11-1035-009N PROPOSE MECHANICAL PLAN M 1 . Q 1 4' 8' 16° SCALE: 1/4" 1' -0" HVAC GENERAL NOTES 1. GENERAL A. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 2007, 2009 SUPPLEMENT AND WITH ALL APPLICABLE REGULATIONS. B. DRAWINGS: REFER TO ALL DRAWINGS FOR COORDINATION OF THE HVAC WORK. C. ARRANGE AND PAY FOR ALL PERMITS LICENSES, INSPECTIONS AND TESTS. OBTAIN THE REQUIRED CERTIFICATES AND PRESENT TO OWNER. D. GUARANTEE: THE COMPLETED INSTALLATION SHALL BE FULLY GUARANTEED AGAINST DEFECTIVE MATERIALS AND /OR IMPROPER WORKMANSHIP FOR A MINIMUM OF ONE YEAR FOR MATERIAL AND LABOR. COMPRESSOR SHALL BE GUARANTEED FOR 5 YEARS MINIMUM. 2. DESIGN PARAMETERS: A. INDOOR DESIGN TEMPERATURE (SUMMER): 78 °F DB B. INDOOR DESIGN TEMPERATURE (WINTER): 70 °F DB 3. EQUIPMENT SPECIFIED BY MANUFACTURER'S NUMBER SHALL INCLUDE ALL ACCESSORIES, CONTROLS, ETC., LISTED IN THE CATALOG AS STANDARD WITH THE EQUIPMENT. OPTIONAL OR ADDITIONAL ACCESSORIES SHALL BE FURNISHED AS SPECIFIED. 4. CONTROLS: AIR CONDITIONING UNIT SHALL BE STARTED AND STOPPED THRU INDIVIDUAL THERMOSTAT. INDIVIDUAL PROGRAMMABLE THERMOSTATS SHALL START /STOP SUPPLY FANS AND ACTIVATE COOLING/HEATING SYSTEMS AS SELECTED. NOTES IT IS THE INTENT OF THESE PLANS TO PROVIDE A COMPLETE OPERATING SYSTEM. A/C CONTRACTOR SHALL FURNISH AND INSTALL ALL REQUIRED EQUIP. MATERIALS, ETC, EXCEPT WHERE SPECIFICALLY NOTED AS BEEN PROVIDED BY OTHERS. SHOULD THERE BE ANY QUESTIONS CONCERNING RESPONSIBILITY, THEY SHALL BE SETTLED BEFORE BID SUBMISSION AND CONTRACT SIGNING; NO EXTRA CHARGES WILL BE ALLOWED. DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT NECESSARILY SHOWING IN DETAIL OR TO EXACT SCALE ALL MINOR ITEMS WINDOW/WALL AC UNIT SCHEDULE UNIT TAG AC-1- 4 MANUFACTURER GE DATE ® AREA SERVED NEW ADDITION Z UNIT TYPE WINDOW / WALL UNIT .m ��( W_ 4 U QUANTITY 1 W ,J EER 9.4 W REFRIGERANT TYPE R-410 Q LLJ AJEM12DCD MODEL W Q M SUPPLY AIR FLOW (CFM) 304/286 U W J TOTAL COOLING CAPACITY (BTU /H) 11,600 0 Q uJ M U ELECTRICAL HEATING (BTU /,H) 11,600/9,500 a CL as DESHUMIDIFICATION (PTS /H) 3.4 H W �o ELECTRICAL SERVICE (VOLT/PH /HZ) 230/208 -1 -60 Qw - Q Z=�U) COOLING AMPS 5.8/6.3 Wo mg C�3 o a m 1235/1215 �/ COOLING WATTS L0 V HEATING AMPS 1 6.0/14.5 W8 U HEATING WATTS 3680/3020 JMAX OVERCURRENT PROTECTION (A) 20 LIJ <� =Z i< W OPERATING WEIGHT (LBS) S0 NOTES AND ACCESSORIES: 1. UNITS RATED IN ACCORDANCE WITH ARI STANDARDS 210/240 OR 3601270. 2• PROVIDE UNIT LEVEL WITHIN PRESCRIBED TOLERANCES. 3. PROVIDE 1 YEAR MANUFACTURER WARRANTY (PARTS AND LABOR) 4. EXTENDED 5 YEARS COMPRESSOR WARRANTY PARTS ONLY. 5. PROVIDE SLOPED CONDENSATE DRAIN PAN AND INTERNAL TRAP. 6. PROVIDE MOTOR OVERLOAD AND THERMAL PROTECTION. 7. PROVIDE A REMOTE T'STAT. COORDINATE LOCATION WITH ARCHITECT. —.WSW :► i Q 0eZ►z a3 •�� ,,• yam• = o r. -- W EXTERIOR WALL '���r /p .. * PRQ� ~4" ��litllttli ��` u W APPROVE�1 SUP. AIR DISCHARGE CAULKING, W ` 08 ALL AROUND WALL �' OPENING - W o f pd PERFORAT WALL z VENT CAP 12 °1 SLEEVE- r— H MIN SLOPE 1 /8"/FT. AG .: RET. AIR INLET Q Z a] lD° UNIT W/FILTER. - I, L[i W LL In ((} t 311 ACKETSTEEL ANGLE NOTE. W W �, 1 1/4'° UNION 80T, �P BOLTED 0 REFER TO MANUFACTURERS Z Z In WALL. INSTALLATION INSTRUCTIONS. LL o ELI J 'o .. m w DQ= >W ob CONDENSATE TRAP DETAIL A/C UNIT WALL MOUNTING DETAIL [- E- N.T.S. N.T.S. DWG. TITLE MECHANICAL PLAN SCALE AS SHOWN nr2nwnt my r:ur'n DATE REVISION .m ��( W_ 4 O Q LLJ W Z M U W (y W Q uJ M CL as H �o w Qw - � Z=�U) Wo mg C�3 o a m Q �/ � L0 W8 >� <� =Z i< W W> �; U m °LL P Eo'q �.. _m Z ul �y LL i2 W� LL °F Z W U LLI E— W r cy) W �S ° NN W M W Lu g I@ 0 • �. Q a0 Y wz ulco Wp V � = Ure L .3 -3 J LL 0 �W O C] cn 0Z IL W Lo a� —.WSW :► i Q 0eZ►z a3 •�� ,,• yam• = o r. -- W EXTERIOR WALL '���r /p .. * PRQ� ~4" ��litllttli ��` u W APPROVE�1 SUP. AIR DISCHARGE CAULKING, W ` 08 ALL AROUND WALL �' OPENING - W o f pd PERFORAT WALL z VENT CAP 12 °1 SLEEVE- r— H MIN SLOPE 1 /8"/FT. AG .: RET. AIR INLET Q Z a] lD° UNIT W/FILTER. - I, L[i W LL In ((} t 311 ACKETSTEEL ANGLE NOTE. W W �, 1 1/4'° UNION 80T, �P BOLTED 0 REFER TO MANUFACTURERS Z Z In WALL. INSTALLATION INSTRUCTIONS. LL o ELI J 'o .. m w DQ= >W ob CONDENSATE TRAP DETAIL A/C UNIT WALL MOUNTING DETAIL [- E- N.T.S. N.T.S. DWG. TITLE MECHANICAL PLAN SCALE AS SHOWN nr2nwnt my r:ur'n