Loading...
13-792R-001al A -30 A -30 O - I i A -30 A -12,14 CU -1 A -15 A -15 O CU -2 WP A -15 p 5 A -20 0 I LTJ A -32 A -15 A -30 MEDIA ROOM C A -15 S4 � B -11 p A-15 A -15 COVERED A -30 TERRACE A -30 A -30 K. J STORAGE AC�o O A=20 FOOL EOUI '. - = A-25 PANEL A -25 r A -20 O O A -20 LIVING OOM I I O O A -20 — A -20 A -25 A -25 A -25 A— A -30 A -30 A -32 A -30 A -30 A -30 A -33 -� WP A -26 A -27 O A -27 — A -22 A -26 A -26 — — -- A -26 O O O f TO LIGHT 3 3 I FIXTURES ABOVE A -6 A -6 A -24 I I I rA�- O O O O A -24 A -24 A -24 A -24 ® I A -28 A -28 A -24 ''r' p O A - I DINING ROOM I s,11 ER I - f � A -28 I L A -6 IO OI �A -28 A -28� 3 3 3 — A -6 1 A -6 ern " A 25 W — TO LIGHT FIXTURES ABOVE f ELECTRICAL SYMBOL LEGEND —17 —36T I w JUNCTION BOX ENTFrr o /LJB W /SPECIAL SUPPORT FAN & LIGHT — — f FAM I Y A -39 MINI HIGH HATS LIGHTING A -26 0 VAPOR PROOF I I ® CEILING MOUNTED Fr c 39 ROOM j+ WALL MOUNTED FIXTURE A_28 ®7 O A -2 Q MOTOR FOR CHANDELIER 5 .a PICTURE WALL MOUNTED FIXTURE SD FLUORESCENT FIXTURE I A -33 = QUADRUPLEX RECEPTACLE 59 KITCH N GFI RECEPTACLE f GFI RECEPTACLE 8" ABOVE COUNTER -2 BREAKFAST 8— SINGLE RECEPTACLE A 39 STAIR O I I RECEPTACLE A -26 �= SWITCHABLE DUPLEX RECEPTACLE - WALL _j I O A -26 ♦ A -26 p A -28 OPEN TO I L� EXHAUST FAN ra cd b Wp WEATHER PROOF I ABOVE SWITCH A— I $3 3WAY SWITCH I A $o LOW VOLTAGE SYSTEM SWITCH (DIMMER) _ A-28 � II f I TELEVISION CABLE OUTLET -- a -28J O P�MITR`I' GARAGE DOOR OPENER CONTROLLER I I A -26 -A=7 —29 I TO HAI IDELLIER p O O A- 6 — ABO 26 -- -- - — — — — — f O A -27 A -27 I A -28 TO LIGHT 3 3 I FIXTURES ABOVE A -6 A -6 A -24 I I I rA�- O O O O A -24 A -24 A -24 A -24 ® I A -28 A -28 A -24 ''r' p O A - I DINING ROOM I s,11 ER I - f � A -28 I L A -6 IO OI �A -28 A -28� 3 3 3 — A -6 1 A -6 ern 1 A -35 A- A -39 _ " A 25 W — TO LIGHT FIXTURES ABOVE f ELECTRICAL SYMBOL LEGEND —17 —36T I mil? w JUNCTION BOX ENTFrr o /LJB W /SPECIAL SUPPORT FAN & LIGHT — — I X- HIGH HATS LIGHTING A -39 MINI HIGH HATS LIGHTING AID'S 0 VAPOR PROOF A -28 NC ® CEILING MOUNTED Fr c 39 — A -28 j+ WALL MOUNTED FIXTURE A_28 ®7 O A -2 Q MOTOR FOR CHANDELIER O .a PICTURE WALL MOUNTED FIXTURE SD FLUORESCENT FIXTURE A -13 = QUADRUPLEX RECEPTACLE 59 KITCH N GFI RECEPTACLE I GFI RECEPTACLE 8" ABOVE COUNTER -2 BREAKFAST 8— SINGLE RECEPTACLE A -13 2 POLE OUTLET O RECEPTACLE 28 �= SWITCHABLE DUPLEX RECEPTACLE Nk GARBAGE DISPOSAL _j c� SPOT LIGHT A -28 A -28 Illli-w-3 ELECTRIC PANEL OA01 L� EXHAUST FAN ra cd b Wp WEATHER PROOF 0 co rn b b v A, SWITCH A— A-28 $3 3WAY SWITCH I A $o LOW VOLTAGE SYSTEM SWITCH (DIMMER) O TELEPHONE TELEVISION CABLE OUTLET -- a -28J SD SMOKE DETECTOR P�MITR`I' GARAGE DOOR OPENER CONTROLLER A- INTERCOM -A=7 —29 LIGHTING FIXTURES FOR KITCHEN CABINETS _ 1 (12 VOLTS) (UNDER COUNTER) COMBINATION SMOKE CARBON/ MONOXIDE DETECTOR FD _Bj DOOR BELL cH CHANDELLIER 1 A -35 A- A -39 _ " f}—! w m 6L, to —17 —36T A -39 w P � � 0 o E--4 A I X- A -39 �J 4 AID'S A- TEL cl.oSET NC A c 39 — A -28 _ A_28 ®7 O A -2 B -11 O O SD 0 A -13 A— 59 KITCH N I -2 BREAKFAST A -13 A -13 I O 28 Nk _j O A -28 A -28 I OA01 ra cd b � 0 co rn b b v A, A— A-28 E-1 I A 39 O O - - - - -- a -28J P�MITR`I' A -39 A- -A=7 —29 Y _ G A -38 A -38 a MAIDS BEDROOM I A -13 N C) A-35 PANEL PANEL WP A" A -34 A -34 A -34 2 CAR G,4R,4GE L A -3 GROUND FLOOR ELECTRICAL PLAN SCALE: 1/4•• = I' -m" B -19 A -34 B- 30,32 8 -34,36 B -22,24 �K \Xg- N ' YM: LOAD CENTER I� t� MAIN _13U8: 200 A ^ SERVICE: HOUSE FA E L I I 11 %(E(,�' �►L;: 29fi VOLTAGE: 1201240 10, 3W MAN-. -MLO- MOLINTM/LOCATION: SURFACE AiCS: 10 000 w ,.. Ut i REMARIGS � � MAF" �- > 3 1 2 SMALL APPLIANCES 12 R 1500 1 20 60 2 10750 R 6 AHU -1 3 4 SMALL APPLIANCES 12 R 1500 1 20 20 1 1,50o R 12 BATHROOM RECEP. 5 6 SMALL APPLIANCES 12 R 1500 1 20 20 1 1500 R 12 FREEZER /REFRIG. 7 8 EWH 8 R 6000 2 40 9 10 30 2 4500 R 10 DRYER CU #1 6 R 9200 2 60 20 1 1200 R 12 GEN. LIGHTS /RECEPT. 13 14 20 1 1200 R 12 GEN. LIGHTS /RECEPT. 15 16 RANGE CONTROLS 14 R 300 1 15 20 1 600 R 12 DISPOSAL 17 18 SPACE — — — — — 20 1 1500 R 12 WASHER MACHINE 19 20 GENERAL LIGHTING 12 R * 1 20 20 1 800 R 12 ICE MACHINE 21 22 GENERAL LIGHTING 12 R * 1 20 20 1 900 R 12 KITCHEN HOOD 23 24 GENERAL LIGHTING 12 R * 1 20 R 12 GEN. RECEPT. 25 26 GENERAL LIGHTING 12 R * 1 20 20 1 1200 20 1 1200 R 12 GEN. RECEPT. 27 28 GENERAL LIGHTING 12 R * 1 20 29 30 GENERAL LIGHTING 12 R * 1 20 40 2 8300 R 8 MICROWAVE /OVEN 31 32 GENERAL LIGHTING 12 R * 1 20 20 1 1000 R 12 GEN. RECEPT. 33 34 GENERAL LIGHTING 12 R * 1 20 20 1 1000 R 12 GEN. RECEPT 35 36 DISHWASHER 12 R 800 1 20 20 1 500 R 12 REFRIGERATOR (WINE) 37 38 GARAGE OPENER 12 R 700 1 20 20 1 800 R 12 CABINETS LIGHTS 39 �42 GEN. LIGHTS 12 R 700 1 20 20 1 1000 R 12 GEN. RECEPT. 41 SPACE — — — — — FEEDER: SEE RISER CONNECTED LOAD: SEE LOAD CALCULATION NC NON CONCURRENT LOAD FED FROri: SEE RISER * AS PER SQ —FT OF CONDITION SPACE. LOCATION OF PANEL MAY CHANGES DEPENDING ON UTILITY ALL NEW 120 —VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT. ALL NEW 125 VOLTS ONE PHASE 15 AND 20 AMPS - RECEPTACLES SHALL BE LISTED TAMPER — RESISTANT RECEPTACLES, LOAD CENTER MAIN EM: 100 A SERVICE:: POOL & GAZEBO PANEL I1 � I1 NEUTRAL MAIN-. M : 100 A VOLTACIE: 1201240 10, 3W MAIN: MOI,INTINC /LOCATION; SURFACE AICB: 10 0 000 REMARKS Q �REMARIGS p % to to di to a } a 1 41 2 POOL LIGHTING 12 112 1800 1 20 30 2 1800 112 10 BLOWER 3 4 GEN. REC. 12 112 1500 1 20 5 6 SPACE — — — — — 30 2 1800 112 10 POOL PUMP 7 g SPACE — — — — — 9 10 SPACE — — — — — 60 2 8000 314 6 POOL HEATER 11 SPACE — — — — - - SPACE 13 14 SPACE — — — — - - SPACE 15 16 SPACE - - - - - CONNECTED LOAD: AT 1009 - -- 18,3001240 = 76 AMPS FEEDER: SEE RISER FED F 1?.0M: SEE RISER ELECT. METER MAIN COMB. W /ONE 200 AMPS MCB FOR PANEL "A" fW /ONE 200 AMPS MCB FOR PANEL "B" W /ONE 100 AMPS MCB FOR PANEL "C" a A -39 1~LECTRICAL MOTES 1) CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT FOR COMPLETE ELECTRICAL INSTALLATION IN ACCORDANCE WITH THESE DRAWINGS. 2) COMPLY WITH THE N.E.C. AND STANDARD BUILDING CODE. 3) PROVIDE EMPTY CONDUITS AS REQUIRED FOR TELEPHONE SYSTEM. 4) OBTAIN ALL PERMITS FOR WORK UNDER THIS CONTRACT, 5) PROVIDE TEMPORARY POWER AND LIGHT OUTLETS FOR USE BY OTHER TRADES. 6) PROVIDE ALL REQUIRED CONNECTIONS FOR OTHER TRADES. 7) COORDINATE ALL OUTLET LOCATIONS WITH BUILDING ARCHITECTURAL FEATURES. 8) CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. 9) ALL CABLE SHALL BE COPPER. 10) INDOOR WIRING SHALL BE ROMEX TYPE 11) ALL MOUNTING HARDWARE SHALL BE BY CONTRACTOR. 12) OUTDOOR UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC. UNDER PAVED AREAS IT SHALL BE ENCASED IN CONCRETE MINIMUM COVER SHALL BE 24 INCHES. P.E. No 53288 .lose Antonio Mendez. Professional Engineer ®Q m m 0 .�c 1385 Core) Way Suite #203 Miami, FL 33145 �j PH:(305)854 -9824 FAX(305)858 -1797 �m ®am��ma CA 00008833 24 comma. / 1 jose0118 @8ol.com \ / f}—! w m 6L, to A -2p4 m LO E- WoU o `f' AfC A P � � 0 E--4 I X- O �J 4 AID'S B- TEL cl.oSET NC BATH A -41 o ®7 O A -2 B -11 A -13 I"I LL SD 0 A -13 D A -13 A -13 A -13 A -38 A -38 a MAIDS BEDROOM I A -13 N C) A-35 PANEL PANEL WP A" A -34 A -34 A -34 2 CAR G,4R,4GE L A -3 GROUND FLOOR ELECTRICAL PLAN SCALE: 1/4•• = I' -m" B -19 A -34 B- 30,32 8 -34,36 B -22,24 �K \Xg- N ' YM: LOAD CENTER I� t� MAIN _13U8: 200 A ^ SERVICE: HOUSE FA E L I I 11 %(E(,�' �►L;: 29fi VOLTAGE: 1201240 10, 3W MAN-. -MLO- MOLINTM/LOCATION: SURFACE AiCS: 10 000 w ,.. Ut i REMARIGS � � MAF" �- > 3 1 2 SMALL APPLIANCES 12 R 1500 1 20 60 2 10750 R 6 AHU -1 3 4 SMALL APPLIANCES 12 R 1500 1 20 20 1 1,50o R 12 BATHROOM RECEP. 5 6 SMALL APPLIANCES 12 R 1500 1 20 20 1 1500 R 12 FREEZER /REFRIG. 7 8 EWH 8 R 6000 2 40 9 10 30 2 4500 R 10 DRYER CU #1 6 R 9200 2 60 20 1 1200 R 12 GEN. LIGHTS /RECEPT. 13 14 20 1 1200 R 12 GEN. LIGHTS /RECEPT. 15 16 RANGE CONTROLS 14 R 300 1 15 20 1 600 R 12 DISPOSAL 17 18 SPACE — — — — — 20 1 1500 R 12 WASHER MACHINE 19 20 GENERAL LIGHTING 12 R * 1 20 20 1 800 R 12 ICE MACHINE 21 22 GENERAL LIGHTING 12 R * 1 20 20 1 900 R 12 KITCHEN HOOD 23 24 GENERAL LIGHTING 12 R * 1 20 R 12 GEN. RECEPT. 25 26 GENERAL LIGHTING 12 R * 1 20 20 1 1200 20 1 1200 R 12 GEN. RECEPT. 27 28 GENERAL LIGHTING 12 R * 1 20 29 30 GENERAL LIGHTING 12 R * 1 20 40 2 8300 R 8 MICROWAVE /OVEN 31 32 GENERAL LIGHTING 12 R * 1 20 20 1 1000 R 12 GEN. RECEPT. 33 34 GENERAL LIGHTING 12 R * 1 20 20 1 1000 R 12 GEN. RECEPT 35 36 DISHWASHER 12 R 800 1 20 20 1 500 R 12 REFRIGERATOR (WINE) 37 38 GARAGE OPENER 12 R 700 1 20 20 1 800 R 12 CABINETS LIGHTS 39 �42 GEN. LIGHTS 12 R 700 1 20 20 1 1000 R 12 GEN. RECEPT. 41 SPACE — — — — — FEEDER: SEE RISER CONNECTED LOAD: SEE LOAD CALCULATION NC NON CONCURRENT LOAD FED FROri: SEE RISER * AS PER SQ —FT OF CONDITION SPACE. LOCATION OF PANEL MAY CHANGES DEPENDING ON UTILITY ALL NEW 120 —VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT. ALL NEW 125 VOLTS ONE PHASE 15 AND 20 AMPS - RECEPTACLES SHALL BE LISTED TAMPER — RESISTANT RECEPTACLES, LOAD CENTER MAIN EM: 100 A SERVICE:: POOL & GAZEBO PANEL I1 � I1 NEUTRAL MAIN-. M : 100 A VOLTACIE: 1201240 10, 3W MAIN: MOI,INTINC /LOCATION; SURFACE AICB: 10 0 000 REMARKS Q �REMARIGS p % to to di to a } a 1 41 2 POOL LIGHTING 12 112 1800 1 20 30 2 1800 112 10 BLOWER 3 4 GEN. REC. 12 112 1500 1 20 5 6 SPACE — — — — — 30 2 1800 112 10 POOL PUMP 7 g SPACE — — — — — 9 10 SPACE — — — — — 60 2 8000 314 6 POOL HEATER 11 SPACE — — — — - - SPACE 13 14 SPACE — — — — - - SPACE 15 16 SPACE - - - - - CONNECTED LOAD: AT 1009 - -- 18,3001240 = 76 AMPS FEEDER: SEE RISER FED F 1?.0M: SEE RISER ELECT. METER MAIN COMB. W /ONE 200 AMPS MCB FOR PANEL "A" fW /ONE 200 AMPS MCB FOR PANEL "B" W /ONE 100 AMPS MCB FOR PANEL "C" a A -39 1~LECTRICAL MOTES 1) CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT FOR COMPLETE ELECTRICAL INSTALLATION IN ACCORDANCE WITH THESE DRAWINGS. 2) COMPLY WITH THE N.E.C. AND STANDARD BUILDING CODE. 3) PROVIDE EMPTY CONDUITS AS REQUIRED FOR TELEPHONE SYSTEM. 4) OBTAIN ALL PERMITS FOR WORK UNDER THIS CONTRACT, 5) PROVIDE TEMPORARY POWER AND LIGHT OUTLETS FOR USE BY OTHER TRADES. 6) PROVIDE ALL REQUIRED CONNECTIONS FOR OTHER TRADES. 7) COORDINATE ALL OUTLET LOCATIONS WITH BUILDING ARCHITECTURAL FEATURES. 8) CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. 9) ALL CABLE SHALL BE COPPER. 10) INDOOR WIRING SHALL BE ROMEX TYPE 11) ALL MOUNTING HARDWARE SHALL BE BY CONTRACTOR. 12) OUTDOOR UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC. UNDER PAVED AREAS IT SHALL BE ENCASED IN CONCRETE MINIMUM COVER SHALL BE 24 INCHES. P.E. No 53288 .lose Antonio Mendez. Professional Engineer ®Q m m 0 .�c 1385 Core) Way Suite #203 Miami, FL 33145 �j PH:(305)854 -9824 FAX(305)858 -1797 �m ®am��ma CA 00008833 24 comma. / 1 jose0118 @8ol.com H V1 W x U A O w E� W E-+ .. E- Q w W � U Uj Z W o El cn M r4 Ids W o Z � f}—! w m 6L, to m LO E- WoU o � I I I w o P � � 0 E--4 �O W z�:)M C7 °a HaC NC O _ H o q 0 m co H V1 W x U A O w E� W E-+ .. E- Q w W � U Uj Z W o El cn M r4 Ids W � I I I 01 1 1 z� D 0 Nk _j O ra cd b � 0 co rn b b v A, sheet no. E-1 -of -