12-259R-005ELECTRICAL
LEGEND
SINGLE RECEPTACLE
4,710
SMALL APPLIANCES------ - - - - -- 3,000
REFRIGERATOR ---------------
1,000
SINGLE FLOOD - SOFFIT MOUNTED
DUPLEX RECEPTACLE
DISPOSAL-------------- - - - - --
800
WASHER--------------- - - - - --
750
DRYER---------------- - - - - --
® 220V RECEPTACLE
�DOUBLE
1,500
RANGE--------------- - - - - --
12,000
FLOOD - SOFFIT MOUNTED
SWITCHED RECEPTACLE
SPRINKLER PUMP------- - - - - --
COMPACT FLUOR. -
4 GROUND FAULT INT. OUTLET
48,260
CEILING MOUNTED
314
12,000
Z
❑S OCCUPANCY SENSOR
C. U.
COMPACT FLUOR. - WALL MOUNTED
WP WEATHERPROOF GROUND
30
LED PENDANT W/ GLASS DIFFUSER
AFCI ARC FAULT INTERRUPTER
5,000
Q M
GFI GROUND FAULT INTERRUPTER
O
RECESSED LED HIGH HAT
VP VAPOR PROOF
240
30
1
10
1
112
MS MOTION SENSOR
Q
RECESSED LED WALL WASHER
LS LIGHT SENSOR
TRACK LIGHT
24' UNDER CABINET T5 FLUOR.
20
12
112
QQQ
COMPACT FLUOR. - WALL MTD VANITY
EXHAUST FAN w /LIGHT
BATH 1, WIC LIGHTS & REC
U
120
$
SINGLE POLE SWITCH
EXHAUST FAN
• ••)
W
9
WH 1
3 WAY SWITCH
O O
70
DIMMER SWITCH (PROVIDE MAGNETIC
314
D
LOW VOLTAGE TYPE @ LV FIXTURES)
O CEILING FAN
$T
TIMER SWITCH
120
15
14
(/2 O
• •+
DISCONNECT SWITCH
12
O
O
CIRCULAR FLUORESCENT
CEILING FAN w /LIGHT
14
O O
TV
TV JACK
13
WASHER
COMPUTER OUTLET
0 ELECTRIC PANEL
DATA
(W/ GENERAL USE DUPLEX RECEPTICLE)
°O SMOKE DETECTOR /CARE. MON. DET.
-
PHONE JACK - PREWIRE ONLY
SD SMOKE DETECTOR /CARB. MEIN. DET.
BR 3, BATH 2 LT. & REC.
a
ELECTRICAL NOTES
1) CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND
EQUIPMENT FOR COMPLETE ELECTRICAL INSTALLATION IN ACCORDANCE
WITH THESE DRAWINGS.
2) COMPLY WITH THE N.E.C. AND STANDARD BUILDING CODE.
3) PROVIDE EMPTY CONDUITS AS REQUIRED FOR TELEPHONE SYSTEM.
4) OBTAIN ALL PERMITS FOR WORK UNDER THIS CONTRACT.
5) PROVIDE TEMPORARY POWER AND LIGHT OUTLETS FOR USE BY
OTHER TRADES.
6) PROVIDE ALL REQUIRED CONNECTIONS FOR OTHER TRADES.
7) COORDINATE ALL OUTLET LOCATIONS WITH BUILDING ARCHITECTURAL
FEATURES.
8) CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE HIMSELF WITH
ALL EXISTING CONDITIONS. 9) ALL CABLE SHALL BE COPPER.
10) INDOOR CONDUITS SHALL BE EMT.
1 1) ALL MOUNTING HARDWARE SHALL BE BY CONTRACTOR.
12) OUTDOOR UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC.
UNDER PAVED AREAS IT SHALL BE ENCASED IN CONCRETE. MINIMUM
COVER SHALL BE 24 INCHES.
CONTROL WIRING TO OTHER
SMOKE DETECTORS INSIDE UNIT
SD
SMOKE
120 V.
SWITCH LEG PHASE COND.
S. D. SWITCH LINE DIDE
OF SWITCH
SMOKE DETECTOR DIAGRAM
SCALE N.T.S.
N OTE
1. SMOKE DETECTORS SHALL BE HARDWIRE (110
VOLT TYPE) TO A NON SWITCH ABLE KITCHEN OR
BATHROOM LIGHTING CIRCUIT WITH BATTERY
BACK UP AND SHALL NOT BE CONNECTED ONTO
THE LOAD SIDE OF GROUND FAULT CIRCUIT
INTERRUPTER ALL SMOKE DETECTORS WITHIN
EACH UNIT SHALL BE INTERCONNECTED.
2. SMOKE DETECTORS SHALL NOT BE
PLACED WITHIN 3 FT OF ANY A/C GRILL OR BATH DR
3. PROVIDE ARC -FAULT CIRCUIT INTERRUPTER
PROTECTION FOR ALL 15 AND 20 AMP 125 VOLT
BEDROOM BRANCH CIRCUIT OUTLETS. NEC
210 -12
NOTE:
ELEC. CONTR. HAS OPTION OF METHOD A] RUNNING ROMEX
W/ PROTECTION PLATES IN CHANNEL TO BE CUT THROUGH
POLYSTYRENE EXT. WALLS OR [METHOD B] IN CONDUIT RUN
UNDER SLAB AND UP TO DEVICES W/ BOXES MOUNTED PRIOR
TO POURING CONCRETE IN ICF WALLS. METHOD A: ROMEX
WOULD BE SECURED TO PLASTIC ICF TIES LOCATED AT 6" ON
CENTER ® 518" BEHIND SURFACE OF POLYSTYRENE. DRYWALL
WILL BE INSTALLED DIRECTLY ON ICF BLOCKS. ALL ELEC.
BOXES MUST BE ATTACHED TO CONCRETE LOCATED 1 718"
BEHIND SURFACE OF POLYSTYRENE. BOXES MUST NOT BE
DEEPER THAN 2 318 ". METHOD B: ALL DEVICE BOXES CUT
INTO ICF BLOCKS PRIOR TO CONCRETE POUR MUST BE
SECURELY BRACED TO RESIST PRESSURE OF WET CONCRETE.
ELECTRICAL LOAD
CALCULATI ❑N NEW PANEL "A"
SQ. FT, -------------- - - - - --
1,570
GENERAL LIGHTING (3W, /S,F,) - --
4,710
SMALL APPLIANCES------ - - - - -- 3,000
REFRIGERATOR ---------------
1,000
DISHWASHER----------- - - - - --
500
DISPOSAL-------------- - - - - --
800
WASHER--------------- - - - - --
750
DRYER---------------- - - - - --
6,800
MICROWAVE------------ - - - - --
1,500
RANGE--------------- - - - - --
12,000
WATER HEATER--------- - - - - --
16,000
SPRINKLER PUMP------- - - - - --
1,200
240
48,260
CONNECTED LOAD: (LESS A /C) -- 48,260
FIRST 1OKW @ 100 %----- - - - - --
10,000
BAL. @ 40%----------- - - - - --
15,304
A/C OR HTG. @ 100 %---- - - - - --
8,040
DEMAND LOAD: -------------
33,344
AMPS @ 240/12OV. 1PH.- - - - - --
-139 AMP
PANEL / MCB -------- - - - - --
-200 AMP,
USE
SPEC
NOTES
ALL SMOKE DETECTORS SHOULD BE NOT LESS
S -0" FROM A/C GRILLS & RELOCATED IF
COND
SIZE
NECESARY.
q C
3
WET LOCATION NOTES:
1. ALL ELECT. EQUIP. EXPOSED TO WEATHER
SHALL COMPLY TO NEC 373 -2 (A)
2. SWITCHES OR CIRCUIT BREAKERS
IN WET LOCATION OR OUTSIDE OF
A BUILDING SHALL BE ENCLOSED
IN A WEATHERPROOF ENCLOSURE
OR CABINET. PER NEC 380 -4
3. NO SWITCHES SHALL BE INSTALLED
WITHIN WET LOCATION
GENERAL NOTES
Eocaffm sea plan NEW PANEL 'A" Main BLS 200 AMP 32 SPACE 40 CFKW CAE
Voltage: 120 1240 v, 1#,3W Main Breaker METER COMBO (MCB)
Mota11V RECESSED A)C� 10,000
Gn= Ground Fault Interrupter NCL= Non — concurrent load REC= Receptacle Ckt Lts= Lighting Ckt ST= Breaker with shunt trip T =Via timer
IS= Isolated ground Ckt C= Via contactor SWD= On —Off Switching Duty rated breaker,as per NEC 240 -83(d) LV= Via low voltage transformer
HACR= Breaker suitable for the protection of heating, A/C and refrigeration equipment
Ckt
No.
USE
SPEC
VOLT
BKR
AMP
WIRE
COND
SIZE
VA
PHASE
Ckt
No.
USE
SPEC
VOLT
BKR
AMP
WIRE
COND
SIZE
VA
q C
3
RANGE
LLJ
240
50
6
314
12,000
Z
C. U.
240
30
10
314
5,000
Q M
4
5
DRYER
240
30
1
10
1
112
6,800
o
Z
6
REFRIGERATOR
W
120
20
12
112
800
71
8
BATH 1, WIC LIGHTS & REC
U
120
15
14
112
• ••)
W
9
WH 1
.
240
70
4
314
11,800
1
=
10
MBR LIGHT & REC.
120
15
14
1 2
• •+
11
12
BR 2, HALL, UTIL, LT. &REC.
M
120
15
14
112
+(••)
LL.
13
WASHER
120
20
12
112
750
14
BR 3, BATH 2 LT. & REC.
a
120
15
14
112
•( + +)
15
BATH 1 GF1
120
20
12
112
16
BATH 2 GFI
—ate
120
20
12
112
17
GARBAGE DISPOSAL
120
20
12
112
Boo
W
18
KITCHEN, FOYER LT. & REC
C
Z
120
15
14
112
•(••)
19
DISHWASHER
120
20
12
112
50o
20
DINING, GR. LIGHT & REC
120
20
12
112
+(••)
21
SMALL APPLIANCE
120
20
12
712
1500
22
SPARE
23
SMALL APPLIANCE
120
20
12
112
1500
24
EXTERIOR LIGHTS & REC
120
20
12
112
•
25
MICROWAVE
120
20
12
112
1000
26
SPARE
240
40
8
314
8,040
28
WH 2
220
25
10
112
4,200
229
311
SPARE
I
1
32
SPARE
( *) AS PER SQ -FT OF CONDITION SPACE
** ARC FAULT CIRCUIT INTERRUPTER PROTECTION
1. PROVIDE EXPANSION JOINTS FITTINGS TO CONDUITS CROSSING
STRUCTURAL EXPANSION JOINTS.
2. PROVIDE PULL WIRES IN TELEPHONE AND ALL EMPTY
CONDUIT SYSTEMS.
3. ALL CONDUCTORS SHALL BE COPPER.
4. ALL CONTROL WIRES AND CONNECTIONS REQUIRED FOR AIR
CONDITIONING AND VENTILATING EQUIPMENT OPERATION SHALL
BE PROVIDED. REFER TO MECHANICAL DRAWING.
5. LOCATION OF OUTLETS IN ELECTRICIAN DRAWINGS IS
DIAGRAMMATIC. CHECK ARCHITECTURAL DRAWINGS FOR EXACT
LOCATION OF OUTLETS. ADJUST OUTLET LOCATIONS TO AVOID
INTERFERENCE WITH OTHER TRADES.
6. LOCATION OF SWITCHES VARIES WITH THE DOOR SWING:
FOLLOW ARCHITECTURAL DRAWINGS IN EACH CASE.
7. CLAIMS FOR EXTRA WORK REQ'D TO MEETCODE REQUIREMENTS
WILL NOT BE CONSIDERED.
8. AMONG ELECTRICAL CONTRACTOR'S RESPONSIBILITIES THERE
SHALL BE:
8.1 - TO VERIFY ACTUAL FIELD CONDITIONS PRIOR BIDDING.
ONCE THE AMOUNT OF WORK INVOLVED HAS BEEN DETERMINED,
THE CONTRACTOR SHALL INCLUDE IN HIS BID ALL NECESSARY
PARTS AND LABOR REQUIRED TO COMPLETE A SAFE AND
CORRECT ELECTRICAL INSTALLATION.
8.2 - TO PROVIDE ADEQUATE WIRING, BREAKER OR SWITCH
PROTECTION TO CONFORM WITH FURNISHED EQUIPMENT WITHOUT
EXTRA COST TO THE OWNER.
8.3 - TO CONTACT F.P.L. COMPANY'S REPRESENTATIVE TO
DETERMINE FINAL UNDERGROUND PRIMARY CONDUITS ROUTING AND
TO INSTALL THEM AS PER F.P.L. COMPANY'S STANDARDS.
8.4 TO CONTACT TELEPHONE COMPANY'S REPRESENTATIVE TO
DETERMINE FINAL ROUTING UNDERGROUND CONDUITS FOR
TELEPHONE SUPPLY AND TO INSTALL THEM AS PER THE
COMPANY'S STANDARDS.
8.5 TO VERIFY EXISTING UTILITIES FACILITIES PRIOR
TRENCHING.
8.6 TO COORDINATE, PRIOR TO CONSTRUCTION, WITH
MECHANICAL AND PLUMBING SUBCONTRACTORS REGARDING SPACE
REQUIRED FOR FULL INSTALLATION. AND POSSIBLE CONFLICTS.
9. ALL 15 AND 20 AMP OUTLETS IN FAMILY ROOM, DINING ROOM, LIVING
ROOM, BEDROOMS, CLOSETS, HALLWAY TO BE PROTECTED BY A LISTED ARC
FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE.
10. ALL OUTLETS TO BE TAMPLER PROOF TYPE
Q,-V-
P Ms A 2 4
VP
A24
L mLU
_IA24
TO FPL U.P.
TO FPL
3 #210 THWN (Cu)
IN 2" COND.
RUNNING FROM
F.P.L. SERVICE POINT.
WEATHER HEAD
ELEC.
METER
O
200A
MCB
1 # 4 THWN (Cu)
IN 3/4" COND.
GRADE LEVEL
EXTERIOR
INTERIOR
-
Z
Q
ELECT.
cl):
Q
PANEL A
HOSE BIBB I
3I'r
_111 4 "o
PITCH POCKET /CAP
314" EMT TO ROOF
FOR FUTURE SOLAR
TERMINATE +4FT AFF
314" EMT TO UTIL. RM.
FOR FUTURE SOLAR
3 #210 THWN (Cu)
1#6 THWN (Cu) G
IN 2" COND.
ROD 10'-0" DEEP GR D� UN NEW #4 IN 1/2" CONDUIT
—_L TO (2) 5/8" X 10 FT GROUND
RODS 0 MIN. 6 FT APART
ELECTRICAL RISER DIAGRAM
A27,29 A24
44— _ 40A NEMA TYPE 3R A24 G
VP �s VP
db 1 I
TV
\�A8 Al2 /
kA16 VP 6IIPFGOM 2 /
A8
� MASTE;C? O
3 T �AtN °
Al2 Alt
A10 SD A16,
A 12 /
\ Al2
Al2 P
NL L 'A�
`\ \ A10 / Al2 i — — i Al2
` A8\ 1 I L — — J U11�11Y t7p00M I SD - - - -- - -- - - - -Z��
Ls A24
� � J
A20 /
SCALE: 1/4"=—V-0"
1
S , (—
N.T.S.
_
a_
-
Z
Q
cl):
Q
E=
W^
Q
LLJ
0
_
ca
Z f1
Z
J
Q M
U.
Z
Z
a°o
W
W
CD
4-
o
Z
M
I
W
W
NcL`J
co
Uj
W
U
Z
O
=
O
Q
W
Cc
LU
.
LL
>
m
O
=
a�aao
I—
M
O
O
1
06
p
M
LL.
0
U.
-j
a
o
a
Cl)
C4
o<
W
—ate
W
W
..
C
Z
cl
Q
O
O
_ • yV � i
.[
ww
aw � :
o
�► �� 6:
j ••�..
,I',',���1111111i111111�`
IMRIIAt1i Nil OONr1 ANo
UWU , Naa W UK AFAMM H
!Mt MAY NOT t OIN11011 11�
on COMA= •111018 NAfT�I W 1K
JOB No.:
12.06487 . S FR
REVISIONS:
Al 6-17-13 CU
DATE: 3/5/2012
CHECKED BY:
DRAWN BY: SRL
PLOT.. 100%
SHEET INDEX:
ELECTRICAL PLAN
NOTE
SHEET No.:
E -1
a_
Q
Q
L0
M
LLJ
ca
Z f1
CD
CD
J
Q M
Q
Z
a°o
W
CD
4-
o
Z
M
I
NcL`J
Uj
W
U
~
V
O
C /� /
Cc
_ • yV � i
.[
ww
aw � :
o
�► �� 6:
j ••�..
,I',',���1111111i111111�`
IMRIIAt1i Nil OONr1 ANo
UWU , Naa W UK AFAMM H
!Mt MAY NOT t OIN11011 11�
on COMA= •111018 NAfT�I W 1K
JOB No.:
12.06487 . S FR
REVISIONS:
Al 6-17-13 CU
DATE: 3/5/2012
CHECKED BY:
DRAWN BY: SRL
PLOT.. 100%
SHEET INDEX:
ELECTRICAL PLAN
NOTE
SHEET No.:
E -1