Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13-792-028
I - l P 1 OX8 RAG 20X12 12X12 RAG 22X10 CG 12x8 3W MASTER 250 CFM BEDROOM DREW'S BEDROOM CG 12X8 3W CG 12X8 3W STAIR C14 G 1 8 3W 200 CFM 200 CFM HALL ------ 75 CFM �--- b PEN TO N 8„0 ABOVE Gq 6X4 1 CFM G64 1W 0 C�M 1 4 "OGMD (26GA) UP AiL�V_ 4„O 6�0 THRU ROOF W /WP C INSECT SCREEN (CO 11.1 RESISTANT) & BDD F -1 \ 1e" UJ.LC. G 81 W--- 5 C MZLJ� 1 PROVIDE A MIN. OF 4" SPACE WHERE MECHANICAL - COMPONENTS TO ASSURE ADECUATE ACCESS FOR CONSTRUCTION do CLEANING. COIL /HEAT FAN SECTION SECTION 8110 RAG 12X12 10X10 4 „0 CG p �/ 5 �� M O 9'X8 "X8 10'X8 "m 8 "O 7'H 8 "H _ BATH °o CG 12X8 3W 4"0 ^- 41,GMD rt (26GA) UP 300 CFM U ROOF W /WP CAP, CG i 2X8 3W SECT SCREEN (CORROSION C 4 1 ESISTANT) k BDD GyM 225 CFM 4(; L GUE6T RAG EF -1 5Er)ROOM 12x12 2x12 „o FILTER ACCESS I OPEN TO aELOW rill- ---,AHU SHALL BE MECHANICALLY ATTACHED TO THE SUPPLY AIR PLENUM DUCT ,—CEILING -- - - WALLS �-- REF. LINES PROVIDE CAP OFF WITH 114" PERFORATED FOR VENT 12 MIN. DRAIN PAN W /WET DETECTOR TO CONTROL OVERFLOW BY J4 SHUTTING DOWN THE UNIT WHEN ACTIVATED. PREFAB MTL. FRAME F.F. A/C CLOSET INSTALLATION N. T. S. 8 "O O 11X10 Maximum Hanger C4 Spacing MASTER 4 ft 8#j 011 6 O 10'X81X8" and less than 46" f deep CG 8X6 1 W &rt # 48" and greater f than 16" deep Less than 29" wide aft and IF " depth or less MD G) E- -FOR R UST 6 „O �kIRU�QOF / P I I PROTECTION . D. D. (NO SCREEN in .. � CG 8X6 1 W � 100 CFM C 7 co • • • ' • EF -2 MAS//��}T�E'''1}R r� 6 "O 10 "X8 "X8" 6 "OGMD (26GA) UP 8 7H �- THRU A XF W /WP CAP, CG 10X6 2W INSECT SC REEN do BDD 125 CFM 4 70 C 6X4 1 "OGMD (26GA) UP 0 CFM MRU ROOF W /WP CAP, / INSECT SCREEN (CORROSION / RESISTANT) is BDD t I T 6"0G MD (22GA) UP THRU ROOF FOR KITCHEN EXHAUST BELOW W/W PROTECTION lc BIRD SCREEN. 4 "OGMD (26 ,`A) FOR EF -1 IN MAiD BATHROOM I L. f I� �I I� �I SECOND FLOOR MECHANICAL PLAN SCALE. 1/421 _ 11_0II N STANDARD 3" WiDE HANGERS Hanget extension to be the sum of the distances between the hanging wires and the duct size, ID (Smacna) Duct size, Inches Maximum Hanger C4 Spacing 48: Wide or grater 4 ft Less tha 48" wide loft and less than 46" deep Width between 28" &rt # 48" and greater than 16" deep Less than 29" wide aft and IF " depth or less CHANNEL SECTION IF Total Minimum Minimum Extension is Channel Channel not greater than_ Gauge. Profile 6" 24 3" X 1.5" 18" 22 3" X 2" 30" 18 3" X 2" USE OF 2" WILE 22 gauge 2'x IS" hangers may be substituted For 3" hangers For ducts with widths not over 48" and depths not over 24" provided that not more than one Joint occurs between hangers and the maximum hangar spacing 4ft. Exception: When duct perimeter is 8011 or less and does not require reinforcement two points are permitted between hangers EXHAUST FAN SPECS EF -1 SHALL BE "NUTONE" MODEL JLS -50 50 CFM 0114" W.C, 115 VOLTS, 80 WATTS CEILING MOUNTED W /B.D.D. BUILT -IN. EF -2 SHALL BE 'NUTONE" MODEL JLS -100 100 CFM 0114" W.C, 115 VOLTS, 80 WATTS CEILING MOUNTED W /B.D.D. BUILT -IN. MAINTAIN 1'-0" CLEAR FROM WALL CONDENSING 4" TY11YVE' UNIT MUST BE INSTALLED TO WITHSTAND 160 MPH HURRICANE FORCE WINDS do PROVIDE 1"X118- STRAP RE -DOWN TO UNIT 6 HANGERS AND SUPPORTS 4 "O EXHAUST DUCT STEEL HANGER WiRE TYPICAL CEILING CABINET EXHAUST FAN WITH BACKDRAFT DAMPER, LOW NOISE LEVEL AND NO VIBRATION. FRONT FACE GRILLE WITH FASTENING SCREENS EXHAUST FAN HANGING BRACKET (ADJUSTABLE) CEILING MOUNTED CABINET EXHAUST FAN DETAIL N. T. S. FASTENED INSIDE C.U. TO SLAB W/ 4 -114 "0 x 1 -112" POWDERED ACTUATED PINS AS PER MANUFACTURER SPEC'S POWER do CONTROL LOCATION O° 1ti M�N� LIQUID LINE W/ 0 iNSULA71ON SUCTION LINE W/ 1/2 ARMAFLEX INSULATION do VAPOR BARRIER NOTE. UNITS SHALL BE CLEAR BY 3" MIN. FROM DRIP LINE. CU MOUNTING D ET�'r 'I L Qa11WM0MI y, i�aa6� ©u6ma • C� .•` x, P.E. No 53288 r" q, ' Jose Antonio Mendez. Professional Engineer 1325 Cora( Way Suite #203 Miami, FL 33145 I•H:(305)254 -9224 F"(305)256-1797 amnaMaa®omla 6m®P 7 jose0112 @201.COm CA 00002324 0 • Z O 0 �M 1 4 J � Q) r 00 O 00 CV) ' E- W • O x nL� T u7 V L V Z m Wo��* A >M �- � W ... o >a Z O a` n k a a 0 .r H V1 W x U • V 1 � A C4 O a E- IT 04 E- in .. � x � rx 7 co • • • ' • U Z 60f • � W A O tv rcS LO 0 . s Tt U a HANGERS AND SUPPORTS 4 "O EXHAUST DUCT STEEL HANGER WiRE TYPICAL CEILING CABINET EXHAUST FAN WITH BACKDRAFT DAMPER, LOW NOISE LEVEL AND NO VIBRATION. FRONT FACE GRILLE WITH FASTENING SCREENS EXHAUST FAN HANGING BRACKET (ADJUSTABLE) CEILING MOUNTED CABINET EXHAUST FAN DETAIL N. T. S. FASTENED INSIDE C.U. TO SLAB W/ 4 -114 "0 x 1 -112" POWDERED ACTUATED PINS AS PER MANUFACTURER SPEC'S POWER do CONTROL LOCATION O° 1ti M�N� LIQUID LINE W/ 0 iNSULA71ON SUCTION LINE W/ 1/2 ARMAFLEX INSULATION do VAPOR BARRIER NOTE. UNITS SHALL BE CLEAR BY 3" MIN. FROM DRIP LINE. CU MOUNTING D ET�'r 'I L Qa11WM0MI y, i�aa6� ©u6ma • C� .•` x, P.E. No 53288 r" q, ' Jose Antonio Mendez. Professional Engineer 1325 Cora( Way Suite #203 Miami, FL 33145 I•H:(305)254 -9224 F"(305)256-1797 amnaMaa®omla 6m®P 7 jose0112 @201.COm CA 00002324 0 • Z O 0 �M 1 4 J � Q) r 00 O 00 CV) ' E- W • O x nL� T u7 V L V Z m Wo��* A >M �- � W ... o >a Z O a` n k a a 0 .r H V1 W x U • V 1 � A ��� Z �:-_ I I I OIII O C4 O a E- IT 04 E- in .. � x � rx 7 co w W U Z � W A O tv rcS LO ��� Z �:-_ I I I OIII O a� � � 7 O rcS � 0 b Tt U a sheet no. M-2 -of -