RETURN LINE FROM CIRCULATING LOOP
FOR STORED TEMPERATURE WATER
(IF USEED)
CHECK
VALVE iii
FLO
REGULATING
PLUG COCK
TEMPERATURE AND
PRES. RELIEF VALVE
314" THICK (MIN.)
PIPE TO OUTSIDE OF
BUILDING k DISCHARGE
6" ABOVE GRADE COLD WATER
INLET LINE ---.
UNION
HEAT TRAP PER
ENERGY CODE
r/ II
v
HOT WATER J __�EO
SUPPLY LINE
i
EMBLEM AND
RATING PLATE
ELECTRICAL L_�
ACCESS PANELS
`y-- LINE TEMP.
CONTROL
ALL BRONZE
CIRCULATING
PUMP
�-- SHUT -OFF
VALVE
UNION
— ELECTRICAL
JUNCTION BOX
ELECT.
CONN.
IN .VALVE
WATER ' HEATER %' RN '. of x HOSE
PAN k (OMIT ,ON �` CONNECTION
GROUND -,aR,) ' xl
PAN DRAIN
PARALLEL TO
P&T •RELIEF
E ,
H.W.H. CIRCULATING PUMP DETAIL N.T.S.
EWH CAPACITY 80 GALLONS ENERGY EFFICENCY 0.85 MIN.
WATER PIPING SIZE -2
TQ
�—
U
. • •
GENERAL PLUM13ING NOTES
•••
Y • •
u • • • u •
112 "0
CW
1. ALL WORK SHALL CONFORM WITH FLORIDA BUILDING CODE 2010
PAID ALL THE INSPECTION FEES AS MAY REQUIRED BY LAW Cik% " "` •`•
EDITION (F.B.C.2010), FEDERAL ORDINANCES GOVERNING THE
ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM AN-,'1
INSTALLATION OF THE PLUMBING SYSTEM. IF WORK AS LAID
DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF LAWS, 9 ••
OUT, INDICATED OR SPECIFIED 1S CONTRARY TO OR CONFLICTS
RULES OR ORDINANCES.
WITH LOCAL ORDINANCES, BUILDING CODES AND REGULATIONS,
TB
THE CONTRACTOR SHALL REPORT IN WRITING TO THE
PROVIDE MEANS "FURNISH AND INSTALL ".
ARCHITECT /ENGINEER. BEFORE SUBMITTING A BID. THE
ARCHITECT /ENGINEER. WILL THEN ISSUE INSTRUCTIONS AS
-
d. DO A COMPLETE JOB, EVERYTHING CONNECTED, READY FOR USE.
HOW TO PROCEED.
U
z
9. SHOP DRAWINGS: CONTRACTOR SHALL FURNISH THE ENGINEER
2 THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT
WITH SHOP DRAWINGS OF EQUIPMENT PRIOR TO PURCHASE
NECESSARILY SHOWING IN DETAIL OR' TO ` SCALE ALL OF' THE
FOR APPROVAL BY PROPER AUTHORITIES. `
MINOR ITEMS. UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE
10. AT COMPLETION OF JOB THE PLUMBING CONTRACTOR SHALL.
STRUCTURAL, ARCHITECTURAL AND SITE CONDITIONS SHALL
GIVE THE OWNER AN AS -BUILT SET OF REPRODUCIBLE SEPIAS
GOVERN THE EXACT LOCATIONS. CONTRACTOR SHALL FOLLOW
SHOWING THE EXACT LOCATION OF ALL INSTALLATIONS.
DRAWINGS IN LAYING OUT WORK, CHECK DRAWINGS OF ALL
1 -1/4 70 CW, 314 "0 HW
TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED
AND MAINTAIN MAXIMUM HEAD ROOM, AND SPACE CONDITIONS
11. PLUMBING CONTRACTOR SHALL PRESSURE TEST ALL PIPING AS
AT ALL POINTS, WHERE HEAD ROOM, OR SPACE CONDITIONS
REQUIRED BY CODE TEST SHALL- BE WITNESSED AND APPROVED
APPEAR INADEQUATE, ARCHITECT/ ENGINEER SHALL BE
TO THE OWNER.
NOTIFIED BEFORE PROCEEDING WITH INSTALLATION. THIS
CONTRACTOR SHALL, WITHOUT EXTRA CHARGE, MAKE FIELD
12. THE PLUMBING CONTRACTOR SHALL WARRANT ALL
MODIFICATION IN LAYOUT AS NEEDED TO PREVENT CONFLICT
WORKMANSHIP AND MATERIALS FOR ONE YEAR FROM THE DATE
WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION
OF FINAL WORK ACCEPTANCE BY OWNER. ANY BREAKDOWN
OF THE WORK .
OCCURRING IN FIRST YEAR SHALL BE REPAIRED AT NO EXPENSE
3. EXAMINE ALL DRAWINGS CAREFULLY PRIOR TO SUBMITTING A BID.
13. PROVIDE BATHROOM FIXTURES AS SPECIFIED OR AS SELECTED BY
CONTRACTOR WILL BE REQUIRED TO FURNISH, INSTALL AND /OR
OWNER AND TO COMPLY W/F.B.C.2010
CONNECT WITH APPROPRIATE SERVICES ALL PLUMBING ITEMS
14. PROVIDE SHUTOFF VALVE FOR EACH FIXTURE.
SHOWN ON ANY OF THE ARCHITECTURAL, AIR CONDITIONING,
ELECTRICAL AND SPRINKLER DRAWINGS WITHOUT ADDITIONAL
EXPENSE TO THE OWNER. !F DISCREPANCIES CONFLICTS
15. WHEREVER NOT SIMILAR METALS ARE TO BE JOINED, A DIELECTRIC
INTERFERENCE OR OMISSIONS OCCUR BETWEEN DRAWINGS,
FITTING SHALL BE PROVIDED TO CONNECT BOTH TYPES OF PIPES.
NOTIFY IN WRITING THE ARCHITECT / ENGINEER IN AMPLE TIME
TO PERMIT REVISIONS BEFORE THE BIDS ARE SUBMITTED.
16. PLUMBING CONTRACTOR SHALL PROVIDE AIR CONDITIONING
CONDENSATE DRAIN AND TRAP. SEE AIR CONDITIONING PLANS
4. INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST
FOR LOCATION OF UNITS AND DRAINS.
CLASS WORKMANLIKE MANNER. THE OWNER RESERVES THE
.17.. ALL SANITARY FITTINGS SHALL BE DIRECTIONAL TYPE -
RIGHT TO DIRECT REMOVAL AND REPLACEMENT OF ITEMS WHICH,
IN HIS OPINION, DO NOT PRESENT A NEAT AND WORKMANLIKE
18. MATERIALS
APPEARANCE. REMOVAL AND REPLACEMENT IS TO BE DONE
A. COLD WATER PIPING DOWNSTREAM OF WATER METER SHALL BE
IMMEDIATELY WHEN DIRECTED BY THE OWNER IN WRITING, AT
TYPE C' COPPER BELOW GROUND AND TYPE "M" COPPER ABOVE GROUND.
THE SOLE EXPENSE OF CONTRACTOR.
B. COLD WATER PIPES INSIDE OF SLAB SHALL BE TYPE "K" SOFT COPPER
5. START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS
INSTALL INSIDE POLYETHYLENE CONDUIT. NO JOINTS PERMITTED INSIDE SLAB.
ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS AS TO
C. SANITARY WASTE AND VENT 470 AND SMALLER SHALL BE P.V.C.,SCHEDULE 40
SUITABILITY OF THE WORK OF OTHER. TRADES OR OTHER
S. STORM LINES INSIDE BUILDING SHALL BE P.V.C. SCHEDULE 40
CONTRACTORS TO RECEIVE HIS WORK. THIS CONTRACTOR "
E IN COASTAL AREAS ALL SANITARY AND STORM PIPING OUTSIDE OF BUILDING
SHALL REMOVE AND REPLACE, AT HIS EXPENSE, ALL PLUMBING
SHALL BE SCHEDULE 40, PVC.
WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF
F. CONDENSATE DRAIN PIPE SHALL BE SCHEDULE 40, PVC PIPE AND FITTINGS.
INTERFERENCE WITH OTHER TRADES.
G. WATER HEATER RELIEF AND DRAIN 'LINE SHALL BE TYPE "L" COPPER,
MIN. 314" DIA.
6. THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE,
FEES, PERMITS , ASSOCIATION DUES, ROYALTIES AND TAXES OF
WHATEVER NATURE SHALL APPLY TO THIS WORK. HE SHALL ALSO
RETURN LINE FROM CIRCULATING LOOP
FOR STORED TEMPERATURE WATER
(IF USEED)
CHECK
VALVE iii
FLO
REGULATING
PLUG COCK
TEMPERATURE AND
PRES. RELIEF VALVE
314" THICK (MIN.)
PIPE TO OUTSIDE OF
BUILDING k DISCHARGE
6" ABOVE GRADE COLD WATER
INLET LINE ---.
UNION
HEAT TRAP PER
ENERGY CODE
r/ II
v
HOT WATER J __�EO
SUPPLY LINE
i
EMBLEM AND
RATING PLATE
ELECTRICAL L_�
ACCESS PANELS
`y-- LINE TEMP.
CONTROL
ALL BRONZE
CIRCULATING
PUMP
�-- SHUT -OFF
VALVE
UNION
— ELECTRICAL
JUNCTION BOX
ELECT.
CONN.
IN .VALVE
WATER ' HEATER %' RN '. of x HOSE
PAN k (OMIT ,ON �` CONNECTION
GROUND -,aR,) ' xl
PAN DRAIN
PARALLEL TO
P&T •RELIEF
E ,
H.W.H. CIRCULATING PUMP DETAIL N.T.S.
EWH CAPACITY 80 GALLONS ENERGY EFFICENCY 0.85 MIN.
WATER PIPING SIZE -2
TQ
112"0
CW/HW
Q
112 "0
CW
Q
314 "0
CW,1 12 "O HW
d
3/4'"0
CW/HW
(5)
1 /2 "0
HW
� o
CD d
W W W-i
M
O
Fi
Q p
�W•�
O
Z
o'
e
c�
n:
h
i
•
n
0
�n
•
H
W
W
Ey
U)
Q
J/40 CWS
_
�
1 70 CWS
®
3/4,•0 HWS
o
co
TB
-170 CWS 11 /2 "O HWS
w
1�
1 -1 14 "OCWS I
°
U
z
1 "0 CWS /3 f 4 70 HWS
'
W
q
c7
0
Q
1-1/4 "0 CW,1 12 "0 HW
...1
W
Q
1 -1/4 70 CW, 314 "0 HW
polo
� ,ase r
O
rA
11 amindflmI
aaaaUQIQ1a
i
P.E. No 53288
Jose Antonia Mendez.
Professional Engineer 0 m m 0 B
mao�r�maammla
13$5 Coral Way Sufte #203 Miami, FL 33145 IMIUM RMUM0 IUD.
PH:(305)$54 -9924 FAX(305)656-1797
jose011 i (§a0l.com CA 00005324
�o •� zs c� Q,
sheen:. no.
- of -
b
x
U
11 amindflmI
aaaaUQIQ1a
i
P.E. No 53288
Jose Antonia Mendez.
Professional Engineer 0 m m 0 B
mao�r�maammla
13$5 Coral Way Sufte #203 Miami, FL 33145 IMIUM RMUM0 IUD.
PH:(305)$54 -9924 FAX(305)656-1797
jose011 i (§a0l.com CA 00005324
�o •� zs c� Q,
sheen:. no.
- of -