08-834-0191. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH APPLICABLE REQUERIMENTS OF THE "FLORIDA BUILDING CODE ", 2004 EDITION. 2. VERIFY ALL DIMENSIONS ON DRAWINGS AND CONDITIONS AT JOB SITE PRIOR TO COMMENCING WORK. NOTIFY ENGDINEER OR OWNER REPRESENTATIVE OF ANY DISCREPANCIES AND SECURE AN INTERPRETATION OR DECISION FROM THE ENGINEER BEFORE PROCEEDING WITH THE WORK. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. 3. OBTAIN THE LATEST SET OF DRAWINGS, INCLUDING ANY REVISIONS, BEFORE COMMENCING WORK. NO CHANGES OR SUBSTITUTIONS SHALL BE MADE WITHOUT MADE THE WRITTEN PERMISSION OF THE OWNER /ENGINEER. 4. THE ENGINEER DOES NOT ACCEPT RESPONSIBILITY FOR THE MISINTERPRETATION OF THESE PLANS BY OTHERS, THE REVIEW AND APPROVAL OF SHOPDRAWINGS BY OTHERS. 5. THE CONTRACTOR IS FULLY RESPONSIBLE FOR ANY ITEMS PURCHASED BY THE OWNER AND GIVEN TO HIM FOR INSTALLATION. 6. ENGINEER'S VISITS AT THE SITE DURING CONSTRUCTION SHALL BE SCHEDULE WITH CONTRACTOR WITHIN 24 HOURS IN ADVANCE PRIOR TO INSPECTION. 7. VERIFY DOOR AND WINDOW OPENINGS SIZE REQUIRED WITH MANUFACTURER. 8. CONTRACTOR SHALL COORDINATE AND VERIFY WITH OWNER TYPE AND KIND OF INTERIOR FINISHES DESIRED BY OWNER WHICH ARE NOT SPECIFIED IN DRAWINGS. 9. IF ANY ERRORS OR OMISSIONS APPEAR IN THE DRAWINGS, SPECIFICATIONS OR OTHER DOCUMENTS THE CONTRACTOR SHALL NOTIFY TO THE ENGINEER IN WRITING OF SUCH OMISSIONS OR ERRORS PRIOR TO PROCEEDING WITH ANY WORK WHICH APPEARS IN QUESTION. IN THE EVENT OF THE CONTRACTOR'S FAILING TO GIVE SUCH NOTICE, HE SHALL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY SUCH ERRORS OR OMISSIONS AND THE COST OF RECTIFYING 10. THE CONTRACTOR SHALL USE THESE DRAWINGS TOGETHER WITH THE MECHA- NICAL AND ELECTRICAL AND PLUMBIONG DRAWINGS TO LOCATE OUTLES, RECESSES, OPENINGS, SLEEVES, DIMENSIONS, ETC. POTENTIAL CONFLICTS SHALL BE TRANSMITTED TO THE ENGINEER BEFORE PROCEEDING WITH THE WORK 11. DO NOT OBTAIN ANY MEASUREMENT BY SCALE OR VISUAL RELATION. REPORT ANY MISSING OR CONFLICTING DIMENSION TO THE ENGINEER IMMEDIATELY UPON DISCOVERY. 12. FINISH MATERIALS, COLORS, PATTERNS AND TEXTURES WILL BE SELECTED BY THE OWNER. 13. OBTAIN CLARIFICATION AND INTERPRETATION OF DRAWINGS AND SPECIFICATIONS INCLUDING ADDITIONAL DETAIL, DIRECTLY FROM THE ENGINEER. L - 1. ALL REINFORCEMENT STEEL SHALL BE NEW BILLET STEEL CONFORMING R.C. .- 1. SHALL BE DEFORMED BARS, FREE FROM LOOSE RUST AND SCALE, AND TO ASTM A615, GRADE 60. Scale CONFORMING TO ASTM A -615, GRADE 60. COLUMN AND BEAM TIES 2. UNLESS OTHERWISE NOTED, ALL DETAILING, FABRICATION, AND PLACING M Z OF REINFORCING STEEL SHALL CONFORM TO THE MANUAL OF STANDARD EXPOSED SURFACE SHALL BE EPDXY COATED REINFORCING STEEL. PRACTICE FOR DETAILING REINFORCED CONCRETE MEMBERS. 2. ALL DETAILING AND ACCESSORIES SHALL CONFORM TO TYPICAL DETAILS 3. LAP ALL BAR SPLICES 48 BAR DIAMETERS (12" MIN.) UNLESS OTHER - M WISE NOTED. 4. ALL CONCRETE SHALL DEVELOP A MINIMUM OF 3000 PSI COMPRESSIVE AFTER FABRICATION. ACCESSORIES FOR REINFORCING SHALL BE IN STRENGTH IN 28 DAYS UNLESS OTHERWISE NOTED. ACCORDANCE WITH ACI, 2004 EDITION. 5. WIRE MESH REINFORCEMENT SHALL BE WELDED SMOOTH WIRE FABRIC c 6. WIRE MESH REINFORCEMENT SHALL LAP ONE FULL MESH +2" AND BE - 5. ALL CONTINUOUS VERTICAL OR HORIZONTAL BARS IN FOOTINGS, FOUNDATIONS, SECURELY WIRED AT EACH SIDE AND END. WALLS, SLABS AND OTHER CONCRETE SHALL BE LAP- SPLICED 48 BAR DIA 9. MINIMUM COVER FOR REINFORCING STEEL UNLESS OTHERWISE NOTED SHALL BE: ELEMENTS SHALL BE CONTINUED TO FAR SIDES OF INTERSECTING ELEMENTS. A. CONCRETE DEPOSITED AGAINST THE GROUND 3" N 4-J B. CONCRETE EXPOSED TO THE WEATHER OR IN Zi I CONTACT WITH THE GROUND 2" C. SLABS AND WALLS NOT EXPOSED TO THE WEATHER OR IN CONTACT WITH THE GROUND 3/4" = M D. BEAMS (OVER MAIN REINFORCING) 2" E. SLAB ON GRADE (NON STRUCTURAL) - CAD CENTER LINE J L F. COLUMNS (OVER MAIN REINFORCING) 2" MASONRY NOTES: 1. MATERIALS: A. ALL CONCRETE UNITS SHALL CONFORM TO ASTM C90 -85 AND ASTM C145 -85. PRISM STRENGTH fm = 1500 PSI. B. MORTAR: TYPE M. COMPLYING WITH THE REQUIREMENTS OF ASTM C270 -86. C. GROUT: SHALL BE 3/8" MAXIMUM SIZE PEAROCK CONFORMING TO ASTM C- 476 -83 WITH 28 DAYS MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI GROUT SLUMP TO BE 8 "MINIMUM,10 "MAX D. REINFORCING BARS: ASTM A615. GRADE 60. E. JOINT REINFORCEMENT: TO BE #8 LADDER -TYPE DUROWALL AT 16" O.C. 2. CONSTRUCTION: MATERIALS, METHODS OF CONSTRUCTION,INSPECTION AND TESTING SHALL BE SPECIFIED BY NCMA AND ACI. A. MORTAR BEDDING MASONRY UNITS SHALL BE LAID IN RUNNING BOND WITH FACE SHELL BEDDING EXCEPT THE FIRST COURSE OF MASONRY ON FOUNDATIONS SHALL BE LAID IN FULL BEDDING. B. LAPPING REINFORCEMENT: (APPLICABLE AT SIDE OF OPENINGS) 1. REINFORCING BARS SHALL BE LAPPED 48 BAR DIAMETERS. 2. JOINT REINFORCING SHALL BE OVERLAPPED 6" MINIMUM. C. GROUTING SHALL BE A CONTINUOUS OPERATION IN LIFTS NOT EXCEEDING 4' -0" AND A MAXIMUM POUR OF 12' -0 ". WIND PRESSURE /DESIGN CRITERIA (BASED ON A.S.C.E. 7 -02 & SECT. 1609 OF F.B.C. 2004) BASIC WIND SPEED ...................... ............................146 MPH IMPORTANCE FACTOR .................... ............................1.0 EXPOSURE CATEGORY .............. ............................... C BUILDING CLASSIFICATION ........ ............................... CATEGORY II DIRECTIONALITY FACTOR .......... ............................... kd. = 0.85 EXPOSURE FACTOR kz .......... ............................... TABLE 6.5 ANCHOR #1(SEE ANCHOR SCHEDULE) GAUGE 3'X3" METAL DRIP.ON 1X2 P.T. WOOD NAILER TO MATCH EXISTING. RAKE BEAM RB -1 (SEE BEAM SCHEDULE) 2" X 8' WOOD FASCIA PAINT FINISHED #5VERT. BAR 048-O.0 �� SMOOTH STUCCO FINISH ON SELF FURRING WIRE -LATH SOFFIT ON 34" PLYWOOD 8 GA LADDER TYPE HORIZONTAL JOINT REINF. 016 "O.C. VERT. 518" SMOOTH STUCCO FINISH ON WCMU WALL (FOR BAND AND TRIMINGS SEE ELEV.) CONC. BEAM. (FOR SIZE AND REIF. SEE STRUCT DETAIL SMOOTH STUCCO BAND (FOR SIZE AND TRIM SEE ELEV.) BEAM B -1 (SEE BEAM SCHEDULE) ALUMINUM GARAGE DOOR (FOR ZIZE AND TYPE SEE D&W SCHED.) 12 1 3 BATT. INSULATION. - 1► 1/2" GYPSUM WALLBOARD APPLIED ON 7/8 MTL HI -HATS STRIP 0 16" O.C. MAX. TYP. P.T. 1"X4" WOOD FIRE STOP 8"X12" CONC. TIE BEAM W/4 f 5'S CONT. do 2 # 5 BENT 30" EA. WAY AT CORNERS. PROVIDE 4 #3 TIES 0 12" O.C. AT CORNERS do AT 48" THEREAFTER PRESSURE TREATED WOOD FURRING STRIPS 0 16" O.C. TYP. W /R -5 INSULATION. 1/2" GYPSUM WALLBOARD OVER 1X2 FIRE STOP WOOD BASE NEOPRENE EXPANSION JOINTS 4" CONC. SLAB W /6X6- W1.4XW1.4 W.W.M. OVER COMP. FILL do 6 MILL VAPOR BARRIER FIN. FLOOR +0.00' a tl 1' -6" r 5/8" CDX EXTERIOR PLYWOOD NAILED WITH f8d NAILS SPACED 6" O.C. O EDGE 6" O.C. INTERIOR AND AT 4' AT GABLE END WITH 30 FELT PAPER 2" MIN. LAPPED, THIN -CAP 32 GA X 1 -5/8 DIAM. NAILED 0 12" O.C.TO RECEIVED CONCRETE TILE PRE - ENGINEERED ROOF TRUSSES AT 24" O.C. SEE TRUSS CONNECTOR SCHEDULE AT SHEET S -3 GALV. DRIP ON 1 "X4" PT. WD. BLOCK'G do 1 "X8" P.T. WD. FASCIA PROVIDE 4"X12" SCREENED VENT O 4' -8" PAPER BACKED METAL LATH W/ LIGHT TEXTURE STUCCO FINISH STUCCO OVER 8" CONC. BLOCK 518" CDX EXTERIOR PLYWOOD NAILED WITH #8d NAILS SPACED 6" O.C. 0 EDGE 6" O.C. INTERIOR AND AT 4" AT GABLE END WITH 30 FELT PAPER 2" MIN. LAPPED, THIN -CAP 32 GA X 1 -5/8 DIAM. NAILED O 12" O.C.TO RECEIVED SHINGLES • �_.® PREFAB WD. TRUSSES 0 24" O.C. (MANUF. TO SUBMIT SHOP DRAWINGS FOR ARCHITECT APPROVAL) I -�-- -- 1" X 3' P.T. CLG. FURR. 0 16 " O.C. \-I *X2* PT FIRE STOP 5/8" GYPSUM BOARD EL+ 8' 0" (DATUM) TOP 'OF TIE -BW 0 I Ga SOOTH FINISH CONC. SLAB (SEE STRUCT. DRAWINGS) EL9.85 N.G.V.D. - P 'OF DATUM) EL8.85 N.G.V.D. 'EC. =i = 6''(bATUT�j H.P. OF GARAGE SPRAY UNDER SLAB TERMITE TREATMENT 6 MIL VISQUEEN MOISTURE BARRIER ONC. FOOTING (FOR SIZE do REINF. SEE STRUCTURAL DET) TYPICAL WALL SECTION 2 SCALE 314" =1' -0" T.O.B. + 8'- 7112" WALL SECTION 3 SCALE 3/4" =1' -0" s -1 5/8" CDX EXTERIOR PLYWOOD NAILED WITH #8d NAILS SPACED 6" O.C. O EDGE 6" O.C. INTERIOR AND AT 4" AT GABLE END WITH 30 FELT PAPER 2" MIN. LAPPED, THIN -CAP 32 GA X 1 -5/8 DIAM. NAILED 0 12" O.C.TO RECEIVED A BUILT UP 3"X 12"WD.JOISTS016 "O.C. REINFORCING STEEL. ASPHALT FlNISH DRIVEWAY R.C. .- 1. SHALL BE DEFORMED BARS, FREE FROM LOOSE RUST AND SCALE, AND R.C. Scale CONFORMING TO ASTM A -615, GRADE 60. COLUMN AND BEAM TIES L co 0 SHALL BE OF GRADE 40. FOR SLABS, BEAMS, GRADE BEAMS, WALLS, ETC. M Z THAT ARE EXPOSED TO WEATHER, THE REINFORCING LAYER CLOSE TO THE "h LEA oti EXPOSED SURFACE SHALL BE EPDXY COATED REINFORCING STEEL. 2. ALL DETAILING AND ACCESSORIES SHALL CONFORM TO TYPICAL DETAILS ui rn SHOWN IN THE "MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED M CONC STRUCTURES ACI 315, 2004 EDITION ". 3. ALL ACCESSORIES SHALL HAVE UPTURNED LEGS AND BE PLASTIC DIPPED ui h AFTER FABRICATION. ACCESSORIES FOR REINFORCING SHALL BE IN ACCORDANCE WITH ACI, 2004 EDITION. n T 4. ALL REINFORCING STEEL SHALL BE TIED DOWN AND INDEPENDENTLY c SUPPORTED ON CHAIRS AND SUPPORT BARS. - 5. ALL CONTINUOUS VERTICAL OR HORIZONTAL BARS IN FOOTINGS, FOUNDATIONS, NOTE: BACKFlLL UNDER ALL SLAB AND WALLS, SLABS AND OTHER CONCRETE SHALL BE LAP- SPLICED 48 BAR DIA FOOTINGS (TYP.) OR 2' -0" MINIMUM WHICHEVER IS GREATER (EXCEPT AS NOTED ON DRAWINGS). LAPS FOR EPDXY COATED REINFORCING SHALL BE INCREASED BY 50 %. ELEMENTS SHALL BE CONTINUED TO FAR SIDES OF INTERSECTING ELEMENTS. 12 1 3 BATT. INSULATION. - 1► 1/2" GYPSUM WALLBOARD APPLIED ON 7/8 MTL HI -HATS STRIP 0 16" O.C. MAX. TYP. P.T. 1"X4" WOOD FIRE STOP 8"X12" CONC. TIE BEAM W/4 f 5'S CONT. do 2 # 5 BENT 30" EA. WAY AT CORNERS. PROVIDE 4 #3 TIES 0 12" O.C. AT CORNERS do AT 48" THEREAFTER PRESSURE TREATED WOOD FURRING STRIPS 0 16" O.C. TYP. W /R -5 INSULATION. 1/2" GYPSUM WALLBOARD OVER 1X2 FIRE STOP WOOD BASE NEOPRENE EXPANSION JOINTS 4" CONC. SLAB W /6X6- W1.4XW1.4 W.W.M. OVER COMP. FILL do 6 MILL VAPOR BARRIER FIN. FLOOR +0.00' a tl 1' -6" r 5/8" CDX EXTERIOR PLYWOOD NAILED WITH f8d NAILS SPACED 6" O.C. O EDGE 6" O.C. INTERIOR AND AT 4' AT GABLE END WITH 30 FELT PAPER 2" MIN. LAPPED, THIN -CAP 32 GA X 1 -5/8 DIAM. NAILED 0 12" O.C.TO RECEIVED CONCRETE TILE PRE - ENGINEERED ROOF TRUSSES AT 24" O.C. SEE TRUSS CONNECTOR SCHEDULE AT SHEET S -3 GALV. DRIP ON 1 "X4" PT. WD. BLOCK'G do 1 "X8" P.T. WD. FASCIA PROVIDE 4"X12" SCREENED VENT O 4' -8" PAPER BACKED METAL LATH W/ LIGHT TEXTURE STUCCO FINISH STUCCO OVER 8" CONC. BLOCK 518" CDX EXTERIOR PLYWOOD NAILED WITH #8d NAILS SPACED 6" O.C. 0 EDGE 6" O.C. INTERIOR AND AT 4" AT GABLE END WITH 30 FELT PAPER 2" MIN. LAPPED, THIN -CAP 32 GA X 1 -5/8 DIAM. NAILED O 12" O.C.TO RECEIVED SHINGLES • �_.® PREFAB WD. TRUSSES 0 24" O.C. (MANUF. TO SUBMIT SHOP DRAWINGS FOR ARCHITECT APPROVAL) I -�-- -- 1" X 3' P.T. CLG. FURR. 0 16 " O.C. \-I *X2* PT FIRE STOP 5/8" GYPSUM BOARD EL+ 8' 0" (DATUM) TOP 'OF TIE -BW 0 I Ga SOOTH FINISH CONC. SLAB (SEE STRUCT. DRAWINGS) EL9.85 N.G.V.D. - P 'OF DATUM) EL8.85 N.G.V.D. 'EC. =i = 6''(bATUT�j H.P. OF GARAGE SPRAY UNDER SLAB TERMITE TREATMENT 6 MIL VISQUEEN MOISTURE BARRIER ONC. FOOTING (FOR SIZE do REINF. SEE STRUCTURAL DET) TYPICAL WALL SECTION 2 SCALE 314" =1' -0" T.O.B. + 8'- 7112" WALL SECTION 3 SCALE 3/4" =1' -0" s -1 5/8" CDX EXTERIOR PLYWOOD NAILED WITH #8d NAILS SPACED 6" O.C. O EDGE 6" O.C. INTERIOR AND AT 4" AT GABLE END WITH 30 FELT PAPER 2" MIN. LAPPED, THIN -CAP 32 GA X 1 -5/8 DIAM. NAILED 0 12" O.C.TO RECEIVED A BUILT UP 3"X 12"WD.JOISTS016 "O.C. Revisions Na I Date I�Desa0tim Date 07 -17 -2008 0­4 R.C. .- Chedmd By R.C. Scale AS SHOWN L co 0 U M Z cal "h LEA oti ui rn M QIL ui h n c tin C V V N 4-J Zi cU tU .- Q O = M C J L o 0 45 O 3: u. Q m Z L Proms Mnber. SEAL: d - CHAVARftL4►•P.E.,� FL Ur- *74 DATE: 7- /r7- 8 175 FWANENLEAU BLVD. STE.2G -6A MIA41A -33172 Ph: 305-229-3874 Revisions Na I Date I�Desa0tim Date 07 -17 -2008 Drawn by R.C. .- Chedmd By R.C. Scale AS SHOWN NOTES Sheet T#Je: 1 a i S --t