Loading...
14-177-011i 1 /2.OSCHD. 40 BLACK TO FUSIBLE UNKS AND REMOTE PULL STATION IRON SUPPLY LINE TO XV CONTROL BOX IN CABINET H USE CORNER PULLEYS AT ALL I�CHANGE OF DIRECTIONS TO GAS VALVE VENT PLUG FOR SPECIFIC APPLICATION 1/4' OD COPPER TUBE wanes sulaew + *gym I PULL STATION I I I I WNDR600 IS Fbw Points DUAL WHDR400 24 Flow Paints (monifolded) 1 I I 1 I I 1 1 I I XV 28' x 28' 20' min /42' mm WHDR -400 CYLINDER 1 CONTROL BOX CONTROL ®' Rodent IMOreroiYr 24' X 21' 24' -- /b' ma. FIRE CABINET 1 HOOD k LIGHT SWITCH 0 @ © 0 FIRE SUPPRESSION ELEVATION VIEW SCALE: 1/2” - V -0" CONTROL PANEL k DOUBLE MICROSWTCH PROVIDED BY HOOD OFPOT. CONTROL PANEL PRE -WIRED TO LIGHT SWITCH, HOOD SWITCH, AND 1 POLE OF FIRE SYSTEM MICROSWrrCH. THE CONTROL PANEL IS PRE -WIRED TO SHUTDOWN MW AND TURN ON EXHAUST IN CASE OF FIRE ALL OTHER CONNECTIONS ARE TO BE MADE BY OTHERS. THERE IS (1) NO /NC MICROSWTTCH AVAILABLE IN THE J -BOX FOR FIRE ALARM ACTIVATION FOR OTHER REQUIREMENTS SUCH AS THE SHUTDOWN OF ELECTRIC APPLIANCES AND RECEPTACLES UNDER HOOD, GAS SOLENOID ACTIVATION, AND ANY OTHER REQUIREMENTS BY NATIONAL, STATE, OR LOCAL AUTHORITIES HAVING JURISICTION USE TERMINALS NC AND NO AS REQUIRED. NC /NO HAVE 115V /IPHASE AND ARE ACTIVATED UPON FIRE SYSTEM ACTUATION NOTE' IF THERE IS NO BUILDING ALARM R MAY BE REQUIRED TO PROVIDE A HORN TO BE SOUNDED UPON FIRE SYSTEM ACTUATION. CONTACT YOUR MUNICIPALM FOR THEIR REQUIREMENTS. FIRE CABINET /FIRE SYSTEM DETAILS KIDDE NOZZLE DETAIL RING PATTERN t I DIM ADP F GRW R LPF LPR 0 1 2 3 4 1&4 0 RINGS RING RINGS RINGS RINGS RINGS RINCS W/ DISC k CORE DUCT TEMPERATURE SENSOR DETAIL DUCT TEMPERATURE SENSOR TEMPERATURE SENSOR TO BE PLACED IN THE GREASE EXHAUST DUCT TO ACTIVATE THE EXHAUST HOOD SYSTEM PER FLORIDA MECHANICAL CODE 5072.1.1 OPERATION. WHICH STATES TYPE I HOOD SYSTEMS SHALL BE DESIGNED AND INSTALLED TO AUTOMATICALLY ACTIVATE THE EXHAUST FAN WHENEVER COOKING OPERATIONS OCCUR THE ACTIVATION OF THE EXHAUST FAN SHALL OCCUR THROUGH AN INTERLOCK WITH THE COOKING APPLIANCES. BY MEANS OF HEAT SENSORS OR BY MEANS OF OTHER APPROVED METHODS lloo som mnao'�,eln �IPrk w w M olrol omx Iwn EEL GAS VAL LOCATE AND KIDDE WHDR SCHEDULE NOZZLE APPLICATION COVERAGE Fin xo�ac P I NuAPK vv NOZZLE APPLICATION COVERAGE "m`.:°>T P'DW No 1 FP App Plenum 10' x 4' N/A Y Bank a Sln le 1 1 1 1/16" S/S CABLE IN 1/2" EMT 1 - TO XV CONTROL BOX IN CABINET H USE CORNER PULLEYS AT ALL I�CHANGE OF DIRECTIONS TEE PLAN VIEW 1 FOR SPECIFIC APPLICATION LOCATION OF wanes sulaew + *gym I PULL STATION I I I I WNDR600 IS Fbw Points DUAL WHDR400 24 Flow Paints (monifolded) 1 I I 1 I I 1 1 I I GAS VAL LOCATE AND KIDDE WHDR SCHEDULE NOZZLE APPLICATION COVERAGE Fin xo�ac P I NuAPK vv NOZZLE APPLICATION COVERAGE "m`.:°>T P'DW No 1 FP App Plenum 10' x 4' N/A Y Bank a Sln le 1 1 1 KIDDE PARTS LEGEND TOTAL FLOW PINTS 8 MFG: KIDDE - FENWALL GENERAL NOTES MAXIMUM FLOW POINTS: F 1 NOZZLE APPLICATION COVERAGE wanes sulaew + *gym I aMD:° WNDR600 IS Fbw Points DUAL WHDR400 24 Flow Paints (monifolded) No FP. R Rones 28' x 28' 20' min /42' mm e' ,^!'+ ken iNeptlM 1 2 2 ®' Rodent IMOreroiYr 24' X 21' 24' -- /b' ma. 46 ayes b w ew— 1 1 1 GRIN (cae) 1© K TYPE EXTINGUISHER (BY OWNER) App Griddle -M S.,t— 42' . 30' 13' mn /4a' mo. F Simla Vat Fryer 18' X Is' 27- min /45' max N ayee m to d"— 2 1 2 (we=I ms) KIDDE PARTS LEGEND TOTAL FLOW PINTS 8 MFG: KIDDE - FENWALL GENERAL NOTES MAXIMUM FLOW POINTS: For P'pinG allowances and balan... re/er to KIDDE -FE Technical WHDR125. 4 Flow Pointe UL300 X3559 Manual -U.L File IX3559. AN DR260: 8 Flow Point The System installation shall form WHDR260: 12 Flow Pointe to the repuinemente of NFPA /17A & 06 WNDR600 IS Fbw Points DUAL WHDR400 24 Flow Paints (monifolded) and all applicable Stale and Local Codes. KIDDE PARTS LEGEND SYMBOL DESCRIPTION KIDDE P/N 0112" APPLIANCE NOZZLE GRIN. R. F. ADP, OM, LPF. LPR L PLENUM NOZZLE ADP NONE 501N PERIMETER APP NONE DUCT NOZZLE CONTROL BOX = XV a , 1001N PERIMETER (2) ADP Y DUCT NOZZLE 360' FUSIBLE LINK 8O 450' FUSIBLE LINK ®' REMOTE PULL STATION 87- 120050 -001 F-I 10 .7S', 1 -, 1.25', 1.5', lOL01�. GAS VALVE 2', 2.5', 3'. FIRE SYSTEM DESIGN SCHEDULE FIRE SYSTEM COMPONENTS MANUFACTURER - KIDDE FIRE SYSTEMS LAYOUT 1O TANK #1 - WHDR -400 SUPPLY LINE FOR TANK #1 0112" O2 TANK #2 = NONE SUPPLY LINE FOR TANK #2 NONE O TANK #3 = NONE SUPPLY LINE FOR TANK #3 NONE ® TANK #4 = NONE SUPPLY LINE FOR TANK #4 NONE O5 CONTROL BOX = XV © © MECHANICAL PULL STATION 18 "x24" O7 360' FUSIBLE LINK 8O 450' FUSIBLE LINK 16 "x24" 9O GAS VALVE = MECHANICAL 10 ADP NOZZLE 11 R NOZZLE 12 F NOZZLE 13 GRW NOZZLE 14 LPR NOZZLE 15 DM NOZZLE 16 LPF NOZZLE 1© K TYPE EXTINGUISHER (BY OWNER) HOOD #1 SIZE = 9' -0 "x48" HOOD #1 EXHAUST DUCT SIZE = 10 "06" APPLIANCE LAYOUT RENSIONS DESCRIPTION LANE HOOD DEPOT INT'L INC 710 S POWERLINE RD #H DEERFlELD BEACH, FL APPLIANCE TYPE OVERALL SIZE COOKING SURFACE OA 6 BURNER RANGE 36 "x28' 36 "x24" OB RADIANT CHARBROILER 24 "x24" 21 "x21" © FLAT TOP GRIDDLE 18 "x28" 18 "x24" 0 FRYER 16 "x24" 15 "04' GENERAL FIRE SYSTEM NOTES 1. NO GALVANIZED PIPE TO BE USED ONLY USE SCHEDULE 40 BLACK IRON STEEL PER NFPA #17A 2 SYSTEM TO HAVE AUDIBLE/VISUAL DEVICE TO SOUND UPON ACTUATION OF FIRE SUPPRESSION SYSTEM. (INSTALLED AND PROVIDED BY ELECTRICIAN) 3. ALL HOOD PENETRATIONS TO BE WELDED LIQUID TIGHT OR SHALL USE A UL LISTED SEAL PER NFPA II7A 4. ALL MOTORS, LIGHTS AND OTHER ELECTRICAL DEVICES INSTALLED IN TYPE 1 DUCTS OR HOODS OR LOCATED IN THE PATH OF TRAVEL OF EXHAUST PRODUCTS ARE SPECIFICALLY APPROVED FOR SUCH USE 5. FIXED PIPE EXTINGUISHING SYSTEMS IN A SINGLE HAZARD AREA SHALL BE ARRANGED FOR SIMULTANEOUS AUTOMATIC OPERATION UPON ACTIVATION OF ANY ONE OF THE SYSTEM COMMON EXHAUST DUCT FOR MORE THAN ONE HOOD WOULD DEFINE A SINGLE HAZARD AREA EXCEPTION WOULD BE A SECONDARY FIRE SUPPRESSION SYSTEM CONTAINED IN THE COMMON EXHAUST. 6. THE FIRE SUPPRESSION SYSTEM SHALL BE INSTALLED BY SEPARATE CONTRACTOR. HOOD AND FANS OPERATIONS NOTES FIRE MODE REQUIRES EXHAUST FAN CONTINUES TO OPERATE AND SUPPLY FAN STOPS. SUPPLY AND EXHAUST FANS ARE INTERLOCKED WITH PILOT LIGHTED SWITCH IN KITCHEN AREA. HOOD EXHAUST FANS SHALL OPERATE WHENEVER THE FIRE EXTINGUISHING SYSTEM IS ACTIVATED (a- VEN,WHFN HOOD SWITCH IS IN OFF POSTION)- ALL ELECTRIC AND FUEL TO ALL ^ EQUIPMENT AND RECEPTACLES UNDER HOOD TO SHUT DOWN ^UPON FIRE SYSTEAA ^ ACTIVATION .. - SYSTEM TO HAVE REMDTE ^PJLL-STATION FOR MANUAL MEANS GF ACTUITON AND ^ - FUSIBLE LINKS FOR AUTOMATIC MEANS 0: ^ ^ ^ ACTUATION PER NFPA 17A ` „ix 8 At% y ^GENE S� i -- 0 �f N0. x2500 =01. STALE OF NAL I O O 710 SOUTH POWERLINE ROAD CHIEF ENGINEER DEERFlELD BEACH, FL. 33442 MAX BRAND, P.E. X,kr, E -MAIL: HOODDEPOTOAOLCOM PHIS 800 - 322 -8730 Awa, LICENSE / 72500 'UMBER RENSIONS DESCRIPTION LANE HOOD DEPOT INT'L INC 710 S POWERLINE RD #H DEERFlELD BEACH, FL C E V I C H E 5900 SW 73RD STREET MIAMI, FL 33143 IN -3208 SCALE. NOTED I DRAWN er� M.C. Gr+Ear BY: R.Z. LATE 11/15/13 FIRE SUPPRESSION SYSTEM 1 DI= 2