Loading...
09-133-004, 1 7 0 z o� 0 u 0 0 C pi � C -C E �U O N U �u cn 0 �e r L V a� U V x � W � � O U V aZ C V O K [L U V V CQ U O C:) Z T T m C V d U U � J J U n L W o (] W N N —j G O o4) u M IU a o � I o s � �t a �- U � u rn M � 0 C u m E 010 C bw t� N c rn1 V U � V i u U 0 0 0 U ELECTRICAL NOTES 1: ALL WORK SHALL BE DONE IN ACCORDANCE WITH NEC AND SHALL COMPLY WITH ALL LOCAL RULES AND ORDINANCES. 2: MINIMUM WIRE SIZE SHALL RE 14 AWG, EXCLUDING CONTROL WIRING UNLESS OTHERWISE NOTED, ALL CONDUCTORS SHALL BE COPPER WITH THHN OR THWN INSULATION. NONMETALIC SHEATHED CABLE (ROMEX) IS ACCEPTABLE 3: OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS. CAST ALLOY WITH THREADED HUNS IN WET OR DAMP LOCATIONS AND SPECIAL ENCLOSURES FOR OTHER CLASSIFIED AREAS. 4: DISCONNECT SWITCHES SHALL BE H.P. RATED HEAVY —DUTY QUICK —MAKE, QUICK —BREAK ENCLOSURES AS REQUIRED BY EXPOSURE. 5: IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTS NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORK ORDER. is ELECTRICAL SYSTEM SHALL BE COMPLETE AND EFFECIVELY GROUNDED AS REQUIRED ■Y THE LATEST EDITION OF THE N.E.C. 7: ALL MATERIALS SHALL BE NEW AND BEAR UNDERWRITERS LABLES, WHERE APPLICABLE. is ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL WE FULLY OPERATIVE AND ACCEPTED DY ENGINEER/DESIGNER !: ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. 10: CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN ONE YEAR FROM THE DATE OF ACCEPTANCE. 11: CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGE THEREBY. 12: ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST LIABILITY OF PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 13: CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS, AND TESTING. 14. ELETRICAL CONTRACTOR SHALL VERIFY ALL LOADS AND REPORT ANY DISCREPANCY TO ENGINEER LOAD TABULATION: PNL "A" – 116 A 2 -1/2" C DOUBLE LUGS ELECTRICAL LEGEND BRANCH CIRCUITS RECESSED DOWN LIGHT WIRE & CONDUIT WALL MOUNTED FIXTURE S SWTCH Sa 3WAY SWTCH TOTAL VA DISCONNECT LOCATION DUPLEX RECEPTACLE C(1VrRrn TrRRnC(" DUPLEX RECEPTACLE MTD 0 42" AFF M1 ? -1/ ?" C SPECIAL PURPOSE RECEPTACLE 1 JUNCTION BOX CZM ELECTRICAL PANEL WID WEATHER PROOF s)TI SMOKE DETLCTOR (PHOTOELECTRIC TYPE) (22,000 A.I.C.) 1 -5/8" COPPERCLADI GROUND ROD 10 FT. LONG - EXISTING ELECTRICAL RISER DIAGRAM N.T.S. 3 #1 /0 THWN 1 #6 G D. (CU) – 2 "C `141 /0 1 JiR, rRF) THWN ((.1 J) 9 "f BUILDING STEEL FOUNDATION CWP (METAL) cIx) (a) (a) (EXISTING) 150 M.L.O. SERVICE: 1 PH, 3W- 120/240V , , PANES A SURFACE MOUNTED BRANCH CIRCUITS LOCATION WIRE & CONDUIT TOTAL BREAKER TRIP KT. No. CKT. No. BREAKER TRIP TOTAL VA WIRE do CONDUIT LOCATION VA C(1VrRrn TrRRnC(" k14 -1 1P" M1 ? -1/ ?" C 600 1 r 1P-PO 1000 81P -1 /P "C Fx1CTTNr I PAD MAM RFDRnnM n, nPFNFR 600 3 4 600 5 MAI D1 R I)RI11 IM 2H 40 (2000) (2000) 24E3 -3/4' U CU NUi_' STATRS 5 6 11' -lU / 8 F JUN I AIN x STUDY 9 10 2P 30 ?750 P750 3N10 -1 /P ' C If U * 11 1 P BAIH LIU /SU 1 9 10 PP 30 2UoU i'UUU 1000 DRYLK' S I UUY Y, 15 16 11 1P 1100 1/ LN I:Y LP 20 1UoU 1000 1112 -1/2' C POOL PUMP 3 13 14 x 15UU 19 20 U1N1NG /CURB x P1 15 1620 1 JON W.H Nn. 1 M, BATH I TG. KTTCIIFN /T31(F, P9 ?4 M. BA I I I L I L. 11 18 f AM1LY kULIM 25 26 1P -2U x 19 20 M. BCD LTG 9000 3000 x AM1LY RUUM 21 213 11' -20 x BATI I RFCFI'TACI F STTTTNn RnnM CnRPTDPR x 29 3U P3 P4 PP 60 VUUU �UUO WHTRI Pnnl SITTING RMM BA I I I RILL 1112 -1 /2 "L 31 1P -2U 25 26 LAUNDRY IUUU M, Tarn 1 21 213 211 40 (P100) ( ?100) 3 34 1P -PO PrrrinrRATPR ikl ? -1 / ?" C 1500 M. RI­ 1) 29 30 IiVTNG RM M14 -1 / ?" C x 1P -15 31 3? 1P -P0 900 NLW LNIRY LIS. 4 ODUR SPAPF I TVTNFr RM 11' -2U 3/ 38 33 34 SPACE SRARr 900 CABANA BAIH 40 35 36 900 STALL 3/ is 6600 SPACL SURTnTA1 39 4U 34P00 S1,17TAI 41 4P E X 320Q S.F, 9600 1 S111ITTAI iP600 TnTAI = ' 47600 35000 SIIBTITAI (a) (a) (a) fees ••• • • ••Pre E +W 1. • r Y n r4SW • i • • r • ♦ • • w C: w•• • W W w r (EXISTING) 150 M.L.O. SERMI,C6:W-120 /240V , ••fee PANEL B SURFACE MOUNT .D•• r • BRANCH CIRCUITS LOCATION WIRE do CONDUIT TOTAAL BREAKER TRIP oT' KT BREAKER TRIP TOTAAL WIRE & CONDUIT LOCATION Submittal: - -- WASIIFR M1 ? -1/ ?" C 600 1P - ?0 i P PP 60 0500 55UU P84 -11C AHII Nn. P (10 KW) n, nPFNFR 600 3 4 600 5 6 2H 40 (2000) (2000) 24E3 -3/4' U CU NUi_' STATRS x 11' -lU / 8 F JUN I AIN x 9 10 2P 30 ?750 P750 3N10 -1 /P ' C WI I. Nn, P BLU NU. 1 * 11 1 P 1 13 14 PP 30 2UoU i'UUU 3 k1U -1/2' U W /W:D. DRYLK' Y, 15 16 P x 1/ lu LP 20 1UoU 1000 1112 -1/2' C POOL PUMP 3 x 19 20 3 x P1 PP PP P750 31110 -1 /?" C W.H Nn. 1 M, BATH I TG. P9 ?4 M. BA I I I L I L. * 25 26 1P -2U x 412 -112' C BATI I RCCEPTACLC M. BCD LTG x 21 213 11' -20 x BATI I RFCFI'TACI F STTTTNn RnnM x 29 3U if' -20 1600 WHTRI Pnnl SITTING RMM x 31 IPI 1P -PO 600 1'11111 1 I(,HI M, Tarn 3 34 1P -PO 1500 ikl ? -1 / ?" C NLW ENIRY NAIL M. RI­ 1) * 3b 36 1P -PO 100(1 It1 ? -1 /P' C NEW EN RY GA I L NLW LNIRY LIS. 4 ODUR 1112 -1 /2 "C 900 11' -2U 3/ 38 SPACE SRARr 900 39 40 900 1900 S.F. 6600 SURTnTA1 11100 TI TAI = 45300 34P00 S1,17TAI (a) nFCT /C /11 nrw I nAD = 36,6 KW (a) AFCT /C /R DFMAND I PAD = 33,3 KW A/C 9 100% = 4POU FIP.ST 10 KW R 100 7 - 10.0 KW (b) nN TTMFR A/C to 1007 = 4POO FTRST 10 KW P 100 7. HEA I L 65% _ IIN 26.6 KW � 40% - 10.64 KW ��) (,F 1 HEA I L 65% _ /150 23.J KW k 40% A/C = 7.15 KW A/C (7.15) 2/./9 KW (116 A) PROPOSED ELECTRICAL PLAN SCALE: 114 " = 1' 0" dU door hell exist. A/C compressors to remain 10.0 KW 9.32 KW 7.15 KW 26.4/ KW (ill A) GATE MOTOR CONTROL UNIT COORDINATE EXACT VOLTAGE AND ELECTRICAL REQUIREMENTS WITH CHOP nPA1A /I1\1(:C w•r wie,s j r u v u r ••• r Wes* (b) Cc ) (r) S) I L 2 L DESIGN L06000029727 Principal Esteban R. Latorre" No. 92212 11401 S.W. 109 COURT MIAMI, FLORIDA 33176 305 . 979. 9725 Seal �k ' ~ ��Fi1• ?�fa Y __ W V V 1 L � m V1 00 0 W p O Scale: VARIES Date: 1 -19 -09 Project Designer: EL Drawn By: EL Checked By: EL Job Number: 100 Submittal: - -- File: - -- Revisions No. Description Date: Sheet Number Ee IL