09-860-018AC -3 12A,12 SEE r NEW 120/2 OVERHANG LT WP 1 � � NOTES "A" I. FURIISHED ALL EXTERIOR LIGHT FIXTURES WEATHERPROOF TYPE. EXACT LOCATIONS SHALL BE VERIFY WITH ARCHITECT /OWNER REPRESENTATIVE. 2. VERIFY AT FIELD WITH ARCHITECT OWNER REPRESENTATIVE EXACT LOCATION OF LIGHT FIXTURES CONTROL SWITCHES AND WALL FIXTURES MOUNTING HEW BEFORE. ROUGHING -IN. 3. SMOKE DETECTOR SHALL BE OF THE I10V TYPE WITH BATTERY BAC241P AND INTERLOCK CONTACTS. DETECTOR SHALL BE CONNECTED TO AN UNSWITCHED LIGHT CIRCUIT SERVING KITCHEN OR BATHROOM. DETECTOR SHALL NOT BE WIRED ON THE LOAD SIDE OF ANY GFJ, CIRCUIT. ALL DETECTORS SHALL BE WIRED FOR SIMULTANEOUS ALA; "I. ALL SMOKE DETECTORS SHALL BE INSTALLED 3 FT MINIMUM FROM ANY AIR CONDITIONING CEILING OUTLET, COORDINATE WITH AC CONTRACTOR BEFORE ROUGHING -IN. REPLACE EXISTING DETECTORS TO MATCH NEW. 4. PROVIDE A GFI (GROUND FAULT INTERRUPTER) TYPE DUPLEX GROUNDED RECEPTACLES TO COMPLY WITH NE.C. ART 2108. 5. PROVIDE A AC UNIT DISCONNECT SWITCH TO COMPLY WITH NEZ, 440 VERIFY EXACT WIRING REQUIREMENTS AND PROTECTION SIZE TO EQUIPMENT WITH UNIT MANUFACTURER NAMEPLATE RECOMMENDATIONS BEFORE ROUGHING -K 6. PROVIDE NEED ARC -FAULT PROTECTION TO CIRCUITS SERVING BEDROOM AREAS AND ADJACENT BEDROOM AREAS (IE: WALKING CLOSETS, BED SEATING: AREAS, ETC) TO COMPLY WITH NE.C. ART 210128 REQUIREMENTS. 1. ALL LIGHTING FIXTURES COLOR FINISH SHALL BE SELECTED BY ARCHITECT OWNER REPRESENTATIVE BEFORE ORDERING, 8. EXISTING ELECTRICAL SERVICE GROUND RODS TO BE RELOCATED. CONTRACTOR SHALL PROVIDE NEW GROUND SERVICE, OUTSIDE NEW ADDITION VERIFY AT FIELD EXACT LOCATIONS. REFER TO RISER DIAGRAM. 8. EXISTING RECESSED OVERHANG LIGHTS. CONTRACTOR SHALL COORDINATE WITH ARCHITECT /OWNER REPRESENTATIVE REMOVAL OF SOME AND /OR ALL FIXTURES, CLEAN AND RE -LAMP EXISTING TO REMAIN WHEN APPLICABLE, 10. EXISTING KITCHEN EXHAUST FAN OUTLET. COORDINATE ANY REQUIRED RELOCATION WITH ARCHITECTOWNER REPRESENTATIVE BEFORE ROUGHING -TN, EXISTING RECEPTACLES AND OR INTERIOR/EXTERIOR ELECTRICAL DEVICES AT DEMOLITION AREAS SHALL BE RE -USED AS POSSIBLE AND /OR RELOCATED AS NECESSARY, VERIFY AT FIELD BEFORE ROUGHING -IN. Ey WU Fes-+ g �'A (,} C) a � 00 w � w d on • i i t t t • i • • t i tt i • t i t t W u F ILL! CY_ x4 C/) U. Q to _ 1-- W � � W F--i y�d�y F: r F c� — CAW is y F C9 F PATE: 09/14/09 PROJ NO: 9029 DUrx BY: JFB CI.IECKED: JEB REVS SHEET TITLE: ISSUED FORS E -1