09-860-019GENERAL NOTE5 - ELECTRICAL .
I.-DO NOT SCALE ELECTRICAL DRAWINGS, REFER TO ARCHITECTURAL PLANS AND
ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPMENT AND CONFIRM WITH
OWNERS' REPRESENTATIVE.
2- ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE NEC
THE NFPA 10 4 SHALL COMPLY WITH THE CURRENT FLORIDA BUILDING CODE, AND ALL
STATE AND LOCAL RULES AND ORDINANCES.
3: MINIMUM WIRE SIZE SHALL BE NO, 14 AWG, EXCLUDING CONTROL WIRING, UNLESS
OTHERWISE INDICATED, ALSO, UNLESS OTHERWISE INDICATED, ALL CONDUCTORS
SHALL BE COPPER WITH THW OR THH AUM INSULATION FOR SIXES NO.6 AND SMALLER
CONDUCTORS LARGER THAN NO.6 SHALL HAVE TYPE T14W NO.8 AND LARGER SHALL
BE STRANDED. ALL RACEWAYS AND PIPES PLACED IN OR THROUGH ANY CONCRETE
SLAB SHALL BE SPACED A MINIMUM OF 3 DIAMETERS OF THE LARGEST CONDUIT OR
PIPE OF ANY OTHER SERVICE :(WHEN APPLICABLE)
4.- ALL RACEWAYS UNDERGROUND AND /OR LARGER THAN 2 INCHES IN DIAMETER
SHALL BE GALVANIZED RIGID STEEL. PVC PIPE SCH. 40 WILL BE ACCEPTABLE IF
APPROVED BY LOCAL REGULATIONS, CONTRACTOR TO VERIFY. ALL OTHER
RACEWAYS 2 INCHES AND SMALLER IN DIAMETER MAY BE EXT. WHEN ABOVE GROUND
5.- OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, AND CAST ALLOY
WITH THREADED HUBS IN WET OR DAMP LOCATIONS (4" x 4" MINIMUM $IZE).
6.- DISCONNECT SWITCHES SHALL BE HORSEPOWER RATED, HEAVY DUTY,
QUICK -MAKE, QUICK- BREAK, N NEMA } OR 3R ENCLOSURE AS REQUIRED BY
EXPOSURE.
1: IT IS NOT THE INTENT OF THESE PLANS TO SHOO) EVERY MINOR DETAIL OF
CONSTRUCTION. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL
ITEMS FOR A COMPLETE ELECTRICAL SYSTEM, AND PROVIDE ALL REQUIREMENTS
NECESSARY FOR EQUIPMENT TO BE PLACED N PROPER WORKING ORDER
8. MOTOR STARTERS SHALL BE MANUAL OR MAGNETIC WITH THREE OVERLOAD
RELAYS.
9.- THE ELECTRICAL SYSTEM SHALL BE FULLY OPERATIONAL AND TESTED, AS
WELL AS COMPLETELY GROUNDED AS REQUIRED BY THE N.E.C.
10- LOAD DATA IS BASED ON INFORMATION GIVEN TO THE ENGINEER AT THE TIME
OF DESIGN. VERIFY ALL EQUIPMENT CONDUCTOR SIZE, PROTECTION, ETC.
REQUIREMENTS PRIOR TO ORDERING PANEL BOARDS, OR PRIOR TO INSTALLATION.
II: ALL MATERIALS, DEVICES OR APPLIANCES SHALL BE LISTED AND BEAR WITH THE
STANDARDS OF UNDERWRITERS LABORATORIES (UL) OR ANY APPROVED NATIONALLY
RECOGNIZED LABORATORY
12: ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN
A FIRST CLASS WORCMANLIKE MANNER THE COMPLETED SYSTEM SHALL BE FULLY
OPERATIVE AND ACCEPTANCE BY ENGNEERIARC 41TECT MUST BE A CONDITION OF
THE CONTRACT.
13.- ALL WOW SHALL BE C 0RDINIATED WITH OTHER TRADES TO AVOID
INTERFERENCE WITH PROGRESS OF CONSTRICTION.
14.- CONTRACTOR SHALL GUARANTEE ALL MATERIALS, EQUIPMENT AND WORKMANSHIP
ARE FREE OF DEFECT FOR A PERIOD OF NO LESS THAN ONE YEAR FROM THE DATE OF
ACCEPTANCE,
ELECTRICAL LEGEND
SURFACE MOUNTED INCANDESCENT OR FLUORESCENT LIGHT
FIXTURE I2OV, IOOW MAX.
0 RECESSED INCANDESCENT LIGHT FIXTURE 120V, }OOW MAX.
• RECESSED INCANDESCENT LIGHT FIXTURE 120V, 5OW MAX.
WALL MOUNTED INCANDESCENT FIXTURE OUTLET. MOUNTING
HEIGHT TO BE VERIFIED WITH ARCHITECT AND /OR OWNER.
DUPLEX RECEPTACLE 3 POLE, 3 WIRE, 125V, 20A,
MOUNTED AT IS" APP.
DUPLEX RECEPTACLE 3 POLE, 3 Win, 125Y, 20A,
WITH ARC -FAULT INTERRUPTER PROTECTION MOUNTED AT IS" APP.
SINGLE POLE TOGGLE SWITCH 20A, 120V MOUNTED 48" AFF.
3 -WAY TOGGLE SWITCH 20A, 120V MOUNTED 48" APP.
D DIMMER SWITCH LUTRON NOVA SERIES 120V,150OW OR
EQUIVALENT, MOUNTED AT 48" APP.
T TELEPHONE OUTLET, WALL MOUNTED AT 18" APP.
CEILING OR WALL MOUNTED JUNCTION BOX WITH COVER, TO
SUIT LOCATION.
n TV /CABLE OUTLET, WALL MOUNTED AT 18" APP.
T® EF EXHAUST FAN MOTOR CONNECTION (FRACTIONAL HORSEPOWER)
DISCONNECT SWITCH TYPE AND SIZE AS SHOILN
sD SMOKE DETECTOR 120V TYPE WITH BATTERY BACKUP
(SEE PLAN NOTES)
- - -- CONDUIT MINI CONCEALED N CEILING OR WALLS.
CONDUIT RUN UNDERGROUND, N OR BELOW FLOOR SLAB.
IQI ELECTRICAL PANEL SIZE AND RATING AS SHOWN (SEE SCHEDULES)
GF.I. INDICATES GROUND FAULT INTERRUPTER.
W.P. INDICATES WEATHERPROOF, NEMA 3R ENCLOSURE.
E INDICATES EXISTING EQUIPMENT TO REMAIN.
ER INDICATES EXISTING EQUIPMENT RELOCATED AS SHOW
F INDICATES FUTURE: ELECTRICAL EQUIPMENT NOT INSTALLED UNDER
THIS CONTRACT.
15.- CONTRACTOR SHALL REMOVE ALL DEBRIS AND UNUSED FIXTURES AND RETURN
TO OWNER OR DISPOSE OF PROPERLY IF $O DIRECTED BY OWNER
I&.- CONTRACTOR SHALL INCLUDE IN HIS PRICE, PERMIT, TAXES AND /OR IMPACT FEES,
INSURANCE, ETC. AND ENGINEERING FEES FOR PREPARATICN OF AS -BUILT DRAWINGS.
Il: IT IS SUGGESTED THAT THE CONTRACTOR CONFER WITH LOCAL UTILITY TO
LOCATE THE ELECTRIC METER TO COMPLY WITH FEMA REQUIREMENTS
18.- ALL CONTROL WIRES AND CONNECTIONS REQUIRED FOR ALL ELECTRICAL
APPLIANCES, AIR CONDITIONING AND VENTILATING EQUIPMENT OPERATION
SHALL BE PROVIDED AND TESTED FOR A FULLY OPERATIONAL SYSTEM.
}9.- MAINTAIN 12" MINIMUM SEPARATION BETWEEN OUTLET BOXES ON OPPOSITE
SIDES OF SOUND INSULATED WALLS
20: CLAIMS FOR EXTRA WORK DUE TO MEETING CODE REQUIREMENTS
WILL NOT BE CONSIDERED.
2I. -ALL LIGHTING FIXTURES COLOR FINISH SHALL BE SELECTED BY ARCHITECT OWNER
REPRESENTATIVE BEFORE ORDERING.
22.- CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND VERIFY EXACT
LOCATIONS PRIOR TO BIDDING THE PROJECT.
23.- VERIFY AT FIELD WITH ARCHITECT OWNER REPRESENTATIVE EXACT LOCATION OF
SIGNAL OUTLETS, LIGHT FIXTURES CONTROL SWITCHES AND WALL FIXTURES MOUNTING
HEIGHT BEFORE ROUGHING -IN.
24.- COORDINATE W/ OUTER TYPE OF DATA PROVIDER BEFORE INSTALLATION OF
OUTLETS.
25 -ALL DUPLEX RECEPTACLES SHALL BE 125V- 15A -2P -3W GROUNDED, STANDARD
GRADE, COLOR SELECTED AND APPROVED BY ARCHITECT.
26- ALL LIGHT SWITCHES SHALL BE 1 POLE TOGGLE 125V RATED 20A, COLOR
SELECTED AND APPROVED BY ARCHITECT.
21 -ALL RECEPTACLES SHALL BE WIRED N ACCORDANCE WITH N.E.C. TO ENDURE
CORRECT POLARITY.
28.- CIRCUIT NUMBERS SHOWN ARE FOR IDENTIFICATION ONLY. IT SHALL BE THE
ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO COMPLETE PHASE
PANEL BOARD (BALANCE LOAD).
29. -ALL JUNCTION AND PULL -BOXES SHALL BE ACCESSIBLE ALL THE TIME.
30. -ALL RACEWAY ROUTED, INSULATED CONDUCTORS SYSTEM SHALL BE COLOR
CODED AS FOLLOWS:
120/240V SYSTEM
PHASE "A ": BLACK
PHASE "B ": RED
NEUTRAL : WHITE
GROUND : GREEN
3I. -ALL EXTERIOR ELECTRICAL EQUIPMENT SHALL BE WEATHER - PROOF.
LOAD SUMMARY
PANEL 'A'
AIR CONDITIONING LOAD
AHU -1 ------------------ ------ ----- --- ------- - - - - - -- -},244 VA
AHU -2 ----------------------------------------- - - - - -- 6,984VA
OTHER LOADS
(1) GENERAL LIGHTING 2,7190 Sl:.e 3W /SF - - - - - - - - - - 8,310
SMALL APPLIANCES 2 x 1500W -------- - - ---- 3,000
GAS COOKTOP/FAN UNIT -------------- - - - - -- 1,000
D5L -OVEN UNIT ------------------------------ 3,200
MICROWAVE -------------------------- - - - - -- 1,500
DISH WASHER ------- -- -------- ---- -- - - - - - -- 1,500
GARB DISP. ---------------------------- - 1,100
REF/ COOLER--------------------------- - - - - -- I,600
EWH---------- ----------- --- --- ----- - - - - - -- 4,500
WASHER ------------------------------- - - - - -- 1,300
DRYER ---------- --- -- --- ----- --- ---- --- - -- 5,000
OTHER LOADS TOTAL - 32,0'10 -- 32,010 VA
46,298VA
46,298 VA / 240V = 192.9 AMPS (ESTIMATED LOAD)
EXISTING A 200 A SERVICE WITH 303/0 THW CU
IN 2'G (FULL NEUTRAL) TO REMAIN.
------------------------------------------------------------
NOTES:
(1) AIR CONDITIONING FLOOR AREA PER NEC 22030(5X2)
EXISTING 2,480 60-FT PLUS NEW AREA ADDED 310 60-FT
TOTAL OF 2,7190 80 -FT.
LOAD SUMMARY
PANEL 'B'
AIR CONDITIONING LOAD
AC -I ----------------------------------------- - - - - -- 6,120 VA
AC -2 ----------------------------------------- - - - - -- 5,568 VA
NEW AC -3 (DUCTLESS) -------- ------ ---------- - - - - - -- 1,440 VA
OTHER LOADS
POOL PUMP --------------------------- - - - - -- 2,300
POOL EQ. ---------------------------- - - - - -- 4,200
POOL LTS. ----------------------------- - - - - -- 500
OTHER LOADS TOTAL 1,000 VA -1000 VA
20,'128 VA
20,126 VA / 240V = 86.4 AMPS (ESTIMATED LOAD)
EXISTING 100 A SERVICE WITH 303 THW CU
IN 1 -1/4 "C (FULL NEUTRAL) TO REMAIN.
FEEDER AND SERVICE LOAD CALCULATION
PER N.E.C. ARTICLE 22030
(MAIN FEEDER)
AIR CONDITIONING LOAD
(PER N.E.G. OPTIONAL CALC. 22030(CX4))
AC UNIT 01 --------------------------------------- - - - - -- '11244 VA
AC UNIT 02 --------------------------------------------- 6,984 VA
AC UNIT 03 (NEW) --------------------------------- - - - - -- 1,440 VA
OTHER LOADS
PANEL 'A' ---------------------------- - - - - -- 32,010
PANEL'B' ---------------------------- - - - - -- 1000
SPRINKLER PUMP ----- ------ --- ------- - - - - -- 1,900
OTHER LOADS TOTAL 40,910 VA
FIRST 10,000 VA AT 1009s 10000 VA ----------------- 10,000 VA
NEXT 30,910 VA AT 40516 12,386 VA ----- ---- -- -- - -- - -- 12,385 VA
38,056 VA / 240V = 158.6 AMPS (ESTIMATED LOAD) 38,056 VA
EXISTING A 200 A SERVICE WITH 303/0 THW CU IN 2'C (FULL NEUTRAL)
TO REMAIN WITH NEW 104 THW CU SERVICE GROUND WIRE.
PROVIDE NEW GROUND SERVICE (REFER TO RISER DIAGRAM)
NOTES:
(1) PER N.E.G. ART 310.15 (5X6) SINGLE -PHASE DWELLING
SERVICES AND FEEDERS.
11,
(1)
(1)
(2)(5
(2)l3
(2)l3
(1)
ll)
11)
FEED WITH: EXISTING 303/0 THW CU IN VC TO REMAIN.
TYPE: SIEMENS LOAD CENTER MODIFICATION: --
VOLTAGE 120/24OV, IPH, 3W I I I ENCLOSURE: NEMA 1, RECESSED
MAINS: 225 A MLA. ����
LOCATION: CORRIDOR AREA
A.I.C.S.: 10,000 (EXISTING TO REMAIN) FED FROM: MAIN "A"-METER/F.P.L. Co.
DESCRIPTION
WIRE AND
CONDSIZE
LOAD
(VA)
POLE
TRIP
CT.
No
VOLTAGE 120/24OV, IPH, 3W
WV
PANEL
CT.
No
POLE
TRIP
LOAD
(VA)
WIRE AND
CONDSIZE
DESCRIPTION
GAS /STOVE -FAN UNIT
EXIST
500
2
30
1
2
2
50
1600
EXIST
OVEN UNIT
POLE
CT.
500
3
4
1600
WIRE AND
1T0NN
AHU -2
EXIST
3492
2
.50
5
6
2
60
3622
EXIST
AHU -1
CONDSIZE
3492
7
8
3622
2
1
LTS 4 REC
EXIST
3W /6F
1/20
9
10
y3o
2250
EXIST
EWH
1
LTS 4 REC
EXIST
3W /SF
1/20
11
12
2250
to
LIVING RM 4 PORCH
EXIST
3W/SF
1/20
13
14
1/20
3W /SF
EXIST
BEDROOM HALLWAY
POOL EQ
DRYER
EXIST
2500
2
30
15
18
I/20
3W /SF
EXIST
LTS 4 REC
8
2500
17
18
1/20
3W /SF
EXIST
MASTER BEDROOM
145
9
LTS 4 REC
EXIST
3W /SF
1/20
19
20
1/20
3W /SF
EXIST
CAROLYN'S BATHROOM
!!
d12
LTS 4 MC
EXIST
3W /SF
1/15
21
22
1/20
3W /SF
EXIST
MASTER BATH 4 HALLWAY CLO
LTS 4 REC
EXIST
3W /SF
1/15
23
24
1/20
1300
EXIST
WASHER
KITCHEN/FAM RM LTS
EXIST
3W /SF
1/15
25
28
I/20
3W /SF
EXIST
LTS 4 REC
LTS 4 REG
EXIST
3W /SF
1/15
27
28
1/20
3W /SF
EXIST
GUEST BATHROOM
0
LTS 4 REC
EXIST
3W /6F
1/20
29
30
1/15
3W /SF
EXIST
NEW HALLWAY, GUEST BR, LAUN
GARB DISP.
EXIST
1100
1/20
371
32
1/15
3W /SF
EXIST
LTS 4 REC
FAM RM REC/U1ALL TV
EXIST
3W /SF
1/20
33
34
Z
20
1204
EXIST
REFRPGERATOR
DISHWASHERMICROWAVE OVEN
EXIST
2830
1/1 /20
35
38
1200
PROP BED ROOM
14,1/2"
3W/SF
1/15
37
381
3W /SF
12,1/2"
LTS t REC /NEW COV tERR
PROP BED ROOM
14,1/2"
3W/SF
I/S
39
40
Ag
3W /SF
014,1/2"
HALLWAY CLO / NEW CORK -EXT
APPLIANCE /APPLIANCE
EXIST 13000
U911-2-01411
42
it AS I
3W /SF
EXIST
LTS 4 REC / LTS 4 REG
PHASE A: _� -NVA PHASE B: _�___VA TOTAL: __- VA_f 4) ._._AMPS.
t II VtKIPT AT FIELD EXISTINCx CIRCUIT TO REMAIN. CONTRACTOR SHALL LABEL ALL CIRCUIT BREAKERS AT THIS PANEL
ACCORDINGLY TO THE LOAD SERVED, PROVIDE TYPEWRITTEN PANEL BOARD DIRECTORIES, NO HAND WRITTEN LABELS
(2) CIRCUIT UNDER THIS CONTRACT. PROVIDE NEW CIRCUIT BREAKER AND WIRING SIZE AS SHOWN.
(3) PROVIDE A NEW CIRCUIT BREAKER ARC -FAULT INTERRUPTER TYPE TO COMPLY WITH N.E.C. ART 210.12$
(4) SEE LOAD CALCULATION THIS DRAWING.
(5) PROVIDE NEW TAMDEM BREAKER SIZE AS SHOWK RELOCATE EXIST LOAD AND OR WIRE NEW LOAD AS SHOUT..
(6) ALL NEW CIRCUIT BREAKERS SHALL MATCH EXISTING PANEL TYPE MODEL AND MANUFACTURER
FEED WITH: EXISTING 303 THW CU IN 1 -1 /4 "G t0 REMAIN.
TYPE: SIEMENS LOAD CENTER
x,65 q
MODIFICATION: --
VOLTAGE 120/24OV, IPH, 3W
WV
PANEL
11511
ENCLOSURE: NEMA 3R, SURFACE
MAINS: 125 A M.L.O.
0
u
LOCATION: EXTERIOR CU AREA
A.I.C.S.: 10,000
(EXISTING TO REMAIN)
FED FROM: MAIN "B"-METER/F.P.L.
Co.
DESCRIPTION
WIRE AND
LOAD
POLE
CT.
A P
CT,
POLE
LOAD
WIRE AND
1T0NN
DESCRIPTION
CONDSIZE
(VA)
TRIP
No
No
TRIP
(VA)
CONDSIZE
W
CU -1
EXIST
3360
2
1
2
2
2184
EXIST
ul
Lu
CU-2
ti
r
cl
1
3360
50
3
4
0
2184
to
POOL PUMP
EXIST
1150
2
5
8
Ao
2100
EXIST
POOL EQ
t
0
1150
ZO
7
8
210 0
m
POOL LIGHTS
EXIST
3W /SF
145
9
1/20
1440
312,1/2"
NEW AC03 (DUCTLESS)
SPACE
--
--
}
!!
d12
I
--
--
SPACE
PHASE A: __ ----VA. PHASE
B: _N_VA
TOTAL: __- __VA_f3)
--- AMPS.
cI/ VtrarT AI t-ItLV tXItP IIMI G:I WIT'TO XF-MAIN. CONTRACTOR SHALL LABEL ALL CIRCUIT BREAKERS AT THIS PANEL
ACCORDINGLY TO THE LOAD SERVED, PROVIDE TYPEWRITTEN PANEL BOARD DIRECTORIES, NO HAND WRITTEN LABELS
(2) CIRCUIT UNDER THIS CONTRACT. PROVIDE NEW CIRCUIT BREAKER AND WIRING SIZE AS SHOWN.
(3) SEE LOAD CALCULATION THIS DRAWING.
(4) ALL NEW CIRCUIT BREAKERS SHALL MATCH EXISTING PANEL TYPE MODEL AND MANUFACTURER
(1)
�5xz)
(1)
(2)(4)
EXISTING
CORRIDOR
AREA
CFxISTING 303 THW CU EXISTING 303/0 THW CU IN 1-1/4"C TO REMAIN. f f N 2 "C TO REMAIN.
EXIST
f f 200A METER
If I f EXIST
f I
MAIN r r,�- I I
I I� �I IIM
�l� ZoF3
I�ExIS�I I�EXIS4I EXIST tI II li I
II R L II II PNL II t-rAIN ::�:: I I 12P/2O f -I
I I I "A1i II II a II 3 of 3 I'� T JJ LJ L
I�-�JI I - -__'" Q`�''� I
EXISTING 212 THW GU c _I
11Z(G) IN I/2 "C I EXISTING 303 THW GU �
I TO REMAIN IN I -1 /4 "G t0 REMAIN. NEW
104(6)
TO PUMP (EXIST) TO COLD WATER THW CU
METAL PIPE
FOR BONDING
l I
EXISTING 303/0 THW CU
IN 2 "C UG.
120/24OV, IPH, 3W ELECTRICAL
TO REMAIN
PROVIDE NEW 2 -5/8 DIAM x 10' -0" LONG
DRIVEN GROUND RODS, COPPER
RC5EfR DIAGRAM CLAD, SEPARATED 6' -0" To REMAIN.
N.T.S.
E-'
x,65 q
0
WV
0
u
t
Eae \r
�o
e.
W�
U
1T0NN
W
W
�
O
ul
Lu
r
ti
r
ye t. t1fr
x,65 q
0
0
t
Eae \r
e.
W 96
�jbtaz HE �
sY! oy
� F�ZQE
b y
S15
A i3UssimbiwX
DATEt 09/14/09
PROJ No: 9029
DWCs BYt JFB
CHECKED: JEB
REV$
SHEET TITLEt
ISSUED FORT
E -2
OF 2
0
0
t
ul
Lu
r
r
cl
1
z
to
zwa
•
t
0
m
r•
•
CL
1
W 96
�jbtaz HE �
sY! oy
� F�ZQE
b y
S15
A i3UssimbiwX
DATEt 09/14/09
PROJ No: 9029
DWCs BYt JFB
CHECKED: JEB
REV$
SHEET TITLEt
ISSUED FORT
E -2
OF 2