Loading...
11-1227-005I.eclend 0 GROUND FLOOR EXIST. PANEL A 200 A 1PH DISC. E I OR 2 HOUR FIRE RATED WALL gZ9990 OPENING PROTECTIVE MATERIALS FOR ELECTRICAL 3735 Green Rd. U51NG TREM5TOP MP. Bcachwood, OH, 44122 Drawing not to scale I OR 2 HOUR FIRE RATED STEEL STUD r A55EM51-YALL METALLIC OUTLET - UNPROTECTED- 5TEE 5TUC FRONT VIEW CONDUIT �fl (EMT) CONDUIT 'EMT) SIDE VIEW STEEL STUD CONDUIT TREM5TOP TREM5TOPI I OR 2 HOUR FIRE RATED MP GYPSUM WALL ASSEMBLY UUCUL CLASSIFIED WALL OPENING PROTECTIVE MATERIAL: TREMCO TREM5TOP MP D5 �$ METER RISER SPA SPA DISC. EXIST. EXIST. EXIST. 4 200 A DISC. DISC. DISC. INCANDESCENT LUMINARY, SURFACE MOUNTED. 0 0 ��"" 3 -4&-- EXHAUST FAN MOTOR PO INCANDESCENT LUMINARY, WALL MOUNTED ABOVE DOOR OR 8' -0" A.F.F. O EXIST. EXIST. UNLESS OTHERWISE INDICATED. A.F.F. ABOVE FINISHED FLOOR METER METER GFI GROUND FAULT INTERRUPTER SD WALL SMOKE DETECTOR 120/240 VOLTS W � WP WEATHER- RESITANT SD SMOKE DETECTOR J�— - DENOTES GROUND WIRE PHASE: SINGLE POLE LIGHT SWITCH, QUIET TYPE, 120 VOLTS, 20 AMPS FOR OUTDOOR E]l DISCONNECT SWITCH. AND D15PO55AL CIRCUITS, INSTALL 48" A.F.F. U THREE WAY LIGHT SWITCH, QUIET TYPE, 120 VOLTS, 15 AMPS. INSTALL 48" A.F.F. EXIT EXIT SIGN WBATT. BACK UP W LIGHT SWITCH W/ DIMMER, QUIET TYPE, 120 VOLTS, 15 AMPS. INSTALL 48" A.F.F. EXIT EXIT SIGN /EMERGENCY LIGHT WBATT. BACK UP d) DEDICATED RECEPTACLE OUTLET. INSTALL 18" A.F.F. UNLESS OTHERWISE INDICATED F- WIRE EMERGENCY LIGHT W/ BATT. BACK UP CIRCUIT ID RECEPTACLE OUTLET. INSTALL 18" A.F.F. UNLESS OTHERWISE INDICATED POLE ripA 63 THREE RECEPTACLE OUTLET. INSTALL 18" A.F.F. UNLESS OTHERWISE INDICATED TWH TANKLESS WATER HEATER TripA POLE5 HD ELECTRICAL HAND DRYER 64 FOUR RECEPTACLE OUTLET. INSTALL 18" A.F.F. UNLESS OTHERWISE INDICATED 0 BRAND NAME: XLERATOR RECEPTACLE OUTLET GFI. INSTALL AT A.F.F. INDICATED W/D WASHER AND DRYER ® FLOOR LEVEL RECEPTACLES z 2'x2' PARABOLIC FIXTURE ® SPECIAL RECEPTACLE OUTLET, 250 VOLTS, 3 -WIRE, GROUNDING TYPE, AMPS L;aL ELECTRICAL PANEL W SHOWN. MOUNTING HEIGHT AS INDICATED 2- #8 3/4" T TELEPHONE/DATA OUTLET, INSTALL 18" A.F.F. UNLESS OTHERWISE INDICATED 2 50 —E CABLE T.V. OUTLET. INSTALL 18" A.F.F. UNLESS OTHERWISE INDICATED SPARE E EXISTING EL 0 GROUND FLOOR EXIST. PANEL A 200 A 1PH DISC. E I OR 2 HOUR FIRE RATED WALL gZ9990 OPENING PROTECTIVE MATERIALS FOR ELECTRICAL 3735 Green Rd. U51NG TREM5TOP MP. Bcachwood, OH, 44122 Drawing not to scale I OR 2 HOUR FIRE RATED STEEL STUD r A55EM51-YALL METALLIC OUTLET - UNPROTECTED- 5TEE 5TUC FRONT VIEW CONDUIT �fl (EMT) CONDUIT 'EMT) SIDE VIEW STEEL STUD CONDUIT TREM5TOP TREM5TOPI I OR 2 HOUR FIRE RATED MP GYPSUM WALL ASSEMBLY UUCUL CLASSIFIED WALL OPENING PROTECTIVE MATERIAL: TREMCO TREM5TOP MP D5 �$ METER RISER SPA SPA DISC. EXIST. EXIST. EXIST. 4 200 A DISC. DISC. DISC. EXIST. GUTTER EXISTING ELECTRICAL RISER O DISC. 3PH MAIN GENERAL ELECTRICAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, N.E.0 AND OTHER APPLICABLE CODES AND STANDARDS. 2. THE CONTRACTOR 15 RESPONSIBLE FOR EVALUATING FIELD CONDITIONS BY VISITING THE SITE PRIOR TO COMMENCING /BIDDING WORK 3. THE CONTRACTOR SHALL SATISFACTORILY REPAIR/REPLACE EQUIPMENT OR PART OF STRUCTURE DAMAGED AS A RESULT OF HIS WORK. SURFACES AND FINISHED AREAS SHALL BE RESTORED TO MATCH ADJACENT AREAS. 4. ALL MATERIALS SHALL BE U.L. APPROVED. 5. NEW TYPEWRITTEN PANEL TALLY SHALL BE FURNISHED AFTER JOB 15 COMPLETED REFLECTING ALL CHANGES AND ADDITIONS. G. ALL BRANCH CIRCUITS SHALL BE PROPERLY PHASE BALANCED. 7. CONTRACTOR SHALL SEAL ALL OPENINGS WITH A FIRE SEAL 51MILAR TO 'OZ' FLAME5EAL. 8. FUSES SHALL BE DUAL ELEMENT, TIME DELAY TYPE UNLESS OTHERWISE NOTED. 9. THI5 DRAWING IS A GUIDE FOR THE INSTALLATION OF ELECTRICAL SERVICE. THE ELECTRICAL CONTRACTOR 15 RESPONSIBLE IN PROVIDING A FUNCTIONAL SYSTEM. 10. ALL CABLES SHALL BE RUN WITHOUT SPLICES EXCEPT OTHERWISE INDICATED. 1 1. EXACT POINT AND METHODS OF CONNECTION SHALL BE DETERMINED IN FIELD. 12. ALL WORK SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER. 13. ALL UNDERGROUND CONDUIT RUNS TO HAVE MINIMUM 24" COVER. 14. ALL EXTERIOR ELECTRICAL EQUIPMENT SHALL BE WEATHER -PROOF OR SHALL BE IN WEATHER -PROOF ENCLOSURE 15. ALL TRENCHING, BACKFILLING, SHALL BE DONE BY ELECTRICAL CONTRACTOR. I G. ALL UNDERGROUND 'PVC' SHALL BE PROVIDED WITH GALVANIZED RIGID ELBOWS AND ADAPTERS AS REQUIRED INSIDE BUIL;DING. 17. CONDUIT RUNNING UNDER PAVING SHALL BE 24 INCHES BELOW FINISH GRADE, MINIMUM. ALL FLUORESCENT FIXTURES SHALL HAVE A MEANS TO DISCONECT THE BALLAST FROM THE CIRCUIT CONDUCTOR EXISTING PANEL A 0 0 0 0 3 O 200 A DISC. 5O 1 SET(3- #3/0 THHW Cu +(1) #4 G ) O EXIST. EXIST. EXIST. EXIST. 5/8" X 10' LONG GROUND ROD METER METER METER METER EXIST. GUTTER EXISTING ELECTRICAL RISER O DISC. 3PH MAIN GENERAL ELECTRICAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, N.E.0 AND OTHER APPLICABLE CODES AND STANDARDS. 2. THE CONTRACTOR 15 RESPONSIBLE FOR EVALUATING FIELD CONDITIONS BY VISITING THE SITE PRIOR TO COMMENCING /BIDDING WORK 3. THE CONTRACTOR SHALL SATISFACTORILY REPAIR/REPLACE EQUIPMENT OR PART OF STRUCTURE DAMAGED AS A RESULT OF HIS WORK. SURFACES AND FINISHED AREAS SHALL BE RESTORED TO MATCH ADJACENT AREAS. 4. ALL MATERIALS SHALL BE U.L. APPROVED. 5. NEW TYPEWRITTEN PANEL TALLY SHALL BE FURNISHED AFTER JOB 15 COMPLETED REFLECTING ALL CHANGES AND ADDITIONS. G. ALL BRANCH CIRCUITS SHALL BE PROPERLY PHASE BALANCED. 7. CONTRACTOR SHALL SEAL ALL OPENINGS WITH A FIRE SEAL 51MILAR TO 'OZ' FLAME5EAL. 8. FUSES SHALL BE DUAL ELEMENT, TIME DELAY TYPE UNLESS OTHERWISE NOTED. 9. THI5 DRAWING IS A GUIDE FOR THE INSTALLATION OF ELECTRICAL SERVICE. THE ELECTRICAL CONTRACTOR 15 RESPONSIBLE IN PROVIDING A FUNCTIONAL SYSTEM. 10. ALL CABLES SHALL BE RUN WITHOUT SPLICES EXCEPT OTHERWISE INDICATED. 1 1. EXACT POINT AND METHODS OF CONNECTION SHALL BE DETERMINED IN FIELD. 12. ALL WORK SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER. 13. ALL UNDERGROUND CONDUIT RUNS TO HAVE MINIMUM 24" COVER. 14. ALL EXTERIOR ELECTRICAL EQUIPMENT SHALL BE WEATHER -PROOF OR SHALL BE IN WEATHER -PROOF ENCLOSURE 15. ALL TRENCHING, BACKFILLING, SHALL BE DONE BY ELECTRICAL CONTRACTOR. I G. ALL UNDERGROUND 'PVC' SHALL BE PROVIDED WITH GALVANIZED RIGID ELBOWS AND ADAPTERS AS REQUIRED INSIDE BUIL;DING. 17. CONDUIT RUNNING UNDER PAVING SHALL BE 24 INCHES BELOW FINISH GRADE, MINIMUM. ALL FLUORESCENT FIXTURES SHALL HAVE A MEANS TO DISCONECT THE BALLAST FROM THE CIRCUIT CONDUCTOR EXISTING PANEL A SERVICE FROM FPL O GENERAL DISC. O METER O 200 A DISC. 5O 1 SET(3- #3/0 THHW Cu +(1) #4 G ) O 150 A DISC 7O 2/0 G IN 1" C O 5/8" X 10' LONG GROUND ROD AIC: 10 000 AMPS #4 G IN 3/4" C W VOLTAGE: 120/240 VOLTS W � MAIN: 200 AMPS CU �0 PHASE: I PHA5E,3 WIRES BREAKER 51ZE:MLO U J J Q W Z Circuit F- WIRE COND CIRCUIT ID LOAD POLE ripA CKT# LI L2 CKT# TripA POLE5 LOAD CIRCUIT ID WIRE COND 0 O F- ao 3 X 0 4 Z F Cl) W m 2- #8 3/4" AHU 8500 2 50 GO 2 SPARE 2 - #G 3/4" EL X O 7 X 8 2 - #G 3/4" TWH 11800 2 GO 40 2 7600 CU 24 10 3/4" X 24 12 1/2" BATH GFC 1 1500 1 20 9 X 10 20 1 1 500 GENERAL LIGHT. 2412 1/2" 24 12 1 /2" GENERAL LIGHT 1500 1 20 1 1 X 12 20 1 1500 GENERAL LIGHT 24 12 1/2" 24 12 1/2" GENERAL RECEP. 1 500 1 20 13 X 14 20 1 1500 GENERAL LIGHT 24 12 1/2" 24 12 112" GENERAL RECEP. 1 500 1 20 15 X I G 20 1 1 500 GENERAL LIGHT. 24 12 1/2" 24 12 1/2" WASHER MACH. 1500 1 20 17 X 18 20 1 1500 GENERAL RECEP. 24 12 1/2" 24 10 3/4" DRYER 4500 2 30 19 X 20 20 I 11500 GENERAL RECEP. 24 12 1/2" 21 X 22 20 I 1.530 GENERAL LIGHT 2-#12 1/2" 24 12 1 /2" GENERAL LIGHT 1500 1 20 23 X 1 24 20 I 1.530 GENERAL LIGHT 24 12 1/2" PANEL VA = 19,300 VA 25% LIGHTING LOAD = 2,GG5 VA A/C = I G, 100 VA TOTAL VA = 38,OG5 VA1240 V = 158.G AMP EX. 200 AMPS. ELECTRICAL PANEL 0 GROUND FLOOR DIAGRAM THE FOLLOWING LIFE SAFETY FEATURETI SHALL BE PROVIDED AT TIME OF QCCUPA FIRE DEPARTIVff NTH APPROVED BY MIAM-DADS COMM FIX KIT Bl.D6. PIERPVt(► �r WATWt MAIN SXTEN84 DATE // / ®Y I'Y ELECTRICAL RISER CODED NOTES O SERVICE FROM FPL O GENERAL DISC. O METER O 200 A DISC. 5O 1 SET(3- #3/0 THHW Cu +(1) #4 G ) O 150 A DISC 7O 2/0 G IN 1" C O 5/8" X 10' LONG GROUND ROD 9O #4 G IN 3/4" C 4E \ / PS) IONS THESE DRAWING do SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF JORGE ALBA WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED OR NOT, THEY ARE NOT TO BE USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH THE APPROPRIATE COMPENSATION TO JORGE ALBA F w w Z Q J J U_ LJ. f U W W JORGE ALBA PROFESSIONAL ENGINEER P.E. 63967 407 PHIPPEN ROAD DANIA BEACH, FL. 33004 (954) 483 -5031 DATE 11/26/11 DRAWN BY. M. GUILLEN CHECKED BY: JA SCALE: AS SHOW E -1 SHEET NUMBER: 5 0 W N_ J Q o W J W � m CU �0 0 I U J J Q W Z F- W F- a W O 0 z a U) Z 0 O F- ao U) 0 0 Z F Cl) W m Z Z Lu LLI Z 0 LLI EL 0 O F w w Z Q J J U_ LJ. f U W W JORGE ALBA PROFESSIONAL ENGINEER P.E. 63967 407 PHIPPEN ROAD DANIA BEACH, FL. 33004 (954) 483 -5031 DATE 11/26/11 DRAWN BY. M. GUILLEN CHECKED BY: JA SCALE: AS SHOW E -1 SHEET NUMBER: 5 0