10-558R-0223/4" CW + UUMIERSIRK + 1-MIN.1 -7 SAME SIZE AS SEWER MAXIMUM SIZE 4 "----•- O i i A HEAT TRAP (TYP.) d BALL VALVE (TYP.) T 117 UNION /— FINISHED GRADE l i TURN LEAD FLASHING DOWN INTO STACK 2" MIN. 4 LB. SHEET LEAD FLASHING FILL IN W/ ROOF MATERIAL ROOFING ROOFING CONSTRUCTION VENT STACK NOTE: ANY VENT PIPE WITHIN 10` OF ANY DOOR , WINDOW , OR EXHAUST OPENING OR OUTSIDE AIR INTAKE SHALL EXTEND NOT LESS THAN 3' ABOVE SAME . VENT -THRU -ROOF DETAIL NO SCALE POSITION PIPE TO AVOID OBSTRUCTIONS TO CLEAN -OUTS. + r• r r .� FACE OF WALL WALL CLEANOUT DETAIL m ABSORTION TYPE No. 75001 :0+ 75002 rr 1 75003 i 75004 �i -1 005 5006 P.D.I. SYMBOLS VENT COLD WATER WC WATER CLOSET 30 (x} CLASSFICATIONS ESTABLISHED BY THE PLUMBING AND DRAINAGE INSTITUTE "STANDARD P.D.I. - 02O1" SHOCK ABSORBER SCHEDULE NO SCALE NOTES: 1. CONTRACTOR TO INSTALL SHOCK ABSORBER AS PER MANUFACTURER INSTRUCTIONS. 2. SHOCK ABSORBERS TO BE JOSAM (ABSORBOTRON) OR EQUAL 3. CONTRACTOR TO INSTALL SHOCK ABSORBERS WHERE QUICK CLOSING VALVES ARE PRESENT. 28 LF OF 1/2" (100,000 BTUH) (PRIMARY SVC.) _>� 18 LF OF 1/2- (299,900 BTUH) (PRIMARY SVC.). %" STUB FOR BBQ (100,000 BTUH @ 11 "WG) SECOND STAGE REGULATOR c l of SECOND STAGE REGULATOR --� D� °80 LF OF 1 /2" (199,900 BTUH) (PRIMARY SVC.) 20 LF OF 1 /2" (389,000 BTUH) (PRIMARY SVC.) .:. • r r : GAS PIPE SIZING 1. PRIMARY SERVICE (175 LF FROM PRIMARY' O. TABLE TO SECOND STAGE REGULATOR) OF 2,193,900 BTUH TOTAL, SIZED PER • PRESSURE 2. LOW FROM REGULATOR TO REMOTE • - +r : TOTAL, SIZED PER TABLE 402.4(26) OF FBC - FUEL GAS. A i _ _61 ETC FAX FIXTURE CONNECTI ❑N SCHEDULE MARK DESCRIPTION WASTE VENT COLD WATER WC WATER CLOSET 3" 2" 3/4• LV LAVATORY 1 1/4- 1 1/4- 1/2" BIDET BIDET 11/4" 11/4- 1/2' SH SHOWER 2" 1 1/4- 1/2" TUB TUB 2" 11/4- 1/20 KS KITCHEN SINK 1 1/2" 1 1/4- 1/2" L LAUNDRY SINK 1 1/2" 1 1/4" 1/2- ME 1/2" 1/2' 1/2" 1/20 1/2" 1/2" li_'_ • III AEMARKS 11 PROVIDE ANTI /SCALD MIXING VALVE PROVIDE ANTI /SCALD MIXING VALVE MARK STORAGE IN MANUFACTURER U.S. GAL INPUT MODEL No. REMARKS LOCATION IWH -1 __ NQRITZ 199,900 BTUH NC199 -OD 23.6 -(H) X 13.8 -(W) SEE PLANS IWH -2 __ NORITZ 180,000 BTUH NR71 -OD 23.6 "(H) X 13.8 "(W) SEE PLANS r) ' " MANUAL SHUT -OFF VALVE IN WALL RECESS '--- CONNECT TO RANGE (209,000 BTUH ® 11 "WG) IWH -2 L-- 3/4 "G. CONNECT TO IM-2 (180,000 BTUH 0 11 "WG) ` 1 -1 /2 "G CONNECTION TO GENERATOR � U DRIP LEG TYP. ,/GRPO� SECOND STAGE REGULATOR (PRIMARY SVC.) i LF i (2,1925, goo BTU (PRIMARY SVC.)-m `-- SECOND STAGE REGULATOR PRIMARY REGULATOR MANUAL SHUT -OFF VALVE (TYP.) 6 A S �a.0 1�20� c �a. To 77",It Oc t�i�tvi�tJy 1000 GAL EACH LPG TANK BY AMERIGAS. FASTEN TO CONC. �'�`'l PAD PER ASCE 7 -98. kj P, 1 ® 1 P RESIDENC&I 81 STRE Ak- iOUTH MIAMI, &l 01-10 =I ERNESTO ALOMA P.E. 53623 MANUEL P. MONTOYA P.E. 66220 HECTOR J. CASTILLO P.E. 65405 ALBERTO M. MALATS P.E. 70692 tt "11iatiasrar MECHANICAL,•. NG5 >� ..mo�tL . • � . r JOSE -t WfAgTiNEZ J' . P.E.43$79 0 RO®RIGWi. °ME SS„ P:E g0�6 F�• �,,,.� ®� ®gym: } CtONWLTING ENGIF 135 ALMERIA AVENUE CORAL GABLES, FLORIDA 33134 (305) 446 -2788 (PHONE) (305) 443 -5944 (FAX) EB- 00003791 www.sdmcorp.com