
AND ELECTRICAL EQUIPMENT.
-- 150 AMP MAIN SWITCH DISC.
150/150
3 # 1 THW CU.
IN 1 -1/2" COND.
150IMP, ELI
PANEL LO S.N.
PROVIDE A 3/4" EMPTY
CONDUCT TO A (2) GANG
J BOX W/ COVER PLATE
IN GARAGE AREA
10,000 A/Cj
L_ 1 #6 TWCUIN
COND. TO CWP.
ROD 2 - 5/8 DIAMETER _._� ` water pipe
8' -0" DEEP GROUNDING
EXISTING ELECTRICAL RISER N.T.S.
LOAD CALCULATION (VA)
PANEL 11,411
p
p ?
-
SQUARE FEET OF CONDITION SPACE
1,695
GENERAL LIGHTING AT 3 WATT SQ.FT.
51085
SMALL APPIANCES CIRCUITS
2
SMALL APPLIANCES LOAD
31000
RANGE OVEN OR COOKTOP
12 000
DOUBLE OVEN
0
CLOTHES DRYER
5 000
HOT WATER HEATER
4 500
BATH
650
POOL EQUIPMENT
0
S.P.A. EQUIPMENT
0
MICROWAVE AND HOOD
1 000
CLOTHES WASHER
1 500
REFIGERATOR
850
DISWASHER
1 200
DISPOSAL
0
WHIRPOOL
0
1- GARAGE DOOR OPENER GATE & MOTOR
1200
2- GARAGE DOOR OPENER GATE & MOTOR
0
CONNECTED LOAD WITHOUT A/C LOAD
30792
FIRST 10 000 AT 100%
10000
REST AT 40%
8316
A/C LOAD AT 100%
8,295
20
1 1
TOTAL
26611
AT 240 VOLTS
111
NEUTRAL LOAD CALCULATION (VA
fDANEL "All
XIST. S APPLIANCE
12
GENERAL LIGHTING, WASHER& SMALL APP.
2000
FIRST 3000 AT 100%
600
REST AT 357o
8000
RANGE AT 70%
5 600
DOUBLE OVEN AT 70%
0
CLOTHES DRYER AT 70%
3 500
OTHER LOAD
2000
TOTAL NEUTRO LOAD
16200
AT 240 VOLTS
67.5
15
SERVICE SHALL BE PROTECTED AT
200 Amp
TYPE: LOADCENTER EXISTING MAIN BUS: 150 A
SERVICE: PANEL "All NEUTRAL: 1'30 A
VOLTAGE: 12.0/240V !PH, :3W LUGS
MOUNTING: FLUSH AIC: 22,000
p
p ?
-
u
REMARKS
REMARKS
p }
�-
n°
{L
50
2
8000
R
6
EXIST. COOKTOP
1
2
WATER HEATER
10
R
4500
2
25
3
4
20
1
850
R
12
EXIST. REFIGERATOR
5
6
BATH GFI
12
R
600
1
20
20
1 1
1500
R
12
EXIST,SMALL APPLIANCE
7
8
XIST. S APPLIANCE
12
R
1500
20
15
1
*
R
14
NEW. G. LIGHTING
9
10
EXIST. G. LIGHTING
14
R
*
1
15
15
1
*
R
14
EXIST. G. LIGHTING
11
12
NEW G. LIGHTING
14
R
*
1
15
15
1
*
R
14
EXIST, G. LIGHTING
13
14
EXIST. G. LIGHTING
14
R
*
1
15
15
1
*
R
14
EXIST, BEDROOM 1
15
16
EXIST. BEDROOM 2
14
R
*
1
15
20
1
*
R
12
EXIST. BEDROOM 1
17
18
EXIST. BEDROOM 2
12
R
*
1
20
60
2
10000
THWN
6
EXIST. A.H.U. No 1
19
20
C.U. No 1 (NOT CURRENT
8
R
5500
2
30
21
22
30
2
5,000
R
10
EXIST.
CLOTHES DRYER
23
24
MINI SPLIT #1
2
1
750
2
20
25
26
COND.MINI SPLIT #1
2
1
750
2
20
15
1
*
R
14
GENERAL LIGHTING
27
28
NEW GENERAL LIGHTING
12
R
*
1
20
20
1
1,500
R
12
EXIST, CLOTHES WASHER
29
30
MINI SPLIT #2
2
1
750
2
20
20
1,500
R
12
EXIST.
31
32
SPACE
-
-
-
-
-
20
1,500
R
12
EXIST. MICROWAVE
33
34
SPACE
-
-
-
-
-
-
-
-
-
-
SPACE
35
36
SPACE
-
-
-
-
-
-
-
-
-
-
SPACE
37
38
SPACE
-
-
-
-
-
-
-
-
-
-
SPACE
39
40
SPACE
-
-
-
-
-
-
-
-
-
-
SPACE
41
42
SPACE
-
-
-
-
-
CONNECTED LOAD: SEE RISER AND LOAD CALCULATION FEEDER: SEE RISER
FED FROM: SEE RISER
L DENOTED ARC FAULT. INT. CIR. BREAKER
ARC FAULT INT. CIRC. NOTE.
ALL BRANCH CIR. 120/15 -20 A THAT SUPPLY RECEPTACLES IN BEDROOMS
SHALL BE PROTECTED BY ARC. FAULT, CIR. BREAKER.
AS PER NEC 210 -12 -b
8
.
I
E-'+
E- l
cc`
rV
c:6 U_`
^
c !(J
t�
Al
U
E -1
�f1.ie,t.•::a
fk- LLT,_ w
•