Loading...
08-834-018CONCRETE MARKER: 6" DiAM. x 2" THICK OR 6" x 6" x 2" THICK FlNISHED GRADE CONCRETE COVER NTH HANDLE-, 24" 6" Qa 4 �a o ° as 3/4" WASHED ROCK BUILDING WALL ---�_ 3/4" RELIEF VENT INSECT SCREEN \ 6° MINIMUM 12" MINIMUM 24" DIAMETER 2" DIAM. DRAIN LINE GROUT AT INLET CONCRETE PIPE 0 o� o SATE DRYWELL DETAIL HANGER -OD SUPPORT HANGER ROD LOCKING NUT ALL THREAD ROD SUPPORT SUPPORT HEAVY DUTY CLEVIS HEAVY DUTY / CLEVIS HANGER ALL THREAD • OD HANGER ....... VAPOR BARRIER HEAVY DUTY PLAS11C ,. .. — O _ tE' -� , GAUGE ZINC COATED PIPE SHEET ESADDLE LEAST 8 LONG HANGER SINGLE HORIZONTAL RUNS CLEVIS HANGER PIPE HANGER DETAIL NO VAPOR :. -- - INSULATK)N SINGLE HORrZONTAL -• • AREAS ,WrrH VAPOR BARRIER INSULATION PIPE SUPPORT DETAIL (FOR SANITARY + WATER PIPING) 1, 21 3 AND 4 HOUR FIRE RATED GYPSUM WALL WOOD OR STEEL STUD 1/4" MINIMUM DIAMETER BEAD OF FIRE RESISTANT CAULK METALLIC PiPE OR CONDUIT FIRE RESISTANT CAULK NOTES: 1. THE CAULK iS TO BE FORCED INTO THE ANNULAR SPACE TO THE MAXIMUM EXTENT POSSIBLE FLUSH WITH THE EXTERIOR OF THE PENETRATION SURFACE. 2. FINISH CAULKING WITH A 1/4" MINIMUM BEAD OF FIRE RESISTANT CAULK APPLIED TO THE PERIMETER OF THE CONDUIT /PIPE AT iTS EGRESS FROM THE WALL PLUMBING NOTES: 1. A. All work shall be preformed in accordance with the Florida Building Code 2004 Edition with suppliments. B. Drawings: Refer to all drawings for coordination of the plumbing work, C. Arrange and pay for all permits, licenses, inspections and tests. Obtain the required certificates and present to owner. D. Guarantee: The completed installation shall be fully guaranteed against defective materials and /or improper workmanship for a minimum of one year for material and labor. E. All horizontal sanitaru piping shall slope at 1/8 inch per foot minimum for 3° and larger and at 1/4" slope for 2" pipes and smaller. 2. Shop drawings: Contractor shall submit for approval all specified items. No work shall proceed without the aproval of these submittals. 3. Plumbing fixtures: Fixtures shall be complete with drains, traps, supplies and any aaher accessory required. 4. Materials` A. Piping: a. Soil, waste and vent: Service weight Cast Iron pipe. Schedule 40 PVC can be used below slab on grade. b. Domestic water and Heating Hot Water. Copper pipe, Type L with sweat wrought copper fittings. Type "M" in concealed spaces is acceptable. Isolate piping from concrete with insulating material. c. Condensate drain: DWV PVC. d. Domestic water supply assembly. Chrome finish tubing with angle shut off valves. e. Insulation: Insulate all hot water lines r with 1" thick fiberglass insulation, with self sealing jacket. Insulate condensate piping with 1/2" elastomeric insulation. 5. All water heaters shall meet the standards of the latest energy efficiency code. 6. Piping testing and cleaning: A. Test: All sanitary and domestic water supply piping shall be tested for leaks before piping is concealed or connected to equipment and plumbing fixtures. B. Disinfection: All domestic water piping shall be disinfected by introducing a solution of calcium hypochlon a of 50 parts per million of chloride and as per AWWA Standards. 7. Valves: Domestic water valves shall be of bronze body, sweat ends. 8. All exterior clean outs shall be terminated up to grade and shall be marked. 9. Contractor shall coordinate exact location of sanitary, ECO 3. THE MAXIMUM ANNULAR SPACE IS NOT TO EXCEED 3/16 . and domestic water piping before starting any work. Notify STUDOR VENT Architect/Engineer of any deviations from design drawings. SINK ri 10. Contractor shall cut and patch to match existing concrete floor 2" to match existing as required for new work. 3° 2" 2" 2* WSB FIRE RATED 21# 3» VTR 2» PIPE PENETRATION DETAIL SINK 30 NTS 3" 3" SANITARY PIPING ISCJMETRIC wilm NO SCALE ED-0m WATER PIPE SIZE NOMINAL TRAP SIZE MAXIMUM FLOW RATES EXISTING PIPING TO REMAIN WATER CLOSE 1/2" 3" 128 GPF BIDET 3/8" 1 1/2" lA GPM LAVATORY 1/2" 11/2" B GPM LAUNDRY TUB 1/2" '211 1.0 GPM SHOWER 1/2" 2" IB GPM KITCHEN S24K 1/21' 1 1/2" lA GPM 4 ALL PLU-MING FIXTURES AND APPLIANCES SHALL COMPLY WITH THE 03 -01 -08 DADE COUNTY WATER USE EFFICIENCY STANDARDS ORDINANCE OS -14 AND TABLE 604.4 FBC PLUMBING. DISHWASHER -627 GALLONS PER CYCLE, WASHING MACHINE WATER FACTOR OF 8 OR LOWER SOV (ENERGY STAR CERTIFIED) WATER PIPING ISOMETRIC NO SCALE PLUMBING SYMBOL LEGEND SYMBOL DESCRIPTION EXISTING PIPING TO REMAIN SANITARY LINE ~ VENT LINE CD CONDENSATE LINE COLD WATER LINE HOT WATER LINE FCO FLUSH CLEAN OUT FD FLOOR DRAIN CO CLEAN OUT 0 CONNECT NEW TO EXISTING Pmjed Number: Lmed Fbr ~ " 0 ro o M M rn in J u- Q o �.. Ce Q • 1 C U U • U. i r. Pmjed Number: Lmed Fbr " ro 0 Ln • 1 C i • U. i CD E Pmjed Number: Lmed Fbr '' ■ MM■ `neat n� - -- PLUMBING DETAILS Sheet No. P-2 " '' ■ MM■ `neat n� - -- PLUMBING DETAILS Sheet No. P-2