t YM% MUZYWMA WI)M1 Pow Plmd.S 8(27(2004 2:33:01 PM, WDeP70d 1650[
Y4'° AE —CD FIDE TO
OUTSIDE BLDG. TERMINATE
6" ABOVE GRADE & 1 ® -0"
OFF WALL--\
♦ • , • • •
2" X2 " XI /5
STEEL. ANGLE
M
r X r X 1/4" 5TEE
O fR OF
1/2" THfRU E30LT OIR THREADED
GOfRD OF J016T
r * r
METAL 5AND 1-1/2"
0 GA TYF=' ARROUND
• ! UNIT AS SHOW
TIE DOWN C:UFS
it r )r # �•
I a
STEEL ANGLE
r— \,' 5 ps: i ,TI ii
NolfiPA
-0— COATS
•- -• •
AND FIN15H W11 GOAT OF r
f=AINT
COND. UNIT SUPPURT DETAIL n.tm .
AIR Cu"NDITIONING GENERAL NOTE
GENERAL
PROVIDE DOUBLE THICKNESS TURNING VANES AT ALL
35,000
SQUARE ELBOWS. WHERE THE ELBOWS ARE RECTANGULAR
PROVIDE ( FURNISH AND INSTALL ) ALL NECESSARY
INSTALL SINGLE THICKNESS INSTEAD.
MATERIALS AND LABOR FOR A COMPLETELY OPERATIONAL
HEATER KW
AIR CONDITIONING, HEATING AND VENTILATING SYSTEM AS
REFRIGERANT PIPING. SEAMLESS COPPER TYPE "L" AND
SHOWN ON THE DRAWINGS AND HEREIN SPECIFIED
HARD OR SOFT DRAWN ON ACR COPPER TUBING WITH
INSTALL IN ACCORDANCE WITH THE FLORIDA BUILDING CODE,
WROUGHT COPPER SOLDER JOINT FITTINGS, SOLDER
ASHRAE, SMACNA, NFPA, AND LOCAL ORDINANCES.
SHALL BE 95/5 APPLIED WITH SUITABLE FLUX.
1 -60 -240
INSULATE ALL REFRIGERANT SUCTION PIPING WITH 1/2"
SCOPE OF WORK:
CLOSED CELL POLYETHYLENE PREMOLDED PIPE
RHSAHM3617JA
INSULATION, WITH AN APPROVED PIPE AND SMOKE
PROVIDE THE FOLLOWING COMPLETE SYSTEMS
JACKET. PAINT ALL EXPOSED INSULATION WITH TWO
A. SUPPLY DUCT SYSTEM.
COATS OF WHITE LATEX PAINT.
B. EXHAUST SYSTEM FOR BATHROOMS
PROVIDE AIR CONDITIONING UNITS WITH MATCHING LOW
A/C DUCT IN NON AIR
VOLTAGE HEAT —COOL THERMOSTATS WITH ON —OFF AUTO
C. AIR CONDITIONING UNITS WITH REFRIGERANT PIPING
SUB —BASE SWITCH, FURNISHED BY THE EQUIPMENT
AND CONTROLS,
MANUFACTURER.
PAY FOR ALL FEES, INSPECTIONS AND CONNECTION
ALL AIR CONDITIONING COMPRESSORS SHALL BE
CHARGES REQUIRED .
WARRANTED FOR A MINIMUM OF FIVE YEARS AFTER DATE
OF ACCEPTANCE OF THE PROJECT.
VERIFY AT JOB SITE ALL SPACE CONDITIONS, DIMENSIONS
AND EQUIPMENT SIZES PRIOR TO DUCT FABRICATION OR
AIR DISTRIBUTION PRODUCTS
INSTALLATION, COORDINATE REQUIREMENTS TO AVOID
PROVIDE SUPPLY AND DIFFUSERS
INTERFERENCE WITH OTHER TRADES.
AS INDICATED ON THE DRAWINGS.
GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS
AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM
DATE OF ACCEPTANCE.
PROVIDE FINISHES AND TYPES OF MOUNT IN COORDINATION
WITH THE CEILING TYPES AS SHOWN ON ARCHITECTURAL
MATERIALS
DRAWINGS.
DUCTWORK (R -6) MIN.
INSTALLATION
GENERAL. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE
INSTALL ALL EQUIPMENT IN ACCORDANCE TO THE
DIMENSIONS.
MANUFACTURER'S MANUAL AND RECOMMENDATIONS
PAYING SPECIAL ATTENTION TO REQUIRED CLEARANCES
FOR INSTALLATION, OPERATION AND SERVICE.
1„
1
1 i �
/j
i
rr ; ti
SEAL JOINT WITH
DUCT SEALER
1 # y E
A/C SPLIT SYSTEM SCHEDULE
UNIT
1
TOTAL CAPACITY BTU /HR
35,000
SENS CAPACITY BTU /HR
24,650
CFM SUPPLY— TOTAL /OA
1200/200
HEATER KW
10
ESP —IN WG,
0.30
TEMP. AIR ENT, COIL DB /WB
80/67
C.U. FLA
19.2
VOLTAGE
1 -60 -240
MANUFACTURER
RHEEM OR EQUAL
AHU MODEL
RHSAHM3617JA
C.U. MODEL
RAND036JBZ
SEER
13.0
REF LIQUID /SUCTION
3/8" —7/8"
MIN. DUCT INSULATION SHALL BE R -6 FOR
A/C DUCT IN NON AIR
CONDITIONING SPACES.
* OR EQUAL
STRUCTURAL JOISTS
•� r
Evjw
•
OUTSISE AIR CALCULATIONS
PIERS 00
NVAC DESIGN REQUIRES: YES
NO
DUCT SMOKE DETECTOR
X
FIRE DAMPER(S)
X
SMOKE DAMPER(S)
X
FIRE RATED ENCLOSURE
X
FIRE RATED ROOF CEILING ASSEMBLY
X
FIRE STOPPING
X
SMOKE CONTROL
X
B R A
V 0
L L c
/ (y)
architecture
C a n n
i n g
interior
design
250 catolonla,
suite 403
coral gables, florida
33134
telephone ; 305
.567. 1977
facsimile 305. 567. 1125
REVISIONS.
I
SCALE:
AS NOTED
DRAWN BY: ,
/ (y)
CHECKED
L 1
W
PROJECT :O.
ILL
0
VI
o
REVISIONS.
I
SCALE:
AS NOTED
DRAWN BY: ,
I P..
CHECKED
08-17-09'
PROJECT :O.
�J MI
Z2
FLA. REGISTRAMON NO.: 6226-1