12-259-009ELECTRICAL LEGEND SINGLE RECEPTACLE 4,710 SMALL APPLIANCES--------- --- - -- 3,000 REFRIGERATOR --------------- SINGLE FL❑ ❑D - SOFFIT MOUNTED DUPLEX RECEPTACLE 500 DISPOSAL -------------------- �i 220V RECEPTACLE WASHER--------------- - - - - -- 750 DRYER---------------- - - - - -- DOUBLE FLOOD - SOFFIT MOUNTED MICROWAVE ------------------ 1,500 RANGE--------------- - - - - -- SWITCHED RECEPTACLE WATER HEATER--------- - - - - -- 16,000 4G-} GROUND FAULT INT, OUTLET 1,200 COMPACT FLUOR, - CEILING MOUNTED 48,260 314 12,000 ❑S OCCUPANCY SENSOR COMPACT FLUOR, - WALL MOUNTED WP WEATHERPR❑ ❑F GROUND 240 30 10 { LED PENDANT W/ GLASS DIFFUSER AFCI ARC FAULT INTERRUPTER 4 5 GFI GROUND FAULT INTERRUPTER O RECESSED LED HIGH HAT VP VAPOR PROOF 10 112 MS M ❑TI ❑N SENSOR 0 RECESSED LED WALL WASHER LS LIGHT SENSOR TRACK LIGHT I -124' UNDER CABINET T5 FLUOR. 20 12 EXHAUST FAN w /LIGHT QQQ COMPACT FLUOR. - WALL MTD VANITY 8 $ SINGLE POLE SWITCH EXHAUST FAN 15 14 112 *( * *) 3 WAY SWITCH O D3 DIMMER SWITCH (PR ❑VIDE MAGNETIC 70 0 L ❑W VOLTAGE TYPE R LV FIXTURES) O CEILING FAN $T MBR LIGHT & REC. ❑ 120 TIMER SWITCH O O 112 DISCONNECT SWITCH 11 O O CIRCULAR FLUORESCENT CEILING FAN w /LIGHT 120 15 00 TV TV JACK UL. 13 COMPUTER OUTLET © ELECTRIC PANEL 120 1 20 12 DATA (W/ GENERAL USE DUPLEX RECEPTICLE) SMOKE DETECTOR /CARB. MON. DET. - PHONE JACK — PREWIRE ONLY SD 120 15 SMOKE DETECTOR /GARB, MEIN, DET, 112 *( * *) ELECTRICAL NOTES 1 ) , MATERIALS , CONTRACTOR SHALL FURNISH ALL LABOR AND EQUIPMENT FOR COMPLETE ELECTRICAL INSTALLATION IN ACCORDANCE WITH THESE DRAWINGS. 2) COMPLY WITH THE N.E.C. AND STANDARD BUILDING CODE. 3) PROVIDE EMPTY CONDUITS AS REQUIRED FOR TELEPHONE SYSTEM. 4) OBTAIN ALL PERMITS FOR WORK UNDER THIS CONTRACT. 5 ) PROVIDE TEMPORARY POWER AND LIGHT OUTLETS FOR USE BY OTHER TRADES. 6) PROVIDE ALL REQUIRED CONNECTIONS FOR OTHER TRADES. 7) COORDINATE ALL OUTLET LOCATIONS WITH BUILDING ARCHITECTURAL FEATURES. 8) CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. 9) ALL CABLE SHALL BE COPPER. 10) INDOOR CONDUITS SHALL BE EMT. 1 1) ALL MOUNTING HARDWARE SHALL BE BY CONTRACTOR. 12) OUTDOOR UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC. UNDER PAVED AR E AS I T S HALL BE ENCASED IN CONCRETE. MINIMUM COVER SHALL BE 24 INCHES. CONTROL WIRING TO OTHER SMOKE DETECTORS INSIDE UNIT 120 V. SD SMOKE SWITCH LEG I I IPHASE COND. ITCH LINE DIDE S. D. SW OF SWITCH SMOKE DETECTOR DIAGRAM SCALE N.T.S. NOTE 1. SMOKE DETECTORS SHALL BE HARDWIRE (110 VOLT TYPE) TO A NON SWITCH ABLE KITCHEN OR BATHROOM LIGHTING CIRCUIT WITH BATTERY BACK UP AND SHALL NOT BE CONNECTED ONTO THE LOAD SIDE OF GROUND FAULT CIRCUIT INTERRUPTER ALL SMOKE DETECTORS WITHIN EACH UNIT SHALL BE INTERCONNECTED. 2. SMOKE DETECTORS SHALL NOT BE PLACED WITHIN 3 FT OF ANY A/C GRILL OR BATH DR. 3, PROVIDE ARC FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL 15 AND 20 AMP 125 VOLT BEDROOM BRANCH CIRCUIT OUTLETS. NEC 210 --12 NOTE: ELEC. CONTR. HAS OPTION OF [METHOD A] RUNNING ROMEX W/ PROTECTION PLATES IN CHANNEL TO BE CUT THROUGH POLYSTYRENE EXT. WALLS OR [METHOD B] IN CONDUIT RUN UNDER SLAB AND UP TO DEVICES W/ BOXES MOUNTED PRIOR TO POURING CONCRETE IN ICF WALLS. METHOD A: ROMEX WOULD BE SECURED TO PLASTIC ICFF TIES LOCATED AT 6" ON CENTER @ 518" BEHIND SURFACE OF POLYSTYRENE. DRYWALL WILL BE INSTALLED DIRECTLY ON ICF BLOCKS. ALL ELEC. BOXES MUST BE ATTACHED TO CONCRETE LOCATED 1 718" BEHIND SURFACE OF POLYSTYRENE. BOXES MUST NOT BE DEEPER THAN 2 318 ". METHOD B: ALL DEVICE BOXES CUT INTO ICF BLOCKS PRIOR TO CONCRETE POUR MUST BE SECURELY BRACED TO RESIST PRESSURE OF WET CONCRETE, ELECTRICAL_ LOAD CAL_CUL,ATZCN NEW PANEL- "A" SQ FT, -------------- - - - - -- 1,570 GENERAL LIGHTING (3W. /S,FJ - -- 4,710 SMALL APPLIANCES--------- --- - -- 3,000 REFRIGERATOR --------------- 1,000 DISHWASHER------------- --- - -- 500 DISPOSAL -------------------- 800 WASHER--------------- - - - - -- 750 DRYER---------------- - - - - -- 6,800 MICROWAVE ------------------ 1,500 RANGE--------------- - - - - -- 12,000 WATER HEATER--------- - - - - -- 16,000 SPRINKLER PUMP -- 1,200 50 48,260 CONNECTED L❑ADD (LESS A /C) -- 48,260 FIRST 10KW @ 100%----- - - - - -- 10,000 BAL. @ 40%----------- - - - - -- 15,304 A/C OR HTG, @ 100%---- - - - - -- 8,040 DEMAND LOAD: ------------- 33,344 AMPS @ 240/120V 1PH --------- 139 AMP PANEL / MCB ---------- - - - - -- -200 AMP WE, SPEC NOTES BKR AMP ALL SMOKE DETECTORS SHOULD BE NOT LESS S -0" FROM A/C GRILLS & RELOCATED IF VA NECESARY, RANGE WET LOCATION NOTES: 1. ALL ELECT. EQUIP. EXPOSED TO WEATHER SHALL COMPLY TO NEC 373 -2 (A) 2. SWITCHES OR CIRCUIT BREAKERS IN WET LOCATION OR OUTSIDE OF A BUILDING SHALL BE ENCLOSED IN A WEATHERPROOF ENCLOSURE OR CABINET. PER NEC 380 -4 3. NO SWITCHES SHALL BE INSTALLED WITHIN WET LOCATION GENERAL NOTES Location.- See plan NEW PANEL "A" Main BUS 200 AMP 32 SPACE 40 CIRCUfT CE Voltage= 1201240 v, 1f ,3W Main Breaker METER COMBO (MCB) Mountings RECESSED Ate 10,E GFI= Ground Fault Interrupter NCL= Non — concurrent load REC= Receptacle Ckt Lts= Lighting Ckt ST= Breaker with shunt trip T =Via timer IS= Isolated ground Ckt C= Via contactor SWD= On —Off Switching Duty rated breoker,as per NEC 240 -83(d) LV= Via low voltage transformer HACK= Breaker suitable for the protection of heating, A/C and refrigeration equipment Ckt No. USE SPEC VOLT BKR AMP WIRE COND SIZE VA PHASE Ckt No. WE, SPEC VOLT BKR AMP WIRE COND SIZE VA A C RANGE 240 50 6 314 12,000 C. U. Z 240 30 10 314 5,000 3 4 5 DRYER W 240 30 10 112 6,800 d' ¢ 6 REFRIGERATOR W 120 20 12 112 800 7 8 BATH 1, WIC LIGHTS & REC 120 15 14 112 *( * *) 9 WH 1 240 70 4 314 11,800 10 MBR LIGHT & REC. ❑ 120 15 14 112 *( * *) 11 12 BR 2, HALL, UTIL, LT. &REC. 1 120 15 14 112 *( * *) UL. 13 WASHER 120 1 20 12 112 750 — 14 BR 3, BATH 2 LT. & REC. 120 15 14 112 *( * *) 15 BATH 1 GFI 120 20 12 112 * 16 BATH 2 CFI A O 120 20 12 112 17 GARBAGE DISPOSAL 120 20 12 112 800 18 KITCHEN, FOYER LT. & REC 0 �C 120 15 14 112 *( * *) 19 DISHWASHER 120 20 12 112 500 - 20 DINING, GR. LIGHT & REC 120 20 12 112 *( * *) 21 SMALL APPLIANCE 1201 20 12 112 1500 22 SPARE 23 SMALL APPLIANCE 120 20 12 112 15oo 24 EXTERIOR LIGHTS & REC 120 20 12 112 25 MICROWAVE 120 20 12 112 loo0 26 SPARE 27 A.H.U. 240 40 8 314 8.040 28 VIM 2 220 25 10 112 4,200 29 30 31 SPARE 32 SPARE ( *) AS PER SQ -FT OF CONDITION SPACE ** ARC FAULT CIRCUIT INTERRUPTER PROTECTION 1, PROVIDE EXPANSION JOINTS FITTINGS TO CONDUITS CROSSING STRUCTURAL EXPANSION JOINTS. 2. PROVIDE PULL WIRES IN TELEPHONE AND ALL EMPTY CONDUIT SYSTEMS. 3 , ALL CONDUCTORS SHALL BE COPPER. 4. ALL CONTROL WIRES AND CONNECTIONS REQUIRED FOR AIR CONDITIONING AND VENTILATING EQUIPMENT OPERATION SHALL BE PROVIDED. REFER TO MECHANICAL DRAWING. 5. LOCATION OF OUTLETS IN ELECTRICIAN DRAWINGS IS DIAGRAMMATIC. CHECK ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF OUTLETS. ADJUST OUTLET LOCATIONS TO AVOID INTERFERENCE WITH OTHER TRADES. 6 LOCATION OF SWITCHES VARIES WITH THE DOOR SWING: FOLLOW ARCHITECTURAL DRAWINGS IN EACH CASE. 7. CLAIMS FOR EXTRA WORK REQ'D TO MEETCODE REQUIREMENTS WILL NOT BE CONSIDERED. 8. AMONG ELECTRICAL CONTRACTOR'S RESPONSIBILITIES THERE SHALL BE: 8.1 TO VERIFY ACTUAL FIELD CONDITIONS PRIOR BIDDING. ONCE THE AMOUNT OF WORK INVOLVED HAS BEEN DETERMINED, THE CONTRACTOR SHALL INCLUDE IN HIS BID ALL NECESSARY PARTS AND LABOR REQUIRED TO COMPLETE A SAFE AND CORRECT ELECTRICAL INSTALLATION. 8.2 — TO PROVIDE ADEQUATE WIRING, BREAKER OR SWITCH PROTECTION TO CONFORM WITH FURNISHED EQUIPMENT WITHOUT EXTRA COST TO THE OWNER. 8.3 — TO CONTACT F.P.L. COMPANY'S REPRESENTATIVE TO DETERMINE FINAL UNDERGROUND PRIMARY CONDUITS ROUTING AND TO INSTALL THEM AS PER F.P.L. COMPANY'S STANDARDS. 8.4 TO CONTACT TELEPHONE COMPANY'S REPRESENTATIVE TO DETERMINE FINAL ROUTING UNDERGROUND CONDUITS FOR TELEPHONE SUPPLY AND TO INSTALL THEM AS PER THE COMPANY'S STANDARDS. 8.5 TO VERIFY EXISTING UTILITIES FACILITIES PRIOR TRENCHING. 8.6 TO COORDINATE, PRIOR TO CONSTRUCTION, WITH MECHANICAL AND PLUMBING SUBCONTRACTORS REGARDING SPACE REQUIRED FOR FULL INSTALLATION. AND POSSIBLE CONFLICTS. 9. ALL 15 AND 20 AMP OUTLETS IN FAMILY ROOM, DINING ROOM, LIVING ROOM, BEDROOMS, CLOSETS, HALLWAY TO BE PROTECTED BY A LISTED ARC FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE. 10. ALL OUTLETS TO BE TAMPLER PROOF TYPE WEATHER HEAD TO FPL 3 #210 THWN (Cu) IN 2" COND. RUNNING FROM F.P.L. SERVICE POINT. ELEC. METER 200A MCB 1 # 4 THWN (Cu) IN 314" COND. GRADE LEVEL PITCH POCKETICAP 314" EMT TO ROOF FOR FUTURE SOLAR TERMINATE +4FT AFF 314" EMT TO UTIL. RM. 'FOR FUTURE SOLAR 3 #210 THWN (Cu) HOSE BIBB 1#6 THWN (Cu) G IN 2" COND, 3 4 "0 CWP NEW 10' -0" DEEP GROUNDjA NEW #4 IN 1/2" CONDUIT ROD - 112" DIAMETER _ TO (2) 5/8" X 10 FT GROUND RODS ® MIN. 6 FT APART ELECTRICAL RISER DIAGRAM N. T. S. - - A24 9_ VP MS - A24 -- A24 -�G VP "�"s VP ............................... ................. .__.......... ..................... ...................................................;............... .... ................. ............................................................... .....;.............. ,........_ _....................:...:..... ........... ... ............... .. .... ..............._.. ............................................ Al2 / I� \A8 .......A1`6 � VP r��I�rooM 2 A8 / 1 A8 ZZ 1 MA57�� ?T T iAl O I Al2 Al2 t A� A10 6 SD A16 �0A 10 1, 6i VPt..... ;Af2O r�l AA 21 0 , I LS El `p\ \ / i tR . \1 / I - ZO— I A20 A20 Al2 ;.I \ ® A128 PNL A '69t- Al2 - A9 11 O / E — -1 ...` A10 I I Al2 U rIKfrY A24 A27 1 A13 A5,7 G , _ �______/ + 2 4 ........... \20 ___________________ A14 G VP A ,. r jA 0 - 3' /�- A 16 ., A14 IHJG ; VE A18 KI I Al 8 11iA2l ka, A14 VP I 1 � ❑S 1 Ln () T V A20 O A20 A201 I— A T6. I I \ QA14 A23, \ ..A18 A18 A14 A14 G �1.. -------- ;;«; ---- " O O 1-DYCI'. Al 8 f3�r >IZOOM 5 A18 Al ............... ................... O \ � A 2 4 A24 . -VP , ............. ........................ LS A24)(P A20 / TO FPL U.P. SCALE: 1/4"=-V-0" I MS I A24 .t , . P AFMWN H]!M CONi11 M CR W& AND udP UAM W= OF 'RE ARCHr=. nE SAM MAY NOT N DIIPLlG17FA 1lRD OR ONCLOM M11T 5 111tl77E11 O6CC GF W A JOB No.: 12.06487 . S FR REVISIONS: DATE: 3/5/2012 CHECKED BY: DRAWN BY: SRL PLOT: 100% SHEET INDEX: ELECTRICAL PLAN NOTES SHEET No.: E -1 a z a o U Q — W LLj a zz ^^ 0 J .1.. Z © ci 00 • I.= - W J LL. I Z W 0 W F- d' ¢ z ,�, o W W rn 55 c M 0 Z = a w LL = > QMaoo J LU O ❑ = r z O I— cr) 0 1 o M LL. O UL. r LL Uj Q cn c4 C�� < tG A O Z F- U LLJ to � W O O Of 0 �C O C) U_ , . P AFMWN H]!M CONi11 M CR W& AND udP UAM W= OF 'RE ARCHr=. nE SAM MAY NOT N DIIPLlG17FA 1lRD OR ONCLOM M11T 5 111tl77E11 O6CC GF W A JOB No.: 12.06487 . S FR REVISIONS: DATE: 3/5/2012 CHECKED BY: DRAWN BY: SRL PLOT: 100% SHEET INDEX: ELECTRICAL PLAN NOTES SHEET No.: E -1 a a Q LO LLj to J Z © ci 00 • I.= - W J Z I W U F- d' ¢ w ,�, o rn , . P AFMWN H]!M CONi11 M CR W& AND udP UAM W= OF 'RE ARCHr=. nE SAM MAY NOT N DIIPLlG17FA 1lRD OR ONCLOM M11T 5 111tl77E11 O6CC GF W A JOB No.: 12.06487 . S FR REVISIONS: DATE: 3/5/2012 CHECKED BY: DRAWN BY: SRL PLOT: 100% SHEET INDEX: ELECTRICAL PLAN NOTES SHEET No.: E -1