12-259R-004REFRIGERATION PIPING
6 IN. PIPE INSULATION
FLP
I -II I I =1 -III -I -I III =III =III =�
-1 -11 1III1
PVC SCHD. 40
CONTINUOUS
BENDS ® 45' ELBOW EEVE
_ �_ = 1I-
REFRIGERANT PIPE DETAIL
SCALE: N.T.S.
AIR DUCT
SPACE
REFRIGERATION
LINES -
FILTER /FAN
ACCESS
PANEL
1 1/4" P.V.C.
COND. DRAIN W/
TRAP AND UNION
W/ CLEANOUT
NEW
REFRIGERANT
LINE 1"
4/M -1
STUDS ® 24" O.C.
HEATER
ACCESS
PANEL
COIL
ACCESS
PANEL
— PROVIDE METAL SUPPORT BY
OTHER
PROVIDE LOW VOLTAGE CONS.
OVERFLOW SHUT -OFF SAFETY
SWITCH MODEL # S52 BY SMD
RESERCH INC. FLOAT SWITCH
A/C CLOSET I N STALLATI O1
SCALE: N.T.S.
2 -1/4" TURNBUCKLES
SS MODEL # 17485
LOAD 160 LBS.
CONDENSING UNIT —
1/4" WIRE /ROPE
CLAMPS GROOVED
CLAMPS HOLDS CABLES
6" CONC. CAST
IN PLACE ® SAME
HEIGHT AS MAIN
FLOOR LSUCTION LINE W/ 1/2"
CHAIN LINK, 1/4"
1/4" STOCK
2-1/4" LONG
MODEL 12895
5/16 "X4" LAG EYEBOLTS
SS ® EACH CABLE END
CONDENSING UNIT DETAIL
DETAIL
NOTE:
BOLT CONDENSING UNIT TO CONC. PAD TO
WITHSTAND 146 MPH HURRICANE FORCE WINDS.
1/4" SS COATED CABLE
- -- SECURE PER DADE
COUNTY ORD. 8 C -5
ELEC. POWER SUPPLY
CONNECTIONS
LIQUID LINE W/0
INSULATION
1 "X3" 22 GA SHT
SELF TAP SCREW
DUCT TO AHU
SCALE: N.T.S.
LOW VELOCITY SUPPLY
MTL ROUND FITTING
QUADRANT OPERATOR
TO BE OUTSIDE
INSULATION PROVIDE
INSULATION GUARD
AS REQUIRED
R -6 INSULATED
FLEXIBLE DUCT
SEAL ALL
JOINTS
W/ MASTIC
PERFORATED
DIFFUSER
SCALE: N.T.S.
FIBERGLAS DUCT
2 1/2" SQ. WASHER
0 12" O.C. MIN. 2 /SIDE
#10 X 1 1/4" SHT. MTL SCREW
M CLOSURE
Z HANDLER
PROVIDE 1" METAL STRAP
GAUGE 16 FOR ALL DUCT
HANGER INSIDE ATTIC.
ATTACHED TO STRUCTURE W/
BOLTED CONN. PROVIDE 1"
SHEET METAL BAND CLAMP
ATTACH TO STRUCTURE W /10d
NAILS
1 1/2" FORMED SHEET METAL GAUGE
16 BAND CLAMP
EXHAUST FAN SCHEDULE
TYPE
DUCT
VERT.
NUTONE MODEL # 606
ENERGY STAR
SIZE 4"
DISCHARGE 50 CFM
- SLOPED ROOF
CAP.
—WIRE MESH TERMINATION
iROOF
4" METAL
DUCT
ARMAFLEX INSULATION EXH.
& VAPOR BARRIOR FAN
WITH /D
LIQUID &SUCTION PIPING IS ABOVE - -- - - - - - -- - - -- — — — - -
GRADE, SEE PLAN.
PROVIDE ANCHORED BOLTS TO PREVENT C EI LI N G�
THEFT PER DADE COUNTY ORD. 8C -5
R AIR
AI
GRILLE
SCALE: N.T.S.
SEAL GAP BETWEEN
SLEEVE AND DUCT W/
EXPANSION FOAM AND
CAULK TO DRYWALL
VENT DUCT 4" DIA.
AL. 26 GA. MIN. SHEET METAL
DUCT. UL /81 CLASS
DRYER
4" FLEX DUCT
HOSE CLAMP
CONDENSING UNIT
SCALE: N.T.S.
R -6 FLEX DUCT AIR
INTAKE - DUCT SIZE
PER MECH. PLAN.
CONNECT OA DUCT
TO AHU RA INTAKE
SCALE: N.T.S.
LOUVERED VENT COVER
W/ NO SCREEN -
SCREW TO 2X4 BLKG
BEHIND STUCCO
4 1/2" MIN. DIA. HOLE
THROUGH ICF SYSTEM -
- G.C. TO BLOCK OUT HOLE
BEFORE POURING
CONCRETE
DETAIL
TRANSITION TO
4 "X8" SS DUCT
THRU SOFFIT
FAMCO 6" GALV. DAMPER
WALL VENT W/ J" INSECT
SCREEN & EXTRA LONG
THROAT. VERIFY DIRECTION
OF BDD SET TO INTAKE -
COORDINATE INSTALLATION
W/ ICF INSTALLER -
PROVIDE SLEEVE THRU
CONCRETE
SCALE: N.T.S.
GENERAL H.V.A.C. NOTES
1. The contractor shall furnish all labor, material and equipment
for a complete H.V.A.C. system in accordance with these drawings.
The Florida Building Code 2007/2009 and the latest edition of the
following publications:
(o)ANS 89.1 Mechanical Refrigeration (b) NFPA Pamphlets 90A & 91
(c) SMACNA (d) ASHRAE.
2. All air conditioning ductwork shall be 1 112 " standard duty
foil reinforced fiberglass (R -6) manufactured logo printed on the
vapor barrier.
3. All exhaust ductwork shall be code gage galvanized sheet metal.
4. Duct sizes shown are net free area inside.
5. All air devices (diffusers, registers and grilles) shall be all
aluminum construction, with exposed surface chemically treated to
receive paint to match color or AIRGUIDE or approved equal.
with minimum 7590 free area.
6. Provide opposed blade dampers at all diffusers and registers.
7. Thermostats shall be combination cooling /heating with system
Cool /Auto /Heat /Off and Fan On /Auto selector switches.
8. Refrigerant piping shall be copper type "L" with 314" ormoflex.
Insulation shall be provided for suction lines.
9. Provide new filters for fan coil before starting. These
filters must also be replaced prior to final acceptance by owner.
� - - -- --
i
J
\ 8"
\ CE
\
24
SCALE: 1/4"=
J
i
i
i
i
CONDENSING UNIT 1
DESIGNATION
MBTUH
MBTUH
ENTERING F
ELECTRICAL DATA
REF.
UNIT
OBS OR SEER
AREA SERVED
OBS
DESIGNATION
CFM
FUSES
REF.
36.0
90
230
1
18.6
25
GOODMAN
CA *F3642 *6D *TVX
WIRE
1570
SMOKE CONTROL
J
S.R.
SIDE REGISTER
TOTAL
SENSIBLE
WB
DB
VOLTS
PHASES
HTNG KW
AMPS
FUSES
MANUFAC.
UNIT
SEER
LIO.
SUC.
COND.
CU -1
850
34.6
24.9
67
80
230
1
11
25
30
GOODMAN
DSXC 160361 A
16
318
718
1
AIR HANDLING UNIT 1
DESIGNATION
MBTUH
TEMP. ENT.
CONDENSER
ELECTRICAL DATA
MANUFAC.
REF.
UNIT
OBS OR SEER
AREA SERVED
VOLTS
PHASES
WIRE AMPS
FUSES
AHU -1
36.0
90
230
1
18.6
25
GOODMAN
CA *F3642 *6D *TVX
16
1570
DRYER VENT NOTES:
1. CLOTHES DRYER EXHAUST TO BE 30 GA. MIN.
2. CLOTHES DRYER EXHAUST-NO PR❑TRUSI ❑NS INSIDE DUCT
3. CLOTHES DRYER EXHAUST SHALL BE MIN. 4' DIA.
4. CLOTHES DRYER EXHAUST SHALL NOT BE SCREENED,
5, CLOTHES DRYER EXHAUST SHALL HAVE BACKDRAFT DAMPER
SPACE PROVIDED.
SUFFICIENT SPACE SHALL BE PROVIDED ADJACENT TO
ALL MECHANICAL COMPONENTS LOCATED IN OR FORMING
APART OF THE AIR DISTRIBUTION SYSTEM TO ASSURE
ADEQUATE ACCESS FOR
1. CONSTRUCTION AND SEALING IN ACCORDANCE WITH
THE REQUIREMENTS OF SECTION 603.1 OF THIS CODE
2. INSPECTION
3. CLEANING AND MAINTENANCE:
A MIN. OF 4" IS CONSIDERED SUFFICIENT SPACE AROUND
AIR HANDLING UNIT PER FBC MECHANICAL 603.1.3
HVAC DESIGN CHART
HVAC DESIGN REQUIRES:
YES
NO
DUCT SMOKE DETECTOR (S)
'�"
FIRE DAMPER (S)
DUCT TO MATCH NECK SIZE TIP.
0
SMOKE DAMPER (S)
QT
THERMOSTAT
FIRE RATED ENCLOSURE
AIR FLOW DIRECTION ( ARROWS DENOTE
—�
FIRE RATED ROOF /FLOOR
RETURN OR EXHAUST, SEE PLANS.
M
FIRE RATED CEILING ASSEMBLY
FIRE STOPPING
WALL MOUNTED SIDE REGISTER.
SMOKE CONTROL
J
S.R.
Q
O
X
wl
PQ
z
w
0I
IHAUST
DTL. THIS
T
NOTE: THIS IS A SEALED ATTIC.
LOCATE (1) 150 CFM 6 "X10" SUPPLY
REGISTER IN ATTIC. SPRAY FOAM
INSULATION TO BE INSTALLED ON
UNDERSIDE OF ROOF SHEATHING.
SEE SECTION A -2
LEGEND
-_
R a
Z
CEILING GRILLE SEE SIZE SCHEDULE
'�"
DUCT TO MATCH NECK SIZE TIP.
0
RAG -( RETURN AIR GRILL))
QT
THERMOSTAT
U'3
AIR FLOW DIRECTION ( ARROWS DENOTE
—�
1 WAY, 2 WAY, ETC., SEE PLANS
RETURN OR EXHAUST, SEE PLANS.
M
_a
WALL MOUNTED SIDE REGISTER.
J
S.R.
SIDE REGISTER
CD
CEILING DIFFUSER
CG
CEILING GRILLE
F.L.D
FULL LOUVERED DOOR
CU
CONDENSING UNIT
AHU
AIR HANDLER UNIT
UC
UNDERCUT DOOR FOR AIR RETURN
nu. au►�
nrR o wss�
u aow wpm GUNK No
u�ua� ra a wt ManwaG ws
ws MAY wor S OIR11011 IAIO
amour w�na�rt a ws
JOB No.:
12 "05928.SFR
REVISIONS:
A6-17-13 CU
DATE: 3/5/2012
CHECKED BY:
DRAWN BY: SRL
PLOT :100%
SHEET INDEX:
MECHANICAL PLAN
NOTES
SHEET No.:
M -1
-_
-,
Z
R
a
U'3
Uj--
LLJ
M
_a
O
O
J
M
Z
O
Z
O
D0
LV
O
U.
I
Z
>
N
t�
M LO
W
Z
LO
Q
(n
rn =E
=
M
W
O
a
cc
W
LL
j
O
_
��a0
F-
M
O
06
M
U6
N
LL
J
a0
0
Lid
�
=
oN
W
Z
Ln
O
W
LL�J
C
Z
j
O
p
Lv
CD
=
C
Q
O
O
LL_
nu. au►�
nrR o wss�
u aow wpm GUNK No
u�ua� ra a wt ManwaG ws
ws MAY wor S OIR11011 IAIO
amour w�na�rt a ws
JOB No.:
12 "05928.SFR
REVISIONS:
A6-17-13 CU
DATE: 3/5/2012
CHECKED BY:
DRAWN BY: SRL
PLOT :100%
SHEET INDEX:
MECHANICAL PLAN
NOTES
SHEET No.:
M -1
a
R
a
U'3
LLJ
M
=O
Z ^
Q
O
O
J
M
Q
O
Z
O
D0
LV
O
z
I
>
N
N
M LO
C3
LO
Q
(n
rn =E
=
M
nu. au►�
nrR o wss�
u aow wpm GUNK No
u�ua� ra a wt ManwaG ws
ws MAY wor S OIR11011 IAIO
amour w�na�rt a ws
JOB No.:
12 "05928.SFR
REVISIONS:
A6-17-13 CU
DATE: 3/5/2012
CHECKED BY:
DRAWN BY: SRL
PLOT :100%
SHEET INDEX:
MECHANICAL PLAN
NOTES
SHEET No.:
M -1