12-259R-005ELECTRICAL LEGEND SINGLE RECEPTACLE 4,710 SMALL APPLIANCES------ - - - - -- 3,000 REFRIGERATOR --------------- 1,000 SINGLE FLOOD - SOFFIT MOUNTED DUPLEX RECEPTACLE DISPOSAL-------------- - - - - -- 800 WASHER--------------- - - - - -- 750 DRYER---------------- - - - - -- ® 220V RECEPTACLE �DOUBLE 1,500 RANGE--------------- - - - - -- 12,000 FLOOD - SOFFIT MOUNTED SWITCHED RECEPTACLE SPRINKLER PUMP------- - - - - -- COMPACT FLUOR. - 4 GROUND FAULT INT. OUTLET 48,260 CEILING MOUNTED 314 12,000 Z ❑S OCCUPANCY SENSOR C. U. COMPACT FLUOR. - WALL MOUNTED WP WEATHERPROOF GROUND 30 LED PENDANT W/ GLASS DIFFUSER AFCI ARC FAULT INTERRUPTER 5,000 Q M GFI GROUND FAULT INTERRUPTER O RECESSED LED HIGH HAT VP VAPOR PROOF 240 30 1 10 1 112 MS MOTION SENSOR Q RECESSED LED WALL WASHER LS LIGHT SENSOR TRACK LIGHT 24' UNDER CABINET T5 FLUOR. 20 12 112 QQQ COMPACT FLUOR. - WALL MTD VANITY EXHAUST FAN w /LIGHT BATH 1, WIC LIGHTS & REC U 120 $ SINGLE POLE SWITCH EXHAUST FAN • ••) W 9 WH 1 3 WAY SWITCH O O 70 DIMMER SWITCH (PROVIDE MAGNETIC 314 D LOW VOLTAGE TYPE @ LV FIXTURES) O CEILING FAN $T TIMER SWITCH 120 15 14 (/2 O • •+ DISCONNECT SWITCH 12 O O CIRCULAR FLUORESCENT CEILING FAN w /LIGHT 14 O O TV TV JACK 13 WASHER COMPUTER OUTLET 0 ELECTRIC PANEL DATA (W/ GENERAL USE DUPLEX RECEPTICLE) °O SMOKE DETECTOR /CARE. MON. DET. - PHONE JACK - PREWIRE ONLY SD SMOKE DETECTOR /CARB. MEIN. DET. BR 3, BATH 2 LT. & REC. a ELECTRICAL NOTES 1) CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT FOR COMPLETE ELECTRICAL INSTALLATION IN ACCORDANCE WITH THESE DRAWINGS. 2) COMPLY WITH THE N.E.C. AND STANDARD BUILDING CODE. 3) PROVIDE EMPTY CONDUITS AS REQUIRED FOR TELEPHONE SYSTEM. 4) OBTAIN ALL PERMITS FOR WORK UNDER THIS CONTRACT. 5) PROVIDE TEMPORARY POWER AND LIGHT OUTLETS FOR USE BY OTHER TRADES. 6) PROVIDE ALL REQUIRED CONNECTIONS FOR OTHER TRADES. 7) COORDINATE ALL OUTLET LOCATIONS WITH BUILDING ARCHITECTURAL FEATURES. 8) CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. 9) ALL CABLE SHALL BE COPPER. 10) INDOOR CONDUITS SHALL BE EMT. 1 1) ALL MOUNTING HARDWARE SHALL BE BY CONTRACTOR. 12) OUTDOOR UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC. UNDER PAVED AREAS IT SHALL BE ENCASED IN CONCRETE. MINIMUM COVER SHALL BE 24 INCHES. CONTROL WIRING TO OTHER SMOKE DETECTORS INSIDE UNIT SD SMOKE 120 V. SWITCH LEG PHASE COND. S. D. SWITCH LINE DIDE OF SWITCH SMOKE DETECTOR DIAGRAM SCALE N.T.S. N OTE 1. SMOKE DETECTORS SHALL BE HARDWIRE (110 VOLT TYPE) TO A NON SWITCH ABLE KITCHEN OR BATHROOM LIGHTING CIRCUIT WITH BATTERY BACK UP AND SHALL NOT BE CONNECTED ONTO THE LOAD SIDE OF GROUND FAULT CIRCUIT INTERRUPTER ALL SMOKE DETECTORS WITHIN EACH UNIT SHALL BE INTERCONNECTED. 2. SMOKE DETECTORS SHALL NOT BE PLACED WITHIN 3 FT OF ANY A/C GRILL OR BATH DR 3. PROVIDE ARC -FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL 15 AND 20 AMP 125 VOLT BEDROOM BRANCH CIRCUIT OUTLETS. NEC 210 -12 NOTE: ELEC. CONTR. HAS OPTION OF METHOD A] RUNNING ROMEX W/ PROTECTION PLATES IN CHANNEL TO BE CUT THROUGH POLYSTYRENE EXT. WALLS OR [METHOD B] IN CONDUIT RUN UNDER SLAB AND UP TO DEVICES W/ BOXES MOUNTED PRIOR TO POURING CONCRETE IN ICF WALLS. METHOD A: ROMEX WOULD BE SECURED TO PLASTIC ICF TIES LOCATED AT 6" ON CENTER ® 518" BEHIND SURFACE OF POLYSTYRENE. DRYWALL WILL BE INSTALLED DIRECTLY ON ICF BLOCKS. ALL ELEC. BOXES MUST BE ATTACHED TO CONCRETE LOCATED 1 718" BEHIND SURFACE OF POLYSTYRENE. BOXES MUST NOT BE DEEPER THAN 2 318 ". METHOD B: ALL DEVICE BOXES CUT INTO ICF BLOCKS PRIOR TO CONCRETE POUR MUST BE SECURELY BRACED TO RESIST PRESSURE OF WET CONCRETE. ELECTRICAL LOAD CALCULATI ❑N NEW PANEL "A" SQ. FT, -------------- - - - - -- 1,570 GENERAL LIGHTING (3W, /S,F,) - -- 4,710 SMALL APPLIANCES------ - - - - -- 3,000 REFRIGERATOR --------------- 1,000 DISHWASHER----------- - - - - -- 500 DISPOSAL-------------- - - - - -- 800 WASHER--------------- - - - - -- 750 DRYER---------------- - - - - -- 6,800 MICROWAVE------------ - - - - -- 1,500 RANGE--------------- - - - - -- 12,000 WATER HEATER--------- - - - - -- 16,000 SPRINKLER PUMP------- - - - - -- 1,200 240 48,260 CONNECTED LOAD: (LESS A /C) -- 48,260 FIRST 1OKW @ 100 %----- - - - - -- 10,000 BAL. @ 40%----------- - - - - -- 15,304 A/C OR HTG. @ 100 %---- - - - - -- 8,040 DEMAND LOAD: ------------- 33,344 AMPS @ 240/12OV. 1PH.- - - - - -- -139 AMP PANEL / MCB -------- - - - - -- -200 AMP, USE SPEC NOTES ALL SMOKE DETECTORS SHOULD BE NOT LESS S -0" FROM A/C GRILLS & RELOCATED IF COND SIZE NECESARY. q C 3 WET LOCATION NOTES: 1. ALL ELECT. EQUIP. EXPOSED TO WEATHER SHALL COMPLY TO NEC 373 -2 (A) 2. SWITCHES OR CIRCUIT BREAKERS IN WET LOCATION OR OUTSIDE OF A BUILDING SHALL BE ENCLOSED IN A WEATHERPROOF ENCLOSURE OR CABINET. PER NEC 380 -4 3. NO SWITCHES SHALL BE INSTALLED WITHIN WET LOCATION GENERAL NOTES Eocaffm sea plan NEW PANEL 'A" Main BLS 200 AMP 32 SPACE 40 CFKW CAE Voltage: 120 1240 v, 1#,3W Main Breaker METER COMBO (MCB) Mota11V RECESSED A)C� 10,000 Gn= Ground Fault Interrupter NCL= Non — concurrent load REC= Receptacle Ckt Lts= Lighting Ckt ST= Breaker with shunt trip T =Via timer IS= Isolated ground Ckt C= Via contactor SWD= On —Off Switching Duty rated breaker,as per NEC 240 -83(d) LV= Via low voltage transformer HACR= Breaker suitable for the protection of heating, A/C and refrigeration equipment Ckt No. USE SPEC VOLT BKR AMP WIRE COND SIZE VA PHASE Ckt No. USE SPEC VOLT BKR AMP WIRE COND SIZE VA q C 3 RANGE LLJ 240 50 6 314 12,000 Z C. U. 240 30 10 314 5,000 Q M 4 5 DRYER 240 30 1 10 1 112 6,800 o Z 6 REFRIGERATOR W 120 20 12 112 800 71 8 BATH 1, WIC LIGHTS & REC U 120 15 14 112 • ••) W 9 WH 1 . 240 70 4 314 11,800 1 = 10 MBR LIGHT & REC. 120 15 14 1 2 • •+ 11 12 BR 2, HALL, UTIL, LT. &REC. M 120 15 14 112 +(••) LL. 13 WASHER 120 20 12 112 750 14 BR 3, BATH 2 LT. & REC. a 120 15 14 112 •( + +) 15 BATH 1 GF1 120 20 12 112 16 BATH 2 GFI —ate 120 20 12 112 17 GARBAGE DISPOSAL 120 20 12 112 Boo W 18 KITCHEN, FOYER LT. & REC C Z 120 15 14 112 •(••) 19 DISHWASHER 120 20 12 112 50o 20 DINING, GR. LIGHT & REC 120 20 12 112 +(••) 21 SMALL APPLIANCE 120 20 12 712 1500 22 SPARE 23 SMALL APPLIANCE 120 20 12 112 1500 24 EXTERIOR LIGHTS & REC 120 20 12 112 • 25 MICROWAVE 120 20 12 112 1000 26 SPARE 240 40 8 314 8,040 28 WH 2 220 25 10 112 4,200 229 311 SPARE I 1 32 SPARE ( *) AS PER SQ -FT OF CONDITION SPACE ** ARC FAULT CIRCUIT INTERRUPTER PROTECTION 1. PROVIDE EXPANSION JOINTS FITTINGS TO CONDUITS CROSSING STRUCTURAL EXPANSION JOINTS. 2. PROVIDE PULL WIRES IN TELEPHONE AND ALL EMPTY CONDUIT SYSTEMS. 3. ALL CONDUCTORS SHALL BE COPPER. 4. ALL CONTROL WIRES AND CONNECTIONS REQUIRED FOR AIR CONDITIONING AND VENTILATING EQUIPMENT OPERATION SHALL BE PROVIDED. REFER TO MECHANICAL DRAWING. 5. LOCATION OF OUTLETS IN ELECTRICIAN DRAWINGS IS DIAGRAMMATIC. CHECK ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF OUTLETS. ADJUST OUTLET LOCATIONS TO AVOID INTERFERENCE WITH OTHER TRADES. 6. LOCATION OF SWITCHES VARIES WITH THE DOOR SWING: FOLLOW ARCHITECTURAL DRAWINGS IN EACH CASE. 7. CLAIMS FOR EXTRA WORK REQ'D TO MEETCODE REQUIREMENTS WILL NOT BE CONSIDERED. 8. AMONG ELECTRICAL CONTRACTOR'S RESPONSIBILITIES THERE SHALL BE: 8.1 - TO VERIFY ACTUAL FIELD CONDITIONS PRIOR BIDDING. ONCE THE AMOUNT OF WORK INVOLVED HAS BEEN DETERMINED, THE CONTRACTOR SHALL INCLUDE IN HIS BID ALL NECESSARY PARTS AND LABOR REQUIRED TO COMPLETE A SAFE AND CORRECT ELECTRICAL INSTALLATION. 8.2 - TO PROVIDE ADEQUATE WIRING, BREAKER OR SWITCH PROTECTION TO CONFORM WITH FURNISHED EQUIPMENT WITHOUT EXTRA COST TO THE OWNER. 8.3 - TO CONTACT F.P.L. COMPANY'S REPRESENTATIVE TO DETERMINE FINAL UNDERGROUND PRIMARY CONDUITS ROUTING AND TO INSTALL THEM AS PER F.P.L. COMPANY'S STANDARDS. 8.4 TO CONTACT TELEPHONE COMPANY'S REPRESENTATIVE TO DETERMINE FINAL ROUTING UNDERGROUND CONDUITS FOR TELEPHONE SUPPLY AND TO INSTALL THEM AS PER THE COMPANY'S STANDARDS. 8.5 TO VERIFY EXISTING UTILITIES FACILITIES PRIOR TRENCHING. 8.6 TO COORDINATE, PRIOR TO CONSTRUCTION, WITH MECHANICAL AND PLUMBING SUBCONTRACTORS REGARDING SPACE REQUIRED FOR FULL INSTALLATION. AND POSSIBLE CONFLICTS. 9. ALL 15 AND 20 AMP OUTLETS IN FAMILY ROOM, DINING ROOM, LIVING ROOM, BEDROOMS, CLOSETS, HALLWAY TO BE PROTECTED BY A LISTED ARC FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE. 10. ALL OUTLETS TO BE TAMPLER PROOF TYPE Q,-V- P Ms A 2 4 VP A24 L mLU _IA24 TO FPL U.P. TO FPL 3 #210 THWN (Cu) IN 2" COND. RUNNING FROM F.P.L. SERVICE POINT. WEATHER HEAD ELEC. METER O 200A MCB 1 # 4 THWN (Cu) IN 3/4" COND. GRADE LEVEL EXTERIOR INTERIOR - Z Q ELECT. cl): Q PANEL A HOSE BIBB I 3I'r _111 4 "o PITCH POCKET /CAP 314" EMT TO ROOF FOR FUTURE SOLAR TERMINATE +4FT AFF 314" EMT TO UTIL. RM. FOR FUTURE SOLAR 3 #210 THWN (Cu) 1#6 THWN (Cu) G IN 2" COND. ROD 10'-0" DEEP GR D� UN NEW #4 IN 1/2" CONDUIT —_L TO (2) 5/8" X 10 FT GROUND RODS 0 MIN. 6 FT APART ELECTRICAL RISER DIAGRAM A27,29 A24 44— _ 40A NEMA TYPE 3R A24 G VP �s VP db 1 I TV \�A8 Al2 / kA16 VP 6IIPFGOM 2 / A8 � MASTE;C? O 3 T �AtN ° Al2 Alt A10 SD A16, A 12 / \ Al2 Al2 P NL L 'A� `\ \ A10 / Al2 i — — i Al2 ` A8\ 1 I L — — J U11�11Y t7p00M I SD - - - -- - -- - - - -Z�� Ls A24 � � J A20 / SCALE: 1/4"=—V-0" 1 S , (— N.T.S. _ a_ - Z Q cl): Q E= W^ Q LLJ 0 _ ca Z f1 Z J Q M U. Z Z a°o W W CD 4- o Z M I W W NcL`J co Uj W U Z O = O Q W Cc LU . LL > m O = a�aao I— M O O 1 06 p M LL. 0 U. -j a o a Cl) C4 o< W —ate W W .. C Z cl Q O O _ • yV � i .[ ww aw � : o �► �� 6: j ••�.. ,I',',���1111111i111111�` IMRIIAt1i Nil OONr1 ANo UWU , Naa W UK AFAMM H !Mt MAY NOT t OIN11011 11� on COMA= •111018 NAfT�I W 1K JOB No.: 12.06487 . S FR REVISIONS: Al 6-17-13 CU DATE: 3/5/2012 CHECKED BY: DRAWN BY: SRL PLOT.. 100% SHEET INDEX: ELECTRICAL PLAN NOTE SHEET No.: E -1 a_ Q Q L0 M LLJ ca Z f1 CD CD J Q M Q Z a°o W CD 4- o Z M I NcL`J Uj W U ~ V O C /� / Cc _ • yV � i .[ ww aw � : o �► �� 6: j ••�.. ,I',',���1111111i111111�` IMRIIAt1i Nil OONr1 ANo UWU , Naa W UK AFAMM H !Mt MAY NOT t OIN11011 11� on COMA= •111018 NAfT�I W 1K JOB No.: 12.06487 . S FR REVISIONS: Al 6-17-13 CU DATE: 3/5/2012 CHECKED BY: DRAWN BY: SRL PLOT.. 100% SHEET INDEX: ELECTRICAL PLAN NOTE SHEET No.: E -1