Loading...
13-792-005IRRIGATION NOTES AND SPECIFICATIONS IRRIGATION SYSTEM CONTROLLER O1. All work to be installed according to local and county codes by a licensed and insured irrigation I EXISTING 120 V WP. /GFI (2 AMPS) NO PUMP. Contractor. Contractor shall include all labor, materials, and equipment necessary to complete the work 0 RECEPTACLE TO REMAIN . MAKE detailed and intended in this plan. I HARD WIRE CONNECTION. 02. It is the contractor's responsibility to visit the site and become familiar with the existing conditions TMC- 212 -OD Controller 4 stations prior to entering into contract with the Owner or General Contractor. TORO Rain Sensor Model TRS N/A 03. All materials, quantities, sizes, and all other information contained in this plan shall be verified by 1 5� 1 112 G 3 * 12 C.U. THWN IN the contractor prior to entering into contract with the Owner or General Contractor. This plan is I 1/2 "CONDUIT. diagramatical and therefore site condition, scale of the plan and changes during construction, may I BACKFLOW affect the location of the system components. The contractor shall modify and /or adjust the system as I NEW W.P. SWITCH (D. S.) required so as to comply with full coverage and design intent. Performance specifications vary I 2" between different manufacturers and even within same manufacturer from year to year, therefore ' I IRRIGATION SYSTEM ELECTRICAL CONNECTION DETAIL irrigation contractor shall verify prior to entering into contract with Owner o Contractor, that all I N.T.S equipment, sizes, and dimentions including pump, mainlines, valves and lateral piping will provide the full coverage required. Should the contractor find a discrepancy, error or omission he shall contact the I © Landscape Architect immediately. I MPR PLUS NOZZLES (SIZE PER PLAN) 04. Piping in islands or narrow beds shall run to one side of the island or bed to allow for planting. h IZ NOTE: INSTALL SPRINKLER AT This includes mainlines and electrical wires. Piping and wiring should be installed after all the .75 - FINISHED GRADE large plant material has been installed. I 112" - Schedule 40 PVC Pipe - Sleeves =As APPROVED BACKFILL 05. The Landscape Architect has the right as Owner's authorized representative to at any stage V) substitution.Irrigation Contractor shall verify the G.P.M. discharge requirements for the irrigation pump, it shall meet the individual stations flow requirements, considering friction losses. of the works, inspect, accept or reject any and all work and materials which, in his opinion, do not meet 1 5' {N I I I NOTE: CONTRACTOR the requirements of the design intent. 27' ADJUSTABLE 40. PSI j KITCHEN j MAY INSTALL PIPE TO SIDE INLET 06. All bellow ground pipe shall be poly(vinyl chloride) (PVC) pipe comforming to ASTM I� MINI 2 I I specification D 1725, Schedule 40, or it may be PVC pipe conforming to ASTM D 2241, Class 200. rl I I w - - -- p Mainline shall always be schedule 40, as well as any above ground pipes. v lip =_ -- I �I SPRAY SPRINKLER BODY 07. All PVC fittings shall be Schedule 40, Type 1, NSF Approved conforming to the ASTM I 1.75 e BARBED MALE ELL D 2466 requirements, except as noted in the drawings. I HALL 8'r -1 5'r H FUNNY PIPE Oa. All sprinkler heads shall meet the performance called for in this plan, and shall all be from one 1 5' I TORO 570ZXF single manufacturer. Although all shrub heads are specified with a radius, contractor shall according to I LATERAL PIPE site conditions and space requirements, use the space required head or in some cases a different ' 1.75 pattern. XP -300 series sprinklers or other rotors are shown graphically as one pattern, use adjustable TORO 570ZXF part- circle as required. Spacing shall also be adjusted so as not to overthrow water into impervious MPR Plus 8'r -1 5'r F areas. 1.16 -4.20 LATERAL TEE 09. All valves shall be installed inside a plastic valve box of a size proper to the valve(s) size. TORO 12 "POP -UP SPRINKLER ON POLY SWING JOINT DETAIL. Valve boxes shall be installed over 3" of gravel for drainage and the top level with finished ^'r I BUBBLER grade. II- .25 N.T. S 10. All wire to /from controller to the electric valves shall be ##14, direct burial underground I 8' feed type. All connections shall be waterproof direct burial connectors and splices. All wire shall be I placed bellow the PVC pipe for protection of the wire, and shall be placed loosely to allow for Z I contraction. CLICK STOP SETTINGS - MEASURE RAINFALL IN 11. Thurst blocks shall be placed at all changes in direction of the main line. I QUANTITIES OF 1 /8" TO 1" 12. Trenching backfill shall be free of rocks, stones, or any other debris which may damage the pipes O� I ADJUSTABLE VENTILATION HOLES and wires. ,- I 10' ON U.V. STABILIZED VALOX 13. All spray heads to be on pop -up risers, 6" in sod areas & 12" in areas of ground covers. © 8' THERMOPLASTIC HOUSING They shall be installed so that the shrub head operates above the ground cover adult's height. r�•,r' I Contractor shall consult with Landscape Architect on specific height of plant beds prior to installation. Z I 14. Contractor all coordinate for the C sh with General Contractor, installation of sleeves under all paved areas prior to their installation. I TOTALLY SEALED & WEATHERPROOF 15. Backflow preventer if required shall be placed 18" min, above the highest sprinkler head. If heads c� SWITCH MECHANISM ( U.L. LISTED) above grade are included in the system design an RPZ Vacuum Beaker shall be installed instead of the Q I � ALUMINUM MOUNTING BRACKET standard AVE used when all heads are at ground level. O I O 16. Contractor shall, prior to installing the irrigation heads, flush all lines with the maximum water a 1 2 pressure available, to remove dirt and grit. Lines shall be pressure tested at 150% of their operating 12 V) LEAD WIRES re •s shall be done prior pressure for leaks, and all leaks shall be repaired. This p or to backfilling. I RAIN SENSOR DETAIL 17. Contractor is responsible for keeping the work premisses clean of debris, and for removing all debris caused by his work from the site. 18. If an irrigation submeter is being used, contractor shall adjust layout according to provided ' NOTE DETAIL MAY VARY ACCORDING TO SENSOR submeter s g.p.m, flow. MANUFACTURE (VERIFY) 19. Irrigation in right of way is not shown. Owner may request an extra zone(s) from I 1_12" irrigation contractor to water these area. K 12' I PLASTIC VALVE BOX WITH IRRIGATION CONTROLLER ^�+ I N I COVER MARKED "IRRIGATION" � AS SPECIFIED IN PLAN. I 112" IN TURF AND 2" IN EPDXY FILLED CONNECTORS I 12' GROUND COVER AREAS FINISH GRADE LATERAL LINE (COVER JUNCTION BOX 12' SOLENOID ACTUATED REMOTE AS NOTED) I CONTROL VALVE OMMON WIRE (PROVIDE 24" OF WIRE 1 -INCH PVC SCH 40 I IN A COIL) IN 2" PVC CONDUIT. CONDUIT TO POWER I 4" x 2 -1 J4" x 2" SOLID BRICK MAINLINE (COVER AS NOTED IN LEGEND SUPPLY AT EACH CORNER I I I COMMON AND CONTROL WIRES SCH 80 PVC NIPPLE WIRES TO REMOTE (PROVIDE 24" OF WIRE IN A COIL, EA.) CONTROL VALVES I MAINLINE (COVER AS NOTED) I REMOTE CONTROL VALVE DETAIL. I - - N.T.S WALL MOUNT CONTROLLER DETAIL I NOTE: USE 45 ELLS IMMEDIATELY OUTSIDE OF VALVE N.T.S I BOX, AS NECESSARY, FOR TRANSITION TO REQUIRED LATERAL LINE DEPTH. SYSTEM MASTER VALVE E IN BURIED VALVE BOX- -x _ BACKFLOW PREVENTER (IF CITY WATER USED) F1 .5 -INCH PVC SCH 40 CONDUIT AND FITTINGS TYPICAL IRRIGATION HEADS IN SOD AREAS. FEBCO MODEL 71OA/715 N.T.S ATMOSPHERIC VACUUM BREAKER ASSEMBLY FOR OUTSIDE INSTALLATION. IF REQUIRED DUE TO HEIGHT OF SPRINKLER HEADS, AN RPZ VACUUM BREAKER SHALL BE USED INSTEAD OF THE FEBCO MODEL SHOWN ABOVE `ICAL IRRIGAI IQN HEADS IN GROUND IER AREAS. SEE NOTE *13, IN GATION NOTES AND SPECIFICATIONS. GROUND COVERS AND /OR LOW SHRUBS INDIVIDUAL STATIONS SOLENOID VALVE IN BURIED VALVE BOX FINISH GRADE. BUNDLE IRRIGATION CONTROL WIRES w UNDER PIPES AT 10' INTERVALS AND 0 O Z Ln PROVIDE 1' EXPANSION LOOP AT 50' ii U INTERVALS. 0 < 0- z BACKFILL WITH PREVIOUSLY EXCAVATED MATERIAL. a t ;r�4�';�? ks �s k ;;s*r; ''' SAND OR FINE MATERIAL PASSING as - =�`_ � i�w' i�' =�' PIPE 1/4" SIEVE. PIPE OR CONDUIT (TYP.) 6" FOR PIPE 2" AND SMALLER AND 12" FOR PIPE 2 112" AND LARGER WHERE 4" FOR PIPE OR CONDUIT 2" AND CONTROL WIRE IS IN SAME TRENCH - SMALLER AND 12" FOR PIPE 2 112" IF ONLY ONE PIPE IN TRENCH, AND LARGER, WHERE NO WIRES IN PROVIDE 5" TO TRENCH WALL. TRENCH. TRENCHING DETAIL N.T.S NEW 4' HT. CHAIN LINK FENCE - X r _X 1 5 ' 1 / 2 3/4„ 1/2„ 1 5' 1 -1 /2" 15' IRRIGATION E U I PM ENT LEGEND Code Brand Description Size 0 X- 1 5 112" 4 "F. C. (� X - 15' -_C 12' TORO TMC- 212 -OD Controller 4 stations 3/4" TORO Rain Sensor Model TRS N/A 1/2" 15' (QUANITY & SIZE REQUIRED 1 2.25 i 22 � ° - - - -•- ; AS SHOWN IN PLAN) I ate. 0 0 TORO Series 252 Electric Valves As required. O BACKFLOW .06 PREVENTER 000 i- - - - - -- O A O -- - - - - -� TORO Master Valve 2" 0 SPECIFIED IN G CHICAGO BRICK 11..< 4•' TORO Pump Relay N/A © - Self- Priming, Single Phase Electric Pump 55 GPM - - - - -- - Schedule 40 PVC Pipe - Main Line As shown .75 - Class 200 PVC Pipe - Lateral Lines As shown - -- - Schedule 40 PVC Pipe - Sleeves =As required Note: Irrigation Contractor may substitute the brand name specified for another brand,however, the same performance is required for each substitution.Irrigation Contractor shall verify the G.P.M. discharge requirements for the irrigation pump, it shall meet the individual stations flow requirements, considering friction losses. EQUIPMENT NOTES-. 1. EQUIPMENT MOUNTING Irrigation equipment are to be located next to pump location as shown in plan. The equipment, shown in plan and typical electrical schematic diagram shall be mounted onthe building wall or on a Unistrut frame set into a 16" x 10" deep concrete footing x 6" longer than both ends of the Unistrut structure's length. 2. WORK PERFORMANCE: All electrical work to be performed by a licensed and insured electrical contractor, in strict compliance with all sections of Article 680 of the National Electrical Code, Latest Edition. 12' 1/2" e /4 15' o'1 15' 1 -1 12" 1 5'kl COVERED TERRACE I ' I I I I I I I I I I I I II I I 1111 J 11- I LAUNDRY II I ILI FAMILY j n ROOM j ----------- � I I I I I DINING %OM I I I - _ - _---- - - - - -- I I 1 I STAIR HALL FOYER - I •• a' a' L J N N a' 2' I j COVERED ! ENTRY I a' •Y•• ••r t • ••••r •r• • Y• • • ! Y Y Y Y • �•r•V rr••y • r �+ c,r•u • • • 5' -0" HIGH, 4' -0" WIDE ALUM. ACCESS GATE WITH • Is* • • • • Go SELF - CLOSING DEVICE AND SELF - LATCHING DEVICE TO BE • • • • • a a •�• LOCATED ON THE POOL SIDE MIN. 3" BELOW TOR OF GATE TO '•' •;• �•` ; `l " T 1 • COMPLY WITH r.B.C. O o :•••• •r••� ••••• - ••rte• co r CQ 15' 15' 1/2„ 15' .i••• •• + i i b o • • • • • • co ••r�• Y ••••• • •v• .emu., � l() �,.,, " Nn / r-------------- - - - - -1 O W 'M p � R - -- i - -- I I 1 235 SF I 12' - -_-� L - -- 15' j RESERVED AREA i 15' O Ix C r -� a Z 2 CAR GARAGE 15, � I I zo 15' zo � I I I rr1 � I I 1 I I 00 N k I i I Z I 470 SF I n DRAINFIELD - -- _- _- _- _-- _- _--- _ -_ -_ -_ _ #2 - - - _ i O ° 1 /2° INSIDE SLEEVE 0 jPOWDER STORAGE ROOM I I 5• ,�- r:.- ��'` � PROPERTY LINE 135.69' S 00 00' 38" 3#6 THW /CU IN 1 "C. - 112" X- 1 5 112" 4 "F. C. (� X - 15' -_C 12' X 1 5' 3/4.. 6" 3/4" 15, 3/4,: 15' SOD 1/2" 15' (QUANITY & SIZE REQUIRED 1 2.25 i 22 � ° - - - -•- ; AS SHOWN IN PLAN) I ate. 0 0 - - - - -- 1 5 15' G i I - 3/4.. 1 -1 /if„ BACKFLOW .06 PREVENTER 000 i- - - - - -- O A O -- - - - - -� 15' y, y:, ;ta. . • Provide cross - visibility at ' = .:1 :,4• %•'''1fV5(D := .,;.1j r '': height between (3) and (6) SPECIFIED IN G CHICAGO BRICK 11..< 4•' DRIVEWAY ON SAND 1 5' (locate within 5'of property line.) I j I I ,Y MAID BATH MAID'S SCHEMATIC DIAGRAM I 265 SF RESERVED I .75 27' ADJUSTABLE I ' ` LL BEDROOM 8' Q I AREA 12" .75 iv BAR II - I I� "" ,�. � II ICI r,•� L---- - - - - -J - -. 112" .9 I I r- I {N I I I ry I � I r I I .75 27' ADJUSTABLE 40. PSI j KITCHEN j i f `1 TORO MINI 2 I I BREAKFAST rl I I w - - -- p TORO 570ZXF =_ -- I �I L _J wa 40. PSI 0.26 -1.45 1.75 e j j 570ZXF I I HALL I II I I 1111 J 11- I LAUNDRY II I ILI FAMILY j n ROOM j ----------- � I I I I I DINING %OM I I I - _ - _---- - - - - -- I I 1 I STAIR HALL FOYER - I •• a' a' L J N N a' 2' I j COVERED ! ENTRY I a' •Y•• ••r t • ••••r •r• • Y• • • ! Y Y Y Y • �•r•V rr••y • r �+ c,r•u • • • 5' -0" HIGH, 4' -0" WIDE ALUM. ACCESS GATE WITH • Is* • • • • Go SELF - CLOSING DEVICE AND SELF - LATCHING DEVICE TO BE • • • • • a a •�• LOCATED ON THE POOL SIDE MIN. 3" BELOW TOR OF GATE TO '•' •;• �•` ; `l " T 1 • COMPLY WITH r.B.C. O o :•••• •r••� ••••• - ••rte• co r CQ 15' 15' 1/2„ 15' .i••• •• + i i b o • • • • • • co ••r�• Y ••••• • •v• .emu., � l() �,.,, " Nn / r-------------- - - - - -1 O W 'M p � R - -- i - -- I I 1 235 SF I 12' - -_-� L - -- 15' j RESERVED AREA i 15' O Ix C r -� a Z 2 CAR GARAGE 15, � I I zo 15' zo � I I I rr1 � I I 1 I I 00 N k I i I Z I 470 SF I n DRAINFIELD - -- _- _- _- _-- _- _--- _ -_ -_ -_ _ #2 - - - _ i O ° 1 /2° INSIDE SLEEVE 0 a' - - EIF-12 S C 15' 15 RAI EN 1 /2" 1 J2' 8I 1 5 N CON OLLE Pool 1 2, EQUIP. 12' I V 3/4" 1/2" 12' 12' 1 1 2' I 530 SF i w MASTER VALVE SHUT OFF VALVL(TYR.) 6' DRAINFIE D j 2 w RPZ. BACK FLOW I 3/4" * 1 I I I 0 > 4 3 2 1 V M O O i ON r 2" 45.00 G. ►.M. w � � / � ' L - - --I M<11N IRRIGATION LINE - I� • 1- 1z ^z..soc.r.M. �- - - -- -- - - - - -- -- . . _.. ..�..�. _......_..�-- WM 3 1-1;2" 26.00 G.P.M. 1 1 �5' VERIFY LOCATION 15' 3/4„ 1 -1/4" 12' 1 -112" aa,121 1/2" 12' 1/2" 12' 112„ 1/2, 1„ 2• 2' 1„ 15' 3/4' � - x -x PROPERTY LINE 150-82' S 00 00' 38" E 5' -0" HIGH, 4' -0" WIDE ALUM. ACCESS GATE WITH NEW 4' HT. SELF - CLOSING DEVICE AND SELF - LATCHING DEVICE TO BE CHAIN LINK FENCE LOCATED ON THE POOL SIDE MIN. 3" BELOW TOP OF GATE TO COMPLY WITH F.Q.C. 24 V IRRIG. WIRE jPOWDER STORAGE ROOM I I 5• ,�- r:.- ��'` � CONTROLLER 1.25 i i w 3#6 THW /CU IN 1 "C. I 15' Z 3 4 "F. C. (� ELECTRICAL PANEL I I I TORO I I 6" r W 5'X 18' a 24 V CONTROL WIRES ZONE - 24V ELECT. VALVES O (QUANITY & SIZE REQUIRED 1 2.25 i 22 � ° - - - -•- ; AS SHOWN IN PLAN) I ate. 0 0 - - - - -- 1 5 15' G i I - 3/4.. 1 -1 /if„ BACKFLOW - - -- - - - -- - -- 4 "F.C.b - - - -- J PREVENTER TYPICAL VISILLLT)� IANG 15' y, y:, ;ta. . • Provide cross - visibility at ' PVC PIPE AS .:1 :,4• %•'''1fV5(D := .,;.1j r '': height between (3) and (6) SPECIFIED IN �:L1r;E�(•. +`�' :� °,' above grade. CHICAGO BRICK 11..< 4•' DRIVEWAY ON SAND : J `: ;.I!ER?1a(Qt1S (locate within 5'of property line.) W •�x � MEDIA y �I i ROOM I �prr ROOM .CAT1r i WET lI' �,I I I ,Y �� IRRIGATION SCHEMATIC DIAGRAM I 265 SF RESERVED I .75 a' - - EIF-12 S C 15' 15 RAI EN 1 /2" 1 J2' 8I 1 5 N CON OLLE Pool 1 2, EQUIP. 12' I V 3/4" 1/2" 12' 12' 1 1 2' I 530 SF i w MASTER VALVE SHUT OFF VALVL(TYR.) 6' DRAINFIE D j 2 w RPZ. BACK FLOW I 3/4" * 1 I I I 0 > 4 3 2 1 V M O O i ON r 2" 45.00 G. ►.M. w � � / � ' L - - --I M<11N IRRIGATION LINE - I� • 1- 1z ^z..soc.r.M. �- - - -- -- - - - - -- -- . . _.. ..�..�. _......_..�-- WM 3 1-1;2" 26.00 G.P.M. 1 1 �5' VERIFY LOCATION 15' 3/4„ 1 -1/4" 12' 1 -112" aa,121 1/2" 12' 1/2" 12' 112„ 1/2, 1„ 2• 2' 1„ 15' 3/4' � - x -x PROPERTY LINE 150-82' S 00 00' 38" E 5' -0" HIGH, 4' -0" WIDE ALUM. ACCESS GATE WITH NEW 4' HT. SELF - CLOSING DEVICE AND SELF - LATCHING DEVICE TO BE CHAIN LINK FENCE LOCATED ON THE POOL SIDE MIN. 3" BELOW TOP OF GATE TO COMPLY WITH F.Q.C. 24 V IRRIG. WIRE jPOWDER STORAGE ROOM I I 5• ,�- r:.- ��'` � CONTROLLER 24.50 3#6 THW /CU IN 1 "C. RAIN 3 :.. ELECTRICAL PANEL I TORO 1 *8 THW /CU IN 1/2"C 6" (GROUND PER NEC) 5'X 18' 2 -5 /E "x10' CU /CUD ' 24 V CONTROL WIRES ZONE - 24V ELECT. VALVES GROUND RODS I (QUANITY & SIZE REQUIRED � � ° - - - -•- ; AS SHOWN IN PLAN) -- - - - - -- 24 V GROUND WIRE G i I - (COMMON) BACKFLOW ❑� PREVENTER 1 1/2„15. 15' I PVC PIPE AS i LIVING I I SPECIFIED IN 1.38 PLAN WATER METER WM I 6" (locate within 5'of property line.) 9'X 20' � MEDIA y �I i ROOM I �prr ROOM .CAT1r i WET lI' �,I I I 1.38 �� IRRIGATION SCHEMATIC DIAGRAM I 265 SF RESERVED I .75 27' ADJUSTABLE I ' ` LL .9 8' Q TORO AREA 12" .75 iv BAR II - I I� "" ,�. � II ICI r,•� L---- - - - - -J - -. 112" .9 .15 # TORO I I I ry I � I r I I .75 27' ADJUSTABLE 40. PSI -J - .15 I# TORO MINI 2 I I 27' ADJUSTABLE a' - - EIF-12 S C 15' 15 RAI EN 1 /2" 1 J2' 8I 1 5 N CON OLLE Pool 1 2, EQUIP. 12' I V 3/4" 1/2" 12' 12' 1 1 2' I 530 SF i w MASTER VALVE SHUT OFF VALVL(TYR.) 6' DRAINFIE D j 2 w RPZ. BACK FLOW I 3/4" * 1 I I I 0 > 4 3 2 1 V M O O i ON r 2" 45.00 G. ►.M. w � � / � ' L - - --I M<11N IRRIGATION LINE - I� • 1- 1z ^z..soc.r.M. �- - - -- -- - - - - -- -- . . _.. ..�..�. _......_..�-- WM 3 1-1;2" 26.00 G.P.M. 1 1 �5' VERIFY LOCATION 15' 3/4„ 1 -1/4" 12' 1 -112" aa,121 1/2" 12' 1/2" 12' 112„ 1/2, 1„ 2• 2' 1„ 15' 3/4' � - x -x PROPERTY LINE 150-82' S 00 00' 38" E 5' -0" HIGH, 4' -0" WIDE ALUM. ACCESS GATE WITH NEW 4' HT. SELF - CLOSING DEVICE AND SELF - LATCHING DEVICE TO BE CHAIN LINK FENCE LOCATED ON THE POOL SIDE MIN. 3" BELOW TOP OF GATE TO COMPLY WITH F.Q.C. 24 V IRRIG. WIRE IRRIGATION CONTROLLER 24.50 3#6 THW /CU IN 1 "C. RAIN 3 SENSOR ELECTRICAL PANEL s C TORO 1 *8 THW /CU IN 1/2"C 6" (GROUND PER NEC) 5'X 18' 2 -5 /E "x10' CU /CUD ' 24 V CONTROL WIRES ZONE - 24V ELECT. VALVES GROUND RODS I (QUANITY & SIZE REQUIRED � � ° - - - -•- ; AS SHOWN IN PLAN) -- - - - - -- 24 V GROUND WIRE V #t (COMMON) BACKFLOW ❑� PREVENTER ZONE 24V ELECT. See Note 15. MASTERVALVE PVC PIPE AS 40. PSI SPECIFIED IN 1.38 PLAN WATER METER WM SM ,5" IRRIGATION SUB -METER 6" (locate within 5'of property line.) 9'X 20' Typical Shut off 1.38 valve IRRIGATION SCHEMATIC DIAGRAM N.T.S. 12" STATIONS FLOW RATE 1 24.50 2 26.00 3 30.00 4 45.00 TORO MPR570 6" 4 -EST SCALE: %j" = V Note: Hose bib shall be supplied within 75'of all landscape areas SYMBOL BRAND MODEL BODY RISER NOZZLE RADIUS PATTERN DESIGN PRESSURE FLOW G.P.M PRECIPIT. RATE Q TORO MPR570 6" 4 -EST 5'X 18' 40. PSI .53 1.13 ❑ TORO MPR570 6" 4S -SST 5' X 18' 40. PSI .63 1.60 ❑� TORO MPR570 6" 2 -SST TX 7' 40. PSI .10 1.38 Z W TORO MPK570 6" 9 -SST 9'X 20' 40. PSI 1.38 1.48 N ' TORO MINI 8 12" .75 27' ADJUSTABLE 40. PSI .9 .15 Q TORO MINI a 12" .75 27' ADJUSTABLE 40. PSI .9 .15 # TORO MINI 8 12" .75 27' ADJUSTABLE 40. PSI .9 .15 I# TORO MINI 2 12" .75 27' ADJUSTABLE 40. PSI .9 .15 p TORO 570ZXF 6" MPR Plus 8'r -1 5'r Q 40. PSI 0.26 -1.45 1.75 e TORO 570ZXF 6" MPR Plus 8'r -1 5'r H 40. PSI 0.52 -2.02 1.75 TORO 570ZXF 6" MPR Plus 8'r -1 5'r TQ 40. PSI 0.86 -3.00 1.75 TORO 570ZXF 6" MPR Plus 8'r -1 5'r F 40. PSI 1.16 -4.20 1.75 • TORO FI -25 -PC 1 6" MPR Plus BUBBLER 40. PSI .25 1.55 L Ln Uw c0O J W M 7- �-� co 0© Q = C/a N C Cn _J Lo �O ¢ co A E O a � O W F ctf V 1 � O Q O � O E+ W W U H Q U)- . , CU Z C0 2E x r- L'QIt LJ EU c0 Z W � A N \ M� N ' to I� 4 321 411 .1 -3 O m 0 A N O a � .J V 1 � E+ W W H x r- 0 c0 Z W � A N m 0 .J I� U -3 O 04 O � W _P cc b N O Know what's bellow Call before Wu dig. It's the Law! c6 r sheet no. LA -3.0 y_ 1 of MAX. a