08-834-018CONCRETE MARKER: 6" DiAM. x 2"
THICK OR 6" x 6" x 2" THICK
FlNISHED GRADE
CONCRETE COVER NTH HANDLE-,
24"
6"
Qa
4
�a
o °
as
3/4" WASHED ROCK
BUILDING WALL ---�_
3/4" RELIEF VENT
INSECT SCREEN
\ 6° MINIMUM
12" MINIMUM
24" DIAMETER
2" DIAM. DRAIN LINE
GROUT AT INLET
CONCRETE PIPE
0
o�
o
SATE DRYWELL DETAIL
HANGER -OD
SUPPORT HANGER ROD LOCKING NUT ALL THREAD ROD
SUPPORT
SUPPORT HEAVY DUTY CLEVIS
HEAVY DUTY /
CLEVIS
HANGER ALL THREAD • OD
HANGER
....... VAPOR BARRIER HEAVY DUTY PLAS11C
,.
.. — O _ tE'
-� , GAUGE ZINC COATED PIPE
SHEET ESADDLE
LEAST 8 LONG
HANGER
SINGLE HORIZONTAL RUNS CLEVIS HANGER PIPE HANGER DETAIL
NO VAPOR :. -- - INSULATK)N SINGLE HORrZONTAL -• • AREAS
,WrrH VAPOR BARRIER INSULATION
PIPE SUPPORT DETAIL
(FOR SANITARY + WATER PIPING)
1, 21 3 AND 4 HOUR FIRE RATED
GYPSUM WALL
WOOD OR STEEL STUD
1/4" MINIMUM DIAMETER
BEAD OF FIRE RESISTANT CAULK
METALLIC PiPE OR CONDUIT
FIRE RESISTANT CAULK
NOTES:
1. THE CAULK iS TO BE FORCED INTO THE ANNULAR SPACE TO THE MAXIMUM EXTENT
POSSIBLE FLUSH WITH THE EXTERIOR OF THE PENETRATION SURFACE.
2. FINISH CAULKING WITH A 1/4" MINIMUM BEAD OF FIRE RESISTANT CAULK APPLIED TO
THE PERIMETER OF THE CONDUIT /PIPE AT iTS EGRESS FROM THE WALL
PLUMBING NOTES:
1. A. All work shall be preformed in accordance with the Florida
Building Code 2004 Edition with suppliments.
B. Drawings: Refer to all drawings for coordination of the
plumbing work,
C. Arrange and pay for all permits, licenses, inspections
and tests. Obtain the required certificates and present
to owner.
D. Guarantee: The completed installation shall be fully
guaranteed against defective materials and /or improper
workmanship for a minimum of one year for material and
labor.
E. All horizontal sanitaru piping shall slope at 1/8 inch
per foot minimum for 3° and larger and at 1/4" slope
for 2" pipes and smaller.
2. Shop drawings: Contractor shall submit for approval all
specified items. No work shall proceed without the aproval
of these submittals.
3. Plumbing fixtures:
Fixtures shall be complete with drains, traps, supplies and any aaher
accessory required.
4. Materials`
A. Piping:
a. Soil, waste and vent: Service weight Cast Iron pipe.
Schedule 40 PVC can be used below slab on grade.
b. Domestic water and Heating Hot Water.
Copper pipe, Type L with sweat wrought
copper fittings. Type "M" in concealed spaces is
acceptable. Isolate piping from concrete with
insulating material.
c. Condensate drain: DWV PVC.
d. Domestic water supply assembly. Chrome finish tubing
with angle shut off valves.
e. Insulation: Insulate all hot water lines
r with 1" thick fiberglass
insulation, with self sealing jacket.
Insulate condensate piping with 1/2" elastomeric insulation.
5. All water heaters shall meet the
standards of the latest energy efficiency code.
6. Piping testing and cleaning:
A. Test: All sanitary and domestic water supply piping shall
be tested for leaks before piping is concealed or connected
to equipment and plumbing fixtures.
B. Disinfection: All domestic water piping shall be
disinfected by introducing a solution of calcium
hypochlon a of 50 parts per million of chloride and as
per AWWA Standards.
7. Valves: Domestic water valves shall be of bronze body,
sweat ends.
8. All exterior clean outs shall be terminated up to grade
and shall be marked.
9. Contractor shall coordinate exact location of sanitary,
ECO 3. THE MAXIMUM ANNULAR SPACE IS NOT TO EXCEED 3/16 . and domestic water piping before starting any work. Notify
STUDOR VENT Architect/Engineer of any deviations from design drawings.
SINK ri 10. Contractor shall cut and patch to match existing concrete floor
2" to match existing as required for new work.
3°
2"
2"
2* WSB
FIRE RATED
21# 3» VTR 2» PIPE PENETRATION DETAIL
SINK 30 NTS
3"
3"
SANITARY PIPING ISCJMETRIC
wilm
NO SCALE
ED-0m
WATER PIPE SIZE
NOMINAL TRAP SIZE
MAXIMUM FLOW RATES
EXISTING PIPING TO REMAIN
WATER CLOSE
1/2"
3"
128 GPF
BIDET
3/8"
1 1/2"
lA GPM
LAVATORY
1/2"
11/2"
B GPM
LAUNDRY TUB
1/2"
'211
1.0 GPM
SHOWER
1/2"
2"
IB GPM
KITCHEN S24K
1/21'
1 1/2"
lA GPM
4 ALL PLU-MING FIXTURES AND APPLIANCES SHALL COMPLY WITH THE 03 -01 -08 DADE COUNTY
WATER USE EFFICIENCY STANDARDS ORDINANCE OS -14 AND TABLE 604.4 FBC PLUMBING.
DISHWASHER -627 GALLONS PER CYCLE, WASHING MACHINE WATER FACTOR OF 8 OR LOWER
SOV (ENERGY STAR CERTIFIED)
WATER PIPING ISOMETRIC
NO SCALE
PLUMBING SYMBOL LEGEND
SYMBOL
DESCRIPTION
EXISTING PIPING TO REMAIN
SANITARY LINE
~
VENT LINE
CD
CONDENSATE LINE
COLD WATER LINE
HOT WATER LINE
FCO
FLUSH CLEAN OUT
FD
FLOOR DRAIN
CO
CLEAN OUT
0
CONNECT NEW TO EXISTING
Pmjed Number:
Lmed Fbr
~
"
0
ro
o
M
M
rn
in
J
u-
Q
o
�..
Ce
Q
•
1
C
U
U
•
U.
i
r.
Pmjed Number:
Lmed Fbr
"
ro
0
Ln
•
1
C
i
•
U.
i
CD
E
Pmjed Number:
Lmed Fbr
'' ■
MM■
`neat n� - --
PLUMBING
DETAILS
Sheet No.
P-2
"
'' ■
MM■
`neat n� - --
PLUMBING
DETAILS
Sheet No.
P-2