Loading...
08-834-020PROVIDE 2 —#5 VERT. BAR UNDER GIRDER TRUSS #5 VERT. BAR INTO EXISTING WALL; SEE DETAIL 4/S -3 s 6 1 Ica _ #5 VERT. BAR O 7- —_ 48" MAX(TYP.) T m r-, u PROVIDE a- r-DaR TRUSS I lu I I Ila I I FOUNDATION PLAN I F -1 F -1 F-1 -� WF -16 r- - - —r WF -16- f- I F- F SOIL STATEMENT SUAL INSPECTION THE SOIL CONSIST OF SAND WITH ASSUMED BEARING CAPACITY OF 2000 ETTER WILL BE SUBMITTED AFTER THE GROUND BROKEN ATTESTING THAT THE SITE OBSERVED D.CONDITIONS ARE SIMILAR TO THOSE ON WHICH N IS BASED. 80 8" 2 #5 -30 "x30" CORNER BAR 0 BOTT, FOR FTGS. TYP. CORNER DET. FOR FTGS. N.T.S. 101 1614OW1r ■i,W" E r.ww 7bat IWO% 1111111 FOOTING SCHEDULE MARK SIZE REINFORCING EA. WAY TOP ELEV. F -1 3' x1 ; -o 6"X3' -6" — 2 # 5 4 #5 T 8c B —2' -0" WF -16 16 "X12" 2 # 5 -- _1 1_4" COLUMN SCHEDULE K SIZE REINF. TIES REMARKS C -1 8"X8"X1O" 2 # 5 — — C -2 5"X8"X10" 2 # 5 — C -3 I 8"X12" 4 111 5 #308" C -4 8"X 16" 4# 6 # 3 0 8" C -5 8"X27" 6 6 3 08" SC -1 8,•X12, 4 5 3 0 8" STARTER COLUMN 6 • ALL BUILDINGS SHALL HAVE PRE - CONSTRUCTION TREATMENT PROTECTION AGAINST SUB - TERRANEAN TERMITES AS PER FBC 1816.1.7. A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES ". Y or SOUTH MIAts BUILI)p4G DEPT, ma Revisions ft Date Desa'I Uw 1 8 -29 -08 BLDG.DPT. lJ m , r , 1 � 1 1 1 • i i 1 r. Ln i •• i U. i i 1 In Revisions ft Date Desa'I Uw 1 8 -29 -08 BLDG.DPT. lJ Sheet nie. FOUNDATION PLAN do DETAILS ! OF S -2 f m Sheet nie. FOUNDATION PLAN do DETAILS ! OF S -2 f