12-868-012PLUM5ING GENERAL NOTES AND SPECIFICATIONS:
1. A. SCOPE OF WORK:
THE WORK SHALL INCLUDE ALL PLUMBING NECESSARY SHOWN ON THE
DRAWINGS, SPECIFIED HEREIN AND /OR AS NEEDED FOR A COMPLETE
SYSTEM, INCLUDING BUT NOT NECESSARILY LIMITED TO:
1_ DOMESTIC COLD AND HOT WATER PIPING SYSTEMS
2. SANITARY DRAIN AND VENT SYSTEMS
3. PLUMBING FIXTURES AND TRIM
4. AIR CONDITIONING CONDENSATE DRAINS
5. PRESSURE AND TEMPERATURE RELIEF FROM WATER HEATER
6. PIPING INSULATION
1. SUPPORTS AND HANGERS
B. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST
EDITION OF THE "FLORIDA BUILDING CODE 2010" AND LOCAL ORDINANCES
AND IN COMPLIANCE WITH THE 'FLORIDA ENERGY EFFICIENCY CODE FOR
BUILDING CONSTRUCTION', AND 'HRS' REGULATIONS. IN THE EVENT OF
CONFLICT BETWEEN ANY CODE OR REGULATIONS, THE MORE STRINGENT
REQUIREMENTS WILL GOVERN.
2. CONTRACTOR TO VERIFY AT SITE THE LOCATION, ELEVATION AND SIZE OF ALL HE
EXISTING LINES FOR CONNECTION BEFORE INSTALLATION OF ANY PIPING.
3. UNDERGROUND METAL PIPING SHALL BE PROTECTED WITH A COAT OF BITUMINOUS
COMPOUND BEFORE COVERING
4. ALL FIXTURES SHALL BE PROTECTED AGAINST WATER HAMMER WITH AIR CHAMBERS
OR SHOCK ABSORBERS (ARRESTORS) . WASHING MACHINE SHALL HAVE WATER
HAMMER ARRESTOR FOR BOTH CW t HW.
5. ALL FLOOR DRAINS TO HAVE TRAP PRIMERS 1/2' LINE FROM THE NEAREST
PLUMBING FIXTURE.
6. PLUMBING FIXTURES SHALL BE CONSTRUCTED WITH THE APPROVED MATERIALS,
SHALL HAVE SMOOTH IMPERVIOUS SURFACES AND SHALL BE FREE FROM DEFECTS
AND CONCEALED FOULING SURFACES. ALL FIXTURE TRIM TO BE CHROME PLATED.
FIXTURES SHALL BE PROVIDED WITH SUPPORTS, HANGERS, ETC.
-l. UNDERGROUND WASTE LINES 3' AND ABOVE TO BE PVC SCH. 40 AND SLOPE a 1 /87 FT.
WASTE LINES 2' AND UNDER, AND ABOVE GROUND PIPES SLOPE 0 1 /4'/FT.
8. PROVIDE FULLY ACCESSIBLE CLEAN OUTS ON SANITARY AND ANY WASTE PIPING AT
EVERY CHANGE OF DIRECTION, AND AT BOTTOM OF STACKS. CLEAN OUT LOCATIONS
AND SIZES ON HORIZONTAL LINES SHALL BE ACCORDING TO CODE.
S. VENT LINES TO EXTEND S' MIN. ABOVE ROOF AND FLASH WITH LEAD.
10. WATER PIPE BELOW GROUND SHALL BE COPPER TYPE 'K' ABOVE GROUND TO BE
COPPER TYPE 'L'. OR APPROVED CPVC . NO JOINTS ALLOWED UNDERGROUND.
11. PIPING
A. SUPPORT ALL PIPE FROM SOUND PORTIONS OF STRUCTURE AND AT PROPER
INTERVALS ACCORDING WITH CODE.
B. PROVIDE SLEEVES FOR ALL PIPING PASSING THROUGH FOUNDATION SLABS OR
MASONRY WALLS, CAULK OPENINGS BETWEEN PIPE AND SLEEVES.
C. WHERE EXPOSED PIPES PASS THROUGH FLOORS, WALLS, OR CEILINGS, PROVIDE
ESCUTCHEONS FIRMLY SECURED TO THE PIPES AND OF SUFFICIENT OUTSIDE
DIAMETER TO COVER THE SLEEVED OPENINGS FOR THE PIPES. PROVIDE
CHROMIUM PLATED ESCUTCHEONS IN BATHROOMS.
12. INSPECTIONS AND TESTS
A. CONTRACTOR SHALL BE RESPONSIBLE TO ASK FOR INSPECTIONS TO THE
AUTHORITIES HAVING JURISDICTION, AS THE WORK PROGRESSES. ALL
SYSTEMS SHALL BE TESTED BY CODE AND /OR LOCAL REGULATIONS.
B. DRAINAGE PIPING: BEFORE INSTALLATION OF ANY DRAINS, THE ENDS OF
SYSTEMS SHALL BE CAPPED AND ALL LINES FILLED WITH THE WATER TO THE
HIGHEST POINT AND ALLOWED TO STAND UNTIL INSPECTION 15 MADE BY AN
OWNER REPRESENTATIVE.
13. STERILIZE ALL WATER LINES WITH A MIXTURE OF TWO (2) POUNDS OF CHLORINATED
LIME TO EACH 1000 GALLONS OF WATER (50 PPM OF AVAILABLE CHLORINE).
RETAIN MIXTURE IN PIPES 24 HOURS AND FLUSH THOROUGHLY WITH POTABLE WATER
BEFORE PLACING IN SERVICE.
14. COMPLETE SYSTEM, FIXTURES AND EQUIPMENT SHALL BE GIVEN AN IN- SERVICE TEST
AFTER COMPLETION OF THE INSTALLATION.
15. FIXTURES AND FAUCET SHALL COMPLIANCE WITH MAXIMUM WATER CONSUMPTION
RATES AS PER MIAMI DADE AMENDMENTS TO F.B.G. PLB. 604.4. REFER TO MIAMI
DADE ORDINANCE 08 -14.
16. FIXTURES SHALL COMPLIANCE WITH REFERENCED STANDARDS AS PER F.B.C. PLB. 406
THROUGH 421 AND FB.C. RESIDENTIAL P2101.
CAP FOR FUTURE
CONNECTION SOLAR
OR HEAT RECOVERY
GATE VALVE —�
HEAT TRAP
N-W. TO FIXTURES
DRAIN VALVE
EMERG. DRAIN PAN
WALL BRACKET—`
HEAT TRAP
GATE VALVE
COLD WATER, 3/4'
UNION
J
PRESSURE i TEMPERATURE
RELIEF VALVE (ASME APPRVD.)
I' DP.
---TYP. 1' AIR
GAP
WATER PE,ATER PIPING DIAGRAM
NO SCALE
3/4' Cu RELIEF DISCHARGE
LINE, TO OUTSIDE GREEN
AREA, TERMINATE 6'
ABOVE FIN. GRADE
PLUMBING FIXTURE SCHEDULE
MARK
TRAP
SIZE
FIXTUFI
UNITS
HOT
WATER
GOLD
WATER
WC
3'
3
-
1/2'
LAY
11/2'
1
1/2'
1/2'
SH
2'
2
1/2'
1/2'
SK
11/21
2
1/2'
WM
2'
2
'/2 •
iii
DID
1' SW
N/A
1/2'
-
HB
-
_
_
1 /2' W/VALVE E
VAC. BREAKER
TUB
U.G.
An.
2
1/21
BD
2'
Ups.
11/2'
AG.
2
'/2 •
��2'
1) FIXTURES TO COMPLY W/FBC 2010 Plumbing Sections
'/09.1,603.1 t 111
2) ANTI -SCALD VALVE:
ALL SHOWERS t BATH /SHOWER COMBINATIONS SHALL
BE PROTECTED WITH A CONTROL VALVE OF THE
PRESSURE BALANCE, THEFZ- 10STSTIC MIXING OR COM-
BINATION TYPE SET. HANDLE POSITION STOPS PER
MANUFACTURERS INSTRUCTIONS AT TIME OF INSTALLATION
TO A MAXIMUM MIXED WATER OUTLET TEMPERATURE OF 120' F.
BONN
P/ '
I F
SG,ALF: 114 " =1' -m'
GENERAL NOTES:
THE COMPLETE SET OF CONSTRUCTION DOCUMENTS CONSISTS OF
DRAWINGS, DETAILS i SPECIFICATIONS. IN THE EVENT OF A DISCREPANCY, THE
GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT AND /OR ENGINEERS
FOR CLARIFICATION. ANY DEVIATION FROM THESE DRAWINGS, WITHOUT THE
WRITTEN AUTHORIZATION OF THE ARCHITECT AND /OR ENGINEERS IS
PROHIBITED. GENERAL CONTRACTOR OR SUBCONTRACTORS ASSUMES FULL
RESPONSIBILITY FOR ANY UNAUTHORIZED DEVIATION FROM THE INFORMATION
DEPICTED IN THE CONSTRUCTION DOCUMENTS.
ENGINEERS ARE NOT RESPONSIBLE OR LIABLE FOR ANY DISCREPANCY
BETWEEN THESE DRAWINGS AND THE EXISTING CONDITIONS. ANY WORK
PERFORM ON THE PROPERTY PRIOR THESE CONSTRUCTION DOCUMENTS AND
WILL NOT MATCH WITH THE INFORMATION IN THE EXISTING CONSTRUCTION
DOCUMENTS ON CITY RECORDS OR IT WAS NOT VISIBLE AT TIME OF
INSPECTION OR THE WORK WAS DONE ILLEGALLY WITHOUT PERMIT BY OTHERS
AND WILL CAUSE A DISCREPANCY WITH THE NEW DRAWINGS IS THE
RESPONSIBILITY OF THE CURRENT OWNER OF THE PROPERTY AT HIS OWN
EXPENSE TO PERFORM ALL THE NECESSARY CORRECTIONS IN ORDER THAT
ALL WORK IS IN ACCORDANCE WITH THE CURRENT FLORIDA BUILDING CODE
AND THE LOCAL ORDNANCE AND WILL MATCH WITH THE NEW CONSTRUCTION
DOCUMENTS FOR WHICH WORK WILL BE PERFORM.