11-1035-001N rl_ PROPOSE FLOOR PLAN A1.0 1 4' 8' 16' SCALE: 1/4"= V -0" s 0 r Ill U Z W ❑ Q W W W Z O Z �. X W SCOPE OF WORK THE PROPOSED SCOPE OF WORK CONSIST IN OBTAINING PERMITS FOR: 1 -) ENCLOSED EXISTING TERRACE WITH NEW 8" CMU WALL. WORKS PERFORMED: a -) STRUCTURAL WORK (FOUNDATION AND WALL) b-) ELECTRICAL WORKS. c -) NO MECHANICAL WORKS. d -) NO PLUMBING WORKS. GENERAL NOTES: 1. BATHROOM FLOORS AND BASE TO BE OF IMPERVIOUS MATERIAL AS PER 1204 F.B.C. WALL 2. IN AN OUTSIDE WINDOW OR DOOR OPERABLE FROM THE INSIDE, THE MODE OF OPERATION DESCRIPTION INDICATES EXISTING RESIDENCE. w SHALL NOT REQUIRE THE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE OR EFFORT. SUCH W FINISH EACH SIDE AS PER F.B.C.2004 -FEBC, T CLEAR OPENING SHALL BE NOT LESS THAN 20" IN WIDTH, AND 24" IN HEIGHT, 5.7 SQ. FT. IN AREA THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44" ABOVE THE FINISHED EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM INDICATES EXISTING 8 "x8 "x16" MASONRY UNITS. OPNG FLOOR AND NO PART OF THE OPERATING MECHANISM SHALL BE PLACED HIGHER THAN 54" w� EXISTING STEEL COLUMNS AT COVERED PORCH. AREA ABOVE FINISHED FLOOR. EXISTING RESIDENCE: 1395.00 SQ.FT. EXISTING COVER PORCH: 238.00 SQ.FT. 3. NUMBERS OF ADDRESS SHALL BE PLACED VISIBLE AND LEGIBLE FROM THE STREET FRONTING 1633.00 SQ.FT. (CLOSETS AND BATHROOMS) NFPA 101 -1994 CHAPTER -21 (21- 2,4,3) EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM INSIDE THE CLOSET (21- 2.4.4) EVERY BATHROOM THE PROPERTY AND SHALL BE 3 INCHES MIN. IN HEIGHT. DOOR TYPE OF LOCK OR LATCH MUST COMPLY W /FBC R311.4.4. OUTSIDE IN AN EMERGENCY. EXTERIOR APPLICATIONS TYPICAL DOOR JAMB DETAIL _ 1 1/2" = 1 ° -0" _ WALL LEGEND: DESCRIPTION INDICATES EXISTING RESIDENCE. w INDICATES EXISTING PARTITION WALL WITH W FINISH EACH SIDE AS PER F.B.C.2004 -FEBC, T 1604.5. EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM INDICATES EXISTING 8 "x8 "x16" MASONRY UNITS. OPNG INDICATES EXISTING 8 "x8 "x16" MASONRY UNITS. w� EXISTING STEEL COLUMNS AT COVERED PORCH. AREA CALCULATIONS EXISTING RESIDENCE: 1395.00 SQ.FT. EXISTING COVER PORCH: 238.00 SQ.FT. TOTAL 1633.00 SQ.FT. 5. REFER TO FOUNDATION PLAN (SHEET A -1) FOR CONCRETE FILLED BLOCK CELL LOCATION, SIZE AND REINFORCING. 6. ALL GLASS USED INSIDE OF DWELLING SHALL BE TEMPERED. WINDOW SCHEDULE SIZE MARK DESCRIPTION W H MATERIAL AREA REMARKS W1 5040 HR 60" 48" ALUMINUM/GLASS 20.00 SQ.FT. N -1,2,4 NOTES: L G S SHALL BE CLEAR 5- SHGC 0.35 & U- FACTOR 0.65(glass) 47G F GLASS CATEGORY CLASS 2. S TYPE H DOTAL ROLLING DOOR SCHEDULE MARK DESCRIPTION SIZE w REMARKS W H T 7. EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM } P.T. 2x- WD. BUCK ATTACHED TO OPNG t w w� FRENCH DOOR 6' -0" 6' -8" - INSIDE THE CLOSET. MTL EXT. DOOR SAFETY NOTES FOR DOORS (CLOSETS AND BATHROOMS) NFPA 101 -1994 CHAPTER -21 (21- 2,4,3) EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM INSIDE THE CLOSET (21- 2.4.4) EVERY BATHROOM DOOR LOCK SHALL BE DESIGNED TO PERMIT THE OPENING OF THE LOCKED DOOR FROM THE EGRESS DOOR TYPE OF LOCK OR LATCH MUST COMPLY W /FBC R311.4.4. OUTSIDE IN AN EMERGENCY. EXTERIOR APPLICATIONS TYPICAL DOOR JAMB DETAIL _ 1 1/2" = 1 ° -0" _ co ° wE 8. EVERY BATHROOM DOOR LOCK SHALL BE DESIGNED TO PERMIT THE OPENING OF THE cc0 I— w �Z lct LOCKED DOOR FROM THE OUTSIDE IN AN EMERGENCY =U U O W r W 9. GLAZING ON EXTERIOR DOORS AND SIDELIGHTS SHALL BE CAT II SAFETY GLASS AS PER aW Ln� W cr) M 10 a� 2405.2 FBC. �z u a Q o Y 10. CAT. 11 SAFETY GLASS SHALL BE USED AT ALL SHOWERITUB ENCLOSURES INCLUDING o U) D N � Erg WINDOWS WITH SILLS LOWER THAN 60" AND MIRRORS IN THE TUB • • Ul a Uj "0 W o € 11. WALL AND CEILING FINISHES SHALL HAVE A FLAME- SPREAD CLASSIFICATION OF NOT Z> w O 00 0 GREATER THAN 200. FBC.R315.1 AND SHALL HAVE A SMOKE- DEVELOPED INDEX OF NOT GREATER THAN 450.FBC.R315.2 w o W j u- 4 b J LL lii d. Lf } N W • + O W W�nn — VJ R a ` O Z7 7 __ j Z _ 2 U) �m o 'Q .� W 0 _ = > EL IL W U STRUCTURAL S6CT'OC4 rl DWG. TITLE Q M Q � a WINDOW SCHEDULE SIZE MARK DESCRIPTION W H MATERIAL AREA REMARKS W1 5040 HR 60" 48" ALUMINUM/GLASS 20.00 SQ.FT. N -1,2,4 NOTES: L G S SHALL BE CLEAR 5- SHGC 0.35 & U- FACTOR 0.65(glass) 47G F GLASS CATEGORY CLASS 2. S TYPE H DOTAL ROLLING DOOR SCHEDULE MARK DESCRIPTION SIZE MATERIAL REMARKS W H T DOOR FRAME } P.T. 2x- WD. BUCK ATTACHED TO OPNG COLUMN WITH %4 " CORROSION w� FRENCH DOOR 6' -0" 6' -8" - MTL MTL EXT. DOOR SAFETY NOTES FOR DOORS (CLOSETS AND BATHROOMS) NFPA 101 -1994 CHAPTER -21 (21- 2,4,3) EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM INSIDE THE CLOSET (21- 2.4.4) EVERY BATHROOM DOOR LOCK SHALL BE DESIGNED TO PERMIT THE OPENING OF THE LOCKED DOOR FROM THE EGRESS DOOR TYPE OF LOCK OR LATCH MUST COMPLY W /FBC R311.4.4. OUTSIDE IN AN EMERGENCY. TERMITE PROTECTION AS PER F.B.C. 2007 AS SHOWN E DRAWN BY CHWD 105.10 CERTIFICATE OF PROTECTIVE TREATMENT FOR PREVENTION OF TERMITES. A WEATHER- RESISTANT JOB -SITE POSTING BOARD SHALL BE Luis A. HERRERA A.M PROVIDED TO RECEIVE DUPLICATE TREATMENT CERTIFICATES AS EACH REQUIRED PROTECTIVE TREATMENT IS COMPLETED, PROVIDING A COPY FOR THE PERSON THE PERMIT IS ISSUED TO AND ANOTHER COPY FOR THE BUILDING PERMIT FILES. THE TREATMENT CERTIFICATE SHALL PROVIDE THE PROJECT ND. PRODUCT USED, IDENTITY OF THE APPLICATOR, TIME AND DATE OF THE TREATMENT, SITE LOCATION, AREA TREATED, CHEMICAL USED, IF THE SOIL 201135 CHEMICAL BARRIER METHOD FOR TERMITE PREVENTION IS USED, FINAL EXTERIOR TREATMENT SHALL BE COMPLETED PRIOR TO FINAL BUILDING APPROVAL. DATE as -aa -11 105.11 NOTICE OF TERMITE PROTECTION. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR REINSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRIC PANEL. SHEET NUMBER A - n WOOD DOOR FRAME WITH (2) #10 WOOD TRIM PHILLIPS FLAT HEAD SCREW SPACING PER MFR. PRODUCT APPROVAL Y" GYPSUM BOARD 1x4 P.T. WD FURRING STRIPS CONT. AROUND } P.T. 2x- WD. BUCK ATTACHED TO OPNG COLUMN WITH %4 " CORROSION w� RESISTANT APPROVED CONCRETE CONCRETE OR MASONRY SCREW ANCHORS WITH MIN 1 -1/4" CONSTRUCTION EMBEDMENT. 6" FROM TOP & BOT. Uj SPACING @ 18" C/C MINIMUM 2 COAT STUCCO �� w j� FINISH (MIN %s "} SEALANT REQUIRED FOR Z a 61 � EXTERIOR APPLICATIONS TYPICAL DOOR JAMB DETAIL _ 1 1/2" = 1 ° -0" _ TERMITE PROTECTION AS PER F.B.C. 2007 AS SHOWN E DRAWN BY CHWD 105.10 CERTIFICATE OF PROTECTIVE TREATMENT FOR PREVENTION OF TERMITES. A WEATHER- RESISTANT JOB -SITE POSTING BOARD SHALL BE Luis A. HERRERA A.M PROVIDED TO RECEIVE DUPLICATE TREATMENT CERTIFICATES AS EACH REQUIRED PROTECTIVE TREATMENT IS COMPLETED, PROVIDING A COPY FOR THE PERSON THE PERMIT IS ISSUED TO AND ANOTHER COPY FOR THE BUILDING PERMIT FILES. THE TREATMENT CERTIFICATE SHALL PROVIDE THE PROJECT ND. PRODUCT USED, IDENTITY OF THE APPLICATOR, TIME AND DATE OF THE TREATMENT, SITE LOCATION, AREA TREATED, CHEMICAL USED, IF THE SOIL 201135 CHEMICAL BARRIER METHOD FOR TERMITE PREVENTION IS USED, FINAL EXTERIOR TREATMENT SHALL BE COMPLETED PRIOR TO FINAL BUILDING APPROVAL. DATE as -aa -11 105.11 NOTICE OF TERMITE PROTECTION. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR REINSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRIC PANEL. SHEET NUMBER A - n _. 0 � z ai 8 • r� as zZ of W w� m� �LL w �m Q Uj LL �� w j� Li. W Z a 61 � co I—� W w M w ce) ° wE Q cc0 I— w �Z U Ln b- Q W 0 =U `°° O 00 o� N 0Z ce) < aW Ln� 10 a� �z �'•' •;y /.. oN ol ;w :._ to <' pR 2+ iL3 o Erg Ul a Uj "0 W oz z w Z> w O �jz z o M r W W r, L(i z J LL lii d. Lf } N W • + O W W�nn — VJ F ` O Z7 7 __ j w M U r Q �m .j 1 _ry OT: sou BUILDING P . .� W 0 _ = > EL IL W U STRUCTURAL S6CT'OC4 DWG. TITLE FLOOR PLAN its V D BY'- SCALE TERMITE PROTECTION AS PER F.B.C. 2007 AS SHOWN E DRAWN BY CHWD 105.10 CERTIFICATE OF PROTECTIVE TREATMENT FOR PREVENTION OF TERMITES. A WEATHER- RESISTANT JOB -SITE POSTING BOARD SHALL BE Luis A. HERRERA A.M PROVIDED TO RECEIVE DUPLICATE TREATMENT CERTIFICATES AS EACH REQUIRED PROTECTIVE TREATMENT IS COMPLETED, PROVIDING A COPY FOR THE PERSON THE PERMIT IS ISSUED TO AND ANOTHER COPY FOR THE BUILDING PERMIT FILES. THE TREATMENT CERTIFICATE SHALL PROVIDE THE PROJECT ND. PRODUCT USED, IDENTITY OF THE APPLICATOR, TIME AND DATE OF THE TREATMENT, SITE LOCATION, AREA TREATED, CHEMICAL USED, IF THE SOIL 201135 CHEMICAL BARRIER METHOD FOR TERMITE PREVENTION IS USED, FINAL EXTERIOR TREATMENT SHALL BE COMPLETED PRIOR TO FINAL BUILDING APPROVAL. DATE as -aa -11 105.11 NOTICE OF TERMITE PROTECTION. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR REINSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRIC PANEL. SHEET NUMBER A - n