Loading...
09-848-011m3 �W °a Q . Y ma -6 cm C C ® 0 C E a, E Ci O U m m 0 v .- •v m m� c!i L4 3 F O. O m� O X '® G m O 4 a V O O. !n Ct OA c ®< O cm Z }. O to a r O C w E 0 J J � Q } LL o m 2] C Q r Q N !® M CL O R m .110 ® C r 4 ®a o C� O 0 C? h CD m � Q o H y C, C E 3. Q ®q v `o C > w4 jp C O < � Y dl .c c Ci h 0 U F t YM% MUZYWMA WI)M1 Pow Plmd.S 8(27(2004 2:33:01 PM, WDeP70d 1650[ Y4'° AE —CD FIDE TO OUTSIDE BLDG. TERMINATE 6" ABOVE GRADE & 1 ® -0" OFF WALL--\ ♦ • , • • • 2" X2 " XI /5 STEEL. ANGLE M r X r X 1/4" 5TEE O fR OF 1/2" THfRU E30LT OIR THREADED GOfRD OF J016T r * r METAL 5AND 1-1/2" 0 GA TYF=' ARROUND • ! UNIT AS SHOW TIE DOWN C:UFS it r )r # �• I a STEEL ANGLE r— \,' 5 ps: i ,TI ii NolfiPA -0— COATS •- -• • AND FIN15H W11 GOAT OF r f=AINT COND. UNIT SUPPURT DETAIL n.tm . AIR Cu"NDITIONING GENERAL NOTE GENERAL PROVIDE DOUBLE THICKNESS TURNING VANES AT ALL 35,000 SQUARE ELBOWS. WHERE THE ELBOWS ARE RECTANGULAR PROVIDE ( FURNISH AND INSTALL ) ALL NECESSARY INSTALL SINGLE THICKNESS INSTEAD. MATERIALS AND LABOR FOR A COMPLETELY OPERATIONAL HEATER KW AIR CONDITIONING, HEATING AND VENTILATING SYSTEM AS REFRIGERANT PIPING. SEAMLESS COPPER TYPE "L" AND SHOWN ON THE DRAWINGS AND HEREIN SPECIFIED HARD OR SOFT DRAWN ON ACR COPPER TUBING WITH INSTALL IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, WROUGHT COPPER SOLDER JOINT FITTINGS, SOLDER ASHRAE, SMACNA, NFPA, AND LOCAL ORDINANCES. SHALL BE 95/5 APPLIED WITH SUITABLE FLUX. 1 -60 -240 INSULATE ALL REFRIGERANT SUCTION PIPING WITH 1/2" SCOPE OF WORK: CLOSED CELL POLYETHYLENE PREMOLDED PIPE RHSAHM3617JA INSULATION, WITH AN APPROVED PIPE AND SMOKE PROVIDE THE FOLLOWING COMPLETE SYSTEMS JACKET. PAINT ALL EXPOSED INSULATION WITH TWO A. SUPPLY DUCT SYSTEM. COATS OF WHITE LATEX PAINT. B. EXHAUST SYSTEM FOR BATHROOMS PROVIDE AIR CONDITIONING UNITS WITH MATCHING LOW A/C DUCT IN NON AIR VOLTAGE HEAT —COOL THERMOSTATS WITH ON —OFF AUTO C. AIR CONDITIONING UNITS WITH REFRIGERANT PIPING SUB —BASE SWITCH, FURNISHED BY THE EQUIPMENT AND CONTROLS, MANUFACTURER. PAY FOR ALL FEES, INSPECTIONS AND CONNECTION ALL AIR CONDITIONING COMPRESSORS SHALL BE CHARGES REQUIRED . WARRANTED FOR A MINIMUM OF FIVE YEARS AFTER DATE OF ACCEPTANCE OF THE PROJECT. VERIFY AT JOB SITE ALL SPACE CONDITIONS, DIMENSIONS AND EQUIPMENT SIZES PRIOR TO DUCT FABRICATION OR AIR DISTRIBUTION PRODUCTS INSTALLATION, COORDINATE REQUIREMENTS TO AVOID PROVIDE SUPPLY AND DIFFUSERS INTERFERENCE WITH OTHER TRADES. AS INDICATED ON THE DRAWINGS. GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE. PROVIDE FINISHES AND TYPES OF MOUNT IN COORDINATION WITH THE CEILING TYPES AS SHOWN ON ARCHITECTURAL MATERIALS DRAWINGS. DUCTWORK (R -6) MIN. INSTALLATION GENERAL. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE INSTALL ALL EQUIPMENT IN ACCORDANCE TO THE DIMENSIONS. MANUFACTURER'S MANUAL AND RECOMMENDATIONS PAYING SPECIAL ATTENTION TO REQUIRED CLEARANCES FOR INSTALLATION, OPERATION AND SERVICE. 1„ 1 1 i � /j i rr ; ti SEAL JOINT WITH DUCT SEALER 1 # y E A/C SPLIT SYSTEM SCHEDULE UNIT 1 TOTAL CAPACITY BTU /HR 35,000 SENS CAPACITY BTU /HR 24,650 CFM SUPPLY— TOTAL /OA 1200/200 HEATER KW 10 ESP —IN WG, 0.30 TEMP. AIR ENT, COIL DB /WB 80/67 C.U. FLA 19.2 VOLTAGE 1 -60 -240 MANUFACTURER RHEEM OR EQUAL AHU MODEL RHSAHM3617JA C.U. MODEL RAND036JBZ SEER 13.0 REF LIQUID /SUCTION 3/8" —7/8" MIN. DUCT INSULATION SHALL BE R -6 FOR A/C DUCT IN NON AIR CONDITIONING SPACES. * OR EQUAL STRUCTURAL JOISTS •� r Evjw • OUTSISE AIR CALCULATIONS PIERS 00 NVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR X FIRE DAMPER(S) X SMOKE DAMPER(S) X FIRE RATED ENCLOSURE X FIRE RATED ROOF CEILING ASSEMBLY X FIRE STOPPING X SMOKE CONTROL X B R A V 0 L L c / (y) architecture C a n n i n g interior design 250 catolonla, suite 403 coral gables, florida 33134 telephone ; 305 .567. 1977 facsimile 305. 567. 1125 REVISIONS. I SCALE: AS NOTED DRAWN BY: , / (y) CHECKED L 1 W PROJECT :O. ILL 0 VI o REVISIONS. I SCALE: AS NOTED DRAWN BY: , I P.. CHECKED 08-17-09' PROJECT :O. �J MI Z2 FLA. REGISTRAMON NO.: 6226-1